Text preview for : SONY HDR-HC1, HC1E, HC1K, HC1EK SECTION 6 ADJUSTMENTS ADJ VER 1.2 2007.09 (9-876-883-53).pdf part of SONY HDR-HC1 SONY HDR-HC1, HC1E, HC1K, HC1EK.
DIGITAL HD VIDEO CAMERA RECORDER.
SECTION 6 ADJUSTMENTS VERSION 1.2 2007.09
PART#(9-876-883-53).
Back to : SONY HDR-HC1, HC1E, HC1K, | Home
HDR-HC1/HC1E/HC1K/HC1EK
RMT-831
Ver. 1.2 2007.09
Revision History
SECTION 6 ADJUSTMENTS
ADJ
Link
Before starting adjustments
Adjusting items when replacing main parts and boards List of service tools
VIDEO SECTION ADJUSTMENTS
PREPARATIONS BEFORE ADJUSTMENTS SYSTEM CONTROL SYSTEM ADJUSTMENTS SERVO AND RF SYSTEM ADJUSTMENTS
CAMERA SECTION ADJUSTMENTS
VIDEO SYSTEM ADJUSTMENTS
PREPARATIONS BEFORE ADJUSTMENTS
AUDIO SYSTEM ADJUSTMENTS
INITIALIZATION OF EEPROM DATA CAMERA SYSTEM ADJUSTMENTS ELECTRONIC VIEWFINDER SYSTEM ADJUSTMENTS LCD SYSTEM ADJUSTMENTS
SERVICE MODE
ADJUSTMENT REMOTE COMMANDER DATA PROCESS SERVICE MODE
MECHANISM SECTION ADJUSTMENTS
HOW TO ENTER RECORD MODE WITHOUT CASSETTE HOW TO ENTER PLAYBACK MODE WITHOUT CASSETTE TAPE PATH ADJUSTMENT
NTSC MODEL: HDR-HC1/HC1K PAL MODEL: HDR-HC1E/HC1EK
HDR-HC1/HC1E/HC1K/HC1EK_ADJ
9-876-883-52
Sony EMCS Co.
2007I0500-1 © 2007.9 Published by Kohda TEC
TABLE OF CONTENTS
Section Title Page
6.
ADJUSTMENTS
Before Starting Adjustments ····················································· 6-1 1-1. Adjusting Items when Replacing Main Parts and Boards ·············································································· 6-2 1-2. List of Service Tools ························································ 6-4 6-1. Camera Section Adjustments ··········································· 6-5 1-1. Preparations before Adjustments (CAMERA Section) ··· 6-5 1-2. Initialization of EEPROM Data ······································· 6-8 1-3. Camera System Adjustments ········································· 6-28 1-4. Electronic Viewfinder System Adjustments ·················· 6-56 1-5. LCD System Adjustments ············································· 6-61 6-2. Mechanism Section Adjustments ·································· 6-64 2-1. How To Enter Record Mode Without Cassette ·············· 6-64 2-2. How To Enter Playback Mode Without Cassette ·········· 6-64 2-3. Tape Path Adjustment ···················································· 6-64 6-3. Video Section Adjustments ··········································· 6-65 3-1. Preparations Before Adjustments ·································· 6-65 3-2. System Control System Adjustments ···························· 6-67 3-3. Servo and RF System Adjustments ······························· 6-69 3-4. Video System Adjustments ············································ 6-71 3-5. Audio System Adjustments ··········································· 6-75 6-4. Service Mode ································································· 6-76 4-1. Adjustment Remote Commander ·································· 6-76 4-2. Data Process ·································································· 6-77 4-3. Service Mode ································································· 6-78
* The color reproduction frame is shown on page 6-87, 88
HDR-HC1/HC1E/HC1K/HC1EK_ADJ --2--
SECTION 6 ADJUSTMENTS
1.
Before starting adjustments EVR Data Re-writing Procedure When Replacing Board
The data that is stored in the repair board, is not necessarily correct. Perform either procedure 1 or procedure 2 or procedure 3 when replacing board.
Procedure 1
Save the EVR data of the machine in which a board is going to be replaced. Download the saved data after a board is replaced.
(Machine before starting repair) PC PC (Machine after a board is replaced)
Save the EVR data to a personal computer.
Download the saved data to a machine.
Procedure 2
Remove the EEPROM from the board of the machine that is going to be repaired. Install the removed EEPROM to the replaced board.
Remove the EEPROM and install it.
(Former board)
(New board)
Procedure 3
When the data cannot be saved due to defective EEPROM, or when the EEPROM cannot be removed or installed, save the data from the same model of the same destination, and download it.
(Machine to be repaired) PC (Machine to be repaired)
Download the data. Save the data.
(The same model of the same destination)
After the EVR data is saved and downloaded, check the respective items of the EVR data. (Refer to page 6-3 for the items to be checked)
HDR-HC1/HC1E/HC1K/HC1EK_ADJ 6-1
1-1. Adjusting items when replacing main parts and boards · Adjusting items when replacing main parts When replacing main parts, adjust the items indicated by z in the following table. Note 1: When replacing the drum assy or the mechanism deck, reset the data of page: 7, address: A8 to AB to "00". (Refer to "Record of Use check" of "6-4. SERVICE MODE")
Replaced part Block replacement
(LCD panel, Touch panel) (Back light LED) (LCD panel) (Control switch block (zoom lever))
Mounted part replacement
(CMOS imager) (PITCH, YAW sensor) (Clock generator) (CDS, A/D converter) (Base band signal process, etc) (DV signal process) (Video IN/OUT) (Component out AMP) (REC/PB AMP) (EVF driver) (Timing generator (EVF)) (Back light (EVF)) (LCD driver, Timing generator (LCD))
z z z z z z z z z z z z z z z z z z z z z z z z z z z z z z z z z z z z z z z z z z z z z z z z
Adjustment Section
Adjustment
Initialization of EEPROM data
Camera
EVF
LCD
Mechanism System control Servo, RF
Video
Initialization of A, B, D, 1A, 1B page data Initialization of 8, C, 13, 18, 1C page data Initialization of 9, 1D page data Initialization of F, 63 to 6F page data Origin oscillation check HALL adj. MR adj. Image sensor output 2ch matching adj. Flange back and zoom lever center adj. F No. & ND light quality standard data input Mechanical shutter adj. Auto white balance standard data input LV standard data input Auto white balance adj. Color reproduction adj. PCGM standard data input MAX GAIN adj. White defect Adj. Black defect Adj. Strobe light level adj. Strobe white balance adj. Steadyshot check VCO adj. Back light adj. PSIG adj. V-COM level adj. RGB AMP adj. Contrast adj. White balance adj. LCD automatic adj. V-COM adj. Transmissive mode white balance adj. Reflective mode white balance adj. Touch panel adj. Tape path adj. Node uniqe ID No. input CAP FG duty adj. Switching position adj. Error rate check S VIDEO OUT Y level adj. S VIDEO OUT chroma level adj. COMPONENT OUT Y level adj. COMPONENT OUT Pr level adj. COMPONENT OUT Pb level adj.
Table 6-1-1 (1)
HDR-HC1/HC1E/HC1K/HC1EK_ADJ 6-2
Lens device LCD block LCD9001 LCD block D9001 EVF block LCD9002 PS12300 block Flash unit FL12300 Mechanism deck (Note 1) Mechanism deck M9001 Mechanism deck MD block EE-001 board IC6601 EE-001 board SE6801, 6802 TT-001 board IC1403, X1401 TT-001 board IC1201 TT-001 board IC2201 TT-001 board IC4001 TT-001 board IC4401 TT-001 board IC2401 NN-001 board IC7601 NN-001 board IC7801 NN-001 board IC7802 UU-001 board D9801 PP-001 board IC8701
z z z z z z z z z z z z z z z z z z z z z z z z z z
(Drum assembly) (Note 1)
· Adjusting items when replacing a board or EEPROM When replacing a board or EEPROM, adjust the items indicated by z in the following table.
Replaced part
Adjustment Section
Adjustment
Initialization of EEPROM data
Camera
EVF
LCD
Mechanism System control Servo, RF
Video
Initialization of A, B, D, 1A, 1B page data Initialization of 8, C, 13, 18, 1C page data Initialization of 9, 1D page data Initialization of F, 63 to 6F page data Origin oscillation check HALL adj. MR adj. Image sensor output 2ch matching adj. Flange back and zoom lever center adj. F No. & ND light quality standard data input Mechanical shutter adj. Auto white balance standard data input LV standard data input Auto white balance adj. Color reproduction adj. PCGM standard data input MAX GAIN adj. White defect Adj. Black defect Adj. Strobe light level adj. Strobe white balance adj. Steadyshot check VCO adj. Back light adj. PSIG adj. V-COM level adj. RGB AMP adj. Contrast adj. White balance adj. LCD automatic adj. V-COM adj. Transmissive mode white balance adj. Reflective mode white balance adj. Touch panel adj. Tape path adj. Node uniqe ID No. input CAP FG duty adj. Switching position adj. Error rate check S VIDEO OUT Y level adj. S VIDEO OUT chroma level adj. COMPONENT OUT Y level adj. COMPONENT OUT Pr level adj. COMPONENT OUT Pb level adj.
z z
z z z z z z z z
z
z z z z z z z z z z z z z z z z z z z z z z z z z z z z z z z z z z
z z z z z z z z z z z z z z z z z z z z z z z z z z z z z z z z z z z z z z z z z z z z z z z z z z z z z z z z z z z z z z z z z z z z z z z z
Note 2: When the repair is finished, confirm the following items. 1. Shoot the all black subject (Attach the lens cap and shoot), and confirm that a vertical line is not displayed in the center of the screen, and that there is no difference in left-right brightness level of the screen. 2. Shoot a subject of low light, and confirm that a vertical line is not displayed in the center of the screen, and that there is no difference in left-right brightness level of the screen. 3. Shoot a subject of normal light, and confirm that a vertical line is not displayed in the center of the screen, and that there is no difference in left-right brightness level of the screen. When the above symptom occurs, perform the whole process of "Image Sensor Output 2ch Matching Adjustment". Note 3: IC4802 (HI/DS control with built-in flash memory) on the TT-001 board cannot be replaced.
(COMPLETE) (COMPLETE) (COMPLETE) (COMPLETE) (COMPLETE) (EEPROM) (EEPROM) (EEPROM) EE-001 board TT-001 board NN-001 board UU-001 board PP-001 board TT-001 board IC4801 TT-001 board IC5402 TT-001 board IC5801
z z z z z z z z z z
Table 6-1-1 (2)
HDR-HC1/HC1E/HC1K/HC1EK_ADJ 6-3
Supporting
z z z z z
RadarW
1-2. List of service tools · Oscilloscope · Digital voltmeter
J-1
· Color monitor · Frequency counter
J-2
· Vectorscope · Audio level meter
J-3 Pattern box PTB-450 J-6082-200-A or Small pattern box PTB-1450 J-6082-557-A Color bar chart For PTB-450: J-6020-250-A For PTB-1450: J-6082-559-A J-6 Flange back adjustment jig J-6082-563-A
Adjustment remote commander J-6082-053-B
J-4 Clear chart For PTB-450: J-6080-621-A For PTB-1450: J-6082-560-A J-7
J-5
Minipattern box J-6082-353-B
J-8 Filter for color temperature correction (C14) J-6080-058-A
J-9 ND filter 1.0 J-6080-808-A ND filter 0.4 J-6080-806-A ND filter 0.1 J-6080-807-A J-12 Tracking standard (XH2-1) 8-967-997-01
Siemens star chart J-6080-875-A
J-10
J-11
Back ground paper J-2501-130-A
Camera table J-6082-384-A
J-13 SW/OL standard (XH2-3) 8-967-997-11
J-14
Audio operation check for NTSC (XH5-3) 8-967-997-51 for PAL (XH5-3P) 8-967-997-55
J-15
System operation check for NTSC (XH5-5) 8-967-997-61 for PAL (XH5-5P) 8-967-997-66
J-16 CPC-7 jig J-6082-382-A
J-17
AC power adaptor 1-479-283-12
Fig. 6-1-1
HDR-HC1/HC1E/HC1K/HC1EK_ADJ 6-4
6-1. CAMERA SECTION ADJUSTMENTS
1-1.
1-1-1.
PREPARATIONS BEFORE ADJUSTMENTS (CAMERA SECTION)
Preparations
Pattern box L L = 1 m (PTB-450) L = 40 cm (PTB-1450) Front of the lens Camera
Note: Before perform the adjustment, check that the data of page: 0, address: 10 is "00". If not, select page: 0, address: 10, and set data "00". 1) Connect the equipment for adjustments according to Fig. 6-1-3.
Fig. 6-1-2
TT-001 board 16 1 CN7005
NN-001 board
Adjustment remote commander (RM-95)
S Video (Black) Color monitor Video (Yellow) Audio L (White) Audio R (Red)
LANC jack
Vectorscope Terminated 75
A/V jack
DC IN jack 16 1
AC IN AC adaptor
CPC-7 jig (J-6082-382-A) EVF system adjustment
Fig. 6-1-3
HDR-HC1/HC1E/HC1K/HC1EK_ADJ 6-5
1-1-2. Precaution 1. Setting the Switch Unless otherwise specified, set the switches as follows and perform adjustments without loading cassette. 1. 2. 3. 4. 5. 6. 7. 8. 9. POWER switch (PS12300 block) .............. CAMERA-TAPE BACK LIGHT (CK12300 block) ................................... OFF FOCUS switch (CK12300 block) ........................ MANUAL EXPOSE switch (CK12300 block) ............................. AUTO NIGHT SHOT switch (FP-245 flexble) ......................... OFF PROGRAM AE (MENU setting) ................................ AUTO SPOT METER (MENU setting) ................................. AUTO WHITE BAL. (MENU setting) ................................... AUTO AE SHIFT (MENU setting) ................................................. 0 10. 11. 12. 13. 14. 15. 16. 17. WB SHIFT (MENU setting) ................................................ 0 COLOR SLOWS (MENU setting) ................................. OFF DIGITAL ZOOM (MENU setting) ................................ OFF STEADY SHOT (MENU setting) .................................. OFF DIGITAL EFFECT (MENU setting) ............................. OFF PICTURE EFFECT (MENU setting) ............................ OFF DEMO MODE (MENU setting) .................................... OFF REC FORMAT (MENU setting) ......................... HDV 1080i
2. Order of Adjustments Basically carry out adjustments in the order given. Color bar chart (Color reproduction adjustment frame)
Yellow Cyan Green White Magenta Red
H Electronic beam scanning frame C C=D=0 D
Blue
Magenta
Yellow
Green
White
Cyan
Blue
Red
CRT picture frame
Fig. b (monitor TV picture)
A B A=B B A Enlargement V
Fig. a (VIDEO terminal of A/V jack output waveform)
Difference in level
B
A
Adjust the camera zoom and direction to obtain the output waveform shown in Fig. a and the monitor TV display shown in Fig. b.
Fig. 6-1-4
3. Subjects 1) Color bar chart (Color reproduction adjustment frame) When performing adjustments using the color bar chart, adjust the picture frame as shown in Fig. 6-1-4. (Color reproduction adjustment frame) 2) Clear chart (All whire frame) Remove the color bar chart from pattern box and insert a clear chart in its place. (Then adjust the zoom to TELE side from WIDE side, and stop it when the black frame of the chart disappears.) 3) Chart for flange back adjustment Join together a piece of white A0 size paper (1189mm × 841 mm) and a piece of black paper to make the chart shown in Fig. 6-1-5. Note: Use a non-reflecting and non-glazing vellum paper. The size must be A0 or larger and the joint between the white and black paper must not have any undulations.
White 841 mm Black
1189 mm
Fig. 6-1-5
HDR-HC1/HC1E/HC1K/HC1EK_ADJ 6-6
4. Preparing the Flash Adjustment Box A dark room is required to provide an accurate flash adjustment. If it is not available, prepare the flash adjustment box as given below; 1) Provide woody board A, B and C of 15 mm thickness.
woody board A (2) 400 mm woody board B (2) 370 mm woody board C (1) 700 mm
513 mm
513 mm
700 mm
730 mm
700 mm
Fig. 6-1-6
2) Apply black mat paint to one side of woody board A and B. 3) Attach background paper (J-2501-130-A) to woody board C. 4) Assemble so that the black sides and the background paper side of woody board A, B and C are internal. (Fig. 6-1-7)
woody board A
woody board B
woody board A
woody board B woody board C
Fig. 6-1-7
HDR-HC1/HC1E/HC1K/HC1EK_ADJ 6-7
1-2.
INITIALIZATION OF EEPROM DATA
Note 1: Pages used for the EEPROM consists of 26 pages. There are 8, 9, A to D, F, 13, 18, 1A to 1D, 63 to 6F pages. Note 2: When reading or writing the 13, 18, 1A, 1B, 1C or 1D page data, select page: 0, address: 10, and set data: 01, then sclect 3, 8, A, B, C or D page. The 13, 18, 1A, 1B, 1C or 1D page can be chosen by this data setting. After reading or writing, reset the data or page: 0, address: 10 to "00". Note 3: When reading or writing the 63 to 6F page data, select page: 0, address: 10, and set data: 06, then select 3, 4, 5, 6, 7, 8, 9, A, B, C, D, E, or F page. The 63, 64, 65, 66, 67, 68, 69, 6A, 6B, 6C, 6D, 6E, or 6F page can be chosen by this data setting. After reading or writing, reste the data of page: 0, address: 10 to "00". 1-2-1. Initialization of A, B, D, 1A, 1B Page Data Note: Check that the data of page: 0, address: 10 is "00". 1. Initializing of A, B, D, 1A, 1B Page Data Note: If the A, B, D, 1A, 1B page data has been initialized, the following adjustments need to be performed again. 1) Modification of A, B, D, 1A, 1B page data 2) Touch panel adjustment Adjustment Page Adjustment Address Adjustment Page Adjustment Address Adjustment Page Adjustment Address Adjustment Page Adjustment Address Adjustment Page Adjustment Address Initializing method: Order Page Address Data 1 2 3 0 0 7 01 10 04 01 00 Set the following data 70: NTSC model 71: PAL model Set the following data 20: Initializing A page 21: Initializing B page 22: Initializing D page 23: Initializing 1A page 24: Initializing 1B page 25: Initializing A and 1A page 26: Initializing B and 1B page 28: Initializing A, B, D, 1A and 1B page 01 Press PAUSE button. Check the data changes to "01". Perform "Modification of A, B, D, 1A, 1B Page Data" Procedure A 10 to FF B 00 to FF D 10 to FF 1A 00 to FF 1B 00 to FF
2. Modification of A, B, D, 1A, 1B Page Data If the A, B, D, 1A, 1B page data has been initialized, change the data of the "Fixed data-2" address shown in the following table by manual input. Modifying Method: 1) Before changing the data, select page: 0, address: 01, and set data: 01. 2) If modification of data on pages A, B, D, set data: 00 to page: 0, address: 10, and then select pages A, B, D. 3) If modification of data on pages 1A, 1B, set data: 01 to page: 0, address: 10, and then select pages A, B. After the modification of data finished, return the data on page: 0, address: 10 to "00". 4) New data for changing are not shown in the tables because they are different in destination. When changing the data, copy the data built in the same model. Note 1: If copy the data built in the different model, the camcorder may not operate. 5) When changing the data, press the PAUSE button of the adjustment remote commander each time when setting new data to write the data in the non-volatile memory. 6) Check that the data of adjustment addresses is the initial value. If not, change the data to the initial value. Processing after Completing Modification A, B, D, 1A, 1B page data: Order Page Address Data 1 2 3 0 2 2 10 00 01 00 29 29 Press PAUSE button. Procedure
Note 2: If following symptoms occur after completing of the "Modification A, B, D, 1A, 1B page data", check that the data of the "Fixed data-2" address of A, B, D, 1A, 1B page are same as those of same model of same destination. 1) The power is shut off so that unit cannot operate.
4
7
01
5 6 7
7 7
00 02
HDR-HC1/HC1E/HC1K/HC1EK_ADJ 6-8
3. A Page table Note 1: Check that the data of page: 0, address: 10 is"00". Note 2: Fixed data-1: Initialized data. (Refer to"1. Initializing the A, B, D, 1A, 1B Page Data") Fixed data-2: Modified data. (Refer to"2. Modification of A, B, D, 1A, 1B Page Data") Initial value Address Remark NTSC PAL 10 11 to 17 18 19 to 2E 2F 30 31 32 to 8F 90 91 92 93 94 to F1 F2 F3 to FF E8 10 D4 18 EB 0D C7 25 Fixed data-1 (Initialized data) Fixed data-2 Fixed data-1 (Initialized data) Touch panel adj. 00 00 Test mode Fixed data-1 (Initialized data) Fixed data-2 Fixed data-1 (Initialized data) Fixed data-2 Fixed data-1 (Initialized data) Fixed data-2 Fixed data-1 (Initialized data)
5. D Page table Note 1: Check that the data of page: 0, address: 10 is "00". Note 2: Fixed data-1: Initialized data. (Refer to "1. Initializing the A, B, D, 1A, 1B Page Data") Fixed data-2: Modified data. (Refer to "2. Modification of A, B, D, 1A, 1B Page Data") Initial value Address Remark NTSC PAL 10 to 13 14 15 16 17 to 27 28 29 2A 2B 2C 2D 2E 2F 30 31 to FF Fixed data-1 (Initialized data) Fixed data-2 Fixed data-1 (Initialized data) Fixed data-2 Fixed data-1 (Initialized data) Fixed data-2 Fixed data-1 (Initialized data)
4. B Page table Note 1: Check that the data of page: 0, address: 10 is "00". Note 2: Fixed data-1: Initialized data. (Refer to "1. Initializing the A, B, D, 1A, 1B Page Data") Fixed data-2: Modified data. (Refer to "2. Modification of A, B, D, 1A, 1B Page Data") Initial value Address Remark NTSC PAL 00 to FF Fixed data-1 (Initialized data)
6. 1A Page table Note 1: If reading/writing data on pages 1A, set data: 01 to page: 0, address: 10, and then select pages: A. By this data setting, the pages 1A can be selected. After the data reading/writing finished, return the data on page: 0, address: 10 to "00". Note 2: Fixed data-1: Initialized data. (Refer to "1. Initializing the A, B, D, 1A, 1B Page Data") Fixed data-2: Modified data. (Refer to "2. Modification of A, B, D, 1A, 1B Page Data") Initial value Address Remark NTSC PAL 00 to FF Fixed data-1 (Initialized data)
7. 1B Page table Note 1: If reading/writing data on pages 1B, set data: 01 to page: 0, address: 10, and then select pages: B. By this data setting, the pages 1B can be selected. After the data reading/writing finished, return the data on page: 0, address: 10 to "00". Note 2: Fixed data-1: Initialized data. (Refer to "1. Initializing the A, B, D, 1A, 1B Page Data") Fixed data-2: Modified data. (Refer to "2. Modification of A, B, D, 1A, 1B Page Data") Initial value Address Remark NTSC PAL 00 to FF Fixed data-1 (Initialized data)
HDR-HC1/HC1E/HC1K/HC1EK_ADJ 6-9
1-2-2.
Initialization of 8, C, 13, 18, 1C Page Data
1. Initializing of 8, C, 13, 18, 1C Page Data Note1: If "Initialization of Pages 8, C, 13, 18, 1C" is executed, all data on pages 8, C, 13, 18, 1C are initialized. (Only an individual page cannot be initialized) Note2 : If the 8, C, 13, 18, 1C page data has been initialized, the following adjustments need to be performed again. 1) Modification of 8, C, 13, 18, 1C page data 2) Electronic viewfinder system adjustments (if all areas were initialized) 3) LCD system adjustments (if all areas were initialized) 4) Node unique ID No. input (if all areas were initialized) 5) Servo, RF system adjustments (if all areas were initialized) 6) Video system adjustments (if all areas were initialized) Adjustment Page Adjustment Address Adjustment Page Adjustment Address Adjustment Page Adjustment Address Adjustment Page Adjustment Address Adjustment Page Adjustment Address Initializing method: Order Page Address Data 1 2 0 0 01 10 01 00 Set the following data, and press PAUSE button. (Note 3) 00: Initializing all areas 01: Initializing other than adjustment address 0C Press PAUSE button. Check the data changes to "1C". Perform "Modification of 8, C, 18, 1C Page Data" Procedure 8 00 to FF C 10 to FF 13 00 to FF 18 00 to FF 1C 00 to FF
2. Modification of 8, C, 13, 18, 1C Page Data If the 8, C, 13, 18, 1C page data has been initialized, change the data of the "Fixed data-2" address shown in the following table by manual input. Modifying Method: 1) Before changing the data, select page: 0, address: 01, and set data: 01. 2) If modification of data on pages 8, C, set data: 00 to page: 0, address: 10, and then select pages 8, C. 3) If modification of data on pages 13, 18, 1C, set data: 01 to page: 0, address: 10, and then select pages 3, 8, C. After the modification of data finished, return the data on page: 0, address: 10 to "00". 4) New data for changing are not shown in the tables because they are different in destination. When changing the data, copy the data built in the same model. Note: If copy the data built in the different model, the camcorder may not operate. 5) When changing the data, press the PAUSE button of the adjustment remote commander each time when setting new data to write the data in the non-volatile memory. 6) If all areas were initialized, check that the data at the addresses for adjustment are initial values (adjustment initial values) listed in the table. If different, change them to the adjustment initial values. Processing after Completing Modification 8, C, 13, 18, 1C page data: Order Page Address Data 1 2 3 0 2 2 10 00 01 00 29 29 Press PAUSE button. Procedure
3
3
81
4 5 6
3 3
80 80
3. 8 Page table Note 1: Check that the data of page: 0, address: 10 is"00". Note 2: Fixed data-1: Initialized data. (Refer to "1. Initializing the 8, C, 13, 18, 1C Page Data") Fixed data-2: Modified data. (Refer to "2. Modification of 8, C, 13, 18, 1C Page Data") Initial value Address Remark NTSC PAL 00 to 78 79 7A 7B 7C, 7D 7E 7F to FF Fixed data-1 (Initialized data) Fixed data-2 Fixed data-1 (Initialized data) Fixed data-2 Fixed data-1 (Initialized data)
Note 3: If other than adjustment address was initialized, the adjusted data is not initialized.
HDR-HC1/HC1E/HC1K/HC1EK_ADJ 6-10
4. C Page table Note 1: Check that the data of page: 0, address: 10 is "00". Note 2: Fixed data-1: Initialized data. (Refer to "1. Initializing the 8, C, 13, 18, 1C Page Data") Fixed data-2: Modified data. (Refer to "2. Modification of 8, C, 13, 18, 1C Page Data") Initial value Address Remark NTSC PAL 10 11 12 13 14, 15 16 17 to 24 25 26 27 28 to 31 32 33 34 35 36 37 38 39 3A 3B 3C to 41 42 43, 44 45 46 47 48 to 4A 4B 4C 4D 4E to 6F 70 71 72 to 76 77 78 to 81 82 83 75 36 75 36 38 38 99 8E 99 8E 80 80 66 80 80 66 6C 78 B7 6C 78 B7 4E 80 80 4E 80 80 53 9D 80 80 A9 8E 53 9D 80 80 A9 8E 70 2A 2A - - - E0 E0 EE 00 00 00 EE 00 00 00 Fixed data-1 (Initialized data) CAP FG duty adj. Fixed data-1 (Initialized data) S VIDEO OUT Y level adj. (NTSC)/ Fixed data-1 (PAL) S VIDEO OUT chroma level adj. (NTSC)/Fixed data-1 (PAL) Fixed data-1 (Initialized data) Back light adj. (EVF) VCO adj. (EVF) V-COM level adj. (EVF) RGB AMP adj. (EVF) Fixed data-1 (Initialized data) PSIG level adj. (EVF) White balance adj. (EVF) Fixed data-1 (Initialized data) Fixed data-2 Fixed data-1 (Initialized data) LCD automatic adj. (VCO) V-COM adj. Fixed data-1 (Initialized data) Transmissive mode white balance adj. LCD automatic adj. (Contrast) Fixed data-1 (Initialized data) Reflective mode white balance adj. Fixed data-1 (Initialized data) Contrast adj. (EVF) Fixed data-1 (Initialized data) COMPONENT OUT Y level adj. COMPONENT OUT Pr level adj.
Address 84 85 86 87
Initial value NTSC PAL 36 - - - 36 70 2A 2A
Remark COMPONENT OUT Pb level adj. Fixed data-1 (NTSC)/ S VIDEO OUT Y level adj. (PAL) Fixed data-1 (NTSC)/ S VIDEO OUT chroma level adj. (PAL) Fixed data-1 (Initialized data)
Switching position adj. 88 to F3 F4 F5 F6 F7 F8 F9 FA FB FC FD FE FF 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 Emergence memory address (Mechanism section)
HDR-HC1/HC1E/HC1K/HC1EK_ADJ 6-11
5. 13 Page table Note 1: If reading/writing data on pages 13, set data: 01 to page: 0, address: 10, and then select pages: 3. By this data setting, the pages 13 can be selected. After the data reading/writing finished, return the data on page: 0, address: 10 to "00". Note 2: Fixed data-1: Initialized data. (Refer to "1. Initializing the 8, C, 13, 18, 1C Page Data") Fixed data-2: Modified data. (Refer to "2. Modification of 8, C, 13, 18, 1C Page Data") Initial value Address Remark NTSC PAL 00 to 03 04 05 06 07 08 09 0A 0B 0C to 0F 10 11 12 13 14 to 23 24 25 26 to B8 B9 BA to C0 C1 C2 C3 C4 C5 C6 C7 C8 C9 CA CB CC CD CE CF D0 to D7 D8 D9 DA Fixed data-1 (Initialized data) Fixed data-2 Fixed data-1 (Initialized data) Fixed data-2 Fixed data-1 (Initialized data) Fixed data-2 Fixed data-1 (Initialized data) Fixed data-2 Fixed data-1 (Initialized data) Fixed data-2 08 00 46 01 02 00 00 00 08 00 46 01 02 00 00 00 Fixed data-1 (Initialized data) Node unique ID No. input Fixed data-1 (Initialized data)
Address DB DC DD to FF
Initial value NTSC PAL Fixed data-2
Remark
Fixed data-1 (Initialized data)
HDR-HC1/HC1E/HC1K/HC1EK_ADJ 6-12
6. 18 Page table Note 1: If reading/writing data on pages 18, set data: 01 to page: 0, address: 10, and then select pages: 8. By this data setting, the pages 18 can be selected. After the data reading/writing finished, return the data on page: 0, address: 10 to "00". Note 2: Fixed data-1: Initialized data. (Refer to "1. Initializing the 8, C, 13, 18, 1C Page Data") Fixed data-2: Modified data. (Refer to "2. Modification of 8, C, 13, 18, 1C Page Data") Initial value Address Remark NTSC PAL 00 to 08 09 0A 0B 0C to 12 13 14 15 16, 17 18 19 1A 1B 1C 1D 1E 1F to 76 77 78 79 7A to FF Fixed data-1 (Initialized data) Fixed data-2 Fixed data-1 (Initialized data) Fixed data-2 Fixed data-1 (Initialized data) Fixed data-2 Fixed data-1 (Initialized data) Fixed data-2 Fixed data-1 (Initialized data) Fixed data-2 Fixed data-1 (Initialized data) Fixed data-2 Fixed data-1 (Initialized data) Fixed data-2 Fixed data-1 (Initialized data) Fixed data-2 Fixed data-1 (Initialized data)
7. 1C Page table Note 1: If reading/writing data on pages 1C, set data: 01 to page: 0, address: 10, and then select pages: C. By this data setting, the pages 1C can be selected. After the data reading/writing finished, return the data on page: 0, address: 10 to"00". Note 2: Fixed data-1: Initialized data. (Refer to "1. Initializing the 8, C, 13, 18, 1C Page Data") Fixed data-2: Modified data. (Refer to "2. Modification of 8, C, 13, 18, 1C Page Data") Initial value Address Remark NTSC PAL 00 to 5F 60 61 62 to 68 69 6A 6B to B2 B3 B4 B5 B6 B7 B8 B9 BA BB BC BD BE BF C0 C1 C2 C3 C4 C5 C6 C7 C8 C9 to FF 00 00 00 00 00 80 00 00 00 00 00 00 00 00 00 00 80 00 00 00 00 00 00 00 00 00 00 80 00 00 00 00 00 00 00 00 00 00 80 00 00 00 00 00 Fixed data-1 (Initialized data) Error rate check Fixed data-1 (Initialized data) Fixed data-2 Fixed data-1 (Initialized data) Fixed data-2 Fixed data-1 (Initialized data)
HDR-HC1/HC1E/HC1K/HC1EK_ADJ 6-13
1-2-2.
Initialization of 9, 1D Page Data
1. Initializing of 9, 1D Page Data Note1: If "Initialization of Pages 9, 1D" is executed, all data on pages 9, 1D are initialized. (Only an individual page cannot be initialized) Note2 : If the 9, 1D page data has been initialized, the following adjustments need to be performed again. 1) Modification of 9, 1D page data Adjustment Page Adjustment Address Adjustment Page Adjustment Address Initializing method: Order Page Address Data 1 2 3 4 5 6 0 0 3 3 3 01 10 81 80 80 01 00 00 04 Press PAUSE button. Check the data changes to "14". Perform "Modification of 9, 1D Page Data" Procedure 9 10 to FF 1D 00 to FF
2. Modification of 9, 1D Page Data If the 9, 1D page data has been initialized, change the data of the "Fixed data-2" address shown in the following table by manual input. Modifying Method: 1) Before changing the data, select page: 0, address: 01, and set data: 01. 2) If modification of data on pages 9, set data: 00 to page: 0, address: 10, and then select pages 9. 3) If modification of data on pages 1D, set data: 01 to page: 0, address: 10, and then select pages D. After the modification of data finished, return the data on page: 0, address: 10 to "00". 4) New data for changing are not shown in the tables because they are different in destination. When changing the data, copy the data built in the same model. Note: If copy the data built in the different model, the camcorder may not operate. 5) When changing the data, press the PAUSE button of the adjustment remote commander each time when setting new data to write the data in the non-volatile memory. 6) Check that the data at the addresses for adjustment are initial values (adjustment initial values) listed in the table. If different, change them to the adjustment initial values. Processing after Completing Modification 9, 1D page data: Order Page Address Data 1 2 3 0 2 2 10 00 01 00 29 29 Press PAUSE button. Procedure
3. 9 Page table Note 1: Check that the data of page: 0, address: 10 is "00". Note 2: Fixed data-1: Initialized data. (Refer to "1. Initializing the 9, 1D Page Data") Fixed data-2: Modified data. (Refer to "2. Modification of 9, 1D Page Data") Initial value Address Remark NTSC PAL 00 to FF Fixed data-1 (Initialized data)
4. 1D Page table Note 1: If reading/writing data on pages 1D, set data: 01 to page: 0, address: 10, and then select pages: D. By this data setting, the pages 1D can be selected. After the data reading/writing finished, return the data on page: 0, address: 10 to "00". Note 2: Fixed data-1: Initialized data. (Refer to "1. Initializing the 9, 1D Page Data") Fixed data-2: Modified data. (Refer to "2. Modification of 9, 1D Page Data") Initial value Address Remark NTSC PAL 00 to 2B 2C 2D, 2E 2F 30 to FF Fixed data-1 (Initialized data) Fixed data-2 Fixed data-1 (Initialized data) Fixed data-2 Fixed data-1 (Initialized data)
HDR-HC1/HC1E/HC1K/HC1EK_ADJ 6-14
1-2-3.
Initialization of F, 63 to 6F Page Data
1. Initializing of F, 63 to 6F Page Data Note 1: If "Initialization of Pages F, 63 to 6F" is executed, all data on pages F, 63 to 6F are initialized. (Only an individual page cannot be initialized) Note 2: If the F, 63 to 6F page data has been initialized, the following adjustments need to be performed again. 1) Modification of F, 63 to 6F page data 2) Camera system adjustment Adjustment Page Adjustment Address Adjustment Page Adjustment Address Adjustment Page Adjustment Address Adjustment Page Adjustment Address Adjustment Page Adjustment Address Adjustment Page Adjustment Address Adjustment Page Adjustment Address Adjustment Page Adjustment Address Adjustment Page Adjustment Address Adjustment Page Adjustment Address Adjustment Page Adjustment Address Adjustment Page Adjustment Address Adjustment Page Adjustment Address Adjustment Page Adjustment Address F 00 to FF 63 00 to FF 64 00 to FF 65 00 to FF 66 00 to FF 67 00 to FF 68 00 to FF 69 00 to FF 6A 00 to FF 6B 00 to FF 6C 00 to FF 6D 00 to FF 6E 00 to FF 6F 10 to FF
2. Modification of F, 63 to 6F Page Data If the F, 63 to 6F page data has been initialized, change the data of the "Fixed data-2" address shown in the following table by manual input. Modifying Method: 1) Before changing the data, select page: 0, address: 01, and set data: 01. 2) If modification of data on pages F, set data: 00 to page: 0, address: 10, and then select pages F. 3) If modification of data on pages 63 to 6F, set data: 06 to page: 0, address: 10, and then select pages 3 to F. After the modification of data finished, return the data on page: 0, address: 10 to "00". 4) New data for changing are not shown in the tables because they are different in destination. When changing the data, copy the data built in the same model. Note: If copy the data built in the different model, the camcorder may not operate. 5) When changing the data, press the PAUSE button of the adjustment remote commander each time when setting new data to write the data in the non-volatile memory. 6) Check that the data at the addresses for adjustment are initial values (adjustment initial values) listed in the table. If different, change them to the adjustment initial values. Processing after Completing Modification F, 63 to 6F page data: Order Page Address Data 1 2 3 0 2 2 10 00 01 00 29 29 Press PAUSE button. Procedure
Initializing method: Order Page Address Data Procedure 1 2 3 0 0 6 01 10 01 01 00 Set the following data, and press PAUSE button. 2D: NTSC model 2F: PAL model 02 Press PAUSE button. Check the data changes to "01". 00 Press PAUSE button. Perform "Modification of 63 to 6F Page Data"
4 5 6 7
6 6 6
03 02 01
HDR-HC1/HC1E/HC1K/HC1EK_ADJ 6-15
3. F Page table Note 1: Check that the data of page: 0, address: 10 is "00". Note 2: Fixed data-1: Initialized data. (Refer to"1. Initializing the F, 63 to 6F Page Data") Fixed data-2: Modified data. (Refer to"2. Modification of F, 63 to 6F Page Data") Address 00 01 to 14 15 16 17 to 8B 8C 8D to 8F 90 91 92 93 to 95 96 97 98 99 9A 9B to A2 A3 A4 to B0 B1 B2 to BA BB BC, BD BE BF to FF Initial value NTSC PAL Fixed data-2 Fixed data-1 (Initialized data) Fixed data-2 Fixed data-1 (Initialized data) Fixed data-2 Fixed data-1 (Initialized data) Fixed data-2 Fixed data-1 (Initialized data) Fixed data-2 Fixed data-1 (Initialized data) Fixed data-2 Fixed data-1 (Initialized data) Fixed data-2 Fixed data-1 (Initialized data) Fixed data-2 Fixed data-1 (Initialized data) Fixed data-2 Fixed data-1 (Initialized data) Fixed data-2 Fixed data-1 (Initialized data) Fixed data-2 Fixed data-1 (Initialized data) Fixed data-2 Fixed data-1 (Initialized data) Remark
4. 63 Page table Note 1: If reading/writing data on pages 63, set data: 06 to page: 0, address: 10, and then select pages: 3. By this data setting, the pages 63 can be selected. After the data reading/writing finished, return the data on page: 0, address: 10 to "00" Note 2: Fixed data-1: Initialized data. (Refer to "1. Initializing the F, 63 to 6F Page Data") Fixed data-2: Modified data. (Refer to "2. Modification of F, 63 to 6F Page Data") Initial value Address Remark NTSC PAL 00 to 2C 2D 2E to 3B 3C 3D to 54 55 56 to 5C 5D 5E to 6D 6E 6F to 86 87 88 to 8D 8E 8F to 9A 9B 9C 9D, 9E 9F A0 to A6 A7 A8 to FF Fixed data-1 (Initialized data) Fixed data-2 Fixed data-1 (Initialized data) Fixed data-2 Fixed data-1 (Initialized data) Fixed data-2 Fixed data-1 (Initialized data) Fixed data-2 Fixed data-1 (Initialized data) Fixed data-2 Fixed data-1 (Initialized data) Fixed data-2 Fixed data-1 (Initialized data) Fixed data-2 Fixed data-1 (Initialized data) Fixed data-2 Fixed data-1 (Initialized data) Fixed data-2 Fixed data-1 (Initialized data) Fixed data-2 Fixed data-1 (Initialized data)
HDR-HC1/HC1E/HC1K/HC1EK_ADJ 6-16
5. 64 Page table Note 1: If reading/writing data on pages 64, set data: 06 to page: 0, address: 10, and then select pages: 4. By this data setting, the pages 64 can be selected. After the data reading/writing finished, return the data on page: 0, address: 10 to "00". Note 2: Fixed data-1: Initialized data. (Refer to "1. Initializing the F, 63 to 6F Page Data") Fixed data-2: Modified data. (Refer to "2. Modification of F, 63 to 6F Page Data") Initial value Address Remark NTSC PAL 00 to 1F 20 21 22 23 24 25 26 27 28 to2F 30 31 32 33 34 35 36 37 38 39 3A 3B 3C 3D 3E 3F 40 to 49 4A 4B 4C 4D 4E 4F 50 51 52 53 54 55 56 57 Fixed data-2 Fixed data-1 (Initialized data) Fixed data-2 Fixed data-1 (Initialized data) Fixed data-2 Fixed data-1 (Initialized data)
Address 58 59 5A 5B 5C 5D 5E 5F 60 61 62 63 64 65 66 67 68 69 6A 6B 6C 6D 6E 6F 70 71 72 73 74 75 76 77 78 79 7A 7B 7C, 7D 7E 7F 80 81 82 83 84 85 86 87
Initial value NTSC PAL
Remark
Fixed data-2
Fixed data-1 (Initialized data)
Fixed data-2
HDR-HC1/HC1E/HC1K/HC1EK_ADJ 6-17
64 Page table Address 88, 89 8A 8B 8C 8D 8E 8F 90 91 92 93 94 95 96 97 98 99 9A 9B 9C 9D 9E 9F A0 A1 A2 A3 A4 A5 A6 A7 A8 A9 AA to E7 E8 E9 to EC ED EE to FD FE FF Fixed data-1 (Initialized data) Fixed data-2 Fixed data-1 (Initialized data) Fixed data-2 Fixed data-1 (Initialized data) Fixed data-2 Fixed data-2 Initial value NTSC PAL Remark Fixed data-1 (Initialized data)
HDR-HC1/HC1E/HC1K/HC1EK_ADJ 6-18
6. 65 Page table Note 1: If reading/writing data on pages 65 set data: 06 to page: 0, address: 10, and then select pages: 5. By this data setting, the pages 65 can be selected. After the data reading/writing finished, return the data on page: 0, address: 10 to "00" Note 2: Fixed data-1: Initialized data. (Refer to "1. Initializing the F, 63 to 6F Page Data") Fixed data-2: Modified data. (Refer to "2. Modification of F, 63 to 6F Page Data") Initial value Address Remark NTSC PAL 00 01 to 04 05 06 to 08 09 0A to 1F 20 21 22 23 to 2F 30 31 32 to 37 38 39 to 48 49 4A, 4B 4C 4D 4E to 5E 5F 60 to 73 74 75 76 77 to 81 82 83 84 85 to 89 8A 8B 8C 8D 8E 8F 90 91, 92 93 94 to BC BD Fixed data-1 (Initialized data) Fixed data-2 Fixed data-1 (Initialized data) Fixed data-2 Fixed data-2 Fixed data-1 (Initialized data) Fixed data-2 Fixed data-2 Fixed data-1 (Initialized data) Fixed data-2 Fixed data-1 (Initialized data) Fixed data-2 Fixed data-1 (Initialized data) Fixed data-2 Fixed data-1 (Initialized data) Fixed data-2 Fixed data-1 (Initialized data) Fixed data-2 Fixed data-1 (Initialized data) Fixed data-2 Fixed data-1 (Initialized data) Fixed data-2 Fixed data-1 (Initialized data) Fixed data-2 Fixed data-1 (Initialized data) Fixed data-2 Fixed data-1 (Initialized data) Fixed data-2 Fixed data-1 (Initialized data) Fixed data-2 Fixed data-1 (Initialized data)
Address BE, BF C0 C1, C2 C3 C4 to DA DB DC DD DE DF E0 E1 E2 to E7 E8 E9 EA EB EC ED EE EF to F5 F6 F7 to F9 FA FB FC FD FE, FF
Initial value NTSC PAL Fixed data-2
Remark Fixed data-1 (Initialized data) Fixed data-1 (Initialized data) Fixed data-2 Fixed data-1 (Initialized data)
Fixed data-2
Fixed data-1 (Initialized data) Fixed data-2 Fixed data-1 (Initialized data) Fixed data-2 Fixed data-1 (Initialized data) Fixed data-2 Fixed data-1 (Initialized data) Fixed data-2 Fixed data-1 (Initialized data)
Fixed data-2
Fixed data-1 (Initialized data)
HDR-HC1/HC1E/HC1K/HC1EK_ADJ 6-19
7. 66 Page table Note 1: If reading/writing data on pages 66, set data: 06 to page: 0, address: 10, and then select pages: 6. By this data setting, the pages 66 can be selected. After the data reading/writing finished, return the data on page: 0, address: 10 to "00". Note 2: Fixed data-1: Initialized data. (Refer to "1. Initializing the F, 63 to 6F Page Data") Fixed data-2: Modified data. (Refer to "2. Modification of F, 63 to 6F Page Data") Initial value Address Remark NTSC PAL 00 to 0F 10 11 12 13 14 15 to 17 18 19 1A to 21 22 23 24 25 26 27 28 to 2F 30 31 32 to 39 3A 3B 3C 3D 3E 3F 40 to 47 48 49 4A to 51 52 53 54 55 56 57 58 to 5F 60 61 62 to 69 6A Fixed data-1 (Initialized data) Fixed data-2 Fixed data-1 (Initialized data) Fixed data-2 Fixed data-2 Fixed data-1 (Initialized data) Fixed data-2 Fixed data-1 (Initialized data) Fixed data-2 Fixed data-1 (Initialized data) Fixed data-2 Fixed data-1 (Initialized data) Fixed data-2 Fixed data-1 (Initialized data) Fixed data-2 Fixed data-1 (Initialized data) Fixed data-2 Fixed data-1 (Initialized data)
Address 6B 6C 6D 6E 6F 70 to 77 78 79 7A to 81 82 83 84 85 86 87 88 to B7 B8 B9 BA BB BC BD BE BF C0 to DF E0 E1 E2 E3 E4 E5 E6 E7 E8 E9 EA EB EC ED EE EF F0 F1 F2 F3 F4 F5 F6
Initial value NTSC PAL
Remark
Fixed data-2
Fixed data-1 (Initialized data) Fixed data-2 Fixed data-1 (Initialized data)
Fixed data-2
Fixed data-1 (Initialized data)
Fixed data-2
Fixed data-1 (Initialized data)
Fixed data-2
Fixed data-1 (Initialized data) Fixed data-2 Fixed data-1 (Initialized data) Fixed data-2 Fixed data-1 (Initialized data) Fixed data-2
HDR-HC1/HC1E/HC1K/HC1EK_ADJ 6-20
66 Page table Address F7 F8 F9 FA FB FC FD FE FF Initial value NTSC PAL Fixed data-2 Fixed data-1 (Initialized data) Fixed data-2 Fixed data-1 (Initialized data Fixed data-2 Fixed data-1 (Initialized data) Fixed data-2 Fixed data-1 (Initialized data) Remark Fixed data-1 (Initialized data)
10. 69 Page table Note 1: If reading/writing data on pages 69 set data: 06 to page: 0, address: 10, and then select pages: 9. By this data setting, the pages 69 can be selected. After the data reading/writing finished, return the data on page: 0, address: 10 to "00" Note 2: Fixed data-1: Initialized data. (Refer to "1. Initializing the F, 63 to 6F Page Data") Fixed data-2: Modified data. (Refer to "2. Modification of F, 63 to 6F Page Data") Initial value Address Remark NTSC PAL 01, 02 03 04 to FF Fixed data-1 (Initialized data) Fixed data-2 Fixed data-1 (Initialized data)
8. 67 Page table Note 1: If reading/writing data on pages 67, set data: 06 to page: 0, address: 10, and then select pages: 7. By this data setting, the pages 67 can be selected. After the data reading/writing finished, return the data on page: 0, address: 10 to "00" Note 2: Fixed data-1: Initialized data. (Refer to "1. Initializing the F, 63 to 6F Page Data") Fixed data-2: Modified data. (Refer to "2. Modification of F, 63 to 6F Page Data") Initial value Address Remark NTSC PAL 00 to AF B0 B1 B2 B3 to C0 C1 C2 to C6 C7 C8 to FF Fixed data-1 (Initialized data) Fixed data-2 Fixed data-1 (Initialized data) Fixed data-2 Fixed data-1 (Initialized data) Fixed data-2 Fixed data-1 (Initialized data) Fixed data-2 Fixed data-1 (Initialized data)
11. 6A Page table Note 1: If reading/writing data on pages 6A, set data: 06 to page: 0, address: 10, and then select pages: A. By this data setting, the pages 6A can be selected. After the data reading/writing finished, return the data on page: 0, address: 10 to "00". Note 2: Fixed data-1: Initialized data. (Refer to "1. Initializing the F, 63 to 6F Page Data") Fixed data-2: Modified data. (Refer to "2. Modification of F, 63 to 6F Page Data") Initial value Address Remark NTSC PAL 00 to 07 08 09 0A 0B to 0E 0F 10 to 18 19 1A to 2F 30 31 32 to 35 36 37 38 to 42 43 44 to 8D 8E 8F to FF Fixed data-1 (Initialized data) Fixed data-2 Fixed data-1 (Initialized data) Fixed data-2 Fixed data-1 (Initialized data) Fixed data-2 Fixed data-1 (Initialized data) Fixed data-2 Fixed data-1 (Initialized data) Fixed data-2 Fixed data-1 (Initialized data) Fixed data-2 Fixed data-1 (Initialized data) Fixed data-2 Fixed data-1 (Initialized data)
9. 68 Page table Note 1: If reading/writing data on pages 68, set data: 06 to page: 0, address: 10, and then select pages: 8. By this data setting, the pages 68 can be selected. After the data reading/writing finished, return the data on page: 0, address: 10 to "00". Note 2: Fixed data-1: Initialized data. (Refer to "1. Initializing the F, 63 to 6F Page Data") Fixed data-2: Modified data. (Refer to "2. Modification of F, 63 to 6F Page Data") Initial value Address Remark NTSC PAL 00 to FF Fixed data-1 (Initialized data)
HDR-HC1/HC1E/HC1K/HC1EK_ADJ 6-21
12. 6B Page table Note 1: If reading/writing data on pages 6B, set data: 06 to page: 0, address: 10, and then select pages: B. By this data setting, the pages 6B can be selected. After the data reading/writing finished, return the data on page: 0, address: 10 to "00". Note 2: Fixed data-1: Initialized data. (Refer to "1. Initializing the F, 63 to 6F Page Data") Fixed data-2: Modified data. (Refer to "2. Modification of F, 63 to 6F Page Data") Initial value Address Remark NTSC PAL 00 to 13 14 15 16 17 18 to 38 39 3A 3B 3C 3D 3E 3F 40 to 50 51 52 to 59 5A 5B 5C to 84 85 86 to 9F A0 A1 to A4 A5 A6 to BA BB BC to C7 C8 C9 CA CB CC CD to FF 00 00 00 00 00 00 00 00 Fixed data-1 (Initialized data) Fixed data-2 Fixed data-1 (Initialized data) Fixed data-2 Fixed data-1 (Initialized data) Fixed data-2 Fixed data-1 (Initialized data) Fixed data-2 Fixed data-1 (Initialized data) Fixed data-2 Fixed data-1 (Initialized data) Fixed data-2 Fixed data-1 (Initialized data) Fixed data-2 Fixed data-1 (Initialized data) Fixed data-2 Fixed data-1 (Initialized data) Fixed data-2 Fixed data-1 (Initialized data) Fixed data-2 Fixed data-1 (Initialized data) Fixed data-2 Fixed data-1 (Initialized data) Fixed data-2 Fixed data-1 (Initialized data) Emergency memory address (Camera section) Fixed data-1 (Initialized data)
13. 6C Page table Note 1: If reading/writing data on pages 6C, set data: 06 to page: 0, address: 10, and then select pages: C. By this data setting, the pages 6C can be selected. After the data reading/writing finished, return the data on page: 0, address: 10 to "00". Note 2: Fixed data-1: Initialized data. (Refer to "1. Initializing the F, 63 to 6F Page Data") Fixed data-2: Modified data. (Refer to "2. Modification of F, 63 to 6F Page Data") Initial value Address Remark NTSC PAL 00 to 1B 1C 1D 1E 1F 20 21 22 23 to 3C 3D 3E 3F to 73 74 75 76 77 78 79 7A 7B 7C to AC AD AE AF B0 B1 B2 B3 B4 B5 B6 to BB BC BD BE BF to C4 C5 C6 C7 to FF Fixed data-1 (Initialized data) Fixed data-2 Fixed data-1 (Initialized data) Fixed data-2 Fixed data-1 (Initialized data) Fixed data-2 Fixed data-1 (Initialized data) Fixed data-2 Fixed data-1 (Initialized data) Fixed data-2 Fixed data-1 (Initialized data) Fixed data-2 Fixed data-1 (Initialized data) Fixed data-2 Fixed data-1 (Initialized data)
HDR-HC1/HC1E/HC1K/HC1EK_ADJ 6-22
14. 6D Page table Note 1: If reading/writing data on pages 6D, set data: 06 to page: 0, address: 10, and then select pages: D. By this data setting, the pages 6D can be selected. After the data reading/writing finished, return the data on page: 0, address: 10 to "00". Note 2: Fixed data-1: Initialized data. (Refer to "1. Initializing the F, 63 to 6F Page Data") Fixed data-2: Modified data. (Refer to "2. Modification of F, 63 to 6F Page Data") Initial value Address Remark NTSC PAL 00 to 36 37 38 to 3F 40 41 42 43 44 45 46 47 48 49 4A 4B, 4C 4D 4E 4F to 70 71 72 to 89 8A 8B to AE AF B0 to E2 E3 E4 to FF Fixed data-1 (Initialized data) Fixed data-2 Fixed data-1 (Initialized data) Fixed data-2 Fixed data-1 (Initialized data) Fixed data-2 Fixed data-1 (Initialized data) Fixed data-2 Fixed data-1 (Initialized data) Fixed data-2 Fixed data-1 (Initialized data) Fixed data-2 Fixed data-1 (Initialized data) Fixed data-2 Fixed data-1 (Initialized data) Fixed data-2 Fixed data-1 (Initialized data) Fixed data-2 Fixed data-1 (Initialized data) Fixed data-2 Fixed data-1 (Initialized data) Fixed data-2 Fixed data-1 (Initialized data)
HDR-HC1/HC1E/HC1K/HC1EK_ADJ 6-23
15. 6E Page table Note 1: If reading/writing data on pages 6E, set data: 06 to page: 0, address: 10, and then select pages: E. By this data setting, the pages 6E can be selected. After the data reading/writing finished, return the data on page: 0, address: 10 to "00". Note 2: Fixed data-1: Initialized data. (Refer to "1. Initializing the F, 63 to 6F Page Data") Fixed data-2: Modified data. (Refer to "2. Modification of F, 63 to 6F Page Data") Initial value Address Remark NTSC PAL 00 01 02 03 04 05 06 07 08 09 0A 0B 0C 0D 0E 0F 10 11 12 13 14 15 16 17 18 19 1A 1B 1C 1D 1E 1F 20 21 22 23 24 25 26 27 1C 30 05 90 1C 30 05 90 1C 30 05 90 1C 30 05 90 11 30 09 A0 11 30 09 A0 11 30 09 A0 11 30 09 A0 F4 F4 27 24 E8 E6 22 27 1C 30 05 90 1C 30 05 90 1C 30 05 90 1C 30 05 90 11 30 09 A0 11 30 09 A0 11 30 09 A0 11 30 09 A0 F4 F4 27 24 E8 E6 22 27 Color reproduction adj. AWB adj. AWB standard data input
Address 28 29 2A 2B 2C 2D 2E 2F 30 31 32 33 34 35 36 37 38 39 3A 3B 3C 3D 3E 3F 40 to 5F 60 61 62 63 64 65 66 67 68 69 6A 6B 6C 6D 6E 6F 70 71 72 73 74 75 76
Initial value NTSC PAL F4 F4 27 24 E8 E6 22 27 F4 F4 27 24 E8 E6 22 27 F4 F4 27 24 E8 E6 22 27 F4 F4 27 24 E8 E6 22 27 F4 F4 27 24 E8 E6 22 27 F4 F4 27 24 E8 E6 22 27
Remark
Color reproduction adj.
Fixed data-1 (Initialized data)
Fixed data-2
HDR-HC1/HC1E/HC1K/HC1EK_ADJ 6-24
6E Page table Initial value Address NTSC PAL 77 78 79 7A 7B 7C 7D 7E 7F 80 to FF
Remark
Fixed data-2
16. 6F Page table Note 1: If reading/writing data on pages 6F, set data: 06 to page: 0, address: 10, and then select pages: F. By this data setting, the pages 6F can be selected. After the data reading/writing finished, return the data on page: 0, address: 10 to "00". Note 2: Fixed data-1: Initialized data. (Refer to "1. Initializing the F, 63 to 6F Page Data") Fixed data-2: Modified data. (Refer to "2. Modification of F, 63 to 6F Page Data") Initial value Address Remark NTSC PAL 10 11 80 80 Fixed data-1 (Initialized data) Flange back and zoom key center adj. Fixed data-1 (Initialized data) 55 70 56 78 19 28 D8 28 D8 00 00 00 00 00 00 00 00 00 00 00 00 00 00 33 80 A0 20 00 00 00 00 00 00 00 20 55 70 56 78 19 28 D8 28 D8 00 00 00 00 00 00 00 00 00 00 00 00 00 00 33 80 A0 20 00 00 00 00 00 00 00 20 PCGM standard data input LV standard data input Max gain adj. Fixed data-1 (Initialized data) F No. and ND light quality standard data input HALL adj.
Fixed data-1 (Initialized data) 12 13 14 15 16 17 18 19 1A 1B 1C 1D 1E 1F 20 21 22 23 24 25 26 27 28 29 2A 2B 2C 2D 2E 2F 30 31 32 33 34 35 36
HDR-HC1/HC1E/HC1K/HC1EK_ADJ 6-25
Address 37 38 39 3A 3B 3C 3D 3E 3F 40 to 47 48 49 4A 4B 4C 4D 4E 4F 50 51 52 53 54 55 56 57 58 59 5A 5B 5C 5D 5E 5F 60 61 62 63 64 65 66 to 71 72 73 74, 75 76 77 78
Initial value NTSC PAL 00 00 00 00 00 00 00 20 00 11 80 53 EE 23 67 00 00 00 00 7F 19 00 32 00 06 00 00 00 00 00 00 00 00 20 00
Remark
6F Page table Initial value Address NTSC PAL 79 7A 7B 7C 7D 7E 7F 80 81 82 83 84 85 86 87 88 89 8A 8B 8C 8D 8E 8F 90 91 92 to B7 B8 B9 BA BB BC BD BE BF 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 38 00 30 00 28 00 40 50 50 50 30 1E 80 80 80 80 80 80 02 E0 80 80 80 20 00 30 00 28 00 20 00 40 50 50 50 30 1E 80 80 80 80 80 80 02 E0 80 80 80 20
Remark
PCGM standard data input
Fixed data-1 (Initialized data) 11 80 53 EE 23 67 00 00 00 00 7F 19 00 32 00 06 00 MR adj./Flange back and zoom lever center adj. Fixed data-1 (Initialized data) 80 80 80 80 40 C0 40 C0 40 C0 40 C0 80 80 80 80 40 C0 40 C0 40 C0 40 C0 Fixed data-1 (Initialized data) Fixed data-2 Fixed data-1 (Initialized data) 60 00 45 4D 00 38 Mechanical shutter adj. MR adj. Flange back and zoom lever center adj.
Mechanical shutter adj.
Strobe light level adj.
Fixed data-1 (Initialized data)
C0 C1 C2 C3 C4 C5 C6 C7 C8 C9 CA CB CC
Image sensor output 2ch matching adj.
HDR-HC1/HC1E/HC1K/HC1EK_ADJ 6-26
6F Page table Initial value Address NTSC PAL CD 00 00 CE CF D0 D1 D2 D3 D4 D5 D6 D7 D8 D9 DA DB DC DD DE DF E0 E1 E2 E3 E4 E5 E6 E7 E8 E9 EA EB EC ED EE EF F0 F1 F2 F3 F4 F5 F6 F7 F8 F9 2D 64 2D 64 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00
Remark
6F Page table Initial value Address NTSC PAL FA, FB FC FD FE FF 2C C0 59 00 2C C0 59 00 AWB adj.
Remark Fixed data-1 (Initialized data)
Image sensor output 2ch matching adj.
Fixed data-1 (Initialized data) Strobe white balance adj.
HDR-HC1/HC1E/HC1K/HC1EK_ADJ 6-27
1-3.
CAMERA SYSTEM ADJUSTMENTS
Before perform the camera system adjustments, check that the specified values of "VIDEO SYSTEM ADJUSTMENTS" are satisfied. (Except Origin Oscillation Check") Check that the data of page: 0, address: 10 is "00". If not, select page: 0, address: 10, and set the data "00". 1. Origin Oscillation Check (TT-001 board) Check the frequency of the clock for synchronization. If deviated, the synchronization will be disrupted and the color will become inconsistent. Subject Measurement Point Measuring Instrument Specified value Not required Pin 5 of IC1403 on TT-001 board Frequency counter f = 44505000 ± 895 Hz (NTSC) f = 37125000 ± 745 Hz (PAL)
Switch setting 1) POWER ............................................. CAMERA-TAPE mode Checking method: 1) Check that the frequency (f) satisfies the specified value.
TT-001 BOARD (SIDE A)
8
5
IC1403
1
4
Fig. 6-1-8
HDR-HC1/HC1E/HC1K/HC1EK_ADJ 6-28
2. HALL Adjustment RadarW For detecting the position of lens iris and ND filter, adjust the hall AMP gain and offset. Subject Measurement Point Measuring Instrument Adjustment Page Adjustment Address Specified value 1 Specified value 2 Specified value 3 Specified value 4 Not required Displayed data of page: 1 (Note 1) Adjusting remote commander 6F 13 to 1B D6 to DA 26 to 2A D6 to DA 26 to 2A
Adjusting method: Order Page Address Data 1 2 3 4 0 6 6 6 01 01 02 01 00 01 6D Press PAUSE button. (Note 3) Check the data changes to "01". Press PAUSE button. Procedure
Note 3: The adjustment data will be automatically input to page: 6F, address: 13 to 1B. Checking method: Order Page Address Data 1 2 3 4 5 6 7 8 9 10 11 0 6 6 1 6 1 6 6 1 6 1 01 6B 01 01 6B 69 01 01 03 01 01 03 01 03 Press PAUSE button. Press PAUSE button. Check that the IRIS displayed data (Note 1) satisfied the specified value 1. Press PAUSE button. Check that the IRIS displayed data (Note 1) satisfied the specified value 2. Press PAUSE button. Press PAUSE button. Check that the ND displayed data (Note 1) satisfied the specified value 3. Press PAUSE button. Check that the ND displayed data (Note 1) satisfied the specified value 4. Procedure
Note 1: The right four digits of the page: 1 displayed data of the adjusting remote commander. 1 : XX : XX IRIS displayed data ND displayed data Note 2: If reading/writing data on pages 6F, set data: 06 to page: 0, address: 10, and then select pages F. By this data setting, the pages 6F can be selected. After the data reading/writing finished, return the data on page: 0, address: 10 to "00". Switch setting 1) POWER ............................................. CAMERA-TAPE mode
Processing after Completing Adjustment: Order Page Address Data 1 2 3 6 0 0 01 03 01 00 00 00 Procedure Press PAUSE button.
HDR-HC1/HC1E/HC1K/HC1EK_ADJ 6-29
3. MR Adjustment RadarW The inner focus lens MR adjustment is carried out automatically. In whichever case, the focus will be deviated during auto focusing/manual focusing. Subject Measurement Point Measuring Instrument Adjustment Page Adjustment Address Specified value 1 Specified value 2 Specified value 3 6F 58, 5A to 65 40 to C0 03 to 78 88 to FD Not required Adjusting remote commander
Note 1: Perform the adjustment with the lens in horizontal state. Note 2: Perform "Flange Back Adjustment" after this adjustment. Note 3: If reading/writing data on pages 6F, set data: 06 to page: 0, address: 10, and then select pages F. By this data setting, the pages 6F can be selected. After the data reading/writing finished, return the data on page: 0, address: 10 to "00". Note 4: Check that the data of page: 6, address: 02 is "00". If not, select page: 6, address: 01, set data: 00, and press the PAUSE button.
Switch setting 1) POWER ............................................. CAMERA-TAPE mode Adjusting method: Order Page Address Data 1 2 3 4 5 0 6 6 0 F (6F) 01 01 02 10 5A 5B 5C 5D 5E 60 62 64 5F 61 63 65 10 00 06 Check that the data of each address satisfied the specified value 1. Check that the data of each address satisfied the specified value 2. Check that the data of each address satisfied the specified value 3. 01 BD Press PAUSE button. (Note 5) Check the data changes to "01". Procedure
6
F (6F)
7 8
F (6F) 0
Note 5: The adjustment data will be automatically input to page: 6F, address: 58, 5A to 65. Processing after Completing Adjustment: Order Page Address Data 1 2 3 4 6 6 6 0 01 01 01 01 00 25 00 00 Procedure Press PAUSE button. Press PAUSE button. Press PAUSE button.
HDR-HC1/HC1E/HC1K/HC1EK_ADJ 6-30
4.
Image Sensor Output 2ch Matching Adjustment
RadarW
Correct the dispersion of between the left-right channels of CMOS imager. Subject Adjustment Page Adjustment Address Clear chart (All white) (Note 1) 6F B8 to F6
Note 1: Shoot the clear chart with the zoom TELE end. Note 2: If reading/writing data on pages 6F, set data: 06 to page: 0, address: 10, and then select pages: 6. By this data setting, the pages 6F can be selected. After the data reading/writing finished, return the data on page: 0, address: 10 to "00". Note 3: Check that the data of page: 6, address: 02 is "00". If not, select page: 6, address: 01, set data: 00, and press PAUSE button. Switch setting 1) POWER ............................................. CAMERA-TAPE mode 2) NIGHT SHOT .................................................................. OFF 3) ZOOM ..................................................................... TELE end 4) STEADY SHOT (Menu setting) ..................................... OFF 5) FOCUS (Menu setting) .......................................... MANUAL Adjusting method: Order Page Address Data 1 2 3 4 5 6 7 0 6 6 6 6 6 6 01 2C 40 D0 D6 01 02 01 01 01 60 02 F5 Press PAUSE button. (Note 4) Check the data changes to "01". Procedure
Note 4: The adjustment data will be automatically input to page: 6F, address: B8 to F6. Processing after Completing Adjustment: Order Page Address Data 1 2 3 4 5 6 6 6 6 6 6 0 01 2C 40 D0 D6 01 00 00 00 00 00 00 Procedure Press PAUSE button.
HDR-HC1/HC1E/HC1K/HC1EK_ADJ 6-31
5.
Flange Back and Zoom Lever Center Adjustment
RadarW (Using the minipattern box or flange back adjustment jig) The inner focus lens flange back adjustment is carried out automatically. In whichever case, the focus will be deviated during auto focusing/manual focusing.
Subject Siemens star chart with ND filter for minipattern box (Note 1) or flange back adjustment jig Adjusting remote commander 6F 11, 48 to 58 Data of page: 6F, address: 57 is "00" to "09" Data of pege: 6, address: 0C is "00"
Measurement Point Measuring Instrument Adjustment Page Adjustment Address Specified value
Preparation (Using the minipattern box) 1) The minipattern box is installed as shown in the following figure. Note 7: The attachment lenses are not used. 2) Install the minipattern box so that the distance between it and the front of lens of camera is less than 3 cm. 3) Make the height of minipattern box and the camera equal. 4) Check the output voltage of the regulated power supply is the specified voltage ± 0.01 Vdc. 5) Check that the center of Siemens star chart meets the center of shot image screen with the zoom lens at TELE end and WIDE end respectively. Specified voltage: The specified voltage varies according to the minipattern box, so adjustment the power supply output voltage to the specified voltage written on the sheet which is supplied with the minipattern box.
Below 3 cm Minipattern box Camera
Note 1: Dark Siemens star chart. Note 2: Perform "HALL Adjustment", "MR Adjustment" and "Image Sensor Output 2ch Matching Adjustment" before this adjustment. Note 3: Perform the adjustment with the lens in horizontal state. Note 4: If reading/writing data on pages 6F, set data: 06 to page: 0, address: 10, and then select pages F. By this data setting, the pages 6F can be selected. After the data reading/writing finished, return the data on page: 0, address: 10 to "00". Note 5: Check that the data of page: 6, address: 02 is "00". If not, select page: 6, address: 01, set data: 00, and press PAUSE button. Note 6: Don't touch the zoom lever during adjustment. Switch setting 1) POWER ............................................. CAMERA-TAPE mode 2) NIGHT SHOT .................................................................. OFF 3) COLOR SLOW S (Menu setting) ................................... OFF 4) REC FORMAT (Menu setting) ............................. HDV1080i
Regulated power supply Output voltage : Specified voltage ± 0.01 Vdc Output current : more than 3.5 A
Red (+) Black () Yellow (SENS +) White (SENS ) Black (GND) Need not connected
Fig. 6-1-9
Preparation (Using the flange back adjustment jig) (Luminance: 300 to 400 lux) 1) Install the flange back adjustment jig so that the distance between it and the front of lens of camera is less than 3 cm. 2) Make the height of flange back adjustment jig and the camera equal. 3) Check that the center of chart meets the center of shot image screen with the zoom lens at TELE end and WIDE end respectively.
Below 3 cm
Flange back adjustment jig
Camera
Fig. 6-1-10
HDR-HC1/HC1E/HC1K/HC1EK_ADJ 6-32
Adjusting method: Order Page Address Data 1 2 3 4 5 6 7 8 9 10 11 12 13 14 6 6 6 0 F (6F) 0 01 02 0C 10 57 10 00 06 Check the data is "00" to "09". 27 0 6 6 0 B (6B) 0 6 01 4D 64 10 0D 10 01 00 13 Press PAUSE button. Wait for 2 seconds. Press PAUSE button. (Note 9) Check the data changes to "01". Check the data is "00". 01 40 04 06 Set the bit value of bit3 is "1", and press PAUSE button. (Note 8) Procedure
Note 8: For the bit values, refer to "6-4. SERVICE MODE", "43. 3. Bit value discrimination". Note 9: The adjustment data will be automatically input to page: 6F, address: 11, 48 to 58. Processing after Completing Adjustment: Order Page Address Data 1 2 3 4 5 6 7 8 9 10 6 6 6 6 6 0 B (6B) 0 0 01 01 01 4D 64 10 0D 10 01 00 00 Perform "Flange Back Check". 00 25 00 00 00 06 Set the bit value of bit3 is "0", and press PAUSE button. (Note 8) Procedure Press PAUSE button. Press PAUSE button. Press PAUSE button.
HDR-HC1/HC1E/HC1K/HC1EK_ADJ 6-33
6.
Flange Back and Zoom Lever Center Adjustment (Using the flange back adjustment chart and subject more than 500 m away) The inner focus lens flange back adjustment is carried out automatically. In whichever case, the focus will be deviated during auto focusing/manual focusing. 6-1. Subject Flange Back Adjustment (1) RadarW Flange back adjustment chart (2.0 m from the front of lens) (Luminance: 300 to 400 lux) Adjusting remote commander 6F 11, 48 to 58 Data of page: 6F, address: 57 is "00" to "09" Data of pege: 6, address: 0C is "00"
Adjusting method: Order Page Address Data 1 2 3 4 5 6 7 8 9 10 11 12 13 14 6 6 6 0 F (6F) 0 01 02 0C 10 57 10 00 06 Check the data is "00" to "09". 15 0 6 6 0 B (6B) 0 6 01 4D 64 10 0D 10 01 00 13 Press PAUSE button. Wait for 2 seconds. Press PAUSE button. (Note 7) Check the data changes to "01". Check the data is "00". 01 40 04 06 Set the bit value of bit3 is "1", and press PAUSE button. (Note 6) Procedure
Measurement Point Measuring Instrument Adjustment Page Adjustment Address Specified value
Note 1: Perform "HALL Adjustment", "MR Adjustment" and "Image Sensor Output 2ch Matching Adjustment" before this adjustment. Note 2: Perform the adjustment with the lens in horizontal state. Note 3: If reading/writing data on pages 6F, set data: 06 to page: 0, address: 10, and then select pages F. By this data setting, the pages 6F can be selected. After the data reading/writing finished, return the data on page: 0, address: 10 to "00". Note 4: Check that the data of page: 6, address: 02 is "00". If not, select page: 6, address: 01, set data: 00, and press PAUSE button. Note 5: Don't touch the zoom lever during adjustment. Switch setting 1) POWER ............................................. CAMERA-TAPE mode 2) NIGHT SHOT ......