Text preview for : SONY HDR-FX1000, FX1000E SECTION 6 ADJUSTMENTS ADJ VER 1.1 2008.11 (9-852-622-52).pdf part of SONY HDR-FX1000 SONY HDR-FX1000, FX1000E DIGITAL HD VIDEO CAMERA RECORDER. SECTION 6 ADJUSTMENTS VERSION 1.1 2008.11 PART#(9-852-622-52)



Back to : SONY HDR-FX1000, FX1000E | Home

HDR-FX1000/FX1000E
RMT-831
Ver. 1.1 2008.11
Revision History

SECTION 6 ADJUSTMENTS

ADJ

Link
Before starting adjustments
Adjusting items when replacing main parts and boards List of service tools

VIDEO SECTION ADJUSTMENTS
PREPARATIONS BEFORE ADJUSTMENTS SYSTEM CONTROL SYSTEM ADJUSTMENTS SERVO AND RF SYSTEM ADJUSTMENTS

CAMERA SECTION ADJUSTMENTS
VIDEO SYSTEM ADJUSTMENTS
PREPARATIONS BEFORE ADJUSTMENTS

AUDIO SYSTEM ADJUSTMENTS
INITIALIZATION OF EVR DATA CAMERA SYSTEM ADJUSTMENTS ELECTRONIC VIEWFINDER SYSTEM ADJUSTMENTS LCD SYSTEM ADJUSTMENTS

SERVICE MODE
ADJUSTMENT REMOTE COMMANDER (RM-95) ADJUSTMENT REMOTE COMMANDER (NEW LANC JIG) DATA PROCESS

MECHANISM SECTION ADJUSTMENTS
HOW TO ENTER RECORD MODE WITHOUT CASSETTE HOW TO ENTER PLAYBACK MODE WITHOUT CASSETTE TAPE PATH ADJUSTMENT

SERVICE MODE

NTSC MODEL: HDR-FX1000 PAL MODEL: HDR-FX1000E

HDR-FX1000/FX1000E_ADJ
9-852-622-52

Sony EMCS Co.

2008K0800-1 © 2008.11 Published by Kohda TEC

SECTION 6 ADJUSTMENTS

1.

Before starting adjustments EVR Data Re-writing Procedure When Replacing Board
The data that is stored in the repair board, is not necessarily correct. Perform either procedure 1 or procedure 2 or procedure 3 when replacing board.

Procedure 1
Save the EVR data of the machine in which a board is going to be replaced. Download the saved data after a board is replaced.
(Machine before starting repair) PC PC (Machine after a board is replaced)

Save the EVR data to a personal computer.

Download the saved data to a machine.

Procedure 2
Remove the EEPROM from the board of the machine that is going to be repaired. Install the removed EEPROM to the replaced board.
Remove the EEPROM and install it.

(Former board)

(New board)

Procedure 3
When the data cannot be saved due to defective EEPROM, or when the EEPROM cannot be removed or installed, save the data from the same model of the same destination, and download it.
(Machine to be repaired) PC (Machine to be repaired)

Download the data. Save the data.

(The same model of the same destination)

After the EVR data is saved and downloaded, check the respective items of the EVR data. (Refer to page 6-3 for the items to be checked)

HDR-FX1000/FX1000E_ADJ 6-1

Ver. 1.1 2008.11
The changed portions from Ver. 1.0 are shown in blue.

1-1. Adjusting items when replacing main parts and boards · Adjusting items when replacing main parts When replacing main parts, adjust the items indicated by z in the following table. Note 1: When replacing the drum assy or the mechanism deck, reset the data of page: 7, address: A8 to AB to "00". (Refer to "Record of Use check" of "6-4. SERVICE MODE") Note 2: If the lens is broken, it must be replace with the already adjusted lens.
Replaced part Block replacement
PRISM device (Inclding CM-097 and CM-104 board and CMOS imager (IC3001/IC5001))

Mounted part replacement
(PITCH, YAW sensor) (Oscillator) (Camera signal processor) (Base band signal processor, etc.) (DV signal processor, etc.) (Video out AMP) (Component out AMP) (REC/PB AMP) (EVF drive, etc.) (LCD drive, etc.)
z z z z z z z z z z z z z z z z z z z z z z z z z z z z z

(3.2 inch wide color LCD unit) (Backlight) (Color EVF unit)
z z z

Adjustment Section

Adjustment

Initialization of EVR data

Camera

EVF LCD

Mechanism System control Servo, RF

Video

Initialization of A, B, D, 1A, 1B page data Initialization of 8, 9, C, 13, 18, 1C, 1D, 1E page data Initialization of camera control page data Origin oscillation check PSD sensor adj. Lens adj. MR sensor (Focus/Zoom Ring) adj. Coaxial harness connecting check Flange back adj. Black balance adj. Auto white balance standard data input LV standard data input STD GAIN adj. MAX GAIN adj. Auto white balance adj. Color reproduction adj. White defect adj. Black defect adj. Angular velocity sensor sensitivity adj. EVF gain adj. PANEL gain adj. V-COM adj. Transmissive mode white balance adj. Tape path adj. Node unique ID No. input CAP FG duty adj. Switching position adj. SD Error rate check S VIDEO OUT Y level adj. S VIDEO OUT chroma level adj. VIDEO OUT level check COMPONENT OUT Y level adj. COMPONENT OUT Pr level adj. COMPONENT OUT Pb level adj.

z z z z z z z z z z z z z

z z z z z z z z z z z z

Table 6-1-1 (1)

HDR-FX1000/FX1000E_ADJ 6-2

LCD block LCD901 LCD block D901 EVF block LCD902 Mechanism deck (Note 1) Mechanism deck M901 Mechanism deck MD block GY-014 board SE8501, 8502 VC-543 board X1401 VC-543 board IC1401 VC-543 board IC1801 VC-543 board IC2601 VC-543 board IC2002 VC-543 board IC2001 MD-141 board IC5201 VF-178 board IC6201 PD-372 board IC6001
z z z z z z z z z z z

Lens Block (Note 2)

(Drum assembly) (Note 1)

Ver. 1.1 2008.11
The changed portions from Ver. 1.0 are shown in blue. · Adjusting items when replacing a board or EEPROM When replacing a board or EEPROM, adjust the items indicated by z in the following table.
Replaced part

Note 3: IC2402, IC3804 (Flash memories) on the VC-543 board cannot be replaced.

(COMPLETE) (COMPLETE) (COMPLETE) (COMPLETE) (COMPLETE)

Adjustment Section

Adjustment

VC-543 board IC3805
z

(EEPROM) Supporting RadarW
z z z z z z z z z z z z z z z z z

Initialization of EVR data

Camera

EVF LCD

Mechanism System control Servo, RF

Video

Initialization of A, B, D, 1A, 1B page data Initialization of 8, 9, C, 13, 18, 1C, 1D, 1E page data Initialization of camera control page data Origin oscillation check PSD sensor adj. Lens adj. MR sensor (Focus/Zoom Ring) adj. Coaxial harness connecting check Flange back adj. Black balance adj. Auto white balance standard data input LV standard data input STD GAIN adj. MAX GAIN adj. Auto white balance adj. Color reproduction adj. White defect adj. Black defect adj. Angular velocity sensor sensitivity adj. EVF gain adj. PANEL gain adj. V-COM adj. Transmissive mode white balance adj. Tape path adj. Node unique ID No. input CAP FG duty adj. Switching position adj. SD Error rate check S VIDEO OUT Y level adj. S VIDEO OUT chroma level adj. VIDEO OUT level check COMPONENT OUT Y level adj. COMPONENT OUT Pr level adj. COMPONENT OUT Pb level adj.

Table 6-1-1 (2)

HDR-FX1000/FX1000E_ADJ 6-3

GY-014 board VC-543 board MD-141 board VF-178 board PD-372 board
z z z z z z z z z z z z z z z z z z z z z z z z z z z z z z z z z z z z z z z z

1-2. List of service tools · Oscilloscope · Color monitor · Digital voltmeter · Frequency counter · Balanced audio generator · Calculating machine capable of calculating hexadecimal numbers
J-1 Adjustment remote commander (RM-95) J-6082-053-B J-2

· Regulated power supply · Audio level meter

J-3 Adjustment remote commander (NEW LANC JIG) J-6082-565-A LANC cable J-6082-442-A

J-4 Small pattern box PTB-1450 J-6082-557-A

J-5 Color bar chart For PTB-1450: J-6082-559-A

J-6 Clear chart For PTB-1450: J-6082-560-A

J-7 Flange back adjustment jig J-6082-563-A

J-8

J-9 Filter for color temperature correction (C14) J-6080-058-A

Siemens star chart J-6080-875-A

J-10 ND filter 1.0 J-6080-808-A ND filter 0.4 J-6080-806-A ND filter 0.1 J-6080-807-A J-13 SW/OL standard (XH2-3) 8-967-997-11

J-11

J-12 Tracking standard (XH2-1) 8-967-997-01

Camera table J-6082-384-A

J-14

Audio operation check for NTSC (XH5-3) 8-967-997-51 for PAL (XH5-3P) 8-967-997-55

J-15

System operation check for NTSC (XH5-5) 8-967-997-61 for PAL (XH5-5P) 8-967-997-66

J-16 CPC-13 jig J-6082-443-A

J-17 AC Adaptor (AC-L100) 1-479-286-32

J-18 Head cleaning liguid 9-919-573-01

Fig. 6-1-1 (1)

HDR-FX1000/FX1000E_ADJ 6-4

Ver. 1.1 2008.11
The changed portions from Ver. 1.0 are shown in blue.

J-19 Wiping cloth 7-741-900-53

J-20 Super fine applicator (made by Nippon Applicator (P752D))

J-21 Mirror (Small oval type) J-6080-840-A

J-22 Screwdraiver for the tape path J-6082-026-A

J-23 Mini DV torque cassette J-6082-360-A

J-24 Mode Selector II J-6082-282-B

J-25 Suncall Grease (FG-87HSR) 7-640-006-08

J-26
FWD/BACK T adjustment screwdriver J-6082-364-A

J-27
Torque screwdriver J-9049-330-A

J-28
Mode Selector II conversion board (N) J-6082-567-A

J-29
Mode Selector II ROM (Note1) J-6082-314-G

J-30

Torque Driver Bit (#0) J-6082-661-A J-33

J-31

J-32

Component A/V Cable 1-834-646-11

A/V Connecting Cable (1.5 m) (with S Video terminal) 1-823-156-13 J-35

A/V Connecting Cable 1-823-156-61

J-34

D Terminal A/V Cable 1-834-646-21

HDMI Cable (Optional)

Fig. 6-1-1 (2)
Note 1: This is the ROM used for upgrading the version of Mode Selector II to enable it to be used for the N mechanism. Set the indication to "Z" when using the mode selector II.

HDR-FX1000/FX1000E_ADJ 6-5

Ver. 1.1 2008.11
The changed portions from Ver. 1.0 are shown in blue.

6-1. CAMERA SECTION ADJUSTMENTS
1-1.
1-1-1.

PREPARATIONS BEFORE ADJUSTMENTS (CAMERA SECTION)
Preparations

Note: Before perform the adjustment, check that the data of page: 0, address: 10 is "00". If not, select page: 0, address: 10, and set data "00". 1) Connect the equipment for adjustments according to Fig. 6-1-2.

Adjustment remote commander NEW LANC JIG (J-6082-565-A) LANC cable (J-6082-442-A) RM-95 (J-6082-053-B)

LANC jack

Except J Model
HDTV Color monitor
To AC adaptor (AC-L100)

Component A/V cable (1-834-646-11) (Supplied) or HDMI cable (Optional)

(Green) Y (Blue) PB/CB (Red) PR/CR (White) Audio L (Red) Audio R

COMPONENT VIDEO IN

HDMI OUT

A/V R

HDMI IN

J Model
HDTV Color monitor Y PB/CB PR/CR (White) Audio L (Red) Audio R HDMI IN COMPONENT VIDEO IN (D3/D4/D5)
A/V R

Connection cord (AV Multiple) (1-834-646-21) (Supplied) or HDMI cable (Optional)

HDMI OUT

Fig. 6-1-2

HDR-FX1000/FX1000E_ADJ 6-6

1-1-3. Precaution 1. Setting the Switch Unless otherwise specified, set the switches as follows and perform adjustments without loading cassette. 1. 2. 3. 4. 5. CAMERA/VCR switch ......................................... CAMERA FOCUS switch ............................................................. AUTO ND FILTER .................................................................... OFF SHUTTER SPEED ..................................................... AUTO MENU settings CAMERA SET menu BACK LIGHT ........................................................ OFF SPOT LIGHT .......................................................... OFF D. EXTENDER ...................................................... OFF IN/OUT REC menu REC FORMAT ............................................. HDV1080i

2. Order of Adjustments Basically carry out adjustments in the order given. Color bar chart (Color reproduction adjustment frame)
Yellow Cyan Green White Magenta Red
H Electronic beam scanning frame C C=D=0 D

Blue

Magenta

Yellow

Green

White

Cyan

Blue

Red

CRT picture frame

A B

A=B

B A Enlargement

V

Fig. b (monitor TV picture)

Fig. a (VIDEO OUT jack output waveform)
Difference in level

B

A

Adjust the camera zoom and direction to obtain the output waveform shown in Fig. a and the monitor TV display shown in Fig. b.

Fig. 6-1-3
3. Subjects 1) Color bar chart (Color reproduction adjustment frame) When performing adjustments using the color bar chart, adjust the picture frame as shown in Fig. 6-1-3. (Color reproduction adjustment frame) 2) Clear chart (Color reproduction adjustment frame) Remove the color bar chart from the pattern box and insert a clear chart in its place. (Do not perform zoom operations during this time)

HDR-FX1000/FX1000E_ADJ 6-7

4. Setting Distance between Pattern Box and Camera Set the distance from the front of the lens to the pattern box as shown in Fig. 6-1-4.
L = 17 cm (PTB-1450) Pattern box L Front of the lens Camera

Fig. 6-1-4
5. Precautions When Using Pattern Box 1) It takes about 30 minutes for pattern box to stabilize its brightness. Turn on the pattern box 30 minutes before the adjustment starts. 2) Make arrangement so that the outside light does not enter the chart surface in the pattern box. Also, place a board between chart and camera, and make a hole at the lens part of the board so that the camera is not reflected in the shot image screen. (Adjustment may not be performed correctly due to the influence of outside light.) Example 1: Place a box to block a section between pattern box and camera.
Make the hole of the same size as the pattern box. Make the hole of the same size as the lens.

L = 17 cm (PTB-1450) Pattern box L Front of the lens Camera

Example 2: Place a board having a hole in front of the camera and cover the pattern box and camera with a blackout curtain

Cover with a blackout curtain L = 17 cm (PTB-1450) Pattern box L

Board that opens hole to lens part

Front of the lens Camera

3) Control of color chart The color chart will fade if it is exposed to direct sunlight or strong light. Since the fading of color chart progresses even with the light in the pattern box, remove and store the color chart when it is not used. Remove the color chart and store it. Store the color chart in a place not exposed to direct light, avoiding high temperature and humidity. Use the color chart for about three years, and afterward replace it with a new chart.

HDR-FX1000/FX1000E_ADJ 6-8

1-2.

INITIALIZATION OF EVR DATA

Note 1: Pages used for the EVR consists of 45 pages. There are 7C, 7E, 7F, 8, 9, A, B, C, D, 13, 18, 1A, 1B, 1C, 1D, 1E, 6D, 6E, 6F, 8C, 8D, 8E, 8F, 9D, 9E, 9F, AD, AE, AF, BE, BF, C2, C3, C4, C5, C6, C7, C8, C9, CA, CB, CC, CD, CE, CF, pages. Note 2: If 2-digit page is selected, set higher-order digit to page: 0, address: 10 as data, and then select lower-order digit by a usual method. e.g.: Set data: 06 to page: 0, address: 10, and then select page: D. Thus, the page 6D can be selected. 1-2-1. Initialization of A, B, D, 1A, 1B Page Data Note: Check that the data of page: 0, address: 10 is "00". 1. Initializing of A, B, D, 1A, 1B Page Data Note: If the A, B, D, 1A, 1B page data has been initialized, the following adjustments need to be performed again. 1) Modification of A, B, D, 1A, 1B page data 2) Level vial adjustment Adjustment Page Adjustment Address Adjustment Page Adjustment Address Adjustment Page Adjustment Address Adjustment Page Adjustment Address Adjustment Page Adjustment Address Initializing method: Order Page Address Data 1 2 3 0 0 2 01 10 EA 01 00 Check the bit1 value. 1: NTSC model 0: PAL model Set the following data 00: NTSC model 01: PAL model Set the following data 20: Initializing A page 21: Initializing B page 22: Initializing D page 23: Initializing 1A page 24: Initializing 1B page 25: Initializing A and 1A page 26: Initializing B and 1B page 28: Initializing A, B, D, 1A and 1B page FF 01 Press PAUSE (Write) button. Check the data changes to "01". Perform "Modification of A, B, D, 1A, 1B Page Data" Procedure A 10 to FF B 00 to FF D 10 to FF 1A 00 to FF 1B 00 to FF

2. Modification of A, B, D, 1A, 1B Page Data If the A, B, D, 1A, 1B page data has been initialized, change the data of the "Fixed data-2" address shown in the following table by manual input. Modifying Method: 1) Before changing the data, select page: 0, address: 01, and set data: 01. 2) If modification of data on pages A, B, D, set data: 00 to page: 0, address: 10, and then select pages A, B, D. 3) If modification of data on pages 1A, 1B, set data: 01 to page: 0, address: 10, and then select pages A, B. After the modification of data finished, return the data on page: 0, address: 10 to "00". 4) New data for changing are not shown in the tables because they are different in destination. When changing the data, copy the data built in the same model. Note 1: If copy the data built in the different model, the camcorder may not operate. 5) When changing the data, press the PAUSE (Write) button of the adjustment remote commander each time when setting new data to write the data in the non-volatile memory. 6) Check that the data of adjustment addresses is the initial value. If not, change the data to the initial value. Processing after Completing Modification A, B, D, 1A, 1B page data: Order Page Address Data 1 2 3 0 2 2 10 00 01 00 29 29 Press PAUSE (Write) button. Procedure

Note 2: If following symptoms occur after completing of the "Modification A, B, D, 1A, 1B page data", check that the data of the "Fixed data-2" address of A, B, D, 1A, 1B page are same as those of same model of same destination. 1) The power is shut off so that unit cannot operate.

4

7

04

5

7

01

6 7 8 9

7 7 7

02 00 02

HDR-FX1000/FX1000E_ADJ 6-9

Ver. 1.1 2008.11
The changed portions from Ver. 1.0 are shown in blue.

3. A Page table Note 1: Check that the data of page: 0, address: 10 is"00". Note 2: Fixed data-1: Initialized data. (Refer to"1. Initializing the A, B, D, 1A, 1B Page Data") Fixed data-2: Modified data. (Refer to"2. Modification of A, B, D, 1A, 1B Page Data") Initial value Address Remark NTSC PAL 10 11 to 17 18 19 to 2E 2F 30 31 32 to EF F0 to F3 F4, F5 F6 F7 F8 F9 FA FB FC to FF 27 DE 28 18 28 22 27 DE 28 18 28 22 Fixed data-1 (Initialized data) Level vial adj. 00 00 Test mode Fixed data-1 (Initialized data) Fixed data-2 Fixed data-1 (Initialized data) Fixed data-2 Fixed data-1 (Initialized data) Fixed data-2 Fixed data-1 (Initialized data) Fixed data-2 Fixed data-1 (Initialized data)

5. D Page table Note 1: Check that the data of page: 0, address: 10 is "00". Note 2: Fixed data-1: Initialized data. (Refer to "1. Initializing the A, B, D, 1A, 1B Page Data") Fixed data-2: Modified data. (Refer to "2. Modification of A, B, D, 1A, 1B Page Data") Initial value Address Remark NTSC PAL 10 to FF Fixed data-1 (Initialized data)

6. 1A Page table Note 1: If reading/writing data on pages 1A, set data: 01 to page: 0, address: 10, and then select pages: A. By this data setting, the pages 1A can be selected. After the data reading/writing finished, return the data on page: 0, address: 10 to "00". Note 2: Fixed data-1: Initialized data. (Refer to "1. Initializing the A, B, D, 1A, 1B Page Data") Fixed data-2: Modified data. (Refer to "2. Modification of A, B, D, 1A, 1B Page Data") Initial value Address Remark NTSC PAL 00 to FF Fixed data-1 (Initialized data)

4. B Page table Note 1: Check that the data of page: 0, address: 10 is "00". Note 2: Fixed data-1: Initialized data. (Refer to "1. Initializing the A, B, D, 1A, 1B Page Data") Initial value Address Remark NTSC PAL 00 to B0 B1 B2 to FF Fixed data-1 (Initialized data) Fixed data-2 Fixed data-1 (Initialized data)

7. 1B Page table Note 1: If reading/writing data on pages 1B, set data: 01 to page: 0, address: 10, and then select pages: B. By this data setting, the pages 1B can be selected. After the data reading/writing finished, return the data on page: 0, address: 10 to "00". Note 2: Fixed data-1: Initialized data. (Refer to "1. Initializing the A, B, D, 1A, 1B Page Data") Fixed data-2: Modified data. (Refer to "2. Modification of A, B, D, 1A, 1B Page Data") Initial value Address Remark NTSC PAL 00 to FF Fixed data-1 (Initialized data)

HDR-FX1000/FX1000E_ADJ 6-10

1-2-2.

Initialization of 8, 9, C, 13, 18, 1C, 1D, 1E Page Data

Order Page Address Data 8 3 90

Procedure Check the data changes to "1C". Perform "Modification of 8, 9, C, 13, 18, 1C, 1D, 1E Page Data"

1. Initializing of 8, 9, C, 13, 18, 1C, 1D, 1E Page Data Note 1: If "Initialization of Pages 8, 9, C, 13, 18, 1C, 1D, 1E" is executed, all data on pages 8, 9, C, 13, 18, 1C, 1D, 1E are initialized. (Only an individual page cannot be initialized) Note 2: If the 8, 9, C, 13, 18, 1C, 1D, 1E page data has been initialized, the following adjustments need to be performed again. 1) Modification of 8, 9, C, 13, 18, 1C, 1D, 1E page data 2) Electronic viewfinder system adjustments (if all areas were initialized) 3) LCD system adjustments (if all areas were initialized) 4) Node unique ID No. input (if all areas were initialized) 5) Servo, RF system adjustments (if all areas were initialized) 6) Video system adjustments (if all areas were initialized) Adjustment Page Adjustment Address Adjustment Page Adjustment Address Adjustment Page Adjustment Address Adjustment Page Adjustment Address Adjustment Page Adjustment Address Adjustment Page Adjustment Address Adjustment Page Adjustment Address Adjustment Page Adjustment Address Initializing method: Order Page Address Data 1 2 0 0 01 10 01 00 Set the following data, and press PAUSE (Write) button. (Note 3) 00: Initializing all areas 01: Initializing other than adjustment address 0C Press PAUSE (Write) button. Check the data changes to "1C". Set the following data, and press PAUSE (Write) button. (Note 3) 0A:Initializing all areas 1A:Initializing other than adjustment address 0C Press PAUSE (Write) button. Procedure 8 00 to FF 9 00 to FF C 10 to FF 13 00 to FF 18 00 to FF 1C 00 to FF 1D 00 to FF 1E 00 to FF

9

Note 3: If other than adjustment address was initialized, the adjusted data is not initialized. 2. Modification of 8, 9, C, 13, 18, 1C, 1D, 1E Page Data If the 8, 9, C, 13, 18, 1C, 1D, 1E page data has been initialized, change the data of the "Fixed data-2" address shown in the following table by manual input. Processing before Modification 8, 9, C, 13, 18, 1C, 1D, 1E page data: Order Page Address Data 1 2 3 0 0 3 01 10 71 01 00 01 Press PAUSE (Write) button. Procedure

Modifying Method: 1) If modification of data on pages 8, 9, C, set data: 00 to page: 0, address: 10, and then select pages 8, 9, C. 2) If modification of data on pages 13, 18, 1C, 1D, 1E, set data: 01 to page: 0, address: 10, and then select pages 3, 8, C, D, E. After the modification of data finished, return the data on page: 0, address: 10 to "00". 3) New data for changing are not shown in the tables because they are different in destination. When changing the data, copy the data built in the same model. Note: If copy the data built in the different model, the camcorder may not operate. 4) When changing the data, press the PAUSE (Write) button of the adjustment remote commander each time when setting new data to write the data in the non-volatile memory. 5) If all areas were initialized, check that the data at the addresses for adjustment are initial values (adjustment initial values) listed in the table. If different, change them to the adjustment initial values. Processing after Completing Modification 8, 9, C, 13, 18, 1C, 1D, 1E page data: Order Page Address Data 1 2 3 4 5 6 0 0 3 3 2 2 01 10 70 70 00 01 29 29 Press PAUSE (Write) button. 01 00 10 Press PAUSE (Write) button. Check the data changes to "11". Procedure

3

3

81

4 5

3 3

80 80

6

3

91

7

3

90

HDR-FX1000/FX1000E_ADJ 6-11

Ver. 1.1 2008.11
The changed portions from Ver. 1.0 are shown in blue.

3. 8 Page table Note 1: Check that the data of page: 0, address: 10 is"00". Note 2: Fixed data-1: Initialized data. (Refer to "1. Initializing the 8, 9, C, 13, 18, 1C, 1D, 1E Page Data") Fixed data-2: Modified data. (Refer to "2. Modification of 8, 9, C, 13, 18, 1C, 1D, 1E Page Data") Address 00 to F1 F2 F3 to FF Initial value NTSC PAL Fixed data-2 Fixed data-1 (Initialized data) Remark Fixed data-1 (Initialized data)

4. 9 Page table Note 1: Check that the data of page: 0, address: 10 is "00". Note 2: Fixed data-1: Initialized data. (Refer to "1. Initializing the 8, 9, C, 13, 18, 1C, 1D, 1E Page Data") Fixed data-2: Modified data. (Refer to "2. Modification of 8, 9, C, 13, 18, 1C, 1D, 1E Page Data") Address 00 to FF Initial value NTSC PAL Remark Fixed data-1 (Initialized data)

HDR-FX1000/FX1000E_ADJ 6-12

Ver. 1.1 2008.11
The changed portions from Ver. 1.0 are shown in blue.

5. C Page table Note 1: Check that the data of page: 0, address: 10 is "00". Note 2: Fixed data-1: Initialized data. (Refer to "1. Initializing the 8, 9, C, 13, 18, 1C, 1D, 1E Page Data") Fixed data-2: Modified data. (Refer to "2. Modification of 8, 9, C, 13, 18, 1C, 1D, 1E Page Data") Initial value Address Remark NTSC PAL 10 11 12 13 14, 15 16 17 to 24 25 26 27 28 to 7D 7E 7F 80 81to 8B 8C 8D 8E 8F to A0 A1 A2 A3 A4, A5 A6 A7 A8 A9 AA AB AC AD AE AF B0 B1 80 80 80 80 80 80 37 37 37 37 37 37 80 80 80 80 80 80 37 37 37 37 37 37 PANEL gain adj. EVF gain adj. PANEL gain adj. 70 20 20 70 20 20 79 31 32 79 31 32 70 8A 61 70 8A 61 E0 E0 EE 00 00 00 EE 00 00 00 Fixed data-1 (Initialized data) CAP FG duty adj. Fixed data-1 (Initialized data) S VIDEO OUT Y level adj. (NTSC)/Fixed data-1 (PAL) S VIDEO OUT chroma level adj. (NTSC)/Fixed data-1 (PAL) Fixed data-1 (Initialized data) Fixed data-1(NTSC)/S VIDEO OUT Y level adj. (PAL) Fixed data-1(NTSC)/S VIDEO OUT chroma level adj. (PAL) Fixed data-1 (Initialized data) COMPONENT OUT Y level adj. COMPONENT OUT Pb level adj. COMPONENT OUT Pr level adj. Fixed data-1 (Initialized data) V-COM adj. (LCD) Transmissive mode white balance adj. (LCD) Fixed data-1 (Initialized data) Switching position adj.

Address B2 B3 B4 B5 B6 B7 B8 B9 BA BB BC BD BE BF C0 C1 C2 C3 C4 C5 C6 C7 C8 to EA EB EC to F3 F4 F5 F6 F7 F8 F9 FA FB FC FD FE FF

Initial value NTSC PAL 00 00 00 00 00 80 00 00 00 00 00 00 00 00 00 00 80 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 80 00 00 00 00 00 00 00 00 00 00 80 00 00 00 00 00

Remark

Error rate check

Fixed data-1 (Initialized data) 00 00 00 00 00 00 00 00 00 00 00 00 00 Emergence memory address (Mechanism section) Est Error Code Fixed data-2

HDR-FX1000/FX1000E_ADJ 6-13

Ver. 1.1 2008.11
The changed portions from Ver. 1.0 are shown in blue.

6. 13 Page table Note 1: If reading/writing data on pages 13, set data: 01 to page: 0, address: 10, and then select pages: 3. By this data setting, the pages 13 can be selected. After the data reading/writing finished, return the data on page: 0, address: 10 to "00". Note 2: Fixed data-1: Initialized data. (Refer to "1. Initializing the 8, 9, C, 13, 18, 1C, 1D, 1E Page Data") Fixed data-2: Modified data. (Refer to "2. Modification of 8, 9, C, 13, 18, 1C, 1D, 1E Page Data") Initial value Address Remark NTSC PAL 00 to 03 04 05 06 07 08 09 0A 0B 0C 0D 0E 0F 10 11 12 13 14 15 16 17 18 to 23 24 25 26 to FF 01 ­ 01 7F 00 08 00 46 01 02 00 00 00 48 44 52 2D 46 58 31 30 30 30 08 00 46 01 02 00 00 00 48 44 52 2D 46 58 31 30 30 30 45 00 Fixed data-1 (Initialized data) Module No. Fixed data-1 (NTSC)/ Module No. (PAL) Fixed data-1 (Initialized data) Model Name (SDD data) Node unique ID No. input Fixed data-1 (Initialized data)

7. 18 Page table Note 1: If reading/writing data on pages 18, set data: 01 to page: 0, address: 10, and then select pages: 8. By this data setting, the pages 18 can be selected. After the data reading/writing finished, return the data on page: 0, address: 10 to "00". Note 2: Fixed data-1: Initialized data. (Refer to "1. Initializing the 8, 9, C, 13, 18, 1C, 1D, 1E Page Data") Fixed data-2: Modified data. (Refer to "2. Modification of 8, 9, C, 13, 18, 1C, 1D, 1E Page Data") Initial value Address Remark NTSC PAL 00 to DD DE DF to FF Fixed data-1 (Initialized data) Fixed data-2 Fixed data-1 (Initialized data)

HDR-FX1000/FX1000E_ADJ 6-14

Ver. 1.1 2008.11
The changed portions from Ver. 1.0 are shown in blue.

8. 1C Page table Note 1: If reading/writing data on pages 1C, set data: 01 to page: 0, address: 10, and then select pages: C. By this data setting, the pages 1C can be selected. After the data reading/writing finished, return the data on page: 0, address: 10 to"00". Note 2: Fixed data-1: Initialized data. (Refer to "1. Initializing the 8, 9, C, 13, 18, 1C, 1D, 1E Page Data") Fixed data-2: Modified data. (Refer to "2. Modification of 8, 9, C, 13, 18, 1C, 1D, 1E Page Data") Initial value Address Remark NTSC PAL 00 to FF Fixed data-1 (Initialized data)

9. 1D Page table Note 1: If reading/writing data on pages 1D, set data: 01 to page: 0, address: 10, and then select pages: D. By this data setting, the pages 1D can be selected. After the data reading/writing finished, return the data on page: 0, address: 10 to "00". Note 2: Fixed data-1: Initialized data. (Refer to "1. Initializing the 8, 9, C, 13, 18, 1C, 1D, 1E Page Data") Fixed data-2: Modified data. (Refer to "2. Modification of 8, 9, C, 13, 18, 1C, 1D, 1E Page Data") Address 00 to FF Initial value NTSC PAL Remark Fixed data-1 (Initialized data)

10. 1E Page table Note 1: If reading/writing data on pages 1E, set data: 01 to page: 0, address: 10, and then select pages: E. By this data setting, the pages 1E can be selected. After the data reading/writing finished, return the data on page: 0, address: 10 to "00". Note 2: Fixed data-1: Initialized data. (Refer to "1. Initializing the 8, 9, C, 13, 18, 1C, 1D, 1E Page Data") Fixed data-2: Modified data. (Refer to "2. Modification of 8, 9, C, 13, 18, 1C, 1D, 1E Page Data") Address 00 to 65 66 67 to 81 82 83, 84 85, 86 87 to FF Initial value NTSC PAL Fixed data-2 Fixed data-1 (Initialized data) Fixed data-2 Fixed data-1 (Initialized data) Fixed data-2 Fixed data-1 (Initialized data) Remark Fixed data-1 (Initialized data)

HDR-FX1000/FX1000E_ADJ 6-15

1-2-3.

Initialization of Camera Control Page Data

1. Initializing of Camera Control Page Data Note 1: If "Initialization of Camera Control Page Data" is executed, all data on camera control page are initialized. (Only an individual page cannot be initialized) Note 2: If the camera control page data has been initialized, the following adjustments need to be performed again. 1) Modification of camera control page data 2) Camera system adjustment (if all areas were initialized) Adjustment Page Adjustment Address Adjustment Page Adjustment Address Adjustment Page Adjustment Address Adjustment Page Adjustment Address Adjustment Page Adjustment Address Adjustment Page Adjustment Address Adjustment Page Adjustment Address Adjustment Page Adjustment Address Adjustment Page Adjustment Address Adjustment Page Adjustment Address Adjustment Page Adjustment Address Adjustment Page Adjustment Address Adjustment Page Adjustment Address Adjustment Page Adjustment Address Adjustment Page Adjustment Address Adjustment Page Adjustment Address Adjustment Page Adjustment Address Adjustment Page Adjustment Address Adjustment Page Adjustment Address Adjustment Page Adjustment Address Adjustment Page Adjustment Address Adjustment Page Adjustment Address 6D 00 to F9 6E 00 to FF 6F 10 to FF 7C 00 to FF 7E 00 to FF 7F 00 to FF 8C 00 to F9 8D 00 to FF 8E 00 to FF 8F 00 to FF 9D 00 to 4F 9E 00 to FF 9F 00 to FF AD 00 to 4F AE 00 to F1 AF 00 to FF BE 00 to F9 BF 00 to FF C2 00 to FF C3 00 to FF C4 00 to FF C5 00 to FF

Adjustment Page Adjustment Address Adjustment Page Adjustment Address Adjustment Page Adjustment Address Adjustment Page Adjustment Address Adjustment Page Adjustment Address Adjustment Page Adjustment Address Adjustment Page Adjustment Address Adjustment Page Adjustment Address Adjustment Page Adjustment Address Adjustment Page Adjustment Address Initializing method:

C6 00 to DF C7 00 to FF C8 00 to FF C9 00 to FF CA 00 to FF CB 00 to DF CC 00 to C7 CD 00 to FF CE 00 to FF CF 00 to FF

Order Page Address Data 1 2 3 0 0 2 01 10 EA 01 00

Procedure

4

6

01

5 6 7 8

6 6 6 0 2 (72) 2 (72) 2 (72) 0

03 02 01 10

01

00 7

Check the bit1 value. 1: NTSC model 0: PAL model Set the following data, and press PAUSE (Write) button. (Note 3) NTSC model: 2D: Initializing all areas 31: Initializing other than adjustment address PAL model: 2F: Initializing all areas 33: Initializing other than adjustment address Press PAUSE (Write) button. Check the data changes to "01". Press PAUSE (Write) button. Set the following data, and press PAUSE (Write) button. 2D: Initializing all areas 31: Initializing other than adjustment address Check the data changes to "01".

9

01

10 11 12 13

02 01 10 00 00

Press PAUSE (Write) button.

Perform "Modification of Camera Control Data".

Note 3: If other than adjustment address was initialized, the adjusted data is not initialized. Note 4: NTSC model: HDR-FX1000 PAL model: HDR-FX1000E

HDR-FX1000/FX1000E_ADJ 6-16

Ver. 1.1 2008.11

2. Modification of Camera Control Page Data If the camera control page data has been initialized, change the data of the "Fixed data-2" address shown in the following table by manual input. Modifying Method: 1) Before changing the data, select page: 0, address: 01, and set data: 01. 2) If 2-digit page is selected, set higher-order digit to page: 0, address: 10 as data, and then select lower-order digit by a usual method. e.g.: Set data: 06 to page: 0, address: 10, and then select page: D. Thus, the page 6D can be selected. After the modification of data finished, return the data on page: 0, address: 10 to "00". 3) New data for changing are not shown in the tables because they are different in destination. When changing the data, copy the data built in the same model. Note: If copy the data built in the different model, the camcorder may not operate. 4) When changing the data, press the PAUSE button of the adjustment remote commander each time when setting new data to write the data in the non-volatile memory. 5) If all areas were initialized, check that the data at the addresses for adjustment are initial values (adjustment initial values) listed in the table. If different, change them to the adjustment initial values. 6) Select page: 0, address: 01, set data: 01. 7) Select page: 3, address: 71, set data: 01, and press PAUSE (Write) button. Processing after Completing Modification Camera Control Data: Order Page Address Data 1 2 3 4 5 0 3 3 2 2 10 70 70 00 01 29 29 Press PAUSE (Write) button. 00 10 Press PAUSE (Write) button. Check the data changes to "11". Procedure

3. 6D Page table Note 1: If reading/writing data on pages 6D, set data: 06 to page: 0, address: 10, and then select pages: D. By this data setting, the pages 6D can be selected. After the data reading/writing finished, return the data on page: 0, address: 10 to "00". Note 2: Fixed data-1: Initialized data. (Refer to "1. Initializing the Camera Control Data") Fixed data-2: Modified data. (Refer to "2. Modification of Camera Control Data") Initial value Address Remark NTSC PAL 00 to 59 5A 5B 5C 5D 5E 5F 60 to F9 36 10 0B 6E 36 10 0B 6E 00 00 Fixed data-1 (Initialized data) STD gain adj. Fixed data-1 (Initialized data) LV Standard data input MAX gain adj. Fixed data-1 (Initialized data)

HDR-FX1000/FX1000E_ADJ 6-17

4. 6E Page table Note 1: If reading/writing data on pages 6E, set data: 06 to page: 0, address: 10, and then select pages: E. By this data setting, the pages 6E can be selected. After the data reading/writing finished, return the data on page: 0, address: 10 to "00". Note 2: Fixed data-1: Initialized data. (Refer to "1. Initializing the Camera Control Data") Fixed data-2: Modified data. (Refer to "2. Modification of Camera Control Data") Initial value Address Remark NTSC PAL 00 to FF Fixed data-1 (Initialized data)

8. 7F Page table Note 1: If reading/writing data on pages 7F, set data: 07 to page: 0, address: 10, and then select pages: F. By this data setting, the pages 7F can be selected. After the data reading/writing finished, return the data on page: 0, address: 10 to "00". Note 2: Fixed data-1: Initialized data. (Refer to "1. Initializing the Camera Control Data") Fixed data-2: Modified data. (Refer to "2. Modification of Camera Control Data") Initial value Address Remark NTSC PAL 00 01 02 03 04 05 06 07 08 09 0A 0B 0C 0D 0E 0F 10 11 12 13 14 15 16 17 18 19 1A 1B 1C 1D 1E 1F 20 21 22 to 7F 80 80 02 C2 02 C2 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 60 60 80 80 02 C2 02 C2 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 60 60 Angular Velocity Sensor Sensitivity Adjustment Fixed data-1 (Initialized data) PSD Sensor Gradient Adjustment

5. 6F Page table Note 1: If reading/writing data on pages 6F, set data: 06 to page: 0, address: 10, and then select pages: F. By this data setting, the pages 6F can be selected. After the data reading/writing finished, return the data on page: 0, address: 10 to "00". Note 2: Fixed data-1: Initialized data. (Refer to "1. Initializing the Camera Control Data") Fixed data-2: Modified data. (Refer to "2. Modification of Camera Control Data") Initial value Address Remark NTSC PAL 10 to FF Fixed data-1 (Initialized data)

6. 7C Page table Note 1: If reading/writing data on pages 7C, set data: 07 to page: 0, address: 10, and then select pages: C. By this data setting, the pages 7C can be selected. After the data reading/writing finished, return the data on page: 0, address: 10 to "00". Note 2: Fixed data-1: Initialized data. (Refer to "1. Initializing the Camera Control Data") Fixed data-2: Modified data. (Refer to "2. Modification of Camera Control Data") Initial value Address Remark NTSC PAL 00 to FF Fixed data-1 (Initialized data)

7. 7E Page table Note 1: If reading/writing data on pages 7E, set data: 07 to page: 0, address: 10, and then select pages: E. By this data setting, the pages 7E can be selected. After the data reading/writing finished, return the data on page: 0, address: 10 to "00". Note 2: Fixed data-1: Initialized data. (Refer to "1. Initializing the Camera Control Data") Fixed data-2: Modified data. (Refer to "2. Modification of Camera Control Data") Initial value Address Remark NTSC PAL 00 to FF Fixed data-1 (Initialized data)

HDR-FX1000/FX1000E_ADJ 6-18

Ver. 1.1 2008.11
The changed portions from Ver. 1.0 are shown in blue.

9. 8C Page table Note 1: If reading/writing data on pages 8C, set data: 08 to page: 0, address: 10, and then select pages: C. By this data setting, the pages 8C can be selected. After the data reading/writing finished, return the data on page: 0, address: 10 to "00". Note 2: Fixed data-1: Initialized data. (Refer to "1. Initializing the Camera Control Data") Fixed data-2: Modified data. (Refer to "2. Modification of Camera Control Data") Initial value Address Remark NTSC PAL 00 to 45 46 47 to DE DF E0 E1 E2 to F9 Fixed data-1 (Initialized data) Fixed data-2 Fixed data-1 (Initialized data) Fixed data-2 Fixed data-1 (Initialized data) Fixed data-2 Fixed data-1 (Initialized data)

10. 8D Page table Note 1: If reading/writing data on pages 8D, set data: 08 to page: 0, address: 10, and then select pages: D. By this data setting, the pages 8D can be selected. After the data reading/writing finished, return the data on page: 0, address: 10 to "00". Note 2: Fixed data-1: Initialized data. (Refer to "1. Initializing the Camera Control Data") Fixed data-2: Modified data. (Refer to "2. Modification of Camera Control Data") Initial value Address Remark NTSC PAL 00 to FF Fixed data-1 (Initialized data)

11. 8E Page table Note 1: If reading/writing data on pages 8E, set data: 08 to page: 0, address: 10, and then select pages: E. By this data setting, the pages 8E can be selected. After the data reading/writing finished, return the data on page: 0, address: 10 to "00". Note 2: Fixed data-1: Initialized data. (Refer to "1. Initializing the Camera Control Data") Fixed data-2: Modified data. (Refer to "2. Modification of Camera Control Data") Initial value Address Remark NTSC PAL 00 to 08 09 to 0E 0F, 10 11 to 16 17, 18 19 to 1C 1D 1E 1F, 20 21 to 24 25 26 27, 28 Fixed data-1 (Initialized data) Fixed data-2 Fixed data-1 (Initialized data) Fixed data-2 Fixed data-1 (Initialized data) Fixed data-2 Fixed data-1 (Initialized data) Fixed data-2 Fixed data-1 (Initialized data) Fixed data-2 Fixed data-1 (Initialized data) Fixed data-2 Fixed data-1 (Initialized data)

HDR-FX1000/FX1000E_ADJ 6-19

Ver. 1.1 2008.11
The changed portions from Ver. 1.0 are shown in blue.

Address 29 to 2C 2D 2E 2F to 38 39 to 3E 3F, 40 41 to 44 45 to 48 49 4A to 50 51 52 to 58 59 5A to 66 67 68 to 7E 7F 80 to FF

Initial value NTSC PAL Fixed data-2

Remark

Fixed data-1 (Initialized data) Fixed data-2 Fixed data-1 (Initialized data) Fixed data-2 Fixed data-1 (Initialized data) Fixed data-2 Fixed data-1 (Initialized data) Fixed data-2 Fixed data-1 (Initialized data) Fixed data-2 Fixed data-1 (Initialized data) Fixed data-2 Fixed data-1 (Initialized data) Fixed data-2 Fixed data-1 (Initialized data) Fixed data-2 Fixed data-1 (Initialized data)

12. 8F Page table Note 1: If reading/writing data on pages 8F, set data: 08 to page: 0, address: 10, and then select pages: F. By this data setting, the pages 8F can be selected. After the data reading/writing finished, return the data on page: 0, address: 10 to "00". Note 2: Fixed data-1: Initialized data. (Refer to "1. Initializing the Camera Control Data") Fixed data-2: Modified data. (Refer to "2. Modification of Camera Control Data") Initial value Address Remark NTSC PAL 00 01 to 05 06 to 08 09 0A to 0F 10 11, 12 13 14 to 32 33 34 35 36 to 38 39 3A 3B 3C to 77 78 to 7A 7B to 7D 7E, 7F 80 to 8F 90, 91 92 to A3 A4, A5 A6 to C1 C2 C3 to E1 E2 E3 E4, E5 E6 to FF Fixed data-1 (Initialized data) Fixed data-2 Fixed data-1 (Initialized data) Fixed data-2 Fixed data-1 (Initialized data) Fixed data-2 Fixed data-1 (Initialized data) Fixed data-2 Fixed data-1 (Initialized data) Fixed data-2 Fixed data-1 (Initialized data) Fixed data-2 Fixed data-1 (Initialized data) Fixed data-2 Fixed data-1 (Initialized data) Fixed data-2 Fixed data-1 (Initialized data) Fixed data-2 Fixed data-1 (Initialized data) Fixed data-2 Fixed data-1 (Initialized data) Fixed data-2 Fixed data-1 (Initialized data) Fixed data-2 Fixed data-1 (Initialized data) Fixed data-2 Fixed data-1 (Initialized data) Fixed data-2 Fixed data-1 (Initialized data) Fixed data-2 Fixed data-1 (Initialized data)

HDR-FX1000/FX1000E_ADJ 6-20

13. 9D Page table Note 1: If reading/writing data on pages 9D, set data: 09 to page: 0, address: 10, and then select pages: D. By this data setting, the pages 9D can be selected. After the data reading/writing finished, return the data on page: 0, address: 10 to "00". Note 2: Fixed data-1: Initialized data. (Refer to "1. Initializing the Camera Control Data") Fixed data-2: Modified data. (Refer to "2. Modification of Camera Control Data") Initial value Address Remark NTSC PAL 00 to 4F Fixed data-1 (Initialized data)

17. AE Page table Note 1: If reading/writing data on pages AE, set data: 0A to page: 0, address: 10, and then select pages: E. By this data setting, the pages AE can be selected. After the data reading/writing finished, return the data on page: 0, address: 10 to "00". Note 2: Fixed data-1: Initialized data. (Refer to "1. Initializing the Camera Control Data") Fixed data-2: Modified data. (Refer to "2. Modification of Camera Control Data") Initial value Address Remark NTSC PAL 00 to 7B 7C, 7D 7E to F1 Fixed data-1 (Initialized data) Fixed data-2 Fixed data-1 (Initialized data)

14. 9E Page table Note 1: If reading/writing data on pages 9E, set data: 09 to page: 0, address: 10, and then select pages: E. By this data setting, the pages 9E can be selected. After the data reading/writing finished, return the data on page: 0, address: 10 to "00". Note 2: Fixed data-1: Initialized data. (Refer to "1. Initializing the Camera Control Data") Fixed data-2: Modified data. (Refer to "2. Modification of Camera Control Data") Initial value Address Remark NTSC PAL 00 to FF Fixed data-1 (Initialized data)

18. AF Page table Note 1: If reading/writing data on pages AF, set data: 0A to page: 0, address: 10, and then select pages: F. By this data setting, the pages AF can be selected. After the data reading/writing finished, return the data on page: 0, address: 10 to "00". Note 2: Fixed data-1: Initialized data. (Refer to "1. Initializing the Camera Control Data") Fixed data-2: Modified data. (Refer to "2. Modification of Camera Control Data") Initial value Address Remark NTSC PAL 00 to FF Fixed data-1 (Initialized data)

15. 9F Page table Note 1: If reading/writing data on pages 9F, set data: 09 to page: 0, address: 10, and then select pages: F. By this data setting, the pages 9F can be selected. After the data reading/writing finished, return the data on page: 0, address: 10 to "00". Note 2: Fixed data-1: Initialized data. (Refer to "1. Initializing the Camera Control Data") Fixed data-2: Modified data. (Refer to "2. Modification of Camera Control Data") Initial value Address Remark NTSC PAL 00 to FF Fixed data-1 (Initialized data)

19. BE Page table Note 1: If reading/writing data on pages BE, set data: 0B to page: 0, address: 10, and then select pages: E. By this data setting, the pages BE can be selected. After the data reading/writing finished, return the data on page: 0, address: 10 to "00". Note 2: Fixed data-1: Initialized data. (Refer to "1. Initializing the Camera Control Data") Fixed data-2: Modified data. (Refer to "2. Modification of Camera Control Data") Initial value Address Remark NTSC PAL 00 to CA CB to D0 D1 to F9 Fixed data-1 (Initialized data) Fixed data-2 Fixed data-1 (Initialized data)

16. AD Page table Note 1: If reading/writing data on pages AD, set data: 0A to page: 0, address: 10, and then select pages: D. By this data setting, the pages AD can be selected. After the data reading/writing finished, return the data on page: 0, address: 10 to "00". Note 2: Fixed data-1: Initialized data. (Refer to "1. Initializing the Camera Control Data") Fixed data-2: Modified data. (Refer to "2. Modification of Camera Control Data") Initial value Address Remark NTSC PAL 00 to 4F Fixed data-1 (Initialized data)

HDR-FX1000/FX1000E_ADJ 6-21

Ver. 1.1 2008.11
The changed portions from Ver. 1.0 are shown in blue.

20. BF Page table Note 1: If reading/writing data on pages BF, set data: 0B to page: 0, address: 10, and then select pages: F. By this data setting, the pages BF can be selected. After the data reading/writing finished, return the data on page: 0, address: 10 to "00". Note 2: Fixed data-1: Initialized data. (Refer to "1. Initializing the Camera Control Data") Fixed data-2: Modified data. (Refer to "2. Modification of Camera Control Data") Initial value Address Remark NTSC PAL 00 to 44 45 46 to 63 64 to 6A 6B to BC BD BE to FF Fixed data-1 (Initialized data) Fixed data-2 Fixed data-1 (Initialized data) Fixed data-2 Fixed data-1 (Initialized data) Fixed data-2 Fixed data-1 (Initialized data)

23. C4 Page table Note 1: If reading/writing data on pages C4, set data: 0C to page: 0, address: 10, and then select pages: 4. By this data setting, the pages C4 can be selected. After the data reading/writing finished, return the data on page: 0, address: 10 to "00". Note 2: Fixed data-1: Initialized data. (Refer to "1. Initializing the Camera Control Data") Fixed data-2: Modified data. (Refer to "2. Modification of Camera Control Data") Initial value Address Remark NTSC PAL 00 to FF Fixed data-1 (Initialized data)

21. C2 Page table Note 1: If reading/writing data on pages C2, set data: 0C to page: 0, address: 10, and then select pages: 2. By this data setting, the pages C2 can be selected. After the data reading/writing finished, return the data on page: 0, address: 10 to "00". Note 2: Fixed data-1: Initialized data. (Refer to "1. Initializing the Camera Control Data") Fixed data-2: Modified data. (Refer to "2. Modification of Camera Control Data") Initial value Address Remark NTSC PAL 00 to FF Fixed data-1 (Initialized data)

24. C5 Page table Note 1: If reading/writing data on pages C5, set data: 0C to page: 0, address: 10, and then select pages: 5. By this data setting, the pages C5 can be selected. After the data reading/writing finished, return the data on page: 0, address: 10 to "00". Note 2: Fixed data-1: Initialized data. (Refer to "1. Initializing the Camera Control Data") Fixed data-2: Modified data. (Refer to "2. Modification of Camera Control Data") Initial value Address Remark NTSC PAL 00 to FF Fixed data-1 (Initialized data)

22. C3 Page table Note 1: If reading/writing data on pages C3, set data: 0C to page: 0, address: 10, and then select pages: 3. By this data setting, the pages C3 can be selected. After the data reading/writing finished, return the data on page: 0, address: 10 to "00". Note 2: Fixed data-1: Initialized data. (Refer to "1. Initializing the Camera Control Data") Fixed data-2: Modified data. (Refer to "2. Modification of Camera Control Data") Initial value Address Remark NTSC PAL 00 to FF Fixed data-1 (Initialized data)

25. C6 Page table Note 1: If reading/writing data on pages C6, set data: 0C to page: 0, address: 10, and then select pages: 6. By this data setting, the pages C6 can be selected. After the data reading/writing finished, return the data on page: 0, address: 10 to "00". Note 2: Fixed data-1: Initialized data. (Refer to "1. Initializing the Camera Control Data") Fixed data-2: Modified data. (Refer to "2. Modification of Camera Control Data") Initial value Address Remark NTSC PAL 00 to DF Fixed data-1 (Initialized data)

26. C7 Page table Note 1: If reading/writing data on pages C7, set data: 0C to page: 0, address: 10, and then select pages: 7. By this data setting, the pages C7 can be selected. After the data reading/writing finished, return the data on page: 0, address: 10 to "00". Note 2: Fixed data-1: Initialized data. (Refer to "1. Initializing the Camera Control Data") Fixed data-2: Modified data. (Refer to "2. Modification of Camera Control Data") Address 00 to FF Initial value NTSC PAL Remark Fixed data-1 (Initialized data)

HDR-FX1000/FX1000E_ADJ 6-22

27. C8 Page table Note 1: If reading/writing data on pages C8, set data: 0C to page: 0, address: 10, and then select pages: 8. By this data setting, the pages C8 can be selected. After the data reading/writing finished, return the data on page: 0, address: 10 to "00". Note 2: Fixed data-1: Initialized data. (Refer to "1. Initializing the Camera Control Data") Fixed data-2: Modified data. (Refer to "2. Modification of Camera Control Data") Initial value Address Remark NTSC PAL 00 to FF Fixed data-1 (Initialized data)

30. CB Page table Note 1: If reading/writing data on pages CB, set data: 0C to page: 0, address: 10, and then select pages: B. By this data setting, the pages CB can be selected. After the data reading/writing finished, return the data on page: 0, address: 10 to "00". Note 2: Fixed data-1: Initialized data. (Refer to "1. Initializing the Camera Control Data") Fixed data-2: Modified data. (Refer to "2. Modification of Camera Control Data") Initial value Address Remark NTSC PAL 00 to DF Fixed data-1 (Initialized data)

28. C9 Page table Note 1: If reading/writing data on pages C9, set data: 0C to page: 0, address: 10, and then select pages: 9. By this data setting, the pages C9 can be selected. After the data reading/writing finished, return the data on page: 0, address: 10 to "00". Note 2: Fixed data-1: Initialized data. (Refer to "1. Initializing the Camera Control Data") Fixed data-2: Modified data. (Refer to "2. Modification of Camera Control Data") Initial value Address Remark NTSC PAL 00 to FF Fixed data-1 (Initialized data)

31. CC Page table Note 1: If reading/writing data on pages CC, set data: 0C to page: 0, address: 10, and then select pages: C. By this data setting, the pages CC can be selected. After the data reading/writing finished, return the data on page: 0, address: 10 to "00". Note 2: Fixed data-1: Initialized data. (Refer to "1. Initializing the Camera Control Data") Fixed data-2: Modified data. (Refer to "2. Modification of Camera Control Data") Initial value Address Remark NTSC PAL 00 to C7 Fixed data-1 (Initialized data)

29. CA Page table Note 1: If reading/writing data on pages CA, set data: 0C to page: 0, address: 10, and then select pages: A. By this data setting, the pages CA can be selected. After the data reading/writing finished, return the data on page: 0, address: 10 to "00". Note 2: Fixed data-1: Initialized data. (Refer to "1. Initializing the Camera Control Data") Fixed data-2: Modified data. (Refer to "2. Modification of Camera Control Data") Initial value Address Remark NTSC PAL 00 to FF Fixed data-1 (Initialized data)

HDR-FX1000/FX1000E_ADJ 6-23

Ver. 1.1 2008.11
The changed portions from Ver. 1.0 are shown in blue.

32. CD Page table Note 1: If reading/writing data on pages CD, set data: 0C to page: 0, address: 10, and then select pages: D. By this data setting, the pages CD can be selected. After the data reading/writing finished, return the data on page: 0, address: 10 to "00". Note 2: Fixed data-1: Initialized data. (Refer to "1. Initializing the Camera Control Data") Fixed data-2: Modified data. (Refer to "2. Modification of Camera Control Data") Initial value Address Remark NTSC PAL 00 to 11 12 13 to 1C 1D 1E to 2F 30 to 32 33 34, 35 36 37 to 3A 3B 3C, 3D 3E 3F 40 to 4F 50 51 to 53 54 to 57 58 to 87 88 to 95 96 to 99 9A to A3 A4, A5 A6 to AB AC, AD AE to B3 B4, B5 B6 to B9 BA to BE BF C0 to C2 C3 C4 C5 C6 C7 C8 C9 CA Fixed data-1 (Initialized data) Fixed data-2 Fixed data-1 (Initialized data) Fixed data-2 Fixed data-1 (Initialized data) Fixed data-2 Fixed data-1 (Initialized data) Fixed data-2 Fixed data-1 (Initialized data) Fixed data-2 Fixed data-1 (Initialized data) Fixed data-2 Fixed data-1 (Initialized data) Fixed data-2 Fixed data-1 (Initialized data) Fixed data-2 Fixed data-1 (Initialized data) Fixed data-2 Fixed data-1 (Initialized data) Fixed data-2 Fixed data-1 (Initialized data) Fixed data-2 Fixed data-1 (Initialized data) Fixed data-2 Fixed data-1 (Initialized data) Fixed data-2 Fixed data-1 (Initialized data) Fixed data-2 Fixed data-1 (Initialized data) Fixed data-2 Fixed data-1 (Initialized data) Fixed data-2 Fixed data-1 (Initialized data) Fixed data-2 Fixed data-1 (Initialized data) Fixed data-2 Fixed data-1 (Initialized data) Fixed data-2 Fixed data-1 (Initialized data)

Address CB CC CD CE CF D0 to FF

Initial value NTSC PAL Fixed data-2

Remark

Fixed data-1 (Initialized data) Fixed data-2 Fixed data-1 (Initialized data) Fixed data-2 Fixed data-1 (Initialized data)

HDR-FX1000/FX1000E_ADJ 6-24

Ver. 1.1 2008.11
The changed portions from Ver. 1.0 are shown in blue.

33. CE Page table Note 1: If reading/writing data on pages CE, set data: 0C to page: 0, address: 10, and then select pages: E. By this data setting, the pages CE can be selected. After the data reading/writing finished, return the data on page: 0, address: 10 to "00". Note 2: Fixed data-1: Initialized data. (Refer to "1. Initializing the Camera Control Data") Fixed data-2: Modified data. (Refer to "2. Modification of Camera Control Data") Initial value Address Remark NTSC PAL 00 to 03 04 05 to 0F 10 to 13 14 to 1D 1E, 1F 20 to 22 23, 24 25 26 27 to 2A 2B, 2C 2D 2E to 31 32 33 34 35, 36 37 to 3A 3B, 3C 3D to 5C 5D 5E to 79 7A to 7D 7E to 83 84, 85 86 to 91 92, 93 94 to 97 98 to 9D 9E 9F A0 to C1 C2 to C5 C6 to EE EF F0 to FF Fixed data-1 (Initialized data) Fixed data-2 Fixed data-1 (Initialized data) Fixed data-2 Fixed data-1 (Initialized data) Fixed data-2 Fixed data-1 (Initialized data) Fixed data-2 Fixed data-1 (Initialized data) Fixed data-2 Fixed data-1 (Initialized data) Fixed data-2 Fixed data-1 (Initialized data) Fixed data-2 Fixed data-1 (Initialized data) Fixed data-2 Fixed data-1 (Initialized data) Fixed data-2 Fixed data-1 (Initialized data) Fixed data-2 Fixed data-1 (Initialized data) Fixed data-2 Fixed data-1 (Initialized data) Fixed data-2 Fixed data-1 (Initialized data) Fixed data-2 Fixed data-1 (Initialized data) Fixed data-2 Fixed data-1 (Initialized data) Fixed data-2 Fixed data-1 (Initialized data) Fixed data-2 Fixed data-1 (Initialized data) Fixed data-2 Fixed data-1 (Initialized data) Fixed data-2 Fixed data-1 (Initialized data)

34. CF Page table Note 1: If reading/writing data on pages CF, set data: 0C to page: 0, address: 10, and then select pages: F. By this data setting, the pages CF can be selected. After the data reading/writing finished, return the data on page: 0, address: 10 to "00". Note 2: Fixed data-1: Initialized data. (Refer to "1. Initializing the Camera Control Data") Fixed data-2: Modified data. (Refer to "2. Modification of Camera Control Data") Initial value Address Remark NTSC PAL 00 to 8F 90 to 9F A0 to B0 B1 to BD BE BF C0 to C7 C8 to CF D0 to E8 E9 EA EB to EF F0 to FF Fixed data-1 (Initialized data) Fixed data-2 Fixed data-1 (Initialized data) Fixed data-2 Fixed data-1 (Initialized data) Fixed data-2 Fixed data-1 (Initialized data) Fixed data-2 Fixed data-1 (Initialized data) Fixed data-2 Fixed data-1 (Initialized data) Fixed data-2 Fixed data-1 (Initialized data)

HDR-FX1000/FX1000E_ADJ 6-25

1-3.

CAMERA SYSTEM ADJUSTMENTS

Before perform the camera system adjustments, check that the specified values of "VIDEO SYSTEM ADJUSTMENTS" are satisfied. (Except Origin Oscillation Check") Check that the data of page: 0, address: 10 is "00". If not, select page: 0, address: 10, and set the data "00". 1-3-1. Camera System Adjustments

2. Coaxial Harness Connecting Check RadarW Check if the coaxial harness of CMOS is connected correctly. Subject Measurement Point Measuring Instrument Adjustment Page Adjustment Address Specified value Not required Adjusting remote commander 6 D1 to D6 Data of page: 6, address: D0 is "07"

1. Origin Oscillation Check (VC-543 board) Check the frequency of the clock for synchronization. If deviated, the synchronization will be disrupted and the color will become inconsistent. Subject Measurement Point Measuring Instrument Specified value Not required R1414 (CHCK) on VC-543 board Frequency counter f = 41538461 ± 835 Hz (NTSC) f = 41580000 ± 835 Hz (PAL)

Note 1: Check that the data of page: 6, address: 02 is "00" If not, select page: 6, address: 01, set data: 00, and press the PAUSE (Write) button. Switch setting 1) POWER ......................................................... CAMERA mode Adjusting method: Order Page Address Data 1 2 3 0 6 0 E (9E) E (9E) 0 6 6 6 01 07 10 90 80 10 01 02 D0 09 10 00 00 EB Press PAUSE (Write) button.(Note 2) Check the data changes to "01". Check the data is "07". (Note 3) 01 Check the data is "04". Procedure

Switch setting 1) POWER ......................................................... CAMERA mode Checking method: 1) Check that the frequency (f) satisfies the specified value.
VC-543 BOARD (SIDE A)

4 5 6 7

IC1601

8 9

IC1401

Note 2: The adjustment data will be automatically input to page: 6, address: D1 to D6. Note 3: For the error codes of bit 0 to bit 2 of data of page: 6, address: D0, see the following table. Bit value of data of page: 6, address: D0 Bit 0 1 2 Function R G B

Error contents When bit value = 0 When bit value = 1 Error exists Error exists Error exists No error No error No error

Example: If an error exists in G, data is "05"
R1414

Processing after Completing Adjustment:

Fig. 6-1-5

Order Page Address Data 1 2 3 4 5 6 6 0 E (9E) E (9E) 0 0 01 10 90 80 10 01 00 09 00 70 00 00

Procedure Press PAUSE (Write) button.

HDR-FX1000/FX1000E_ADJ 6-26

3.

PSD Sensor Gradient Adjustment (VC-543 board)

RadarW
Input average offset voltage of the YAW (SE8502)/PITCH (SE8501) sensors on GY-014 board. Subject Measurement Point Measuring Instrument Adjustment Page Adjustment Address Specified value 7F 00 to 1F Data of page: 72, address: 02 is "01" Not required Adjusting remote commander

4. Lens Adjustment RadarW The inner focus lens MR adjustment is carried out automatically. Subject Measurement Point Measuring Instrument Adjustment Page Adjustment Address Specified value Not required Adjusting remote commander 6F 30, 40 to 4F Data of page: 6, address: 0C is "00"

Note 1: Set the camera on a horizontal table. Note 2: Check that the data of page: 72, address: 02 is "00" If not, select page: 72, address: 01, set data: 00, and press the PAUSE (Write) button. Adjusting method: Order Page Address Data 1 2 3 4 5 6 7 8 9 2 (72) F (7F) 2 (72) 0 0 02 16 01 10 01 00 00 00 0 0 2 (72) 01 10 01 01 7 97 Press PAUSE (Write) button. (Note 3) Wait for 6 seconds. Check the data changes to "01". (Note 4) Check the data changes to "11". Press PAUSE (Write) button. Procedure

Note 1: Perform the adjustment with the lens in horizontal state. Note 2: Perform "Flange Back Adjustment " after this adjustment. Note 3: If reading/writing data on page 6F, set data: 06 to page: 0, address: 10, and then select page F. By this data setting, the page 6F can be selected. After the data reading/writing finished, return the data on page: 0, address: 10 to "00". Switch setting 1) POWER ......................................................... CAMERA mode Adjusting method: Order Page Address Data 1 2 3 4 5 0 6 6 6 6 01 02 01 02 0C BD 01 Check the data is "00". (Note 4) Press PAUSE (Write) button. (Note 5) Check the data changes to "01". Check the data is "00". Procedure

Note 4: If not, select page: 6, address: 01, set data: 00, and press the PAUSE (Write) button. Note 5: The adjustment data will be automatically input to page: 6F, address: 30, 40 to 4F. Processing after Completing Adjustment: Order Page Address Data 1 2 6 6 6 6 0 01 01 02 01 01 00 00 00 25 Procedure Press PAUSE (Write) button. Press PAUSE (Write) button. Check the data changes to "01". Press PAUSE (Write) button.

Note 3: The adjustment data will be automatically input to page: 7F, address: 00 to 1F. Note 4: If the data is other than "01", adjustment has errors. Contents of error is written into page: 7F, address: 16. See the following table. Data of page: 7F, address: 16 X, Y = 0 X, Y = 2 X, Y = 1

Error contents In the middle of adjustment Abnormal termination Normal termination

3 4 5

"X, Y": X: High 4 bits Yaw sensor Y: Low 4 bits Pitch sensor

HDR-FX1000/FX1000E_ADJ 6-27

RadarW 5. Zoom Ring Adjustment (MR Sensor) The manual zoom ring MR adjustment is carried out automatically.
Subject Measurement Point Measuring Instrument Adjustment Page Adjustment Address Not required Adjusting remote commander 6D A9 to AC, AF 6E FC to FF

RadarW 6. Focus Ring Adjustment (MR Sensor) The manual focus ring MR adjustment is carried out automatically.
Subject Measurement Point Measuring Instrument Adjustment Page Adjustment Address Not required Adjusting remote commander 6D A5 to A8, AD to AF 6E FA, FB

Note 1: Perform the adjustment with the lens in horizontal state. Note 2: If reading/writing data on pages 6D, 6E, set data: 06 to page: 0, address: 10, and then select pages D, E. By this data setting, the pages 6D, 6E can be selected. After the data reading/writing finished, return the data on page: 0, address: 10 to "00". Switch setting 1) POWER ......................................................... CAMERA mode Adjusting method: Order Page Address Data 1 2 0 6 01 02 01 Check the data is "00". (Note 3) Turn the zoom ring manually in one direction slowly. It should be turning several times. Continue to turn till the end of adjustment. 6 6 6 01 02 0C 5B Press PAUSE (Write) button. (Note 4) Check the data changes to "01". Wait for 10 seconds. Check the data is "00". Procedure

Note 1: Perform the adjustment with the lens in horizontal state. Note 2: If reading/writing data on pages 6D, 6E, set data: 06 to page: 0, address: 10, and then select pages D, F. By this data setting, the pages 6D, 6E can be selected. After the data reading/writing finished, return the data on page: 0, address: 10 to "00". Switch setting 1) POWER ......................................................... CAMERA mode Adjusting method: Order Page Address Data 1 2 0 6 01 02 01 Check the data is "00". (Note 3) Turn the focus ring manually in one direction slowly. It should be turning several times. Continue to turn till the end of adjustment. 6 6 6 01 02 0C 59 Press PAUSE (Write) button. (Note 4) Check the data changes to "01". Wait for 10 seconds. Check the data is "00". Procedure

3

3

4 5 6 7

4 5 6 7

Note 3: If not, select page: 6, address: 01, set data: 00, and press the PAUSE (Write) button. Note 4: The adjustment data will be automatically input to page: 6D, address: A9 to AC, AF and page: 6E, address: FC to FF. Processing after Completing Adjustment: Order Page Address Data 1 2 6 0 01 01 00 00 Procedure Press PAUSE (Write) button.

Note 3: If not, select page: 6, address: 01, set data: 00, and press the PAUSE (Write) button. Note 4: The adjustment data will be automatically input to page: 6D, address: A5 to A8, AD to AF and page: 6E, address: FA, FB. Processing after Completing Adjustment: Order Page Address Data 1 2 6 0 01 01 00 00 Procedure Press PAUSE (Write) button.

HDR-FX1000/FX1000E_ADJ 6-28

7. Flange Back Adjustment (Using the minipattern box or flange back adjustment jig) [Preparation (Using the minipattern box)] 1) The minipattern box is installed as shown in the following figure. Note: The attachment lenses are not used. 2) Install the minipattern box so that the distance between it and the front of lens of camera is less than 3 cm. 3) Make the height of minipattern box and the camera equal. 4) Check the output voltage of the regulated power supply is the specified voltage ± 0.01 Vdc. 5) Check that the center of Siemens star chart meets the center of shot image screen with the zoom lens at TELE end and WIDE end respectively. Specified voltage: The specified voltage varies according to the minipattern box, so adjustment the power supply output voltage to the specified voltage written on the sheet which is supplied with the minipattern box.
Below 3 cm Minipattern box Camera

7-1. Flange Back Adjustment RadarW (Using the minipattern box or flange back adjustment jig) Perform the flange back adjustment. In whichever case, the focus will be deviated durin