DCR-VX2100/VX2100E
RMT-811
Ver 1.0 2003. 10
Revision History How to use Acrobat Reader

SECTION 6 ADJUSTMENTS

ADJ

Link
Before starting adjustment
Adjusting items when replacing main parts and boards

VIDEO SECTION ADJUSTMENT
PREPARATIONS BEFORE ADJUSTMENTS SYSTEM CONTROL SYSTEM ADJUSTMENT

CAMERA SECTION ADJUSTMENT
SERVO AND RF SYSTEM ADJUSTMENT PREPARATIONS BEFORE ADJUSTMENT VIDEO SYSTEM ADJUSTMENTS INITIALIZATION OF B,C,D,E,F,8 PAGE DATA AUDIO SYSTEM ADJUSTMENTS CAMERA SYSTEM ADJUSTMENTS COLOR ELECTRONIC VIEWFINDER SYSTEM ADJUSTMENT LCD SYSTEM ADJUSTMENT

SERVICE MODE
ADJUSTMENT REMOTE COMMANDER DATA PROCESS

MECHANISM SECTION ADJUSTMENT
SERVICE MODE

HOW TO ENTER RECORD MODE WITHOUT CASSETTE HOW TO ENTER PLAYBACK MODE WITHOUT CASSETTE TAPE PATH ADJUSTMENT

Contents of LEVEL 2 and LEVEL 3 Service Manual
CONTENTS 1. SERVICE NOTE 2. DISASSEMBLY 3. BLOCK DIAGRAMS 4. PRINTED WIRING BOARDS AND SCHEMATIC DIAGRAMS 5. REPAIR PARTS LIST LEVEL 2 a a LEVEL 3

OVERALL POWER CD-512, JK-267, CK-140, PD-217, LA-028, SE-147, KP-013, VC-358 BOARD, MK-016, MS-209, FK-088, FT-092, MI-050, LB-100, HL-013, FP-594 FLEXIBLE MA-430, DD-216, ZM-030, RM-091 BOARD, FP-194, FP-196, FP-188, FP-189 FLEXIBLE EXPLODED VIEWS ELECTRICAL PARTS a (VC-358 BOARD)

9-876-288-51

Sony EMCS Co.

2003J1600-1 ©2003.10 Published by DI CS Strategy Div.

DCR-VX2100/VX2100E
TABLE OF CONTENTS 6. ADJUSTMENTS
1. Before starting adjustment ··············································· 6-1 1-1. Adjusting items when replacing main parts and boards. ··· 6-2 6-1. CAMERA SECTION ADJUSTMENT ··························· 6-4 1-1. PREPARATIONS BEFORE ADJUSTMENT (CAMERA SECTION) ··················································· 6-4 1-1-1. List of Service Tools ······················································· 6-4 1-1-2. Preparations ····································································· 6-5 1-1-3. Precaution ········································································ 6-7 1. Setting the Switch ···························································· 6-7 2. Order of Adjustments ······················································ 6-7 3. Subjects ··········································································· 6-7 1-2. INITIALIZATION OF B, C, D, E, F, 8 PAGE DATA ····· 6-8 1-2-1. INITIALIZATION OF C, D, 8 PAGE DATA ·················· 6-8 1. Initializing the C, D, 8 Page Data ···································· 6-8 2. Modification of C, D, 8 Page Data ·································· 6-8 3. C Page Table ···································································· 6-8 4. D Page Table ·································································· 6-10 5. 8 Page Table ··································································· 6-10 1-2-2. INITIALIZATION OF B PAGE DATA ························· 6-11 1. Initializing the B Page Data ··········································· 6-11 2. Modification of B Page Data ········································· 6-11 3. B Page Table ·································································· 6-11 1-2-3. INITIALIZATION OF E, F PAGE DATA ····················· 6-12 1. Initializing the E, F Page Data ······································· 6-12 2. Modification of E, F Page Data ····································· 6-12 3. F Page Table ·································································· 6-12 4. E Page Table ·································································· 6-14 1-3. CAMERA SYSTEM ADJUSTMENTS ························ 6-15 1. 27MHz Origin Oscillation Adjustment (VC-358 board) ····························································· 6-15 2. Zoom Key Center Adjustment ······································· 6-15 3. HALL Adjustment ························································· 6-16 4. Offset Adjustment ·························································· 6-16 5. Flange Back Adjustment (Using Minipattern Box) ······· 6-17 6. Flange Back Adjustment (Using Flange Back Adjustment Chart and Subject More Than 500m Away) ·················· 6-18 6-1. Flange Back Adjustment (1) ·········································· 6-18 6-2. Flange Back Adjustment (2) ·········································· 6-18 7. Flange Back Check ························································ 6-19 8. Picture Frame Setting ···················································· 6-19 9. Pre White Balance Data Input ······································· 6-20 10. Auto White Balance Standard Data Input ····················· 6-20 11. MAX GAIN Adjustment ··············································· 6-21 12. LV Standard Data Input ················································· 6-21 13. White Balance ND Filter 1 Compensation ···················· 6-22 14. White Balance ND Filter 2 Compensation ···················· 6-22 15. Auto White Balance Adjustment ··································· 6-23 16. Color Reproduction Adjustment (ND Filter OFF) ········ 6-23 17. Color Reproduction Adjustment (ND Filter 1) ·············· 6-24 18. Color Reproduction Adjustment (ND Filter 2) ·············· 6-24 19. White Balance Check ···················································· 6-25 20. Steady Shot Adjustment ················································ 6-26 20-1. Steady Shot Adjustment (1) ··········································· 6-27 20-2. Steady Shot Adjustment (2) ··········································· 6-28 1-4. COLOR ELECTRONIC VIEWFINDER SYSTEM ADJUSTMENT ····························································· 6-29 1. VCO Adjustment (VC-358 board) ································ 6-29 2. Bright Adjustment (VC-358 board) ······························· 6-30 3. Contrast Adjustment (VC-358 board) ··························· 6-30 4. White Balance Adjustment (VC-358 board) ················· 6-31 1-5. 1. 2. 3. 4. 5. 6. 7. 8. LCD SYSTEM ADJUSTMENT ··································· 6-31 VCO Adjustment (PD-217 board) ································· 6-32 Bright Adjustment (PD-217 board) ······························· 6-32 Black Limit Adjustment (PD-217 board) ······················ 6-33 PSIG GRAY Adjustment (PD-217 Board) ···················· 6-33 Contrast Adjustment (PD-217 board) ···························· 6-34 Center Level Adjustment (PD-217 board) ····················· 6-34 V-COM Adjustment (PD-217 board) ···························· 6-35 White Balance Adjustment (PD-217 board) ·················· 6-35

6-2. MECHANISM SECTION ADJUSTMENT ·················· 6-36 2-1. HOW TO ENTER RECORD MODE WITHOUT CASSETTE ··································································· 6-36 2-2. HOW TO ENTER PLAYBACK MODE WITHOUT CASSETTE ··································································· 6-36 2-3. TAPE PATH ADJUSTMENT ········································ 6-36 1. Preparation for Adjustment ··········································· 6-36 2. Procedure after operations ············································· 6-36 6-3. VIDEO SECTION ADJUSTMENTS ··························· 6-37 3-1. PREPARATIONS BEFORE ADJUSTMENTS ············ 6-37 3-1-1. Equipment Required ······················································ 6-37 3-1-2. Precautions on Adjusting ··············································· 6-38 3-1-3. Adjusting Connectors ···················································· 6-39 3-1-4. Connecting the Equipment ············································ 6-39 3-1-5. Alignment Tapes ···························································· 6-40 3-1-6. Input/Output Level and Impedance ······························· 6-40 3-2. 1. 2. 2-1. 2-2. 3. 3-3. 1. 2. 3. 4. 5. 5-1. 5-2. 5-3. 5-4. 6. SYSTEM CONTROL SYSTEM ADJUSTMENT ········ 6-41 Initialization of B, C, D, E, F, 8 Page Data ··················· 6-41 Serial No. Input ····························································· 6-41 Company ID Input ························································· 6-41 Serial No. Input ····························································· 6-41 Battery End Adjustment ················································ 6-43 SERVO AND RF SYSTEM ADJUSTMENT ··············· 6-44 Cap FG Duty Adjustment (VC-358 Board) ··················· 6-44 T reel FG Duty Adjustment (VC-358 Board) ················ 6-44 PLL f0 & LPF f0 Adjustment (VC-358 Board) ·············· 6-44 Switching Position Adjustment (VC-242 Board) ·········· 6-45 AGC Center Level and APC & AEQ Adjustment ········· 6-45 Preparations before adjustments ···································· 6-45 AGC Center Level Adjustment (VC-358 Board) ·········· 6-45 APC & AEQ Adjustment (VC-358 Board) ··················· 6-46 Processing after Completing Adjustments ···················· 6-46 PLL f0 & LPF f0 Final Adjustment (VC-358 Board) ····· 6-46

3-4. VIDEO SYSTEM ADJUSTMENTS ····························· 6-47 3-4-1. Base Band Block Adjustments ······································ 6-47 1. Chroma BPF f0 Adjustment (VC-358 Board) ················ 6-47 2. S VIDEO OUT Y Level Adjustment (VC-358 Board) ·· 6-47 3. S VIDEO OUT Chroma Level Adjustment (VC-358 Board) ····························································· 6-48 4. VIDEO OUT Y, Chroma Level Check (VC-358 Board) ····························································· 6-48 3-4-2. BIST Check ·································································· 6-49 1. Playback System Check ················································ 6-49 1-1. Preparations for Playback ·············································· 6-49 1-2. IC301 TRX (RF) PB BIST Check ································· 6-49 1-3. IC301 AUD (ABUS) PB BIST Check ··························· 6-49 1-4. IC301 VFD PB BIST Check ········································· 6-49 1-5. IC301 ENCODER BIST Check ···································· 6-51 1-6. Processing after Completing Playback System Check ···· 6-52 2. Recording System Check ·············································· 6-53 2-1. Preparations for recording ············································· 6-53

--2--

DCR-VX2100/VX2100E

2-2. IC301 TRX (RF) REC BIST Check ····························· 6-53 2-3. Processing after Completing Recording System Check ··· 6-53 3-5. 1. 2. 3. 4. 5. 6-4. 4-1. 1. 2. AUDIO SYSTEM ADJUSTMENTS ···························· 6-54 Playback Level Check ··················································· 6-55 Overall Level Characteristics Check ····························· 6-55 Overall Distortion Check ··············································· 6-55 Overall Noise Level Check ············································ 6-55 Overall Separation Check ·············································· 6-55 SERVICE MODE ·························································· 6-56 ADJUSTMENT REMOTE COMMANDER ················ 6-56 Using the adjustment remote commander ····················· 6-56 Precautions upon using the adjustment remote commander ···································································· 6-56

4-2. DATA PROCESS ··························································· 6-57 4-3. 1. 2. 2-1. 2-2. 3. 4. 5. 6. 7. 8. SERVICE MODE ·························································· 6-58 Setting the Test Mode ···················································· 6-58 Emergence Memory Address ········································ 6-58 EMG Code (Emergency Code) ····································· 6-58 MSW Code ···································································· 6-59 Bit value discrimination ················································ 6-60 Switch check (1) ···························································· 6-60 Switch check (2) ···························································· 6-61 Switch check (3) ···························································· 6-61 Record of Use check ······················································ 6-62 Record of Self-diagnosis check ····································· 6-62

* Color reproduction frame is shown on page 6-63.

--3--

DCR-VX2100/VX2100E SECTION 6 ADJUSTMENTS
1. Before starting adjustment EVR Data Re-writing Procedure When Replacing Board
The data that is stored in the repair board, is not necessarily correct. Perform either procedure 1 or procedure 2 or procedure 3 when replacing board.

Procedure 1
Save the EVR data of the machine in which a board is going to be replaced. Download the saved data after a board is replaced.
(Machine before starting repair) PC PC (Machine after a board is replaced)

Save the EVR data to a personal computer.

Download the saved data to a machine.

Procedure 2
Remove the EEPROM from the board of the machine that is going to be repaired. Install the removed EEPROM to the replaced board.
Remove the EEPROM and install it.

(Former board)

(New board)

Procedure 3
When the data cannot be saved due to defective EEPROM, or when the EEPROM cannot be removed or installed, save the data from the same model of the same destination, and download it.
(Machine to be repaired) PC (Machine to be repaired)

Download the data. Save the data.

(The same model of the same destination)

After the EVR data is saved and downloaded, check the respective items of the EVR data. (Refer to page 6-3 for the items to be checked.)

6-1

DCR-VX2100/VX2100E

1-1. Adjusting items when replacing main parts and boards. · Adjusting items when replacing main parts
When replacing main parts, adjust the items indicated by z in the following table. Note1: When replacing the drum assy., reset the data of page: 2, address: A2 to A4 to "00". (Refer to "Record of Use check" of "5-4. SERVICE MODE") Replaced parts Block replacement Parts replacement

Adjustment Section

Adjustment

Initialization of B, C, D, E, F, 8 page data

Camera

EVF

LCD

Mechanism System control

Servo, RF

Video

Initialization of C, D, 8 page data Initialization of B page data Initialization of E, F page data 27MHz origin oscillation adj. Zoom key center adj. HALL adj. Offset adj. Flange back adj. Pre-white balance data input AWB standard data input MAX GAIN adj. LV standard data input White balance ND filter 1 compensation White balance ND filter 2 compensation Auto white balance adj. Color reproduction adj. (ND filter OFF) Color reproduction adj. (ND filter 1) Color reproduction adj. (ND filter 2) Steady shot adj. VCO adj. Bright adj. Contrast adj. White balance adj. VCO adj. Bright adj. Black limit adj. PSIG GRAY adj. Contrast adj. Center level adj. V COM adj. White balance adj. Tape path adj. Serial No. input Battery end adj. CAP FG duty adj. T reel FG duty adj. Switching position adj. AGC center level adj. APC & AEQ adj. PLL f0 & LPF f0 adj. Chroma BPF f0 adj. S VIDEO OUT Y level adj. S VIDEO OUT Cr, Cb level adj.

z z z z z z z z z z z z z z z z z z z z z z z z z z z z z z z z z z z z z z z z z z z

Lens device Prism assy (Including 3 CCD imagers) VAP unit Mechanism deck EVF block LCD902 (LCD panel) LCD block LCD901 (LCD panel) LCD block ND901 (Fluorescent tube) LCD block Inverter unit Control switch (CF-4980) Mechanism deck M901 (Drum motor) Mechanism deck M902 (Capstan motor) FP-594 board H902 (T reel FG sensor) SE-147 board SE600, 601 (PITCH/YAW sensor) PD-217 board IC2101 (RGB driver (LCD)) PD-217 board IC2103 (Timing generator (LCD)) LB-100 board D201 (Back light (EVF)) VC-358 board IC1802 (RGB driver (EVF)) VC-358 board IC1803 (Timing generator (EVF)) VC-358 board IC705, X701 (Timing generator) VC-358 board IC704 (S/H, AGC) VC-358 board IC706 (A/D converter) VC-358 board IC802 (Camera micro processor) VC-358 board IC1301 (LINE IN/OUT amp) VC-358 board IC301 (DV signal process) VC-358 board IC101 (EQ, A/D CONV., PLL) VC-358 board IC102 (REC/PB amp) VC-358 board IC803 (EVR)
z z z z z z z z z z z z z z z z z z z z z z z z z z z z z z z z z z z z z z z z z z z z z z z z z z z z z z z z z z z z

Table. 6-1-1(1).

6-2

DCR-VX2100/VX2100E

· Adjusting items when replacing a board or EEPROM When replacing a board or EEPROM, adjust the items indicated by z in the following table.
Board replacement

Adjustment Section

Adjustment

CD-512 board FP-594 board VC-358 board SE-147 board PD-217 board LB-100 board VC-358 board VC-358 board VC-358 board
Initialization of B, C, D, E, F, 8 page data Camera EVF LCD Mechanism System control Servo, RF Video Initialization of C, D, 8 page data Initialization of B page data Initialization of E, F page data 27MHz origin oscillation adj. Zoom key center adj. HALL adj. Offset adj. Flange back adj. Pre-white balance data input AWB standard data input MAX GAIN adj. LV standard data input White balance ND filter 1 compensation White balance ND filter 2 compensation Auto white balance adj. Color reproduction adj. (ND filter OFF) Color reproduction adj. (ND filter 1) Color reproduction adj. (ND filter 2) Steady shot adj. VCO adj. Bright adj. Contrast adj. White balance adj. VCO adj. Bright adj. Black limit adj. PSIG GRAY adj. Contrast adj. Center level adj. V COM adj. White balance adj. Tape path adj. Serial No. input Battery end adj. CAP FG duty adj. T reel FG duty adj. Switching position adj. AGC center level adj. APC & AEQ adj. PLL f0 & LPF f0 adj. Chroma BPF f0 adj. S VIDEO OUT Y level adj. S VIDEO OUT Cr, Cb level adj. z z z z z z z z z z z z z z z z z z z z z z z z z z z z z z z z z z z z z z z z z z z z z z z z z z z z z z z z z z z z z z z z z z z z z z z z z z z z z z z z z z z z z z z z z z z z z z z z z z z z z z z z z z z z

(COMPLETE) (COMPLETE) (COMPLETE) (COMPLETE) (COMPLETE) (COMPLETE) IC801 (EEPROM) IC502 (EEPROM) IC1406 (EEPROM)
z z z z z z z z z z z z

Table. 6-1-1(2).

6-3

Supporting

DCR-VX2100/VX2100E

6-1. CAMERA SECTION ADJUSTMENT
1-1. PREPARATIONS BEFORE ADJUSTMENT (CAMERA SECTION)
1-1-1. List of Service Tools · Oscilloscope · Color monitor · Regulated power supply · Digital voltmeter Ref. No. J-1 J-2 J-3 J-4 J-5 J-6 J-7 J-8 J-9 J-10 J-11 J-1 Name Filter for color temperature correction (C14) ND filter 1.0 ND filter 0.3 Pattern box PTB-450 Color chart for pattern box Adjustment remote commander Siemens star chart Clear chart for pattern box CPC-13 jig Extension cable (50P, 0.5mm) Mini pattern box Camera table J-2 J-3 · Vectorscope Parts Code J-6080-058-A Usage

Auto white balance adjustment/check White balance adjustment/check J-6080-808-A White balance check J-6080-818-A White balance check (2 sheets used) J-6082-200-A J-6020-250-A J-6082-053-B J-6080-875-A For checking the flange back J-6080-621-A For adjusting the video section For adjusting the color viewfinder For extension between the CD-512 board (CN100) and J-6082-496-A the VC-358 board (CN025) J-6082-443-A J-6082-353-B For adjusting the flange back J-6082-384-A For adjusting the flange back J-4 J-5

J-6

J-7

J-8

J-9

J-10

J-11

Fig. 6-1-1.

6-4

DCR-VX2100/VX2100E

1-1-2.

Preparations

Note 1: For details of how remove the cabinet and boards, refer to "2. DISASSEMBLY". Note 2: When performing only the adjustments, the lens block and boards need not be disassembled.

Pattern box

1)

Connect the equipment for adjustments according to Fig. 6-1-3.

Note 3: As removing the (upper) handle block (removing the FK-088 board CN501) means removing the lithium 3V power supply (ZM-030 board BT801, 802), data such as date, time, user-set menus will be lost. After completing adjustments, reset these data. If the cabinet (R) has been removed, the self-diagnosis data, data on history of use (total drum rotation time etc. ) will be lost. Before removing, note down the self-diagnosis data and the data on history use (data of page: 2, address: A2 to AA). (Refer to "SELF-DIAGNOSIS FUNCTION" for the self-diagnosis data, and to "6-4.Service Mode" for the data on the history use.) Note 4: Setting the "Forced Camera Power ON" Mode 1) Select page: 0, address: 01, and set data: 01. 2) Select page: D, address: 10, set data: 01, and press the PAUSE button of the adjustment remote commander. The above procedure will enable the camera power to be turned on with the control switch block (CF-4980) removed. After completing adjustments, be sure to exit the "Forced Camera Power ON Mode". Note 5: Exiting the "Forced Camera Power ON" Mode 1) Select page: 0, address: 01, and set data: 01. 2) Select page: D, address: 10, set data: 00, and press the PAUSE button of the adjustment remote commander. 3) Select page: 0, address: 01, and set data: 00.

95 cm

Front of the protection glass

Fig. 6-1-2.

6-5

DCR-VX2100/VX2100E

[CONNECTION OF EQUIPMENT]
Screw (M2 × 5), lock ace, p2 CPC cover CPC-13 jig (J-6082-443-A)

Adjustment remote commander (RM-95)

LANC jack

AC POWER ADAPTOR

AC IN

Fig. 6-1-3.

6-6

DCR-VX2100/VX2100E

1-1-3. Precaution 1. Setting the Switch Unless otherwise specified, set the switches as follows and perform adjustments without loading cassette. 1. POWER switch (CF-4980 block) .......................... CAMERA 2. DEMO MODE (Menu display) ....................................... OFF 3. DIGITAL ZOOM (Menu display) ................................... OFF 4. STEADY SHOT (Menu display) ..................................... OFF 5. DISPLAY (Menu display) ................................. V-OUT/LCD 6. DISPLAY (CK-140 board) ............................................... ON 7. AUTO LOCK (MK-016 board) ................................... AUTO 8. ND FILTER (Lens block) ................................................ OFF 9. FOCUS switch (FP-188 flexible) .......................... MANUAL 2. Order of Adjustments Basically carry out adjustments in the order given.

10. 11. 12. 13. 14. 15. 16. 17.

BACK LIGHT (FP-189 flexible) ..................................... OFF SPOT LIGHT (FP-189 flexible) ...................................... OFF PICTURE EFFECT (CK-140 board) ............................... OFF DIGITAL EFFECT (CK-140 board) ................................ OFF ZEBRA (CK-140 board) .................................................. OFF 16 : 9 WIDE (Menu display) ............................................ OFF AUTO SHUTTER (Menu display) .................................. OFF PROG.SCAN (Menu display) .......................................... OFF

Color bar chart (Color reproduction adjustment frame )
Yellow Cyan Green White Magenta Red

Electronic beam scanning frame

H

Blue

0 ± 0.1msec
Yellow Cyan Green White Magenta Red Blue

CRT picture frame

V A B A=B B A Enlargement

Fig. b (TV monitor picture)

Fig. a (Video output terminal output waveform)

Difference in level

B

A

Adjust the camera zoom and direction to obtain the output waveform shown in Fig. a and the TV monitor display shown in Fig. b.

Fig. 6-1-4
3. Subjects 1) Color bar chart (Standard picture frame). When performing adjustments using the color bar chart, adjust the picture frame as shown in Fig. 6-1-4. (Standard picture frame) 2) Clear chart (Standard picture frame) Remove the color bar chart from the pattern box and insert a clear chart in its place. (Do not perform zoom operations during this time.) 3) Flange back adjustment chart Make the chart shown in Fig. 6-1-5 using A0 size (1189 mm × 841 mm) black and white vellum paper.

White 841mm Black

1189mm

Fig. 6-1-5
Note: Use matte vellum paper bigger than A0, and make sure the edges of the black and white paper joined together are not rough.

6-7

DCR-VX2100/VX2100E

1-2.

INITIALIZATION OF B, C, D, E, F, 8 PAGE DATA
INITIALIZATION OF C, D, 8 PAGE DATA 2. Modification of C, D, 8 Page Data If the C, D, 8 page data has been initialized, change the data of the "Fixed data-2" address shown in the following tables by manual input. Modifying Method: 1) Before changing the data, select page: 0, address: 01, and set data: 01. 2) New data for changing are not shown in the tables because they are different in destination. When changing the data, copy the data built in the same model.
Note: If copy the data built in the different model, the camcorder may not operate.

1-2-1.

1. Initializing the C, D, 8 Page Data
Note1: If "Initializing the C, D, 8 Page Data" is performed, all data of the C page, D page and 8 page will be initialized. (It is impossible to initialize a single page.) Note2: If the C, D, 8 page data has been initialized, the following adjustments need to be performed again. 1) Modification of C, D, 8 page data 2) Serial No. input 3) Servo and RF system adjustments 4) Video system adjustments 5) Color viewfinder system adjustments 6) LCD system Adjustments

Adjustment Page Adjustment Address Adjustment Page Adjustment Address Adjustment Page Adjustment Address

C 10 to FF D 10 to FF 8 00 to FF

3)

4)

When changing the data, press the PAUSE button of the adjustment remote commander each time when setting new data to write the data in the non-volatile memory. Check that the data of adjustment addresses is the initial value. If not, change the data to the initial value.

Processing after Completing Modification of C, D, 8 Page data Order Page Address Data Procedure Procedure 1 2 2 2 00 01 29 29 Set the data Set the data, and press the PAUSE button.

Initializing Method: Order Page Address Data 1 2 3 4 5 0 3 3 3 01 81 80 80 01 0A

Set the data Check that the data is "00". Set the data, and press the PAUSE button. Check that the data changes to "1A" Perform "Modification of C, D, 8 Page Data".

Note: If the following symptoms occur after completing of the "Modification of C, D, 8 page data", check that the data of the "Fixed data-2" addresses of D page are same as those of the same model of the same destination. 1) The battery end mark on the LCD or viewfinder screen is flashing. 2) The power is shut off so that unit cannot operate.

3. C Page Table
Note: Fixed data-1: Initialized data. (Refer to "1. Initializing the C, D, 8 Page Data".) Fixed data-2: Modified data. (Refer to "2. Modification of C, D, 8 Page Data".)

Address 00 to 0F 10 11 12 13 14 to 15 16 17 18 19 1A 1B 1C 1D 1E 1F 20 21 22

Initial value EE 00 00 00 E0 E0 2A 2A 32 32 25 3E 3E DC 99

Remark Switching position adj.

Fixed data-1 Cap FG duty adj. Treel FG duty adj. AEQ adj. Fixed data-1 AEQ adj. Fixed data-1 AGC center level adj. PLL f0 adj. APC adj. LPF f0 adj.

6-8

DCR-VX2100/VX2100E

C Page Address 23 to 24 25 26 27 28 29 2A to 2B 2C 2D to 41 42 43 to 55 56 57 to 81 82 83 to 85 86 87 88 89 8A to 9A 9B 9C 9D 9E 9F A0 A1 to A2 A3 A4 A5 A6 A7 A8 A9 to AA AB AC AD AE AF B0 B1 B2 B3 B4 B5 B6 B7 B8 B9 BA to BF C0 C1 C2 C3 C4 C5 Initial value 88 E3 A1 04 20 03 Remark Fixed data-1 S VIDEO out Y level adj. S VIDEO out Cr level adj. S VIDEO out Cb level adj. Chroma BPF f0 adj. PLL f0 fine adj. Fixed data-1 APC adj. Fixed data-1 Fixed data-2 Fixed data-1 Fixed data-2 Fixed data-1 Fixed data-2 Fixed data-1 Fixed data-2 Address C6 C7 C8 C9 CA to D5 D6 D7 D8 D9 DA DB DC DD DE DF E0 E1 to E5 E6 E7 E8 E9 EA EB EC ED EE EF F0 to F3 F4 F5 F6 F7 F8 F9 FA FB FC FD FE FF Initial value Remark Fixed data-2 Fixed data-1 Fixed data-2 Fixed data-1 Fixed data-2

Fixed data-1 Fixed data-2 Fixed data-1 Fixed data-2

Fixed data-1 Fixed data-2

08 00 46 01 01 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00

Fixed data-1 Fixed data-2 Fixed data-1 Serial No. input

Fixed data-1 Emergency memory address

Fixed data-1 Fixed data-2

Fixed data-1 Fixed data-2

Table. 6-1-2.

Fixed data-1 Fixed data-2 Fixed data-1 Fixed data-2

6-9

DCR-VX2100/VX2100E

4. D Page Table
Note: Fixed data-1: Initialized data. (Refer to "1. Initializing the C, D, 8 Page Data".) Fixed data-2: Modified data. (Refer to "2. Modification of C, D, 8 Page Data".)

5. 8 Page Table
Note: Fixed data-1: Initialized data. (Refer to "1. Initializing the C, D, 8 Page Data".) Fixed data-2: Modified data. (Refer to "2. Modification of C, D, 8 Page Data".)

Address 00 to 0F 10 11 to 12 13 14 15 to 2C 2D 2E 2F to 3F 40 41 to 47 48 49 4A 4B 4C 4D to 90 91 92 93 94 95 96 97 98 99 9A to A1 A2 A3 A4 A5 A6 A7 A8 A9 AA AB AC AD AE AF B0 to B9 BA BB to C5 C6 C7 to D0 D1 D2 to D6 D7 D8 to FF

Initial value 00

Remark Test mode Fixed data-1 Fixed data-2 Fixed data-1 Fixed data-2 Fixed data-1 Fixed data-2 Fixed data-1 Battery end adj.

Address 00 to 0A 0B 0C to 8F 90 91 to 98 99 9A to FF Fixed data-1 Fixed data-2 Fixed data-1 Fixed data-2 Fixed data-1 Fixed data-2 Fixed data-1

Remark

Table. 6-1-4.

91 97 A8 BD C8

60 60 AC 90 80 30 71 71 9F AA 0A AE 85 75 40 30

Fixed data-1 Fixed data-2 VCO adj. (EVF) Fixed data-1 Bright adj. (EVF) Fixed data-1 White balance adj. (EVF) Contrast adj. (EVF) Fixed data-1 VCO adj. (LCD) V-COM adj. (LCD) Bright adj.(LCD) Black limit adj.(LCD) PSIG GRAY adj.(LCD) White balance adj. (LCD) Contrast adj. (LCD) Center level adj.(LCD) Fixed data-2

Fixed data-1 Fixed data-2 Fixed data-1 Fixed data-2 Fixed data-1 Fixed data-2 Fixed data-1 Fixed data-2 Fixed data-1

Table. 6-1-3.

6-10

DCR-VX2100/VX2100E

1-2-2.

INITIALIZATION OF B PAGE DATA

Note: When reading the B page data, insert a "Memory Stick" into the "Memory Stick" slot.

Switch setting: POWER ................................................................. MEMORY 1. Initializing the B Page Data
Note: If the B page data has been initialized, the following adjustments need to be performed again. 1) Modification of B page data

2. Modification of B Page Data If the B page data has been initialized, change the data of the "Fixed data-2" address shown in the following tables by manual input. Preparations:

Adjustment Page Adjustment Address

B 00 to FF

Initializing Method Order Page Address Data 1 2 3 4 5 6 7 0 5 5 5 5 5 01 01 00 01 00 02 01 F3 01

Order Page Address Data Procedure 1 2 8F 00 Set the data, and press PAUSE button. Procedure 2 3 2 2 8F 8F 03 00 Set the data, and press PAUSE button. Set the data, and press PAUSE button.

Set the data. Set the data, and press PAUSE button. Set the data, and press PAUSE button. Wait for three seconds. Check that the data is "00". Check that the data is "00". Perform "Modification of B Page Data".

Modifying Method: 1) Before changing the data, select page: 0, address: 01, and set data: 01. 2) New data for changing are not shown in the tables because they are different in destination. When changing the data, copy the data built in the same model.
Note: If copy the data built in the different model, the camcorder may not operate.

3)

When changing the data, press the PAUSE button of the adjustment remote commander each time when setting new data to write the data in the non-volatile memory.

Processing after Completing Modification of B Page data: Order Page Address Data Procedure 1 2 00 29 Set the data. 2 2 01 29 Set the data, and press PAUSE button.

3. B Page Table
Note: Fixed data-1: Initialized data. (Refer to "1. or 3. Initializing the B Page Data".) Fixed data-2: Modified data. (Refer to "2. or 4. Modification of B Page Data".)

Address 00 to 3A 3B 3C to 3D 3E 3F to 5F 60 61 to FF Fixed data-1 Fixed data-2 Fixed data-1 Fixed data-2 Fixed data-1 Fixed data-2 Fixed data-1

Remark

Table. 6-1-5.

6-11

DCR-VX2100/VX2100E

1-2-3.

INITIALIZATION OF E, F PAGE DATA

3. F Page Table
Note1: Fixed data-1: Initialized data. (Refer to "1. Initializing the E, F Page Data".) Fixed data-2: Modified data. (Refer to "2. Modification of E, F Page Data".) Note2: NTSC model : DCR-VX2100 PAL model : DCR-VX2100E

1. Initializing the E, F Page Data
Note1: If "Initializing the E, F Page Data" is performed, all data of the E page and F page will be initialized. (It is impossible to initialize a single page.) Note2: If the E, F page data has been initialized, following adjustments need to be performed again. 1) Modification of E, F page data 2) Camera system adjustments

Adjustment Page Adjustment Address Adjustment Page Adjustment Address

F 10 to FF E 00 to FF

Switch setting: POWER .................................................................. CAMERA Initializing Method: Order Page Address Data 1 2 0 6 01 01 01

Procedure Set the data. Set the following data, and press PAUSE button. 2D: DCR-VX2100 (NTSC) 2F : DCR-VX2100E (PAL) Set the data, and press PAUSE button. Check that the data changes to "01". Perform "Modification of E, F Page Data".

3 4 5

6 6

03 02

01

2. Modification of E, F Page Data If the E, F page data has been initialized, change the data of the "Fixed data-2" address shown in the following table by manual input. Modifying Method: 1) Before changing the data, select page: 0, address: 01, and set data: 01. 2) New data for changing are not shown in the tables because they are different in destination. When changing the data, copy the data built in the same model.
Note: If copy the data built in the different model, the camcorder may not operate.

3)

4)

When changing the data, press the PAUSE button of the adjustment remote commander each time when setting new data to write the data in the non-volatile memory. Check that the data of adjustment addresses is the initial value. If not, change the data to the initial value.

Processing after Completing Modification of E, F Page data 1) Select page: 0, address: 01, and set data: 00. 2) Turn off the power and turn on again.

Address Initial value NTSC PAL 00 to 0F 10 to 14 15 16 to 1B 1C 80 80 1D 1E 60 60 1F 40 60 20 00 00 21 15 15 22 00 00 23 2E 2E 24 AE AE 25 2B 2B 26 44 44 27 43 43 28 B2 B2 29 16 16 2A 00 00 2B 00 00 2C 8B 8B 2D to 33 34 88 90 35 6C 8F 36 D6 D6 37 E6 E6 38 46 46 39 45 00 3A 3F 19 3B 3F 00 3C 16 27 3D A8 A8 3E 38 38 3F 76 76 40 41 50 50 42 50 50 43 44 EB EB 45 D5 D5 46 20 20 47 20 20 48 to 49 4A 00 00 4B 00 00 4C to 52 53 54 55

Remark

Fixed data-1 Fixed data-2 Fixed data-1 27MHz origin osc. adj. Fixed data-1 HALL adj. AWB standard data input

Flange back adj.

MAX GAIN adj. Fixed data-1 Auto white balance adj. Flange back adj.

LV standard data input Fixed data-1 Steady shot adj. Fixed data-1 Color reproduction adj. (ND filter OFF)

Fixed data-1 WB ND filter 1 compensation Fixed data-1 Fixed data-2

6-12

DCR-VX2100/VX2100E
F Page Address Initial value NTSC PAL 56 to 5C 5D 80 80 5E to 5F 60 61 to 6A 6B 6C 6D 6E 6F 70 89 89 71 to 7B 7C 7D 7E to 80 81 82 83 84 to 8D 8E 8F to 9E 9F A0 to A5 A6 A7 A8 to AA AB AC to B1 B2 B3 to B9 BA BB to C5 C6 C7 C8 C9 to CA CB CC CD CE CF D0 D1 D2 D3 D4 D5 D6 to DF E0 E1 to EC ED EE to F4 F5 F6 F7 Remark Fixed data-1 Zoom key center adj. Fixed data-1 Fixed data-2 Fixed data-1 Fixed data-2 Address Initial value NTSC PAL F8 F9 FA to FC FD FE to FF Remark Fixed data-1 Fixed data-2 Fixed data-1 Fixed data-2 Fixed data-1

Table. 6-1-6.

Fixed data-1 HALL adj. Fixed data-1 Fixed data-2 Fixed data-1 Fixed data-2 Fixed data-1 Fixed data-2 Fixed data-1 Fixed data-2 Fixed data-1 Fixed data-2 Fixed data-1 Fixed data-2 Fixed data-1 Fixed data-2 Fixed data-1 Fixed data-2 Fixed data-1 Fixed data-2 Fixed data-1 Fixed data-2 Fixed data-1 Fixed data-2 Fixed data-1 Fixed data-2

Fixed data-1 Fixed data-2 Fixed data-1 Fixed data-2 Fixed data-1 Fixed data-2

6-13

DCR-VX2100/VX2100E

4. E Page Table
Note1: Fixed data-1: Initialized data. (Refer to "1. Initializing the E, F Page Data".) Fixed data-2: Modified data. (Refer to "2. Modification of E, F Page Data".) Note2: Refer to "2. Modification of E, F Page Data" for the camera microprocessor version. Note3: NTSC model : DCR-VX2100 PAL model : DCR-VX2100E

Address Initial value NTSC PAL 00 to 03 04 05 06 07 08 to 10 11 12 to 13 14 15 to 29 2A 10 10 2B 10 10 2C 2D 80 80 2E 80 80 2F 80 80 30 to 47 48 49 4A to 4C 4D 4E to 51 52 53 54 55 56 57 58 59 5A 5B 5C 5D 5E 5F 60 to 61 62 EB EB 63 D5 D5 64 20 20 65 20 20 66 to 74 75 76 to 89 8A 8B

Remark Fixed data-1 Fixed data-2

Fixed data-1 Fixed data-2 Fixed data-1 Fixed data-2 Fixed data-1 Pre-white balance data input Fixed data-1 Offset adj.

Fixed data-1 Fixed data-2 Fixed data-1 Fixed data-2 Fixed data-1 Fixed data-2 Fixed data-1 Fixed data-2 Fixed data-1 Fixed data-2 Fixed data-1 Fixed data-2 Fixed data-1 Fixed data-2 Fixed data-1 Fixed data-2

Fixed data-1 Color reproduction adj. (ND filter 1)

Fixed data-1 Fixed data-2 Fixed data-1 Fixed data-2 Fixed data-1

Address Initial value NTSC PAL 8C 8D 8E 00 00 8F 00 00 90 EB EB 91 D5 D5 92 20 20 93 20 20 94 95 96 97 to 9D 9E 9F to A0 A1 A2 A3 A4 A5 A6 to A7 A8 A9 to AB AC AD AE to B0 B1 B2 B3 B4 to B9 BA BB to C3 C4 C5 to CB CC CD CE CF to D9 DA DB DC to EB EC ED to F2 F3 F4 F5 F6 F7 F8 F9 FA to FD FE FF

Remark Fixed data-2 WB ND filter 2 compensation Color reproduction adj. (ND filter 2)

Fixed data-2 Fixed data-1 Fixed data-2 Fixed data-1 Fixed data-2 Fixed data-1 Fixed data-2 Fixed data-1 Fixed data-2 Fixed data-1 Fixed data-2 Fixed data-1 Fixed data-2 Fixed data-1 Fixed data-2 Fixed data-1 Fixed data-2 Fixed data-1 Fixed data-2 Fixed data-1 Fixed data-2 Fixed data-1 Fixed data-2

Fixed data-1 Fixed data-2 Fixed data-1 Fixed data-2 Fixed data-1 Fixed data-2 Fixed data-1 Fixed data-2 Fixed data-1 Fixed data-2

Fixed data-1 Fixed data-2

Table. 6-1-6.

6-14

DCR-VX2100/VX2100E

1-3.

CAMERA SYSTEM ADJUSTMENTS

Before perform the camera system adjustments, check that the specified values of "VIDEO SYSTEM ADJUSTMENT" are satisfied. 1. 27MHz Origin Oscillation Adjustment (VC-358 board) Set the frequency of the clock for synchronization. If deviated, the synchronization will be disrupted and the color will become inconsistent. Subject Not required Measurement Point Measuring Instrument Adjustment Page Adjustment Address Specified Value Pin rj of IC771 or pin qf of IC706 Frequency counter F 1C f=13500000 ± 68Hz 2. Zoom Key Center Adjustment Set the A/D value center of the microprocessor to the center voltage of the zoom key. If deviated, the zoom lens operates of itself ,even if the zoom key is the center position. Subject Measurement Point Measuring Instrument Adjustment Page Adjustment Address Not required Display data of page: 6, address: 50 Adjustment remote commander F 5D

Note: Don't touch the zoom switch during adjustment.

Adjusting method: Order Page Address Data 1 2 0 F 01 1C 01

Procedure Set the data. Change the data and set the frequency (f) to the specified value. Press PAUSE button. Set the data.

Adjusting method: Order Page Address Data 1 2 3 4 0 6 F 0 01 50 5D 01 01

Procedure Set the data. Read the data, and this data is named D50. Set the data, and press PAUSE button. Set the data.

3 4

F 0

1C 01

D50 00

00

VC-358 board
51 50 26 25 24 13 12 1 37 48 1

IC771
75 76 100

IC706

Fig. 6-1-6.

6-15

DCR-VX2100/VX2100E

3. HALL Adjustment For detecting the position of the lens iris, adjust AMP gain and offset. Subject Not required Measurement Point Measuring Instrument Adjustment Page Adjustment Address Specified Value 1 Specified Value 2 Display data of page 1 (Note1) Adjustment remote commander F 1E, 1F, 70 88 to 8C 15 to 19

4. Offset Adjustment Adjust so that the AGC OUT potential lies within the specified value of the digital clamp. Subject Not required Measurement Point Measuring Instrument Adjustment Page Adjustment Address Specified Value E 2D, 2E, 2F 70 to 90 DDS display data of LCD or TV monitor (Note1)

Note1: Displayed data of page 1 of the adjustment remote commander. 1 : XX : XX IRIS display data Note2: Check that the data of page: 6, address: 02 is "00". If not, to page: 6, address: 01, set data: 00, and press the PAUSE button.

Note 1: DDS display data of LCD or TV monitor. CA 00 0000 CA 00 00XX Object data

Adjusting method: Order Page Address Data Procedure 1 0 01 01 Set the data. 2 3 4 5 6 6 6 6 6 6 94 95 01 02 01 00 8A 17 6D Set the data. Set the data. Set the data, and press PAUSE button. Check that the data changes to "01". (Note3) Set the data, and press PAUSE button.

Adjusting method: Order Page Address Data 1 2 3 4 5 6 0 D 6 E 6 E 01 11 01 0C 04 2D 01 02 05 02 1F

Procedure Set the data. Set the data, and press PAUSE button. Set the data, and press PAUSE button. Set the data, and press PAUSE button. Set the data. Change the data and adjust the DDS display data (Note 1) to "80". (Rch offset adjustment) Press PAUSE button. Set the data. Change the data and adjust the DDS display data (Note 1) to "80". (Gch offset adjustment) Press PAUSE button. Set the data. Change the data and adjust the DDS display data (Note 1) to "80". (Bch offset adjustment) Press PAUSE button.

Note3: The adjustment data will be automatically input to page: F, address: 1E, 1F, 70.

7 8 9

E 6 E

2D 04 2E 20

Checking method: Order Page Address Data Procedure 1 6 04 03 Set the data. 2 3 6 1 01 01 Set the data, and press PAUSE button. Check that the IRIS display data (Note1) satisfies the specified value 1. Set the data, and press PAUSE button. Check that the IRIS display data (Note1) satisfies the specified value.2.

10 11 12

E 6 E

2E 04 2F

21

4 5

6 1

01

03

13

E

2F

Processing after Completing Adjustments Order Page Address Data Procedure 1 D 11 00 Set the data, and press PAUSE button. 2 3 4 5 6 E 0 6 6 0C 01 01 04 00 00 00 00 Set the data, and press PAUSE button. Set the data. Set the data, and press PAUSE button. Set the data. Turn off the power and turn on again.

Processing after Completing Adjustments: Order Page Address Data Procedure 1 6 01 00 Set the data, and press PAUSE button. 2 3 4 5 6 6 6 0 04 94 95 01 00 00 00 00 Set the data. Set the data. Set the data. Set the data.

6-16

DCR-VX2100/VX2100E

5. Flange Back Adjustment (Using Minipattern Box) The inner focus lens flange back adjustment is carried out automatically. In whichever case, the focus will be deviated during auto focusing/manual focusing. Subject Siemens star chart with ND filter for the minipattern box (Note2) Measurement Point Measuring Instrument Adjustment Page Adjustment Address Check operation on TV monitor F 24 to 2B, 36 to 3D, 5D

Note1: Dark Siemens star chart. Note2: Check that the data of page: 6, address: 02 is "00". If not, to page: 6, address: 01, set data: 00, and press the PAUSE button.

Switch setting: ND FILTER ...................................................................... OFF (The data of page: 6, address: 9D is "00".) Preparations: 1) The minipattern box is installed as shown in the following figure.
Note: The attachment lenses are not used.

Adjusting method: Order Page Address Data 1 2 3 4 5 0 6 6 6 F 01 01 01 02 2A 01 13 27

Procedure Set the data. Set the data, and press PAUSE button. (Note3) Set the data, and press PAUSE button. Check that the data changes to "01". (Note4) Check that the data is "00" to "07".

2)

3) 4) 5)

Install the minipattern box so that the distance between it and the front of the protection glass of the camcorder is less than 3cm. (Remove the lens hood.) Make the height of the minipattern box and the camcorder equal. Check that the output voltage of the regulated power supply is the specified voltage. Check that at both the zoom lens TELE end and WIDE end, the center of the Siemens star chart and center of the exposure screen coincide.

Specified voltage: The specified voltage varies according to the minipattern box, so adjust the power supply output voltage to the specified voltage written on the sheet which is supplied with the minipattern box.
Below 3 cm Minipattern box Camcorder Camera table Regulated power supply Output voltage : Specified voltage ±0.01Vdc Output current : more than 3.5A

Note3: Don't touch the zoom switch. If you touch the zoom switch, the zoom center adjustment data will be rewritten in the value which isn't correct. Note4: The adjustment data will be automatically input to page: F, address:: 24 to 2B, 36 to 3D, 5D.

Processing after Completing Adjustments: Order Page Address Data Procedure 1 6 01 00 Set the data, and press PAUSE button. 2 3 4 5 6 0 02 01 00 00 Set the data. Set the data. Turn off the power and turn on again. Perform "Flange Back Check".

Red (+) Black (­) Yellow (SENS +) White (SENS ­) Black (GND) Need not connected

Fig. 6-1-7.

6-17

DCR-VX2100/VX2100E

6. Flange Back Adjustment (Using Flange Back Adjustment Chart and Subject More Than 500m Away) The inner focus lens flange back adjustment is carried out automatically. In whichever case, the focus will be deviated during auto focusing/manual focusing. 6-1. Flange Back Adjustment (1) Subject Flange back adjustment chart (2.0 m from the front of the protection glass) (Luminance: 230 ± 30 lux) Measurement Point Measuring Instrument Adjustment Page Adjustment Address Check operation on TV monitor F 24 to 2B, 36 to 3D, 5D 6-2. Flange Back Adjustment (2) Perform this adjustment after performing "Flange Back Adjustment (1)". Subject Subject more than 500m away (Subjects with clear contrast such as buildings, etc.) Measurement Point Measuring Instrument Adjustment Page Adjustment Address Check operation on TV monitor F 24 to 2B, 36 to 3D, 5D

Note1: Check that the data of page: 6, address: 02 is "00". If not, to page: 6, address: 01, set data: 00, and press the PAUSE button.

Note1: Check that the data of page: 6, address: 02 is "00". If not, to page: 6, address: 01, set data: 00, and press the PAUSE button.

Switch setting: ND FILTER ...................................................................... OFF (The data of page: 6, address: 9D is "00".) Adjusting method: Order Page Address Data Procedure 1 0 01 01 Set the data. 2 3 4 5 6 6 6 F 01 01 02 2A 13 15 Set the data, and press PAUSE button. (Note2) Set the data, and press PAUSE button. Check that the data changes to "01". (Note3) Check that the data is "00" to "07".

Preparations: 1) Set the zoom lens to the TELE end and expose a subject that is more than 500 m away (subject with clear contrast such as building, etc.). (Nearby subjects less than 500 m away should not be in the screen.) Adjusting method: Order Page Address Data Procedure 1 0 01 01 Set the data. 2 6 01 13 Set the data, and press PAUSE button. (Note2) Place a ND filter on the lens so that the optimum image is obtain. Set the data, and press PAUSE button. Check that the data changes to "01". (Note3)

3 4

6 6

01 02

29

Note2: Don't touch the zoom switch. If you touch the zoom switch, the zoom center adjustment data will be rewritten in the value which isn't correct. Note3: The adjustment data will be automatically input to page: F, address:: 24 to 2B, 36 to 3D, 5D.

Processing after Completing Adjustments: Order Page Address Data Procedure 1 2 3 6 01 00 Set the data, and press PAUSE button. Turn off the power and turn on again. Perform "Flange Back Adjustment (2)"

Note2: Don't touch the zoom switch. If you touch the zoom switch, the zoom center adjustment data will be rewritten in the value which isn't correct. Note3: The adjustment data will be automatically input to page: F, address:: 24 to 2B, 36 to 3D, 5D.

Processing after Completing Adjustments: Order Page Address Data Procedure 1 2 3 6 01 00 Set the data, and press PAUSE button. Turn off the power and turn on again. Perform "Flange Back Check".

6-18

DCR-VX2100/VX2100E

7. Flange Back Check Subject Siemens star (2.0m from the front of the protection glass) (Luminance : approx. 300 ± 50 lux) Measurement Point Measuring Instrument Specified Value Check operation on TV monitor Focused at the TELE end and WIDE end.

Checking method: 1) Place the Siemens star 2.0m from the front of the protection glass. 2) To open the IRIS, decrease the luminous intensity to the Siemens star up to a point before noise appear on the image. 3) Shoot the Siemens star with the zoom TELE end. 4) Turn on the auto focus. 5) Check that the lens is focused. 6) Turn off the auto focus. 7) While observe the TV monitor, move the zoom to the WIDE end and check that the lens is focused. 8. Picture Frame Setting Subject Color bar chart (Color bar standard picture frame) (95cm from the front of the protection glass) Measurement Point Measuring Instrument Specified Value Video output terminal Oscilloscope and TV monitor A=B, C=D, t=0 ± 0.1msec

Check on the oscilloscope 1. Horizontal period
A=B B A C=D C D

Switch setting: 1) ND FILTER ...................................................................... OFF (The data of page: 6, address: 9D is "00".) 2) STEADY SHOT (Menu setting) ...................................... OFF Setting method: Order Page Address Data 1 2 3 4 5 6 7 8 6 6 6 6 6 6 2C 90 91 92 93 01 01 28 02 6E 49 79

Procedure Set the data. Set the data. Set the data. Set the data. Set the data. Set the data, and press PAUSE button. Adjust the camera direction, and set to the specified position. Mark the position of the picture frame on the monitor display, and adjust the picture frame to this position in following adjustments using "Color bar standard frame".

Fig. 6-1-8. 2. Vertical period
t=0 ± 0.1msec

V

Fig. 6-1-9. Color on the TV monitor

9

6

01

00

Set the data, and press PAUSE button.

Color bar chart picture frame

TV monitor picture frame

Fig. 6-1-10.

6-19

DCR-VX2100/VX2100E

9. Pre White Balance Data Input At 3200k, input the pre white balance standard data. Subject Clear chart (Color bar standard picture frame) Adjustment Page Adjustment Address E 2A, 2B

10. Auto White Balance Standard Data Input At 3200K, input the white balance standard data. Subject Clear chart (Color bar standard picture frame) Adjustment Page Adjustment Address F 20 to 23

Note1: After the power is turned on, this adjustment can be done only once. Note2: NTSC: DCR-VX2100 PAL: DCR-VX2100E

Note1: After the power is turned on, this adjustment can be done only once. Note2: Check that the data of page: 6, address: 02 is "00". If not, to page: 6, address: 01, set data: 00, and press the PAUSE button.

Switch setting: ND FILTER ...................................................................... OFF (The data of page: 6, address: 9D is "00".) Adjusting method: Order Page Address Data Procedure 1 0 01 01 Set the data. 2 3 4 5 6 7 6 F F F F F 02 20 21 22 23 16 00 00 15 00 2E Set the data. Set the data, and press PAUSE button. Set the data, and press PAUSE button. Set the data, and press PAUSE button. Set the data, and press PAUSE button. Set the following data, and press PAUSE button. 03 (NTSC), 83 (PAL) Set the data, and press PAUSE button. Set the data, and press PAUSE button. (Note3) Check that the data changes to "01".

Switch setting: ND FILTER ...................................................................... OFF (The data of page: 6, address: 9D is "00".) Adjusting method: Order Page Address Data Procedure 1 0 01 01 Set the data. 2 3 4 6 6 6 01 01 02 11 0B Set the data, and press PAUSE button. Set the data, and press PAUSE button. (Note3) Check that the data changes to "01".

Note3: The adjustment data will be automatically input to page: F, address: 20 to 23.

8 9 10

6 6 6

01 01 02

7F 7D

Processing after Completing Adjustments Order Page Address Data Procedure 1 6 01 00 Set the data, and press PAUSE button. 2 3 6 0 02 01 00 00 Set the data. Set the data.

Note3: The adjustment data will be automatically input to page: E, address: 2A and 2B.

Processing after Completing Adjustments Order Page Address Data Procedure 1 6 01 00 Set the data, and press PAUSE button. 2 3 6 F 02 16 00 Set the data. Set the following data, and press PAUSE button. 33 (NTSC), B3 (PAL) Set the data. Perform "Auto White Balance Standard Data Input".

4 5

0

01

00

6-20

DCR-VX2100/VX2100E

11. MAX GAIN Adjustment Setting the minimum illumination. If it is not consistent, the image level required for taking subjects in low illuminance will not be produced (dark). Subject Clear chart (Color bar standard picture frame) Adjustment Page Adjustment Address F 2C

12. LV Standard Data Input Adjust the normal coefficient of the light value. Subject Clear chart (Color bar standard picture frame) Measurement Point Measuring Instrument Adjustment Page Adjustment Address Specified Value Display data of page 1 (Note2) Adjustment remote commander F 3E, 3F 0FE0 to 1020

Switch setting: ND FILTER ...................................................................... OFF (The data of page: 6, address: 9D is "00".) Adjusting method: Order Page Address Data Procedure 1 0 01 01 Set the data. 2 3 4 5 6 6 6 6 6 6 02 96 97 01 02 00 00 5C 6F Set the data. Set the data. Set the data. Set the data, and press PAUSE button. (Note) Check that the data changes to "01".

Note1: Check that the data of page: 6, address: 02 is "00". If not, turn the power of the unit OFF/ON. Note2: Displayed data of page 1 of the adjustment remote commander. 1 : XX : XX LV data

Switch setting: ND FILTER ...................................................................... OFF (The data of page: 6, address: 9D is "00".) Adjusting method: Order Page Address Data 1 2 3 4 5 6 7 0 F 01 15 01 40

Procedure Set the data. Set the data, and press PAUSE button. Wait for 5 seconds. Set the data, and press PAUSE button. (Note3) Check that the data changes to "01". Set the data. Check that the LV data (Note2) satisfies the specified value. If not, repeat from step 2.

Note: The adjustment data will be automatically input to page: F, address: 2C.

6 6 6 1

01 02 04

0D

Processing after Completing Adjustments Order Page Address Data Procedure 1 6 96 00 Set the data. 2 3 4 5 6 6 6 0 97 01 02 01 00 00 00 00 Set the data. Set the data, and press PAUSE button. Set the data. Set the data.

1E

Note3: The adjustment data will be automatically input to page: F, address: 3E and 3F.

Processing after Completing Adjustments Order Page Address Data Procedure 1 6 01 00 Set the data, and press PAUSE button. 2 3 4 5 6 6 F 0 02 04 15 01 00 00 44 00 Set the data. Set the data. Set the data, and press PAUSE button. Set the data.

6-21

DCR-VX2100/VX2100E

13. White Balance ND Filter 1 Compensation Compensate the white balance deviation when ND FILTER switch is "1". Subject Clear chart (Color bar standard picture frame) Adjustment Page Adjustment Address F 4A, 4B

14. White Balance ND Filter 2 Compensation Compensate the white balance deviation when ND FILTER switch is "2". Subject Clear chart (Color bar standard picture frame) Adjustment Page Adjustment Address E 8E, 8F

Note1: After the power is turned on, this adjustment can be done only once. Note2: Check that the data of page: 6, address: 02 is "00". If not, to page: 6, address: 01, set data: 00, and press the PAUSE button.

Note1: After the power is turned on, this adjustment can be done only once. Note2: Check that the data of page: 6, address: 02 is "00". If not, to page: 6, address: 01, set data: 00, and press the PAUSE button.

Switch setting: ND FILTER ........................................................................... 1 (The data of page: 6, address: 9D is "01".) Adjusting method: Order Page Address Data Procedure 1 0 01 01 Set the data. 2 3 4 6 6 6 01 01 02 11 09 Set the data, and press PAUSE button. Set the data, and press PAUSE button. (Note3) Check that the data changes to "01".

Switch setting: ND FILTER ........................................................................... 2 (The data of page: 6, address: 9D is "02".) Adjusting method: Order Page Address Data Procedure 1 0 01 01 Set the data. 2 3 4 6 6 6 01 01 02 CF CD Set the data, and press PAUSE button. Set the data, and press PAUSE button. (Note3) Check that the data changes to "01".

Note3: The adjustment data will be automatically input to page: F, address: 4A and 4B.

Note3: The adjustment data will be automatically input to page: E, address: 8E and 8F.

Processing after Completing Adjustments Order Page Address Data Procedure 1 6 01 00 Set the data, and press PAUSE button. 2 3 6 0 02 01 00 00 Set the data. Set the data.

Processing after Completing Adjustments Order Page Address Data Procedure 1 6 01 00 Set the data, and press PAUSE button. 2 3 4 6 0 02 01 00 00 Set the data. Set the data. Set ND FILTER switch to "OFF".

6-22

DCR-VX2100/VX2100E

15. Auto White Balance Adjustment Adjust to the proper auto white balance output data. If it is not correct, auto white balance and color reproducibility will be poor. Subject Clear chart (Color bar standard picture frame) Filter Adjustment Page Adjustment Address Filter C14 for color temperature correction F 34, 35

16. Color Reproduction Adjustment (ND Filter OFF) When the ND FILTER switch is "OFF", adjust the color difference matrix coefficient so that proper color reproduction is produced. Subject Color bar chart (Color bar standard picture frame) Measurement Point Measuring Instrument Adjustment Page Adjustment Address Specified Value Video output terminal Vectorscope F 44, 45, 46, 47 All color luminance points should settle within each color reproduction frame. (Fig. 6-1-11)

Note1: After the power is turned on, this adjustment can be done only once. Note2: Check that the data of page: 6, address: 02 is "00". If not, to page: 6, address: 01, set data: 00, and press the PAUSE button.

Switch setting: ND FILTER ...................................................................... OFF (The data of page: 6, address: 9D is "00".) Adjusting method: Order Page Address Data 1

Note1: After the power is turned on, this adjustment can be done only once. Note2: Check that the data of page: 6, address: 02 is "00". If not, to page: 6, address: 01, set data: 00, and press the PAUSE button.

Switch setting: ND FILTER ...................................................................... OFF (The data of page: 6, address: 9D is "00".) Adjusting method: Order Page Address Data 1

Procedure Place the C14 filter for color temperature correction on the lens. Set the data. Set the data. Set the data, and press PAUSE button. Set the data, and press PAUSE button. (Note3) Check that the data changes to "01".

Procedure Check that the picture frame is set to the specified position. (Refer to "8. Picture Frame Setting".) Set the data. Set the data, and press PAUSE button. Set the data, and press PAUSE button. Set the data, and press PAUSE button. Set the data, and press PAUSE button. Set the data, and press PAUSE button. Set the data, and press PAUSE button. Set the data, and press PAUSE button. (Note3) Check that the data changes to "01". Adjust the GAIN and PHASE of the vectorscope, and adjust the burst luminance point to the burst position of the color reproduction frame. (Fig. 6-1-11) Check that all color luminance points settle within each color reproduction frame. (Fig. 6-1-11)

2 3 4 5 6

0 6 6 6 6

01 02 01 01 02

01 00 83 81

2 3 4 5 6 7 8 9 10 11

0 F F F F F 6 6 6

01 5E 44 45 46 47 01 01 02

01 2D 00 00 20 20 AB A9

Note3: The adjustment data will be automatically input to page: F, address: 34 and 35.

Processing after Completing Adjustments Order Page Address Data Procedure 1 2 3 6 6 0 01 02 01 00 00 00 Set the data, and press PAUSE button. Set the data. Set the data.

PAL Burst position (VX2100E)

12

Note3: The adjustment data will be automatically input to page: F, address: 44 to 47.

Processing after Completing Adjustments Order Page Address Data Procedure 1 2 3 6 6 F 0 01 02 5E 01 00 00 1D 00 Set the data, and press PAUSE button. Set the data. Set the data, and press PAUSE button. Set the data.

NTSC Burst position (VX2100)

Fig. 6-1-11.
3

6-23

DCR-VX2100/VX2100E

17. Color Reproduction Adjustment (ND Filter 1) When the ND FILTER switch is "1", adjust the color difference matrix coefficient so that proper color reproduction is produced. Subject Color bar chart (Color bar standard picture frame) Measurement Point Measuring Instrument Adjustment Page Adjustment Address Specified Value Video output terminal Vectorscope E 62, 63, 64, 65 All color luminance points should settle within each color reproduction frame. (Fig. 6-1-11)

18. Color Reproduction Adjustment (ND Filter 2) When the ND FILTER switch is "2", adjust the color difference matrix coefficient so that proper color reproduction is produced. Subject Color bar chart (Color bar standard picture frame) Measurement Point Measuring Instrument Adjustment Page Adjustment Address Specified Value Video output terminal Vectorscope E 90, 91, 92, 93 All color luminance points should settle within each color reproduction frame. (Fig. 6-1-11)

Note1: After the power is turned on, this adjustment can be done only once. Note2: Check that the data of page: 6, address: 02 is "00". If not, to page: 6, address: 01, set data: 00, and press the PAUSE button.

Note1: After the power is turned on, this adjustment can be done only once. Note2: Check that the data of page: 6, address: 02 is "00". If not, to page: 6, address: 01, set data: 00, and press the PAUSE button.

Switch setting: 1) ND FILTER ........................................................................... 1 (The data of page: 6, address: 9D is "01".) Adjusting method: Order Page Address Data 1

Switch setting: 1) ND FILTER ........................................................................... 2 (The data of page: 6, address: 9D is "02".) Adjusting method: Order Page Address Data 1

Procedure Check that the picture frame is set to the specified position. (Refer to "8. Picture Frame Setting".) Set the data. Set the data, and press PAUSE button. Set the data, and press PAUSE button. Set the data, and press PAUSE button. Set the data, and press PAUSE button. Set the data, and press PAUSE button. Set the data, and press PAUSE button. Set the data, and press PAUSE button. (Note3) Check that the data changes to "01". Adjust the GAIN and PHASE of the vectorscope, and adjust the burst luminance point to the burst position of the color reproduction frame. (Fig. 6-1-11) Check that all color luminance points settle within each color reproduction frame. (Fig. 6-1-11)

Procedure Check that the picture frame is set to the specified position. (Refer to "8. Picture Frame Setting".) Set the data. Set the data, and press PAUSE button. Set the data, and press PAUSE button. Set the data, and press PAUSE button. Set the data, and press PAUSE button. Set the data, and press PAUSE button. Set the data, and press PAUSE button. Set the data, and press PAUSE button. (Note3) Check that the data changes to "01". Adjust the GAIN and PHASE of the vectorscope, and adjust the burst luminance point to the burst position of the color reproduction frame. (Fig. 6-1-11) Check that all color luminance points settle within each color reproduction frame. (Fig. 6-1-11)

2 3 4 5 6 7 8 9 10 11

0 F E E E E 6 6 6

01 5E 62 63 64 65 01 01 02

01 2D 00 00 20 20 C3 C1

2 3 4 5 6 7 8 9 10 11

0 F E E E E 6 6 6

01 5E 90 91 92 93 01 01 02

01 2D 00 00 20 20 CB C9

12

12

Note3: The adjustment data will be automatically input to page: E, address: 62 to 65.

Note3: The adjustment data will be automatically input to page: E, address: 90 to 93.

Processing after Completing Adjustments Order Page Address Data Procedure 1 2 3 3 6 6 F 0 01 02 5E 01 00 00 1D 00 Set the data, and press PAUSE button. Set the data. Set the data, and press PAUSE button. Set the data.

Processing after Completing Adjustments Order Page Address Data Procedure 1 2 3 4 5 6 6 F 0 01 02 5E 01 00 00 1D 00 Set the data, and press PAUSE button. Set the data. Set the data, and press PAUSE button. Set the data. Set ND FILTER switch to "OFF".

6-24

DCR-VX2100/VX2100E

19. White Balance Check Subject Clear chart (Color bar standard picture frame) Filter Filter C14 for color temperature correction ND filter 1.0 and 0.3 (2 sheets) Video output terminal Vectorscope Fig. 6-1-12. A to B

Processing after Completing Adjustments Order Page Address Data Procedure 1 2 3 4 5 6 6 F F 0 01 04 10 11 01 00 00 00 00 00 Set the data, and press PAUSE button. Set the data. Set the data, and press PAUSE button. Set the data, and press PAUSE button. Set the data.

Measurement Point Measuring Instrument Specified Value

Switch setting: ND FILTER ...................................................................... OFF (The data of page: 6, address: 9D is "00".) Checking method: Order Page Address Data 1 2 3 6 01 0F Procedure Indoor white balance check Check that the lens is not covered with either filter. Set the data, and press PAUSE button. Check that the center of the white luminance point is within the circle shown Fig. 6-1-12. A. Outdoor white balance check 6 01 3F Place the C14 filter on the lens. Set the data, and press PAUSE button. Check that the center of the white luminance point is within the circle shown Fig. 6-1-12. B. Remove the C14 filter. Indoor white balance data check Place the ND filter 1.6 (1.0+0.3+0.3) on the lens. Set the data, and press PAUSE button. Wait for 2 seconds. Set the data. Set the data, and press PAUSE button. Set the data, and press PAUSE button. Check that the second digit of the display data (Note) is an odd number. Specified value: 1 : XX : XX Odd number Set the data. Check that the display data (Note) satisfies the specified value. Specified value: 0000 to 0C50

R-Y

4mm

B-Y

4mm

Fig. 6-1-12. (A)
R-Y 1.0mm

4 5 6

1.0mm

B-Y 6mm

6mm

Fig. 6-1-12. (B)

7 8 9 10 11 12 13 14 6 01 0F

0 F F 1

01 10 11

01 A1 04

15 16

6 1

04

C6

Note: Displayed data of the adjustment remote commander. 1 : XX : XX Display data

6-25

DCR-VX2100/VX2100E

20. Steady Shot Adjustment · This adjustment is performed only when replacing the angular velocity sensor. Although this adjustment need not be performed when the circuit is damaged, etc., check the operations. · Note down the sensitivity displayed on the angular velocity sensor of the repair parts. At this time, note down also to which board it was attached to. Be sure to check because if attached incorrectly, the screen will vibr