Text preview for : Midea_MSG_service_manual.pdf part of Midea MSG Service manual.
Back to : Midea_MSG_service_manual. | Home
MSG-07CRN2; MSG-07HRN2 MSG-09CRN2; MSG-09HRN2 MSG-12CRN2; MSG-12HRN2 MSG-16CRN2; MSG-16HRN2 MSG-18CRN2; MSG-18HRN2 MSG-21CRN2; MSG-21HRN2
Content
Content
1.
1.1 1.2
Precaution .................................................................................................................... 1
Safety Precaution ...................................................................................................................... 1 Warning ..................................................................................................................................... 1
2. 3.
3.1 3.2
Function ....................................................................................................................... 3 Dimension .................................................................................................................... 5
Indoor unit.................................................................................................................................. 5 Outdoor unit ............................................................................................................................... 6
4. 5. 6.
6.1 6.2
Specification ................................................................................................................ 7 Refrigerant cycle diagram......................................................................................... 11 Operation limits ......................................................................................................... 12
Cooling operation..................................................................................................................... 12 Heating operation .................................................................................................................... 12
7.
7.1 7.2
Schematic diagram and Wiring diagram ................................................................. 13
Schematic diagram .................................................................................................................. 13 Wiring diagram......................................................................................................................... 14
8.
8.1 8.2 8.3 8.4 8.5 8.6 8.7 8.8 8.9
Installation details...................................................................................................... 19
Wrench torque sheet for installation......................................................................................... 19 Connecting the cables ............................................................................................................. 19 Pipe length and the elevation................................................................................................... 19 Air purging of the piping and indoor unit .................................................................................. 20 Pumping down (Re-installation) ............................................................................................... 21 Re-air purging (Re-installation) ................................................................................................ 22 Balance refrigerant of the 2-way, 3-way valves........................................................................ 23 Evacuation ............................................................................................................................... 24 Gas charging ........................................................................................................................... 25
9.
9.1 9.2 9.3 9.4 9.5 9.6 9.7 9.8 9.9 9.10 9.11 9.12
Capacity table ............................................................................................................ 26
MSG-07CRN2.......................................................................................................................... 26 MSG-07HRN2.......................................................................................................................... 26 MSG-09CRN2.......................................................................................................................... 27 MSG-09HRN2.......................................................................................................................... 27 MSG-12CRN2.......................................................................................................................... 28 MSG-12HRN2.......................................................................................................................... 28 MSG-16CRN2.......................................................................................................................... 29 MSG-16HRN2.......................................................................................................................... 29 MSG-18CRN2.......................................................................................................................... 30 MSG-18HRN2.......................................................................................................................... 30 MSG-21CRN2.......................................................................................................................... 31 MSG-21HRN2.......................................................................................................................... 31
10.
10.1
-1-
Electronic function .................................................................................................... 32
Electronic control working environment ................................................................................... 32
Content
10.2 10.3 10.4 10.5 10.6 10.7 10.8 10.9 10.10 10.11 10.12 10.13 10.14
Proper symbols and their meaning .......................................................................................... 32 Function ................................................................................................................................... 32 Protection................................................................................................................................. 33 Fan-only mode......................................................................................................................... 33 Cooling mode........................................................................................................................... 33 Dehumidifying mode ................................................................................................................ 34 Heating mode .......................................................................................................................... 35 Defrosting mode(available for heating mode) .......................................................................... 36 Auto mode ............................................................................................................................... 37 Force cooling function.............................................................................................................. 38 Sleep mode.............................................................................................................................. 38 Auto restart function................................................................................................................. 39 Anion (optional)........................................................................................................................ 39
11. 12.
12.1 12.2 12.3 12.4 12.5 12.6 12.7 12.8 12.9
Model and Parameters .............................................................................................. 40 Troubleshooting......................................................................................................... 41
Display board........................................................................................................................... 41 Troubleshooting ....................................................................................................................... 42 Diagnostic chart ....................................................................................................................... 43 Resetting phenomenon often occurs during operation............................................................. 44 Operation lamp flashes and Timer lamp off. ............................................................................ 44 Operation lamp flashes and Timer lamp on. ............................................................................ 44 Operation lamp off and Timer lamp flashes ............................................................................. 45 Operation lamp on and Timer lamp flashes ............................................................................. 45 Operation lamp flashes, Timer lamp flashes . .......................................................................... 45
13.
Characteristic of temperature sensor ...................................................................... 46
-2-
Service manual
1. Precaution
1.1 Safety Precaution
To prevent injury to the user or other people and property damage, the following instructions must be followed. Incorrect operation due to ignoring instruction will cause harm or damage. Before service unit, be sure to read this service manual at first.
1.2
Warning
windows is left open. Moisture may condense and wet or damage furniture. Take care to ensure that power cable could not be pulled out or damaged during operation. There is risk of fire or electric shock. Do not place anything on the power cable. There is risk of fire or electric shock. Do not plug or unplug the power supply plug during operation. There is risk of fire or electric shock. Do not touch (operation) the product with wet hands. There is risk of fire or electric shock. Do not place a heater or other appliance near the power cable. There is risk of fire and electric shock. Do not allow water to run into electric parts. It may cause fire, failure of the product, or electric shock. Do not store or use flammable gas or combustible near the product. There is risk of fire or failure of product. Do not use the product in a tightly closed space for a long time. Oxygen deficiency could occur. When flammable gas leaks, turn off the gas and open a window for ventilation before turn the product on. Do not use the telephone or turn switches on or off. There is risk of explosion or fire. If strange sounds, or small or smoke comes from product. Turn the breaker off or disconnect the power supply cable. There is risk of electric shock or fire. Stop operation and close the window in storm or hurricane. If possible, remove the product from the window before the hurricane arrives. There is risk of property damage, failure of product, or electric shock. Do not open the inlet grill of the product during operation. (Do not touch the electrostatic filter, if the
Installation
Do not use a defective or underrated circuit breaker. Use this appliance on a dedicated circuit. There is risk of fire or electric shock. For electrical work, contact the dealer, seller, a qualified electrician, or an Authorized service center. Do not disassemble or repair the product, there is risk of fire or electric shock. Always ground the product. There is risk of fire or electric shock. Install the panel and the cover of control box securely. There is risk of fire of electric shock. Always install a dedicated circuit and breaker. Improper wiring or installation may cause fore or electric shock. Use the correctly rated breaker of fuse. There is risk of fire or electric shock. Do not modify or extend the power cable. There is risk of fire or electric shock. Do not install, remove, or reinstall the unit by yourself (customer). There is risk of fire, electric shock, explosion, or injury. Be caution when unpacking and installing the product. Sharp edges could cause injury, be especially careful of the case edges and the fins on the condenser and evaporator. For installation, always contact the dealer or an Authorized service center. There is risk of fire, electric shock, explosion, or injury. Do not install the product on a defective installation stand. It may cause injury, accident, or damage to the product. Be sure the installation area does not deteriorate with age. If the base collapses, the air conditioner could fall with it, causing property damage, product failure, and personal injury. Do not let the air conditioner run for a long time when the humidity is very high and a door or a -1-
Service manual unit is so equipped.) There is risk of physical injury, electric shock, or product failure. When the product is soaked (flooded or submerged), contact an Authorized service center. There is risk of fire or electric shock. Be caution that water could not enter the product. There is risk of fire, electric shock, or product damage. Ventilate the product from time to time when operating it together with a stove, etc. There is risk of fire or electric shock. Turn the main power off when cleaning or maintaining the product. There is risk of electric shock. When the product is not be used for a long time, disconnect the power supply plug or turn off the breaker. There is risk of product damage or failure, or unintended operation. Take care to ensure that nobody could step on or fall onto the outdoor unit. This could result in personal injury and product damage.
Operational
Do not expose the skin directly to cool air for long periods of time. (Do not sit in the draft). This could harm to your health. Do not use the product for special purposes, such as preserving foods, works of art, etc. It is a consumer air conditioner, not a precision refrigerant system. There is risk of damage or loss of property. Do not block the inlet or outlet of air flow. It may cause product failure. Use a soft cloth to clean. Do not use harsh detergents, solvents, etc. There is risk of fire, electric shock, or damage to the plastic parts of the product. Do not touch the metal parts of the product when removing the air filter. They are very sharp. There is risk of personal injury. Do not step on pr put anything on the product. (outdoor units) There is risk of personal injury and failure of product. Always insert the filter securely. Clean the filter every two weeks or more often if necessary. A dirty filter reduces the efficiency of the air conditioner and could cause product malfunction or damage. Do not insert hands or other object through air inlet or outlet while the product is operated. There are sharp and moving parts that could cause personal injury. Do not drink the water drained from the product. It is not sanitary could cause serious health issues. Use a firm stool or ladder when cleaning or maintaining the product. Be careful and avoid personal injury. Replace the all batteries in the remote control with new ones of the same type. Do not mix old and mew batteries or different types of batteries. There is risk of fire or explosion. Do not recharge or disassemble the batteries. Do not dispose of batteries in a fire. They may burn of explode. If the liquid from the batteries gets onto your skin or clothes, wash it well with clean water. Do not use the remote of the batteries have leaked. The chemical in batteries could cause burns or other health hazards.
CAUTION
Always check for gas (refrigerant) leakage after installation or repair of product. Low refrigerant levels may cause failure of product. Install the drain hose to ensure that water is drained away properly. A bad connection may cause water leakage. Keep level even when installing the product. To avoid vibration of water leakage. Do not install the product where the noise or hot air from the outdoor unit could damage the neighborhoods. It may cause a problem for your neighbors. Use two or more people to lift and transport the product. Avoid personal injury. Do not install the product where it will be exposed to sea wind (salt spray) directly. It may cause corrosion on the product. Corrosion, particularly on the condenser and evaporator fins, could cause product malfunction or inefficient operation.
-2-
Service manual
2. Function
Indoor unit
Operation ON/OFF by remote controller
Sensing by room temperature
Room temperature sensor. Pipe temperature sensor.
Room temperature control
Maintain the room temperature in accordance with the setting temperature.
Starting temperature control
Indoor fan is delayed for 5 sec at the starting.
Time Delay Safety control
Restarting is for approx. 3 minutes..
Indoor fan speed control
High, med, low, breeze.
Operation indication Lamps (LED)
Light up in the LED (LCD) for each operation mode.
Two-direction air vane
The unit will decide the louver direction according to operation mode.
Anti-cold function
Prevent the cold wind at the beginning of unit start.
Sleep mode auto control
The fan is turn to low speed (cooling/heating). The unit will be turn off after seven hours.
Temp. Compensation
Independent dehumidification
The function is usually used in rainy days in springtime or damp areas.
Defrost mode
Auto-restart function
Self-diag. function
The function will be operate in any operation
Flexible wiring connection
Air flow Direction control
The louver can be set at the desired position or swing up and down automatically
Easy clean panel
Auto mode
-3The unit can be change by the room temperature.
Service manual
Outdoor unit
Power relay control
The unit has 3 mins delay between continuously ON/OFF operations.
Low ambient kit
The unit can operate in cooling mode at low ambient temperature conditions.
Low noise air flow system
Bird tail propeller fan makes the outdoor unit run more quietly.
Hydrophilic aluminum fin
The hydrophilic fin can improve the heating efficiency at operation mode.
4 way valve control
It is only operated in the heating operation mode except defrosting operation.
Discharge pipe temperature protect
Anti-rust cabinet
Made from electrolytic zinc steel sheet and anti-rust coated components.
Valve protection
It protects the valves and prevents water from dripping.
-4-
Service manual
3. Dimension
3.1 Indoor unit
Dimension Mode 7K 9K 12K 16K 18K 21K
W 750 750 750 906 906 906
H 250 250 250 286 286 286
L 188 188 188 235 235 235
-5-
Service manual
3.2 Outdoor unit
Dimension Mode 7K 9K 12K 16K 18K 21K
W 700 700 780 760 760 845
H 535 535 540 590 590 695
D 235 235 250 285 285 335
L1 458 458 530 540 540 560
L2 280 280 315 335 335 360
L3 540 540 590 615 615 735
-6-
Service manual
4. Specification
Model Power supply Cooling Capacity Input Rated current EER Capacity Input Rated current COP Ph-V-Hz Btu/h W A Btu/w.h Btu/h W A W/W A A MSG-07CRN2 1, 220-240V~,50Hz 7000 780 3.5 9.0,2.6 ----------------4.4 18 PG135X1C-4DZ2 Rotary TOSHIBA 8086/8172 765/785 3.52/3.34 21 UP3SE0591-T71 25 400 RPG13H Welling 37.5 1.2 1020/960/900 430/400/370 35/32/30 YDK24-6T Welling 70 3 850 1500 49 650 2.8 6.35/9.53 10 5 17-30 18-45 10-14 MSG-07HRN2 1, 220-240V~,50Hz 7000 780 3.5 9.0,2.6 8000 800 3.6 2.9 4.4 18 PG135X1C-4DZ2 Rotary TOSHIBA 8086/8172 765/785 3.52/3.34 21.0 UP3SE0591-T71 25 400 RPG13H Welling 36.5 1.2 1020/960/900 430/400/370 35/32/30 YDK24-6T Welling 70 3 850 1500 49 740 2.8 6.35/9.53 10 5 17-30 -7 - 45 10-14 MSG-09CRN2 1, 220-240V~,50Hz 9000 1000 4.4 9.0,2.6 ----------------6 19.8 PG180X1C-4DZ3 Rotary TOSHIBA 10800 1015 4.5 19.8 UP3SE0591-T61 30 400 RPG13H Welling 39.5 1.2 1100/1020/950 470/440/410 36/32/30 YDK24-6T WELLING 70 3 850 1600 52 620 2.8 6.35/9.53 10 5 17-30 18-45 10-14
Heating
Max. current Starting current Model Type Brand Capacity Input Compressor Rated current(RLA) Locked rotor Amp(LRA) Thermal protector Capacitor Refrigerant oil Model Brand Indoor Input fan motor Capacitor Speed(hi/mi/lo) Indoor air flow (Hi/Mi/Lo) Indoor noise level (Hi/Mi/Lo) Model Brand Outdoor Input fan motor Capacitor Speed Outdoor air flow Outdoor noise level Refrigerant type R407C Design pressure Liquid side/ Gas side Refrigerant Max. refrigerant pipe length piping Max. difference in level Operation temp Ambient temp Application area
Btu/h W A A uF ml
W uF r/min m3/h dB(A)
W uF r/min 3 m /h dB(A) g MPa mm m m 2 m
Note:
The noise date is base on hemi-anechoic chamber, during actual operation; these values are normally somewhat different as a result of ambient condition. The above design and specifications are subject to change without prior notice for product improvement.
-7-
Service manual
Model Power supply Capacity Input Cooling Rated current EER Capacity Input Heating Rated current COP Max. current Starting current Model Type Brand Capacity Input Compressor Rated current(RLA) Locked rotor Amp(LRA) Thermal protector Capacitor Refrigerant oil Model Brand Indoor Input fan motor Capacitor Speed(hi/mi/lo) Indoor air flow (Hi/Mi/Lo) Indoor noise level (Hi/Mi/Lo) Model Brand Outdoor Input fan motor Capacitor Speed Outdoor air flow Outdoor noise level Refrigerant type R407C Design pressure Liquid side/ Gas side Refrigerant Max. refrigerant pipe length piping Max. difference in level Operation temp Ambient temp Application area
MSG-09HRN2 MSG-12CRN2 MSG-12HRN2 Ph-V-Hz 1, 220-240V~,50Hz 1, 220-240V~,50Hz 1, 220-240V~,50Hz 12000 12000 Btu/h 9000 1330 1330 W 1000 6 6 A 4.4 9.0,2.6 9.0 ,2.6 9.0 ,2.6 Btu/w.h 14000 Btu/h 11000 ----1400 W 1100 ----6.3 A 4.9 ----W/W 2.9 ----2.9 A 6 7 8 19.8 A 33 33 PG180X1C-4DZ3 PG225X2C-4FT PG225X2C-4FT Rotary rotary rotary TOSHIBA TOSHIBA TOSHIBA Btu/h 10800 13550/13700 13550/13700 W 1015 1290/1335 1290/1335 A 4.5 6.1 6.1 A 19.8 33 33 UP3SE0591-T61 UP3RE0591-T56 UP3RE0591-T56 30 uF 35 35 400 ml 480 480 RPG13H RPG18H RPG18H Welling WELLING WELLING 38.5 50 50 W 1.2 1.5 1.5 uF r/min 1100/1020/950 1250/1150/1050 1250/1150/1050 470/440/410 m3/h 500/450/400 500/450/400 36/32/30 40/36/34 40/36/34 dB(A) YDK24-6T YDK25-6C YDK25-6C Welling WELLING WELLING 70 W 68 68 3 uF 2.5 2.5 850 r/min 900 900 3 1600 1900 1900 m /h dB(A) 52 55 55 g 800 780 1100 2.8 2.8 MPa 2.8 mm 6.35/9.53 6.35/12.7 6.35/12.7 m 10 10 10 m 5 5 5 17-30 17-30 17-30 -7 - 45 18-45 18-45 2 14-21 18-26 18-26 m
Note:
The noise date is base on hemi-anechoic chamber, during actual operation; these values are normally somewhat different as a result of ambient condition. The above design and specifications are subject to change without prior notice for product improvement.
-8-
Service manual
Model Power supply Capacity Input Cooling Rated current EER Capacity Input Heating Rated current COP Max. current Starting current Model Type Brand Capacity Input Compressor Rated current(RLA) Locked rotor Amp(LRA) Thermal protector Capacitor Refrigerant oil Model Brand Indoor Input fan motor Capacitor Speed(hi/mi/lo) Indoor air flow (Hi/Mi/Lo) Indoor noise level (Hi/Mi/Lo) Model Brand Outdoor Input fan motor Capacitor Speed Outdoor air flow Outdoor noise level Refrigerant type R407C Design pressure Liquid side/ Gas side Refrigerant Max. refrigerant pipe length piping Max. difference in level Operation temp Ambient temp Application area
MSG-16CRN2 Ph-V-Hz 1, 220-240V~,50Hz Btu/h 16000 W 1810 A 8.3 Btu/w.h 8.8, 2.6 Btu/h W A W/W A 13 A 41 PG295*2CS-4KU1 Rotary GD Toshiba Btu/h 18083 W 1760 A 8.5 A 40 Internal uF 35UF/370V ml 750 RPG25 WELLING W 53 uF 1.5uF/450V r/min 1260/1100/1000 800/770/740 m3/h dB(A) 42/40/38 YDK36-6 WELLING 96 W 2.5F/450V uF 900 r/min 3 1900 m /h dB(A) 53 g 1380 MPa 2.8 mm 6.35/12.7 m 10 m 5 17-30 18-45 2 25-35 m
MSG-16HRN2 220-240V~,50Hz 16000 1820 8.3 8.8, 2.6 18000 1660 7.6 3.2 13 41 PG295*2CS-4KU1 Rotary GD Toshiba 18083 1760 8.5 40 Internal 35UF/370V 750 RPG25 WELLING 53 1.5uF/450V 1260/1100/1000 800/770/740 42/40/38 YDK36-6 WELLING 96 2.5F/450V 900 1900 53 1380 2.8 6.35/12.7 10 5 17-30 -7 - 45 25-35
MSG18CRN2 220-240V~,50Hz 17000 1890 8.5 9.0, 2.63
13 41 PG295*2CS-4KU1 Rotary GD Toshiba 18083 1760 8.5 40 Internal 35UF/370V 750 RPG25 WELLING 53 1.5uF/450V 1260/1100/1000 800/770/740 42/40/38 YDK36-6 WELLING 96 2.5F/450V 900 1900 53 2200 2.8 6.35/12.7 10 5 17-30 18-45 30-40
Note:
The noise date is base on hemi-anechoic chamber, during actual operation; these values are normally somewhat different as a result of ambient condition. The above design and specifications are subject to change without prior notice for product improvement.
-9-
Service manual
Model Power supply Capacity Input Cooling Rated current EER Capacity Input Heating Rated current COP Max. current Starting current Model Type Brand Capacity Input Compressor Rated current(RLA) Locked rotor Amp(LRA) Thermal protector Capacitor Refrigerant oil Model Brand Indoor Input fan motor Capacitor Speed(hi/mi/lo) Indoor air flow (Hi/Mi/Lo) Indoor noise level (Hi/Mi/Lo) Model Brand Outdoor Input fan motor Capacitor Speed Outdoor air flow Outdoor noise level Refrigerant type R407C Design pressure Liquid side/ Gas side Refrigerant Max. refrigerant pipe length piping Max. difference in level Operation temp Ambient temp Application area
MSG-18HRN2 MSG-21CRN2 MSG-21HRN2 Ph-V-Hz 1, 220-240V~,50Hz 1, 220-240V~,50Hz 1, 220-240V~,50Hz 18000 18000 Btu/h 17000 2080 2080 W 1890 9.5 9.5 A 8.5 8.7, 2.54 8.7, 2.54 Btu/w.h 9.0, 2.63 ----22000 Btu/h 19000 ----W 1900 2450 ----A 8.6 11.2 ----W/W 2.93 2.63 A 13 13 13 44 44 A 41 PG295*2CS-4KU1 PG340X3CS-4KU2 PG340X3CS-4KU2 Rotary Rotary Rotary TOSHIBA TOSHIBA GD Toshiba Btu/h 18083 20800 20800 W 1760 1970 1970 A 8.5 9.2 9.2 A 40 Internal UP3SE0391-T09 UP3SE0391-T09 50 50 uF 35UF/370V 850 850 ml 750 RPG25 RPG25 RPG25 WELLING WELLING WELLING 53 53 W 53 1.5 1.5 uF 1.5uF/450V r/min 1260/1100/1000 1260/1100/1000 1260/1100/1000 800/770/740 800/770/740 800/770/740 m3/h 41/37/35 41/37/35 dB(A) 42/40/38 YDK36-6 YDK53-6KB YDK53-6KB WELLING WELLING WELLING 96 150 150 W 2.5F/450V 3.0F/450V 3.0F/450V uF 900 840 840 r/min 3 1900 2300 2300 m /h dB(A) 53 53 53 2100 2200 g 2100 2.8 2.8 MPa 2.8 mm 6.35/12.7 6.35/12.7 6.35/12.7 m 15 20 20 m 8 10 10 17-30 17-30 17-30 -7 - 45 18-45 -7 - 45 2 30-40 34-49 34-49 m
Note:
The noise date is base on hemi-anechoic chamber, during actual operation; these values are normally somewhat different as a result of ambient condition. The above design and specifications are subject to change without prior notice for product improvement.
- 10 -
Service manual
5. Refrigerant cycle diagram
Cooling only
Heat pump mode
- 11 -
Service manual
6. Operation limits
6.1 Cooling operation
Outdoor unit air temp. DB
Indoor air temp. DB Note: The chart is the result from the continuous operation under constant air temperature conditions. However, excludes the initial pull-down stage.
6.2 Heating operation
Indoor air temp. DB
Outdoor unit air temp. DB Note: The chart is the result from the continuous operation under constant air temperature conditions. However, excludes the initial pull-down stage.
- 12 -
Service manual
7. Schematic diagram and Wiring diagram
7.1 Schematic diagram
- 13 -
Service manual
7.2
Wiring diagram
7.2.1 Cooling mode MSG-07CR, MSG-09CR, MSG-12CR
INDOOR UNIT O U T D O O R U N I T
1 2 ( N )
YG B L A C K B L A C K O V E R L O A D R E L A Y B L A C K C O M P R E S S O R C YG S R E D R B L U E YG F A N M O T O R R E D R E D R E D
B L U E
COMPRESSOR CAPACITOR
FAN CAPACITOR
- 14 -
Service manual
MSG-16CR
INDOOR UNIT O U T D O O R U N I T
1 2 ( N )
YG B L A C K B L A C K O V E R L O A D R E L A Y B L A C K C O M P R E S S O R C YG S R E D R B L U E YG F A N M O T O R R E D R E D R E D
B L U E
COMPRESSOR CAPACITOR
FAN CAPACITOR
- 15 -
Service manual
MSG-18CR, MSG-21CR
TRANSFORMER
COMPRESSOR RELAY
BLUE WHITE BROWN
SWITCH BOARD
CN9
DISPLAY BOARD
CN4 CURRENT DETECTOR
CN14 CN2
CN12
CN8 CN7
AMBIENT SENSOR HEAT EXCHANGER SENSOR
CN10
LOUVER MOTOR
INDOOR UNIT O U T D O O R U N I T
1 2 ( N )
YG B L A C K B L A C K O V E R L O A D R E L A Y B L A C K C O M P R E S S O R C YG S R E D R B L U E YG F A N M O T O R R E D R E D R E D
B L U E
COMPRESSOR CAPACITOR
FAN CAPACITOR
- 16 -
LOUVER MOTOR
INDOOR MOTOR
BLACK
WHITE
CN6
CN5
CN1
Service manual
7.2.2 MSG-07HR, MSG-09HR, MSG-12HR
- 17 -
Service manual
MSG-16HR, MSG-18HR, MSG-21HR
- 18 -
Service manual
8. Installation details
8.1 Wrench torque sheet for installation
Outside diameter mm 6.35 9.52 12.7 15.88 19.05 inch 1/4 3/8 1/2 5/8 3/4 Torque Kg.m 1.8 4.2 5.5 6.6 6.6
8.2
Connecting the cables
Grade
The power cord of connect should be selected according to the following specifications sheet.
Unit mm2 7K 1.0 9K 1.0 12K 1.5 18K 2.5 24K 2.5 28K 2.5
8.3
Pipe length and the elevation
Pipe size GAS 3/8'' (9.52) 1/2'' (12.7) 1/2'' (12.7) 5/8'' (15.88) 5/8'' (15.88) 5/8'' (15.88) 3/4'' (19.05) LIQUID 1/4'' (6.35) 1/4'' (6.35) 1/4'' (6.35) 1/4'' (6.35) 3/8'' (9.52) 3/8'' (9.52) 3/8'' (9.52) Standard length (m) Max. Elevation B (m) 5 5 8 10 10 15 15 Max. Elevation A (m) 10 10 15 20 20 30 30 Additional refrigerant (g/m) 30 30 30 30 65 65 65
Capacity Btu/h 7k~12K 16K~28K 30K~36K
5 5 5 5 5 5 5
In case that more than 5
Caution: Capacity is base on standard length and maximum allowance length is base of reliability. Oil trap should be install per 5-7 meters.
- 19 -
Service manual
8.4
Air purging of the piping and indoor unit
Required tools: Hexagonal wrench; adjustable wrench; torque wrenches, wrench to hold the joints and gas leak detector. Note: The air in the indoor unit and in the piping must be purged. If air remains in the refrigeration piping, it will affect the compressor, reduce the cooling capacity, and could lead to a malfunction of unit. Be sure, using a torque wrench to tighten the service port cap (after using the service port), so that it prevents the gas leakage from the refrigeration cycle.
Procedure 1. Recheck the piping connections. 2. Open the valve stem of the 2-way valve counterclockwise approximately 90', wait 10 seconds, and then set it to closed position. Be sure to use a hexagonal wrench to operate the valve stem 3. Check for gas leakage. Check the flare connection for gas leakage 4. Purge the air from the system. Set the 2-way valve to the open position and remove the cap from the 3-way valve's service port. Using the hexagonal wrench to press the valve core pin, discharge for three seconds and then wait for one minute. 5. Use torque wrench to tighten the service port cap to a torque of 1.8 kg.m. (18n.m) 6. Set the 3-way valve to the opened position.
- 20 -
7. Mounted the valve stem nuts to the 2-way and 3-way valves. 8. Check for gas leakage. At this time, especially check for gas leakage from the 2-way and 3-way stem nuts, and from the service port. Caution: If gas leakage is discovered in step (3) above, take the following measures. If the leaks stop when the piping connections are tightened further, continue working from step (4). If the gas leaks do not stop when the connections are retightened, repair the location of the leak, discharge all of the gas through the service port, and then recharge with the specified amount of gas from a gas cylinder.
Service manual
8.5
Pumping down (Re-installation)
Procedure 1. Confirm that both the 2-way and 3-way valves are set to the opened position. Remove the valve stem caps and confirm that the valve stems are in the opened position. Be sure to use a hexagonal wrench to operate the valve stems. 2. Operate the unit for 10 to 15 minutes. 3. Stop operation and wait for 3 minutes, then connect the charge set to the service port of the 3-way valve. Connect the charge hose with the push pin to the gas service port. 4. Air purging of the charge hose. Open the low-pressure valve on the charge set slightly to purge air from the charge hose. 5. Set the 2-way valve to the close position. 6. Operate the air conditioner at the cooling cycle and stop it when the gauge indicates 0.1MPa. 7. Immediately set the 3-way valve to the closed position. Do this quickly so that the gauge ends up indicating 0.3 to 0.5Mpa. 8. Disconnect the charge set, and amount the 2-way and 3-way valve's stem nuts and service port caps. Use a torque wrench to tighten the service port cap to a torque of 1.8 kg.m. Be sure to check for gas leakage.
- 21 -
Service manual
8.6
Re-air purging (Re-installation)
Procedure: 1. Confirm that both the 2-way and 3-way valves are set to the closed position. 2. Connect the charge set and a charging cylinder to the service port of the 3-way valve. Leave the valve on the charging cylinder closed. 3. Air purging. Open the valves on the charging cylinder and the charge set. Purge the air by loosening the flare nut on the 2-way valve approximately 45' for 3 seconds then closing it for 1 minutes; repeat 3 times. After purging the air, use a torque wrench to tighten the flare nut to on the 2-way valve. 4. Check the gas leakage. Check the flare connections for gas leakage. 5. Discharge the refrigerant. Close the valve on the charging cylinder and discharge the refrigerant until the gauge indicate 0.3 to 0.5 Mpa. 6. Disconnect the charge set and the charging cylinder, and set the 2-way and 3-way valves to the open position. Be sure to use a hexagonal wrench to operate the valve stems. 7. Mount the valve stems nuts and the service port cap. Be sure to use a torque wrench to tighten the service port cap to a torque 18N.m. Be sure to check the gas leakage.
- 22 -
Service manual
8.7
Balance refrigerant of the 2-way, 3-way valves
Procedure: 1. Confirm that both the 2-way and 3-way valves are set to the open position. 2. Connect the charge set to the 3-way valve's service port. Leave the valve on the charge set closed. Connect the charge hose with the push pin to the service port. 3. Open the valves (Low side) on the charge set and discharge the refrigerant until the gauge indicates 0.05 to 0.1 Mpa. If there is no air in the refrigeration cycle [the pressure when the air conditioner is not running is higher than 0.1Mpa, discharge the refrigerant until the gauge indicates 0.05 to 0.1 Mpa. If this is the case, it will not be necessary to apply a evacuation. Discharge the refrigeration gradually; if it is discharged too suddenly, the refrigeration oil sill be discharged.
- 23 -
Service manual
8.8
Evacuation
Procedure: 1. Connect the vacuum pump to the charge set's centre hose. 2. Evacuation for approximately one hour. Confirm that the gauge needle has moved toward -0.1 Mpa (-76 cmHg) [vacuum of 4 mmHg or less]. 3. Close the valve (Low side) on the charge set, turn off the vacuum pump, and confirm that the gauge needle does not move (approximately 5 minutes after turning off the vacuum pump). 4. Disconnect the charge hose from the vacuum pump. Vacuum pump oil, if the vacuum pump oil becomes dirty or depleted, replenish as needle.
- 24 -
Service manual
8.9
Gas charging
Procedure: 1. Connect the charge hose to the charging cylinder. Connect the charge hose which you disconnected from the vacuum pump to the valve at the bottom of the cylinder. 2. Purge the air from the charge hose. Open the valve at the bottom of the cylinder and press the check valve on the charge set to purge the air (be careful of the liquid refrigerant). 3. Open the valves (Low side) on the charge set and charge the system with liquid refrigerant. If the system cannot be charge with the specified amount of refrigerant, if can be charged with a little at a time (approximately 150g each time0 while operating the air conditioner in the cooling cycle; however, one time is not sufficient, wait approximately 1 minute and then repeat the procedure.(pumping down-pin). 4. Immediately disconnect the charge hose from the 3-way valve's service port. Stopping partway will allow the refrigerant to be discharged. If the system has been charged with liquid refrigerant while operating the air conditioner, turn off the air conditioner before disconnecting the hose. 5. Mounted the valve stem caps and the service port Use torque wrench to tighten the service port cap to a torque of 18N.m. Be sure to check for gas leakage.
- 25 -
Service manual
9. Capacity table
9.1 MSG-07CRN2
OUTDOOR TEMPERATURE DRY 25ºC 1.97 1.44 0.67 2.13 1.57 0.69 2.27 1.73 0.71 2.53 1.95 0.74 30ºC 1.85 1.38 0.70 2.04 1.52 0.73 2.17 1.67 0.75 2.43 1.89 0.78 35ºC 1.71 1.29 0.73 1.90 1.45 0.76 2.05 1.60 0.78 2.35 1.84 0.81 40ºC 1.58 1.20 0.79 1.80 1.38 0.82 1.94 1.52 0.84 2.18 1.72 0.88 45ºC 1.47 1.13 0.88 1.68 1.29 0.91 1.81 1.42 0.94 2.00 1.60 0.97 50ºC 1.37 1.05 0.91 1.55 1.20 0.94 1.66 1.32 0.97 1.88 1.52 1.01 SUMMER Cooling mode Indoor Conditions 21ºC D Total capacity kW 15ºC W Sensitive capacity kW Input kW. 24ºC D Total capacity kW 17ºC W Sensitive capacity kW Input kW. 27ºC D Total capacity kW 19ºC W Sensitive capacity kW Input kW. 32ºC D Total capacity kW 23ºC W Sensitive capacity kW Input kW.
9.2
MSG-07HRN2
OUTDOOR TEMPERATURE DRY 25ºC 1.97 1.44 0.67 2.13 1.57 0.69 2.27 1.73 0.71 2.53 1.95 0.74 30ºC 1.85 1.38 0.70 2.04 1.52 0.73 2.17 1.67 0.75 2.43 1.89 0.78 35ºC 1.71 1.29 0.73 1.90 1.45 0.76 2.05 1.60 0.78 2.35 1.84 0.81 40ºC 1.58 1.20 0.79 1.80 1.38 0.82 1.94 1.52 0.84 2.18 1.72 0.88 45ºC 1.47 1.13 0.88 1.68 1.29 0.91 1.81 1.42 0.94 2.00 1.60 0.97 50ºC 1.37 1.05 0.91 1.55 1.20 0.94 1.66 1.32 0.97 1.88 1.52 1.01
SUMMER Cooling mode Indoor Conditions 21ºC D Total capacity kW 15ºC W Sensitive capacity kW Input kW. 24ºC D Total capacity kW 17ºC W Sensitive capacity kW Input kW. 27ºC D Total capacity kW 19ºC W Sensitive capacity kW Input kW. 32ºC D Total capacity kW 23ºC W Sensitive capacity kW Input kW.
WINTER Indoor Conditions 15ºC 18ºC 20ºC 22ºC Capacity kW Input kW. Capacity kW Input kW. Capacity kW Input kW. Capacity kW Input kW.
OUTDOOR CONDITIONS 12ºC D 7ºC D 4ºC D 11ºC W 6ºC W 3ºC W 2.76 2.42 2.22 0.86 0.78 0.73 2.71 2.38 2.16 0.88 0.79 0.74 2.34 2.69 2.14 0.80 0.91 0.76 2.66 2.31 2.11 0.94 0.81 0.77
0ºC D -1ºC W 1.95 0.67 1.88 0.69 1.83 0.70 1.81 0.73
-4ºC D -6ºC W 1.68 0.59 1.59 0.60 1.51 0.62 1.48 0.66
-7ºC D -8ºC W 1.47 0.53 1.38 0.54 1.25 0.57 1.23 0.59
- 26 -
Service manual
9.3
MSG-09CRN2
OUTDOOR TEMPERATURE DRY 25ºC 2.50 1.82 0.86 2.71 1.99 0.88 2.88 2.19 0.91 3.21 2.47 0.95 30ºC 2.35 1.75 0.90 2.58 1.93 0.93 2.75 2.12 0.96 3.08 2.40 1.00 35ºC 2.17 1.64 0.94 2.42 1.84 0.97 2.60 2.03 1.00 2.98 2.34 1.04 40ºC 2.00 1.52 1.02 2.28 1.75 1.05 2.46 1.93 1.08 2.77 2.19 1.12 45ºC 1.87 1.43 1.13 2.13 1.64 1.16 2.29 1.80 1.20 2.53 2.02 1.25 50ºC 1.73 1.34 1.17 1.96 1.52 1.20 2.11 1.67 1.24 2.38 1.93 1.29
SUMMER Cooling mode Indoor Conditions 21ºC D Total capacity kW 15ºC W Sensitive capacity kW Input kW. 24ºC D Total capacity kW 17ºC W Sensitive capacity kW Input kW. 27ºC D Total capacity kW 19ºC W Sensitive capacity kW Input kW. 32ºC D Total capacity kW 23ºC W Sensitive capacity kW Input kW.
9.4
MSG-09HRN2
OUTDOOR TEMPERATURE DRY 25ºC 2.50 1.82 0.86 2.71 1.99 0.88 2.88 2.19 0.91 3.21 2.47 0.95 30ºC 2.35 1.75 0.90 2.58 1.93 0.93 2.75 2.12 0.96 3.08 2.40 1.00 35ºC 2.17 1.64 0.94 2.42 1.84 0.97 2.60 2.03 1.00 2.98 2.34 1.04 40ºC 2.00 1.52 1.02 2.28 1.75 1.05 2.46 1.93 1.08 2.77 2.19 1.12 0ºC D -1ºC W 2.68 0.92 2.58 0.95 2.52 0.97 2.48 1.01 45ºC 1.87 1.43 1.13 2.13 1.64 1.16 2.29 1.80 1.20 2.53 2.02 1.25 -4ºC D -6ºC W 2.31 0.81 2.19 0.83 2.07 0.85 2.04 0.91 50ºC 1.73 1.34 1.17 1.96 1.52 1.20 2.11 1.67 1.24 2.38 1.93 1.29 -7ºC D -8ºC W 2.03 0.73 1.90 0.74 1.72 0.78 1.69 0.81
SUMMER Cooling mode Indoor Conditions 21ºC D Total capacity kW 15ºC W Sensitive capacity kW Input kW. 24ºC D Total capacity kW 17ºC W Sensitive capacity kW Input kW. 27ºC D Total capacity kW 19ºC W Sensitive capacity kW Input kW. 32ºC D Total capacity kW 23ºC W Sensitive capacity kW Input kW. WINTER Indoor Conditions 15ºC 18ºC 20ºC 22ºC Capacity kW Input kW. Capacity kW Input kW. Capacity kW Input kW. Capacity kW Input kW.
OUTDOOR CONDITIONS 12ºC D 7ºC D 4ºC D 11ºC W 6ºC W 3ºC W 3.80 3.33 3.05 1.18 1.07 1.00 3.73 3.27 2.98 1.21 1.09 1.01 3.22 3.70 2.94 1.10 1.25 1.05 3.66 3.18 2.90 1.29 1.11 1.06
- 27 -
Service manual
9.5
MSG-12CRN2
OUTDOOR TEMPERATURE DRY 25ºC 3.36 2.46 1.14 3.64 2.68 1.17 3.88 2.95 1.21 4.32 3.33 1.26 30ºC 3.16 2.36 1.20 3.48 2.59 1.24 3.71 2.85 1.28 4.14 3.23 1.33 35ºC 2.93 2.21 1.25 3.25 2.47 1.29 3.50 2.73 1.33 4.01 3.15 1.38 40ºC 2.69 2.05 1.35 3.07 2.35 1.39 3.31 2.60 1.44 3.73 2.94 1.49 45ºC 2.52 1.92 1.50 2.86 2.21 1.55 3.08 2.43 1.60 3.41 2.73 1.66 50ºC 2.33 1.80 1.55 2.64 2.05 1.60 2.84 2.25 1.65 3.21 2.60 1.72
SUMMER Cooling mode Indoor Conditions 21ºC D Total capacity kW 15ºC W Sensitive capacity kW Input kW. 24ºC D Total capacity kW 17ºC W Sensitive capacity kW Input kW. 27ºC D Total capacity kW 19ºC W Sensitive capacity kW Input kW. 32ºC D Total capacity kW 23ºC W Sensitive capacity kW Input kW.
9.6
MSG-12HRN2
OUTDOOR TEMPERATURE DRY 25ºC 3.36 2.46 1.14 3.64 2.68 1.17 3.88 2.95 1.21 4.32 3.33 1.26 30ºC 3.16 2.36 1.20 3.48 2.59 1.24 3.71 2.85 1.28 4.14 3.23 1.33 35ºC 2.93 2.21 1.25 3.25 2.47 1.29 3.50 2.73 1.33 4.01 3.15 1.38 40ºC 2.69 2.05 1.35 3.07 2.35 1.39 3.31 2.60 1.44 3.73 2.94 1.49 45ºC 2.52 1.92 1.50 2.86 2.21 1.55 3.08 2.43 1.60 3.41 2.73 1.66 50ºC 2.33 1.80 1.55 2.64 2.05 1.60 2.84 2.25 1.65 3.21 2.60 1.72
SUMMER Cooling mode Indoor Conditions 21ºC D Total capacity kW 15ºC W Sensitive capacity kW Input kW. 24ºC D Total capacity kW 17ºC W Sensitive capacity kW Input kW. 27ºC D Total capacity kW 19ºC W Sensitive capacity kW Input kW. 32ºC D Total capacity kW 23ºC W Sensitive capacity kW Input kW. WINTER Indoor Conditions 15ºC 18ºC 20ºC 22ºC Capacity kW Input kW. Capacity kW Input kW. Capacity kW Input kW. Capacity kW Input kW.
OUTDOOR CONDITIONS 12ºC D 7ºC D 4ºC D 11ºC W 6ºC W 3ºC W 4.87 4.27 3.92 1.50 1.37 1.27 4.78 4.20 3.82 1.54 1.39 1.29 4.13 4.74 3.77 1.40 1.58 1.33 4.70 4.08 3.72 1.64 1.41 1.35
0ºC D -1ºC W 3.44 1.18 3.31 1.21 3.23 1.23 3.19 1.28
-4ºC D -6ºC W 2.96 1.02 2.81 1.05 2.66 1.09 2.61 1.15
-7ºC D -8ºC W 2.60 0.93 2.43 0.94 2.21 0.99 2.16 1.03
- 28 -
Service manual
9.7
MSG-16CRN2
OUTDOOR TEMPERATURE DRY 25ºC 4.50 3.28 1.56 4.87 3.58 1.61 5.19 3.94 1.66 5.78 4.45 1.72 30ºC 4.23 3.15 1.64 4.65 3.47 1.69 4.96 3.82 1.75 5.54 4.32 1.82 35ºC 3.91 2.95 1.71 4.35 3.30 1.77 4.68 3.65 1.82 5.36 4.21 1.89 40ºC 3.60 2.74 1.85 4.11 3.14 1.91 4.42 3.47 1.97 4.98 3.94 2.04 45ºC 3.36 2.57 2.05 3.83 2.95 2.12 4.12 3.25 2.18 4.55 3.64 2.27 50ºC 3.12 2.40 2.12 3.53 2.74 2.19 3.80 3.00 2.26 4.29 3.48 2.35
SUMMER Cooling mode Indoor Conditions 21ºC D Total capacity kW 15ºC W Sensitive capacity kW Input kW. 24ºC D Total capacity kW 17ºC W Sensitive capacity kW Input kW. 27ºC D Total capacity kW 19ºC W Sensitive capacity kW Input kW. 32ºC D Total capacity kW 23ºC W Sensitive capacity kW Input kW.
9.8
MSG-16HRN2
OUTDOOR TEMPERATURE DRY 25ºC 4.50 3.28 1.56 4.87 3.58 1.61 5.19 3.94 1.66 5.78 4.45 1.72 30ºC 4.23 3.15 1.64 4.65 3.47 1.69 4.96 3.82 1.75 5.54 4.32 1.82 35ºC 3.91 2.95 1.71 4.35 3.30 1.77 4.68 3.65 1.82 5.36 4.21 1.89 40ºC 3.60 2.74 1.85 4.11 3.14 1.91 4.42 3.47 1.97 4.98 3.94 2.04 45ºC 3.36 2.57 2.05 3.83 2.95 2.12 4.12 3.25 2.18 4.55 3.64 2.27 50ºC 3.12 2.40 2.12 3.53 2.74 2.19 3.80 3.00 2.26 4.29 3.48 2.35
SUMMER Cooling mode Indoor Conditions 21ºC D Total capacity kW 15ºC W Sensitive capacity kW Input kW. 24ºC D Total capacity kW 17ºC W Sensitive capacity kW Input kW. 27ºC D Total capacity kW 19ºC W Sensitive capacity kW Input kW. 32ºC D Total capacity kW 23ºC W Sensitive capacity kW Input kW. WINTER Indoor Conditions 15ºC 18ºC 20ºC 22ºC Capacity kW Input kW. Capacity kW Input kW. Capacity kW Input kW. Capacity kW Input kW.
OUTDOOR CONDITIONS 12ºC D 7ºC D 4ºC D 11ºC W 6ºC W 3ºC W 6.22 5.45 5.00 1.78 1.62 1.51 6.10 5.35 4.87 1.83 1.65 1.53 5.27 6.05 4.82 1.66 1.88 1.58 5.99 5.21 4.74 1.94 1.68 1.60
0ºC D -1ºC W 4.39 1.39 4.23 1.43 4.13 1.46 4.07 1.52
-4ºC D -6ºC W 3.77 1.22 3.59 1.25 3.39 1.29 3.34 1.37
-7ºC D -8ºC W 3.32 1.10 3.11 1.12 2.81 1.18 2.76 1.22
- 29 -
Service manual
9.9
MSG-18CRN2
OUTDOOR TEMPERATURE DRY 25ºC 4.79 3.50 1.62 5.18 3.81 1.67 5.52 4.19 1.72 6.15 4.73 1.79 30ºC 4.50 3.35 1.71 4.95 3.69 1.76 5.27 4.06 1.81 5.90 4.60 1.89 35ºC 4.16 3.14 1.78 4.63 3.52 1.83 4.98 3.88 1.89 5.70 4.48 1.97 40ºC 3.83 2.91 1.92 4.37 3.34 1.98 4.71 3.69 2.04 5.30 4.19 2.12 45ºC 3.58 2.74 2.13 4.08 3.14 2.20 4.39 3.46 2.27 4.85 3.88 2.36 50ºC 3.32 2.56 2.20 3.76 2.91 2.27 4.04 3.19 2.34 4.57 3.70 2.44
SUMMER Cooling mode Indoor Conditions 21ºC D Total capacity kW 15ºC W Sensitive capacity kW Input kW. 24ºC D Total capacity kW 17ºC W Sensitive capacity kW Input kW. 27ºC D Total capacity kW 19ºC W Sensitive capacity kW Input kW. 32ºC D Total capacity kW 23ºC W Sensitive capacity kW Input kW.
9.10 MSG-18HRN2
SUMMER Cooling mode Indoor Conditions 21ºC D Total capacity kW 15ºC W Sensitive capacity kW Input kW. 24ºC D Total capacity kW 17ºC W Sensitive capacity kW Input kW. 27ºC D Total capacity kW 19ºC W Sensitive capacity kW Input kW. 32ºC D Total capacity kW 23ºC W Sensitive capacity kW Input kW. WINTER Indoor Conditions 15ºC 18ºC 20ºC 22ºC Capacity kW Input kW. Capacity kW Input kW. Capacity kW Input kW. Capacity kW Input kW. OUTDOOR TEMPERATURE DRY 25ºC 4.79 3.50 1.62 5.18 3.81 1.67 5.52 4.19 1.72 6.15 4.73 1.79 30ºC 4.50 3.35 1.71 4.95 3.69 1.76 5.27 4.06 1.81 5.90 4.60 1.89 35ºC 4.16 3.14 1.78 4.63 3.52 1.83 4.98 3.88 1.89 5.70 4.48 1.97 40ºC 3.83 2.91 1.92 4.37 3.34 1.98 4.71 3.69 2.04 5.30 4.19 2.12 45ºC 3.58 2.74 2.13 4.08 3.14 2.20 4.39 3.46 2.27 4.85 3.88 2.36 50ºC 3.32 2.56 2.20 3.76 2.91 2.27 4.04 3.19 2.34 4.57 3.70 2.44
OUTDOOR CONDITIONS 12ºC D 7ºC D 4ºC D 11ºC W 6ºC W 3ºC W 6.57 5.76 5.28 2.04 1.85 1.72 6.45 5.66 5.15 2.09 1.88 1.75 5.57 6.39 5.09 1.90 2.15 1.81 6.34 5.51 5.01 2.23 1.92 1.83
0ºC D -1ºC W 4.64 1.59 4.47 1.64 4.36 1.67 4.30 1.74
-4ºC D -6ºC W 3.99 1.39 3.79 1.43 3.59 1.47 3.53 1.57
-7ºC D -8ºC W 3.51 1.26 3.28 1.28 2.97 1.35 2.92 1.40
- 30 -
Service manual
9.11 MSG-21CRN2
SUMMER Cooling mode Indoor Conditions 21ºC D Total capacity kW 15ºC W Sensitive capacity kW Input kW. 24ºC D Total capacity kW 17ºC W Sensitive capacity kW Input kW. 27ºC D Total capacity kW 19ºC W Sensitive capacity kW Input kW. 32ºC D Total capacity kW 23ºC W Sensitive capacity kW Input kW. OUTDOOR TEMPERATURE DRY 25ºC 5.07 3.70 1.78 5.48 4.03 1.84 5.84 4.44 1.89 6.50 5.01 1.97 30ºC 4.76 3.55 1.88 5.24 3.90 1.94 5.58 4.30 2.00 6.24 4.87 2.08 35ºC 4.41 3.33 1.96 4.90 3.72 2.02 5.27 4.11 2.08 6.03 4.74 2.16 40ºC 4.05 3.08 2.11 4.63 3.54 2.18 4.98 3.91 2.25 5.61 4.43 2.34 45ºC 3.79 2.89 2.35 4.31 3.32 2.42 4.64 3.66 2.50 5.13 4.10 2.60 50ºC 3.52 2.71 2.42 3.98 3.08 2.50 4.28 3.38 2.58 4.83 3.92 2.68
9.12 MSG-21HRN2
SUMMER Cooling mode Indoor Conditions 21ºC D Total capacity kW 15ºC W Sensitive capacity kW Input kW. 24ºC D Total capacity kW 17ºC W Sensitive capacity kW Input kW. 27ºC D Total capacity kW 19ºC W Sensitive capacity kW Input kW. 32ºC D Total capacity kW 23ºC W Sensitive capacity kW Input kW. WINTER Indoor Conditions 15ºC 18ºC 20ºC 22ºC Capacity kW Input kW. Capacity kW Input kW. Capacity kW Input kW. Capacity kW Input kW. OUTDOOR TEMPERATURE DRY 25ºC 5.07 3.70 1.78 5.48 4.03 1.84 5.84 4.44 1.89 6.50 5.01 1.97 30ºC 4.76 3.55 1.88 5.24 3.90 1.94 5.58 4.30 2.00 6.24 4.87 2.08 35ºC 4.41 3.33 1.96 4.90 3.72 2.02 5.27 4.11 2.08 6.03 4.74 2.16 40ºC 4.05 3.08 2.11 4.63 3.54 2.18 4.98 3.91 2.25 5.61 4.43 2.34 45ºC 3.79 2.89 2.35 4.31 3.32 2.42 4.64 3.66 2.50 5.13 4.10 2.60 50ºC 3.52 2.71 2.42 3.98 3.08 2.50 4.28 3.38 2.58 4.83 3.92 2.68
OUTDOOR CONDITIONS 12ºC D 7ºC D 4ºC D 11ºC W 6ºC W 3ºC W 7.60 6.67 6.11 2.63 2.39 2.22 7.46 6.54 5.95 2.70 2.43 2.26 6.44 7.39 5.89 2.45 2.77 2.33 7.32 6.37 5.80 2.87 2.47 2.36
0ºC D -1ºC W 5.36 2.06 5.17 2.11 5.04 2.16 4.97 2.24
-4ºC D -6ºC W 4.61 1.79 4.38 1.85 4.15 1.90 4.08 2.02
-7ºC D -8ºC W 4.05 1.63 3.79 1.65 3.44 1.74 3.38 1.81
- 31 -
Service manual
10. Electronic function
(Just for the 5K, 7K, 9K, 12K, 16K, 18K cooling and heating mode)
10.1 Electronic control working environment
Input voltage: 175~253V Input power frequency:50HZ Ambient temperature: -7°C+43°C Indoor fan normal working amp is less than 1A Outdoor fan normal working amp is less than 1.5A Four-way valve normal working amp is less than 1A Swing motor: DC12V Compressor: single-phase power supply. Its normal working amp is less than 15A
10.2 Proper symbols and their meaning
TA: Indoor ambient temperature TE: Indoor evaporator temperature TS: Setting temperature through the remote controller I3sec: Self-protection amp of compressor, continue three seconds until turns off the compressor. I5MIN: Self-protection amp of compressor, continue five minutes until turns off the compressor. IFAN: Self-protection amp of outdoor fan/indoor fans when they change from higher wind to lower wind. IRESTORE: Amp self-protection return value THDEFROST: High wind, defrosting temperature difference TMDEFROST: Middle wind, defrosting temperature difference TLDEFROST: Low wind, defrosting temperature difference TE1: Anti-cold wind, from Fan Off to Breeze temperature TE2: Anti-cold wind, from Breeze to Setting Fan Speed temperature TE3: Anti-cold wind, from Setting Fan Speed to Breeze temperature TE4: Anti-cold wind, from Breeze to Fan Off temperature TE5: Evaporator low temperature protection entering temperature TE6: Evaporator low temperature protection restoring temperature TE7: Evaporator high temperature protection, compressor off temperature TE8: Evaporator high temperature protection, fan off temperature TE9: Evaporator high temperature protection, restoring temperature
10.3 Function
Remote receiving Testing and forced running Position set for indoor unit wind vane LED displaying and alarm On or off Timer Protection for the compressor Current protection High temperature protection of indoor heat exchanger at heating mode Auto defrosting and heating recovery at heating mode Anti cold air at heating mode
- 32 -
Service manual
Anti frozen at cooling mode
10.4 Protection
10.4.1 3 minutes delay at restart for compressor. 10.4.2 Sensor protection at open circuit and breaking disconnection 10.4.3 Fan Speed is out of control. When Indoor Fan Speed is too high(higher than High Fan+300RPM)or too low(lower than 400RPM), the unit stops and LED displays failure information and can't returns to normal operation automatically. 10.4.4 Cross Zero signal error warning. If there is no Cross Zero signals in 4 minutes, the unit stops and LED displays failure information and can't returns to normal operation automatically. 10.4.5 The current protection of the compressor
If compressor turns off for continuously 4 times due to current protection in 5 minutes from Compressor On, the unit stops and LED displays failure information and can't returns to normal operation automatically.
10.5 Fan-only mode
Fan speed is high/mid/low/ Auto
10.6 Cooling mode
The 4-way valve is closed at cooling mode. The action of the compressor and the outdoor fan:(T=indoor temperature)
- 33 -
Service manual
Auto fan at cooling mode:
Anti-freezing control to indoor evaporator at cooling mode ( T: evaporator temp. )
Compressor and outdoor fan on
EVAP. temp. down
Compressor and outdoor fan off (after 5 mins)
EVAP. temp. up
TE5
TE6
T
10.7 Dehumidifying mode
10.7.1 The 4-way valve is off in dehumidifying mode 10.7.2 Compressor and Indoor Fan actions in dehumidifying mode
C
B
A
0
2
TA-TS
- 34 -
Service manual
Block A B C
Indoor Fan LOW BREEZE LOW BREEZE LOW BREEZE
Compressor and Outdoor Fan ON 6minutes OFF 4minutes ON 5minutes OFF 5minutes ON 4minutes OFF 6minutes
Repeat on and off cycle. 10.7.3 Low room temperature protection: When room temperature decreases to below 10, compressor and outdoor fan will stop(indoor fan is Breeze). Dehumidifying operation will be resumed when room temperature restores to over 13. 10.7.4 At dehumidifying mode, the anti-freezing function of the indoor heat exchanger is the same as that of cooling mode. 10.7.5 At dehumidifying mode, the action of fans of indoor is the same as that of air-only mode.
10.8 Heating mode
10.8.1 Generally, the 4-way valve is open in heating mode, but it is closed in defrosting mode. 4-way valve must delay 2 minutes compared with compressor if the compressor changed into non-heating mode or turned off. 4-way valve doesn't delay in dehumidifying mode 10.8.2 Generally, the outdoor fan is turned off with the on-off action of compressor in heating mode, except for the defrosting mode or the end of defrost 10.8.3 Action of compressor and outdoor fan motor at heating mode: compressor must run for 7 minutes after starting and then judge temperature. Meanwhile other protections are still valid.
* This parameter can be changed from 0 to 3 10.8.4 Indoor Fan actions at heating mode Indoor Fan can be set at HIGH/MID/LOW/AUTO by using a remote controller, but Anti-cold wind function prevails. Anti-cold wind control function at heating mode (T=indoor exchanger temp.)
- 35 -
Service manual
10.8.5 Auto wind at heating mode (T=indoor temp.)
10.8.6 Indoor evaporator high-temperature protection at heating mode (T=indoor exchanger temp.)
10.8.7 The louver opens to Standard Angle ANGLHEAT when power is on for the first time
10.9 Defrosting mode(available for heating mode)
Defrosting condition: Defrosting starts when either of the following &: A and B are satisfied: A: The compressor keeps running for 40 minutes or more. B: The temperature difference of evaporator and room temperature meets one of the following:
- 36 -
Service manual
Calculate from the end of latest defrost, evaporator high temp. Protection only closes outdoor fan with the compressor still running. Add up to 90 minutes. Defrosting time At condition , If item B is satisfied before item A, it would be regarded as severe frosting and the defrosting time is 10 minutes. If item B is satisfied after item A, the defrosting time is 6minutes. At condition , the defrosting time is 10 minutes. After three times continuous 6-minute defrost, the fourth defrost time should be 10 minutes. The circulation is as following:
Ending condition of defrosting If one of following conditions is satisfied, end the defrost and turn into heating mode: A. The defrost time has reached to 6 or 10 minutes. B. The compressor current has reached to IDEFROST or above, IDEROST differs in different models Defrosting Actions
Defrost 10 or 6 minutes Compressor 25s 5s 4-way valve 2s Outdoor fan
Indoor fan 10s
10.10 Auto mode
10.10.1 The air conditioner automatically selects one of the following operation modes: cooling, heating or fan only according to the temperature difference between room temperature (TA) and set temperature (TS).
- 37 -
Service manual
10.10.2 The indoor fan blows automatically in corresponding selected mode 10.10.3 The motion of indoor fan's blade should accord with the selected operation mode 10.10.4 One mode should be carried out for at least 15 minutes once selected. If the compressor cannot start for 15 minutes, reselect the operation mode according to the room temp. and set temp., or reselect when the set temp. varies
10.11 Force cooling function
10.11.1 Select forced cooling function with the forced cooling button or the switch 10.11.2 The compressor is unconditionally turned on, after 30 minutes cooling operation whose fan mode is set as low, the A/C operates at the DRY mode with a set temp. of 24 10.11.3 All protections of remote control cooling are available at forced cooling operation 10.11.4 Forced Auto function Select forced auto function with the forced auto button or the switch. In forced auto status the A/C operates at remote control mode with a set temp. of 24
10.12 Sleep mode
10.12.1 The sleep function is available at cooling, heating or auto mode 10.12.2 Cooling: The set temperature rise 1 per hour. Two hours later, the set temperature will maintain as a constant and the fan speed is kept at low speed.
10.12.3 Heating: The set temperature decrease 1 per hour. Two hours later, the set temperature will maintain as a constant and the air circulation is kept at low speed (Anti-cold function takes precedence over all).
- 38 -
Service manual
10.12.4 Auto: After an hour running under economic mode, the set temp will rise 1,if it is under cooling mode; the set temp will decrease 1,if it is under heating mode; the set temp will be changeless, if it is under fan-only mode; the condition will be the same after the air conditioner running under economic mode after 2 hours, and during the next time the set temp do not change. The total time is 7 hours, after 7 hours the unit stops.
10.13 Auto restart function
In case of a sudden power failure, this function automatically sets the unit to previous settings before the power failure when power returns
10.14 Anion (optional)
Starts with indoor fan.
- 39 -
Service manual
11. Model and Parameters
Model I3SEC [A] I5MIN [A] IFAN [A] IRESTORE [A] IDEFROST [A] TE1 ['C] TE2 ['C] TE3 ['C] TE4 ['C] TE5 ['C] TE6 ['C] TE7 ['C] TE8 ['C] TE9 ['C] ANGLCOOL ['] ANGLHEAT ['] ANGLOFF ['] THDEFROST ['] TMDEFROST TLDEFROST ['] [']
MSG-07CR 8.5 6.2 5.2 4.2 MSG-07HR 8.5 6.2 5.2 4.2 3.2 28 32 30 26 2 7 60 53 50 200° 0° 124° 16°C 17°C 18°C MSG-09CR 10 7.5 5.5 4.5 MSG-09HR 10 7.5 5.5 4.5A 3.5 28 32 30 26 2 7 60 53 50 200° 0° 124° 14°C 15°C 16°C MSG-12CR 11 10 8 6 MSG-12HR 11 10 8 6 5.5 28 32 30 20 3 8 60 53 50 200° 0° 124° 14°C 15°C 16°C
2 7
2 7
3 8
200° 124°
200° 124°
200° 124°
Model I3SEC [A] I5MIN [A] IFAN [A] IRESTORE [A] IDEFROST [A] TE1 ['C] TE2 ['C] TE3 ['C] TE4 ['C] TE5 ['C] TE6 ['C] TE7 ['C] TE8 ['C] TE9 ['C] ANGLCOOL ['] ANGLHEAT ['] ANGLOFF ['] THDEFROST ['] TMDEFROST ['] TLDEFROST [']
MSG-16CR 16 13 11 9.5
MSG-16HR 16 13 11 9.5 6.5 34 36 30 20
MSG-18CR 16 13 11 9.5
MSG-18HR 16 13 11 9.5 6.5 34 36 30 20
MSG-21CR 17 16 14 12
MSG-21HR 17 16 14 12 7 34 36 30 20
3 10
3 10 60 52 50
3 10
3 10 60 52 50
3 10
3 10 64 56 50
50° 0°
50° 105° 0° 17°C 18°C 19°C
50° 0°
50° 105° 0° 17°C 18°C 19°C
50° 0°
50° 105° 0° 20°C 21°C 22°C
- 40 -
Service manual
12. Troubleshooting
12.1 Display board
Operation The indicator flashes once every second after power is on and illuminates when the air conditioner is in operation. Timer indicator: The indicator illuminates then TIMER is set ON. PRE-DEF. indicator (For cooling & heating mode only) The air conditioner starts defrosting automatically if outdoor unit frosts in heating operating. At this time, PRE-DEF. indicator illuminates. Auto indicator: This indicator flashes when the air conditioner is in AUTO operation. ECON indicator This indicator illuminates while the air conditioner is in economic operation.
- 41 -
Service manual
12.2 Troubleshooting
For cooling mode:
Failure phenomenon Indoor fan speed has been out of control for over 1 minute Indoor room temp. or evaporator sensor is open circuit or short circuit Over current protection of the compressor occurs 4 times EEROM error No over-zero signal r Extinguish Flash at 5Hz Operation lamp X On Timer lamp X On
For heat pump mode:
Failure phenomenon Over current protection of the compressor occurs 4 times Indoor fan speed has been out of control for over 1 minute No over-zero signal Temp. sensor on indoor evaporator is open circuit or short circuit Indoor room temp. sensor is open circuit or short circuit EEROM error r Extinguish Flash at 5Hz Operation lamp X X X On Timer lamp X X Defrosting lamp X X
- 42 -
Service manual
12.3 Diagnostic chart
After energizing, no indicator is lighted and the air conditioner can't be operated.
- 43 -
Service manual
12.4 Resetting phenomenon often occurs during operation.
(That is automatically entering to the status when power is on.) The reason is that the instantaneous voltage of main chip is less than 4.5V. Check according to the following procedure:
12.5 Operation lamp flashes and Timer lamp off.
12.6 Operation lamp flashes and Timer lamp on.
- 44 -
Service manual
12.7 Operation lamp off and Timer lamp flashes
12.8 Operation lamp on and Timer lamp flashes
EEROM error, indoor PCB is defective.
12.9 Operation lamp flashes, Timer lamp flashes .
This is alarm signal when the main chip can't detect over-zero signal. When such failure occurs, the main control board must have fault.
- 45 -
Service manual
13. Characteristic of temperature sensor
Temp. Resistance K Temp. Resistance K Temp. Resistance K -10 62.2756 17 14.6181 44 4.3874 -9 58.7079 18 13.918 45 4.2126 -8 56.3694 19 13.2631 46 4.0459 -7 52.2438 20 12.6431 47 3.8867 -6 49.3161 21 12.0561 48 3.7348 -5 46.5725 22 11.5 49 3.5896 -4 44 23 10.9731 50 3.451 -3 41.5878 24 10.4736 51 3.3185 -2 39.8239 25 10 52 3.1918 -1 37.1988 26 9.5507 53 3.0707 0 35.2024 27 9.1245 54 2.959 1 33.3269 28 8.7198 55 2.8442 2 31.5635 29 8.3357 56 2.7382 3 29.9058 30 7.9708 57 2.6368 4 28.3459 31 7.6241 58 2.5397 5 26.8778 32 7.2946 59 2.4468 6 25.4954 33 6.9814 60 2.3577 7 24.1932 34 6.6835 61 2.2725 8 22.5662 35 6.4002 62 2.1907 9 21.8094 36 6.1306 63 2.1124 10 20.7184 37 5.8736 64 2.0373 11 19.6891 38 5.6296 65 1.9653 12 18.7177 39 5.3969 66 1.8963 13 17.8005 40 5.1752 67 1.83 14 16.9341 41 4.9639 68 1.7665 15 16.1156 42 4.7625 69 1.7055 16 15.3418 43 4.5705 70 1.6469
- 46 -