Text preview for : SONY DSC-S600 SECTION 6 ADJUSTMENTS AUTO-ADJ VER 1.1 2007.08 (9-876-922-52).pdf part of SONY DSC-S600 SONY DSC-S600
DIGITAL STILL CAMERA.
SECTION 6 ADJUSTMENTS AUTO-ADJ VERSION 1.1 2007.08
PART#(9-876-922-52)
Back to : SONY DSC-S600 SECTION 6 A | Home
DSC-S600
Ver 1.1 2007.08 SECTION 6 Auto-ADJ
Revision History ADJUSTMENTS
Link
Before starting adjustments SERVICE MODE
Adjusting items when replacing main parts and boards SERVICE MODE
List of service tools
CAMERA SECTION ADJUSTMENTS
PREPARATIONS BEFORE ADJUSTMENTS
ADJUSTMENT PROGRAMS
CAMERA SYSTEM ADJUSTMENTS
LCD SYSTEM ADJUSTMENTS
ERROR
INITIALIZATION OF DATA
· Use this Service Manual together with the Automatic Adjustment Program (DSC-S600 Auto-Adj Ver_1.1r03.exe).
· Precaution on Replacing the SY-145 board
2007H0500-1
DSC-S600_ADJ © 2007.8
9-876-922-51 Sony EMCS Co. Published by Kohda TEC
TABLE OF CONTENTS
Section Title Page
6. ADJUSTMENTS
Before Starting Adjustment ······················································· 6-1
1-1. Adjusting Items When Replacing
Main Parts and Boards ···················································· 6-3
1-2. List of Service Tools ························································ 6-4
6-1. Camera Section Adjustments ··········································· 6-5
1-1. Preparations Before Adjustments ···································· 6-5
1-2. Adjustment Programs ······················································ 6-9
1-3. Camera System Adjustments ········································· 6-10
1-4. LCD System Adjustments ············································· 6-16
1-5. Error ··············································································· 6-18
1-6. Initialization of Data ······················································ 6-20
6-2. Service Mode ································································· 6-21
DSC-S600_ADJ
--2--
SECTION 6
ADJUSTMENTS
Before starting adjustment
Precaution on Replacing the SY-145 board
· The Repair Board has already been adjusted. Re-initialization or EVR data copy from the set before repair is not
required.
· Perform "Initial Language Data Check" mentioned below, and also the adjustment items necessary after SY Board
replacement.
Initial Language Data Check
If the SY-145 board was replaced, initial language setting may be changed. Accordingly, change the following data so
as to set same initial language as that of the set distributing in each region.
Initial language: Language displayed at the next starting if the setting of Setup menu was reset.
It is different from the language setting selectable with the menu.
Initial Language Data
Page Address Data Language GP2 GP3 GP4
00 English z z z
04 Spanish z z
06 Portugal z
4F 8C 08 Simplified Chinese z
0B Russian z
0D Korean z
Note: GP2 is fixed to English.
GP3 is either English, Spanish, or Russian.
GP4 is either English, Spanish, Portugal, Simplified Chinese, or Korean.
Writing Method:
1) Select page: 00, address: 01 and set data: 01.
2) Select page: 4F, address: 8C, and set the Initial Language Data.
3) Select page: 40, address: 38, and set data: 00.
4) Click [Save] on the SEUS screen.
5) Select page: 80, address: 34, and check that the data is "00".
6) Select page: 80, address: 30, and check that the data is "00".
7) Select page: 00, address: 01, and set data: 00.
8) Turn off the camera.
9) Turn on the camera. Execute "Initialize" of Setup screen.
10) Check the language displayed when the camera starts.
DSC-S600_ADJ
6-1
Method for Copying or Erasing the Data in Internal Memory
The data can be copied/erased by the operations on the Setup screen. (When erasing the data, execute formatting the
internal memory.)
Note 1: When replacing the SY-145 board, erase the data in internal memory of the board before replacement.
Note 2: When replacing the SY-145 board or the IC203 on the SY-145 board, execute formatting and initialize the
internal memory after replacement.
Method for copying the data in internal memory
Copy
Copies all images in the internal memory to a "Memory Stick Duo".
OK See the following procedure.
Cancel Cancels the copying.
1 Insert a "Memory Stick Duo" having 32 MB or larger capacity.
2 Select [OK] with v on the control button, then press z.
The message "All data in internal memory will be copied Ready?" appears.
3 Select [OK] with v, then press z.
Copying starts.
· Use batteries with enough capacity or the AC Adaptor (not supplied). If you attempt to copy image files
using batteries with little remaining capacity, the batteries may run out, causing copying to fail or possibly
corrupting the data.
· You cannot copy individual images.
· The original images in the internal memory are retained even after copying. To delete the contents of the
internal memory, remove the "Memory Stick Duo" after copying, then execute the [Format] command in
(Internal Memory Tool).
· You cannot select a folder copied on a "Memory Stick Duo".
· Even if you copy data, a (Print order) mark is not copied.
8
Method for formatting the internal memory
This item does not appear when a "Memory Stick Duo" is inserted in the camera.
The default settings are marked with .
Format
Formats the internal memory.
· Note that formatting irrevocably erases all data in the internal memory, including even protected images.
OK See the following procedure.
Cancel Cancels the formatting.
1 Select [OK] with v on the control button, then press z.
The message "All data in internal memory will be erased Ready?" appears.
2 Select [OK] with v, then press z.
The format is complete.
DSC-S600_ADJ
6-2
1-1. Adjusting items when replacing main parts and boards
When replacing main parts and boards, adjust the items indicated by z in the following table.
Note 1: The automatic Adjustment Program does not support the "Initialization of data". Perform it manually.
Note 2: When replacing the SY-145 board, erase the data in internal memory of the board before replacement.
Note 3: When replacing the SY-145 board or the IC203 on the SY-145 board, execute formatting and initialize the internal memory
after replacement.
Note 4: When replacing the SY-145 board, perform "Initial Language Data Check" after replacement.
Replaced parts
Block Mounted parts Board
replacement replacement replacement
(Timing gen., CCD signal process)
Lens block (Including CD-606 flexible board and CCD imager)
(Internal memory) (Note 3)
AF illumination LED
(COMPLETE) (Note 2, 3, 4)
LCD unit
Adjusting item Adjustment
LCD901
LED901
IC301
IC203
SY-145 board
SY-145 board
SY-145 board
LCD block
Flash unit
LED
CAMERA adjustment 1 Flange back adj. z z
CAMERA adjustment 2 Flange back check z z
F No. compensation
Measure gain adj.
Mechanical shutter adj.
Light value adj.
AWB 3200K-5800K standard data input
CAMERA adjustment 3 z z z
AWB 3200K-5800K check
Color reproduction adj. & check
CCD linearity check
CCD white defect compensation check
CCD black defect compensation check
CAMERA adjustment 4 Strobe adj. z z z z
CAMERA adjustment 5 Auto focus illumination check z z
V-COM adj.
LCD adjustment z z
White Balance adj.
(Note 1) Initialization of data
Table 6-1-1
DSC-S600_ADJ
6-3
1-2. List of service tools
J-1 J-2 J-3
HASP key and application
for adjustment (SEUS)
Personal computer USB cable
(Note 1) 1-827-038-11
Contact our service headquater of each area
how to get the application for adjustment
(SEUS) and HASP key.
J-4 J-5 J-6
Clear chart
Pattern box PTB-450
9 colors chart (Note 2)
J-6082-200-A
For PTB-450:
or
For PTB-1450: J-6080-621-A
Small pattern box
J-6082-562-A
PTB-1450
For PTB-1450:
J-6082-557-A
J-6082-560-A
J-7 J-8 J-9
Flange back
Minipattern box adjustment jig Siemens star chart
J-6082-353-B J-6082-563-A J-6080-875-A
J-10 J-11 J-12
Connection cord AC power adaptor
Back ground paper DK-2AA AC-LS5
J-2501-130-A 1-830-351-11 1-479-284-12
Fig. 6-1-1
Note 1: Personal computer
OS: Windows98/98SE/Me/2000/XP Home/XP Pro
RAM: 256MB or more recommended
USB: 2.0 recommended (also compatible with 1.1)
Two connectors are required.
Note 2: In using the 9 colors chart on the pattern box PTB-450, adjust the chart size through the procedure shown below so that it matches
to the pattern box PTB-450.
1) Prepare a woody board A of the thickness 5 mm, and paint it mat-black.
2) Fit the 9 colors chart in the woody board A, and secure the chart with a black tape, etc. to shield the light.
woody boad A
woody boad A
360 mm
155 mm
135 mm 280 mm
9 colors chart
Fig. 6-1-2
DSC-S600_ADJ
6-4
6-1. CAMERA SECTION ADJUSTMENTS
1-1. PREPARATIONS BEFORE ADJUSTMENTS
1-1-1. Preparations
L = About 9 cm
1) Connect the equipment for adjustments according to Fig. 6-1-4.
2) Start up the application for adjustment (SEUS).
Pattern box
Front of the lens
Note: Before perform the adjustment, set the following data.
1) Select page: 40, address: 38 and set data: 00. L Camera
Fig. 6-1-3
Insert the connection cord
DK-2AA (1-830-351-11).
AC power adaptor
AC-LS5
(1-479-284-12)
AC IN
PC (The SEUS must be installed in the PC.)
OS: Windows 98/98SE/Me/2000/XP
RAM: 256MB or more recommended To USB
USB: 2.0 recommended (also compatible with 1.1) connector
Two connectors are required.
USB cable
To USB connector
(1-827-038-11)
HASP Key
To USB connector
Fig. 6-1-4
DSC-S600_ADJ
6-5
1-1-3. Precautions
1. Setting the Switch
Unless otherwise specified, set the switches as follows and per-
form adjustments.
1. Mode switch ....................................... CAMERA
2. ZOOM switch .................................... WIDE end
3. Digital Zoom (SET UP setting) ......... Off
4. Camera (Menu items) ........................ Auto
9 colors chart (Standard picture frame)
A B A
A=B
C
B
C=
Green Yellow W14 3
C14: Filter for AWB 5800K adjustment
Cyan White Red B
C14 Blue Magenta
C
Adjust the camera position and direction
A to obtain the LCD screen shown in Fig. a.
Effective picture frame 2 Transparent window
Fig. a (LCD screen)
Fig. 6-1-5
2. Subjects
1) 9 colors chart (Standard picture frame).
When performing adjustments using the 9 colors chart, adjust
the picture frame as shown in Fig. 6-1-5. (Standard picture
frame)
2) Clear chart (Standard picture frame)
Remove the 9 colors chart from the pattern box and insert a
clear chart in its place. (Do not perform zoom operations dur-
ing this time)
DSC-S600_ADJ
6-6
3. Preparing the Flash Adjustment Box
A dark room is required to provide an accurate flash adjustment.
If it is not available, prepare the flash adjustment box as given
below;
1) Provide woody board A, B and C of 15 mm thickness.
woody board A (2) woody board B (2) woody board C (1)
400 mm 370 mm 700 mm
513 mm 513 mm 700 mm
730 mm 700 mm
Fig. 6-1-6
2) Apply black mat paint to one side of woody board A and B.
3) Attach background paper (J-2501-130-A) to woody board C.
4) Assemble so that the black sides and the background paper
side of woody board A, B and C are internal. (Fig. 6-1-7)
woody board A
woody board B
woody board A
woody board B
woody board C
Fig. 6-1-7
DSC-S600_ADJ
6-7
1-1-3. Using Method of SEUS 2. Operation
The application for adjustment (SEUS) is used to change the coef- · Page change
ficient for calculating the signal processing or EVR data. The SEUS To change the page, click [Page] on the SEUS screen and enter
performs two-way communication between PC and set through the page to be changed. The page is displayed in hexadecimal
the USB terminal. The two-way communication result data can be notation.
written to the nonvolatile memory.
· Address change
1. Connection To change the address, click [Address] on the SEUS screen and
1) Connect the HASP key to the USB terminal of the PC. enter the address to be changed. The address is displayed in
2) Connect the PC and set with the USB cable. hexadecimal notation.
3) Confirm that the set starts in the USB mode.
4) Start the SEUS on the PC. · Data change
5) Click [Connect] on the SEUS screen. If the connection is nor- To change the data, click [Set] on the SEUS screen and enter the
mal, the SEUS screen will be as shown in Fig. 6-1-8, indicat- data. The data is displayed in hexadecimal notation.
ing the "connected" state. This operation does not write the data to the nonvolatile memory.
Note: The SEUS will go in "disconnect" state, if the set is
turned off (for instance, by resetting the set). In such a · Data saving
case, click [Connect] on the SEUS screen to restore the To write the all changed data to the nonvolatile memory, click
"connected" state. [Save] on the SEUS screen and wait for more than 3 sec.
· Data reading
The data displayed on the SEUS screen are the data values at
the time when the pages and addresses were set, and they are
not updated automatically. To check the data change, click [Read]
on the SEUS screen and update the displayed data.
1-1-5. Precaution on Use of SEUS
Wrong SEUS operation could clear correct adjustment data. To
prevent the data clear by mistake, it is recommended to save all
adjustment data by clicking [Page Edit] on the SEUS screen before
starting the adjustment.
Saving Method:
1) Click [Page Edit] on the SEUS screen to display the SEUS
PAGE EDIT screen.
2) Click [Page], and enter the page number to be saved.
3) Click [Read] to read the data to be saved from the camera.
4) Click [File] and save the data to PC.
Loading Method:
1) Select page: 00, address: 01 and set data: 01.
Fig. 6-1-8 2) Click [Page Edit] on the SEUS screen to display the SEUS PAGE
EDIT screen.
3) Click [File] and load the data from PC.
4) Click [Write] on the SEUS PAGE EDIT screen.
5) Click [Close] to close the SEUS PAGE EDIT screen.
6) Select page: 40, address: 38 and set data: 00.
7) Click [Save] on the SEUS screen.
8) Select page: 80, address: 34, and check that the data is "00".
9) Select page: 80, address: 30, and check that the data is "00".
10) Select page: 00, address: 01 and set data: 00.
DSC-S600_ADJ
6-8
1-2. ADJUSTMENT PROGRAMS 3. Function of Each Button on Main Menu Screen
The DSC-S600 is adjusted with the Automatic Adjustment Program. When the Automatic Adjustment Program started, the Main Menu
The Automatic Adjustment Program automatically controls the ad- screen in Fig. 6-1-9 will appear. On this screen, select each adjust-
justment operations that were formerly entered manually on the op- ment section.
eration screen of the SEUS (some adjustments may be manually op-
erated on the SEUS operation screen).
1-2-1. Automatic Adjustment Program
1. Precautions When Using Automatic Adjustment
5 1
Program
1) The Automatic Adjustment Program writes the adjustment re-
sults such as EVR data to the set through two-way communi- 2
cation with the camera via the SEUS. Accordingly, the Auto-
matic Adjustment Program must be used in the environment 3
where the SEUS operates.
2) The program run time may vary depending on the environ-
4
ment of the personal computer used.
3) The SEUS must be already started on the PC when using the
Automatic Adjustment Program. With the SEUS not started, Fig. 6-1-9
some adjustment items will take time in adjustment.
1 [Connecting the Equipment] button
2. Start of Automatic Adjustment Program A connection diagram of the equipment is displayed.
Double-click the application file (DSC-S600 Auto-Adj
Ver_1.[]r[][].exe), and the Automatic Adjustment Program will start. 2 [CAMERA SYSTEM ADJUSTMENT] button
Note: [] (numeric value) of the file name varies depending on the The "CAMERA SYSTEM ADJUSTMENT" screen appears.
version of Automatic Adjustment Program.
3 [LCD SYSTEM ADJUSTMENT] button
The "LCD SYSTEM ADJUSTMENT" screen appears.
4 [END] button
The Automatic Adjustment Program finishes.
5 This part indicates the version of Automatic Adjustment Pro-
gram.
DSC-S600_ADJ
6-9
1-3. CAMERA SYSTEM ADJUSTMENTS
1-3-1. Function of Each Button on Camera System
Adjustment Screen
Click the [CAMERA SYSTEM ADJUSTMENT] button on the Main
Menu screen, and the "CAMERA SYSTEM ADJUSTMENT"
screen in Fig. 6-1-10 will appear.
1
2
3
4
5
Fig. 6-1-10
1 [To Menu] button
The Main Menu screen comes back.
2 [Preparation] button
Notes for adjustment or jigs used are displayed.
3 [Start] button
Each adjustment from "Camera Adjustment 1" to "Camera
Adjustment 5" starts.
4 [Reset] button
This button functions same as the "Initialize" of the setup
screen.
5 [Release Data Setting] button
The data setting at the adjustment is cancelled.
During the data setting, the button color changes from "white"
to "red". When the data setting is cancelled, the button color
returns to "white".
(Use this button when an error occurred in the camera adjust-
ment 1-5. If the adjustment completed successfully, the data
setting is automatically cancelled and the button color returns
to "white".)
DSC-S600_ADJ
6-10
1-3-2. Adjustment Items of Camera System Adjust-
ment
The adjustment items of camera system adjustment are as listed in
Table 6-1-2. The Automatic Adjustment Program divides the ad-
justment items into five, camera adjustment 1-5. Clicking either
CAMERA Adjustment Start button allows the adjustment item
which corresponds to that button to be executed.
The adjustment conditions of the subject and filter vary depend-
ing on which item is adjusted. The Adjustment Program displays
an instruction for the subject and filter as a message during the
adjustment.
Adjustment Adjustment
Button Name Adjustment Subject
Page Address
Siemens star chart with ND filter B0 to B7, C0 to C7
6D
CAMERA Adjustment 1 Flange Back Adj. for minipattern box (Note) or D0 to DB, E1 to F2
Flange back adjustment jig 6F 18 to 53
Siemens star
CAMERA Adjustment 2 Flange Back Check (1.0m from front the lens)
(Luminance: 200 to 400 lux)
F No. Compensation 6F 60, 6B to 6D
Measure Gain Adj. 6F 6B, 6F
Clear chart
(Standard picture frame) 6B to 6D, B8 to BB,
Mechanical Shutter Adj. 6F
C7, C8
Light Value Adj. 6F 65 to 67
AWB 3200K-5800K
6E 00 to 21, 24 to 49
Standard Data Input
CAMERA Adjustment 3
AWB 3200K-5800K Check 9 color chart
(Standard picture frame)
Color Reproduction
Adj. & Check 6E 60 to 67
CCD Linearity Check
CCD White Defect
Compensation Check Clear chart
(Standard picture frame)
CCD Black Defect
Compensation Check
6E 72 to 75
CAMERA Adjustment 4 Strobe Adj. Flash adjustment box (50 cm)
6F D8 to EF
6D B8 to BF
CAMERA Adjustment 5 Auto focus illumination Check Flash adjustment box (50 cm)
6F 10 to 15
Note: Dark Siemens star chart.
Table 6-1-2
DSC-S600_ADJ
6-11
1-3-3. Adjusting Method Preparation of Flange Back Adj.
1. CAMERA Adjustment 1 (Using the minipattern box)
[Automatic Adjustment Program execution items and 1) The minipattern box is installed as shown in the following fig-
sequence] ure.
1. Data Setting during Camera Adj. Note 1: The attachment lenses are not used.
2. Flange Back Adj. Note 2: Take care not to hit the mini-pattern box when ex-
3. Release of Data Setting during Camera Adj. tending the lens.
2) Install the minipattern box so that the distance between it and
[Adjusting method] the front of lens of camera is less than 3 cm.
1) Click the [Start] button of the CAMERA Adjustment 1. 3) Make the height of minipattern box and the camera equal.
2) The Automatic Adjustment Program executes "1. Data Setting 4) Check the output voltage of the regulated power supply is the
during Camera Adj.". specified voltage ± 0.01 Vdc.
3) Upon successful completion of the "1. Data Setting during 5) Check that the center of Siemens star chart meets the center of
Camera Adj.", the following message is displayed. Set the sub- shot image screen with the zoom lens at TELE end and WIDE
ject by referring to "Preparation of Flange Back Adj.". end respectively.
Specified voltage: The specified voltage varies according to the
minipattern box, so adjustment the power sup-
ply output voltage to the specified voltage writ-
ten on the sheet which is supplied with the
minipattern box.
Below 3 cm
Fig. 6-1-11 Minipattern box
4) If the [OK] button is clicked, "2. Flange Back Adj." and "3. Camera
Release of Data Setting during Camera Adj." will be executed.
5) Upon successful completion of all items of the CAMERA
Adjustment 1, the following message is displayed. Click the
[OK] button.
Regulated power supply
Output voltage : Specified voltage ± 0.01 Vdc
Output current : more than 3.5 A
Red (+)
Black ()
Fig. 6-1-12 Yellow (SENS +)
White (SENS ) Need not connected
Black (GND)
Fig. 6-1-13
Preparation of Flange Back Adj.
(Using the flange back adjustment jig)
(Luminance: about 300 lux)
1) Install the flange back adjustment jig so that the distance be-
tween it and the front of lens of camera is less than 3 cm.
Note 3: Take care not to hit the flange back adjustment jig
when extending the lens.
2) Make the height of flange back adjustment jig and the camera
equal.
3) Check that the center of chart meets the center of shot image
screen with the zoom lens at TELE end and WIDE end respec-
tively.
Below 3 cm
Flange back adjustment jig
Camera
Fig. 6-1-14
DSC-S600_ADJ
6-12
2. CAMERA Adjustment 2 3. CAMERA Adjustment 3
[Automatic Adjustment Program execution items and [Automatic Adjustment Program execution items and
sequence] sequence]
1. Data Setting during Camera Adj. 1. Data Setting during Camera Adj.
2. Flange Back Check 2. Picture Frame Setting
3. Release of Data Setting during Camera Adj. 3. F No. Compensation
4. Measure Gain Adj.
[Adjusting method] 5. Mechanical Shutter Adj.
1) Click the [Start] button of the CAMERA Adjustment 2. 6. Light Value Adj.
2) The Automatic Adjustment Program executes "1. Data Setting 7. AWB 3200K-5800K Standard Data Input
during Camera Adj.". 8. AWB 3200K-5800K Check
3) Upon successful completion of the "1. Data Setting during 9. Color Reproduction Adj. & Check
Camera Adj.", the following message is displayed. Set the sub- 10. CCD Linearity Check
ject in accordance with the message. 11. CCD White Defect Compensation Check
12. CCD Black Defect Compensation Check
13. Release of Data Setting during Camera Adj.
[Adjusting method]
1) Click the [Start] button of the CAMERA Adjustment 3.
2) The Automatic Adjustment Program executes the "1. Data Set-
ting during Camera Adj.".
3) Upon successful completion of "1. Data Setting during Cam-
era Adj.", "2. Picture Frame Setting" is executed. The follow-
Fig. 6-1-15 ing message is displayed, and then referring to Fig. 6-1-19, set
the subject and click the [OK] button.
4) Click the [OK] button is clicked, "2. Flange Back Check" is
executed. The following messages are displayed, and then op-
erate the camera to make a check in accordance with the mes-
sages.
Fig. 6-1-18
Check on the LCD screen
B
A=B C=
3
C14: Filter for AWB 5800K adjustment
A B A
C
Green Yellow W14
Fig. 6-1-16
Cyan White Red B
5) Upon completion of "2. Flange Back Check", "3. Release of
Data Setting during Camera Adj." is executed.
C14 Blue Magenta
6) Upon successful completion of all items of the CAMERA
Adjustment 2, the following message is displayed. Click the C
[OK] button.
A
Effective picture frame
2
Transparent window
Fig. 6-1-19
Fig. 6-1-17
DSC-S600_ADJ
6-13
After that, the next message is displayed. Then, change the chart At this time, the following message is displayed, and click the
in accordance with the message. [Yes] button if the check result display at the upper right of
Color Reproduction Check screen is OK, or the [No] button if
NG.
Fig. 6-1-20
4) Click the [OK] button, and the items from "3. F No. Compen- Fig. 6-1-23
sation" to "6. Light Value Adj." will be executed.
5) Upon successful completion of "6. Light Value Adj.", the fol- 8) Upon successful completion of "9. Color Reproduction Adj.
lowing message is displayed. Change the chart in accordance & Check", the following message is displayed. Change the
with the message. chart in accordance with the message.
Fig. 6-1-21
Fig. 6-1-24
6) Click the [OK] button, and the "7. AWB 3200K-5800K Stan-
dard Data Input" and "8. AWB 3200K-5800K Check" will be 9) Click the [OK] button, and the items from "10. CCD Linearity
executed. Check" to "13. Release of Data Setting during Camera Adj."
7) After that, "9. Color Reproduction Adj. & Check" will be ex- will be executed.
ecuted. Upon completion of adjustment, the check result is 10) Upon successful completion of all items of the CAMERA
displayed on the Color Reproduction Check screen. Adjustment 3, the following message is displayed. Click the
[OK] button.
Fig. 6-1-25
Fig. 6-1-22
DSC-S600_ADJ
6-14
9. CAMERA Adjustment 4 10. CAMERA Adjustment 5
Note: "CAMERA Adjustment 4" is available only once after the [Automatic Adjustment Program execution items and
power is turned on. If the adjustment is retried, turn off the sequence]
power and turn on again. 1. Data Setting during Camera Adj.
2. Auto Focus Illumination Check
[Automatic Adjustment Program execution items and 3. Release of Data Setting during Camera Adj.
sequence]
1. Data Setting during Camera Adj. [Adjusting method]
2. Strobe Adj. 1) Click the [Start] button of CAMERA Adjustment 5.
3. Release of Data Setting during Camera Adj. 2) The Automatic Adjustment Program executes the "1. Data
Setting during Camera Adj.".
[Adjusting method] 3) Upon successful completion of the "1. Data Setting during
1) Click the [Start] button of CAMERA Adjustment 4. Camera Adj.", the following message is displayed. Set the sub-
2) The Automatic Adjustment Program executes the "1. Data ject in accordance with the message.
Setting during Camera Adj.". (For the Flash adjustment box, refer to "3. Preparing the Flash
3) Upon successful completion of the "1. Data Setting during Adjustment Box" (see page 6-7).)
Camera Adj.", the following message is displayed. Set the sub-
ject in accordance with the message.
(For the Flash adjustment box, refer to "3. Preparing the Flash
Adjustment Box" (see page 6-7).)
Fig. 6-1-29
4) Press the [OK] button, and the "2. Auto Focus Illumination
check" will be executed.
Fig. 6-1-26 5) Upon successful completion of the "2. Auto Focus Illumina-
tion Check", the "3. Release of Data Setting during Camera
4) Press the [OK] button, and the "2. Strobe Adj." will be executed. Adj." will be executed successively.
5) During execution of "2. Strobe Adj.", the following message 6) Upon successful completion of all items of the CAMERA
is displayed. After checking the flashing of strobe light, click Adjustment 5, the following message is displayed. Click the
the [OK] button. (This message is displayed 2 times during [OK] button.
execution of adjustment.)
Fig. 6-1-30
Fig. 6-1-27
6) Upon successful completion of "2. Strobe Adj.", "3.Release
of Data Setting during CAMERA Adj." is executed.
7) Upon successful completion of all items of the CAMERA
Adjustment 4, the following message is displayed. Click the
[OK] button.
Fig. 6-1-28
DSC-S600_ADJ
6-15
1-4. LCD SYSTEM ADJUSTMENTS 1-4-2. Adjustment Items of LCD System Adjustment
The adjustment items of LCD system adjustment are as listed in
1-4-1. Function of Each Button on LCD System Table 6-1-3. The Automatic Adjustment Program executes the ad-
Adjustment Screen justment items if the LCD Adjustment Start button is clicked.
Click the [LCD SYSTEM ADJUSTMENT] button on the Main Menu Button
screen, and the "LCD SYSTEM ADJUSTMENT" screen in Fig. Adjustment Signal Page Address
Name
6-1-31 will appear.
LCD V-COM adj. 8F 11
1 Arbitrary
Adjustment White Balance adj. 8F 42, 43
Table 6-1-3
2
3
4
Fig. 6-1-31
1 [To Menu] button
The Main Menu screen comes back.
2 [Start] button
"LCD Adjustment" starts.
3 [Reset] button
This button functions same as the "Initialize" of the setup
screen.
4 [Release Data Setting] button
The data setting at the adjustment is cancelled.
During the data setting, the button color changes from "white"
to "red". When the data setting is cancelled, the button color
returns to "white".
(Use this button when an error occurred in the LCD adjust-
ment. If the adjustment completed successfully, the data set-
ting is automatically cancelled and the button color returns to
"white".)
DSC-S600_ADJ
6-16
1-4-3. Adjusting Method SEUS operation screen
[Automatic Adjustment Program execution items and UP/DOWN key
sequence]
1. Data Setting during LCD Adj. & EVR Data Write
2. V-COM Adj.
3. White Balance Adj.
4. Release of Data Setting during LCD Adj.
[Adjusting method]
1) Click the [Start] button of the LCD Adjustment.
2) The Automatic Adjustment Program executes "1. Data Setting
during LCD Adj. & EVR Data Write"
3) Upon successful completion of the "1. Data setting during LCD
Adj. & EVR Data Write", the following message is displayed
during execution in "2. V-COM Adj. ". On the SEUS screen,
operate the UP/DOWN key so that the brightness of portions
A and B on the LCD panel is equal. After the adjustment, click
the [OK] button.
Fig. 6-1-35
Check on the LCD screen (V-COM Adj.)
A B
Fig. 6-1-32
4) Upon completion of "2. V-COM Adj.", "3. White Balance Adj."
is executed. The following message is displayed, and then check
that LCD screen is not colored. Fig. 6-1-36
If colored, change the data of page: 8F, address: 42 and 43 on
the SEUS Operation screen to adjust so that the LCD screen is
not colored.
Fig. 6-1-33
5) If the [OK] button is clicked, "4. Release of Data Setting dur-
ing LCD Adj." will be executed.
6) Upon successful completion of all item the LCD Adjustment,
the following message is displayed. Click the [OK] button.
Fig. 6-1-34
DSC-S600_ADJ
6-17
1-5. ERROR 3. Adjustment Time Out
In case of an error during the execution of adjustment, the Auto-
matic Adjustment Program interrupts the processing at that point,
and displays an error message, and then terminates the program
execution there.
1-5-1. Error Message This part indicates
the adjustment
When an error message is displayed, perform the remedy given
item in which
below, and then retry adjustment. If the error message is displayed an error occurred.
though the remedy was performed, the circuits will be faulty.
Fig. 6-1-39
1. Connect Error
Symptom Adjustment does not finish within the specified
time.
Cause · Adjustment conditions are wrong.
· Data error exists in the camera.
Remedy · Check that the conditions such as a subject
are correct.
· Reset the camera.
Fig. 6-1-37
4. Adjustment NG
Symptom USB communication with the set is abnormal.
Cause · USB cable is not inserted tightly.
· Power supply is not installed correctly.
· Communication with SEUS is abnormal.
This part indicates
Remedy · Disconnect the USB cable once, and then re