SECTION 6 ADJUSTMENTS

Auto-ADJ

Link
Before starting adjustments
Adjusting items when replacing main parts and boards List of service tools

SERVICE MODE
SERVICE MODE

CAMERA SECTION ADJUSTMENTS
PREPARATIONS BEFORE ADJUSTMENTS ADJUSTMENT PROGRAMS VIDEO SYSTEM ADJUSTMENTS CAMERA SYSTEM ADJUSTMENTS LCD SYSTEM ADJUSTMENTS ERROR INITIALIZATION OF DATA

· Use this Service Manual together with the Automatic Adjustment Program (DSC-W55 Auto-Adj Ver_1.2r03.exe) and the AWB Adjustment Program (W35W55AwbAdjustment.exe). · Precaution on Replacing the SY-176 Board

DSC-W55_ADJ
9-852-160-51

Sony EMCS Co.

2008C0500-1 © 2008.3 Published by Kohda TEC

TABLE OF CONTENTS
Section Title Page

6.

ADJUSTMENTS

Before Starting Adjustments ····················································· 6-1 1-1. Adjusting Items When Replacing Main Parts and Boards ···················································· 6-4 1-2. List of Service Tools ························································ 6-5 6-1. Camera Section Adjustments ··········································· 6-6 1-1. Preparations Before Adjustments ···································· 6-6 1-2. Adjustment Programs ···················································· 6-10 1-3. Video System Adjustments ············································ 6-12 1-4. Camera System Adjustments ········································· 6-14 1-5. LCD System Adjustments ············································· 6-22 1-6. Error ··············································································· 6-24 1-7. Initialization of Data ······················································ 6-26 6-2. Service Mode ································································· 6-27

DSC-W55_ADJ --2--

SECTION 6 ADJUSTMENTS
Before starting adjustments Precaution on Replacing the SY-176 Board
· The Repair Board has already been adjusted. Re-initialization or EVR data copy from the set before repair is not required. · Perform "VIDEO OUT Default Data Check" and "Initial Language Data Check" mentioned below, and also the adjustment items necessary after SY Board replacement.

VIDEO OUT Default Data Check
When you replace to the repairing board, the written data of repairing board also might be changed to original setteing because of broadcast system (NTSC/PAL). When the data has changed because of board replaceing etc., check the default data of VIDEO OUT if destination code is right. If not, rewrite to the right value. VIDEO OUT Default Data Page 4F Address 8D Data NTSC 00 PAL 01

Writing Method: 1) Select page: 00, address: 01, and set data: 01. 2) Select page: 4F, address: 8D, and set data: 00 (NTSC) or data: 01 (PAL). 3) Select page: 40, address: 38, and set data: 00. 4) Click [Save] on the SEUS screen. 5) Select page: 80, address: 34, and check that the data is "00". 6) Select page: 80, address: 30, and check that the data is "00". 7) Select page: 00, address: 01, and set data: 00.

DSC-W55_ADJ 6-1

Initial Language Data Check
If the SY-176 board was replaced, initial language setting may be changed. Accordingly, change the following data so as to set same initial language as that of the set distributing in each region. Initial language: Language displayed at the next starting if the setting of Setup menu was reset. It is different from the language setting selectable with the menu. Initial Language Data Page Address Data 00 04 4F 8C 06 08 0B 0D Language English Spanish Portugal Simplified Chinese Russian Korean z z GP2 z GP3 z z GP4 z z z z

Note: GP2 is fixed to English. GP3 is either English, Spanish, or Russian. GP4 is either English, Spanish, Portugal, Simplified Chinese, or Korean. Writing Method: 1) Select page: 00, address: 01 and set data: 01. 2) Select page: 4F, address: 8C, and set the Initial Language Data. 3) Select page: 40, address: 38, and set data: 00. 4) Click [Save] on the SEUS screen. 5) Select page: 80, address: 34, and check that the data is "00". 6) Select page: 80, address: 30, and check that the data is "00". 7) Select page: 00, address: 01, and set data: 00. 8) Turn off the camera. 9) Turn on the camera. Execute "Initialize" of Setup screen. 10) Check the language displayed when the camera starts.

DSC-W55_ADJ 6-2

Method for Copying or Erasing the Data in Internal Memory
The data can be copied/erased by the operations on the Setup screen. (When erasing the data, execute formatting the internal memory.) Note 1: When replacing the SY-176 board, erase the data in internal memory of the board before replacement. Note 2: When replacing the SY-176 board, execute formatting and initialize the internal memory after replacement.

Method for copying the data in internal memory
Copy
Copies all images in the internal memory to a "Memory Stick Duo".
1 Insert a "Memory Stick Duo" having 64 MB or larger capacity. 2 Select [OK] with v on the control button, then press z. The message "All data in internal memory will be copied Ready?" appears. 3 Select [OK] with v, then press z. Copying starts.

To cancel the copying
Select [Cancel] in step 2 or 3, then press z.
· Use a fully charged battery pack. If you attempt to copy image files using a battery pack with little remaining charge, the battery pack may run out, causing copying to fail or possibly corrupting the data. · You cannot copy individual images. · The original images in the internal memory are retained even after copying. To delete the contents of the internal memory, remove the "Memory Stick Duo" after copying, then execute the [Format] command in (Internal Memory Tool). · When you copy the data in the internal Memory to the "Memory Stick Duo", all the data will be copied. You cannot choose a specific folder on the "Memory Stick Duo" as the destination for the data to be copied. · Even if you copy data, a (Print order) mark is not copied.

Method for formatting the internal memory
This item does not appear when a "Memory Stick Duo" is inserted in the camera.

Format
Formats the internal memory.
· Note that formatting irrevocably erases all data in the internal memory, including even protected images.

1 Select [OK] with v on the control button, then press z. The message "All data in internal memory will be erased Ready?" appears. 2 Select [OK] with v, then press z. The format is complete.

To cancel the formatting
Select [Cancel] in step 1 or 2, then press z.

DSC-W55_ADJ 6-3

1-1. Adjusting items when replacing main parts and boards
When replacing main parts and boards, adjust the items indicated by z in the following table. Note 1: The Automatic Adjustment Program does not support the "Initialization of data". Perform it manually. Note 2: Use the AWB Adjustment Program (W35W55AwbAdjustment.exe). Note 3: When replacing the SY-176 board, erase the data in internal memory of the board before replacement. Note 4: When replacing the SY-176 board, perform "VIDEO OUT Default Data Check" and "Initial Language Data Check" after replacement.
Replaced parts Block replacement Mounted parts Board replacement replacement

CCD block assy (Including CD-604 flexible board and CCD imager)

(CCD signal process, Timing gen.)

(AF illumination LED)

Adjusting item

Adjustment

SY-176 board

SY-176 board

VIDEO adjustment CAMERA adjustment 1 CAMERA adjustment 2

Video output level adj. Flange back adj. Flange back check Color shade adj. & check F No. compensation

z z z z z

z z z

CAMERA adjustment 3

Measure gain adj. Mechanical shutter adj. Light value adj.

z z

z

z

(Note 2)

AWB 3200K-5800K standard data input Color reproduction adj. & check

z

z

z

CAMERA adjustment 4

CCD linearity check CCD white defect compensation check CCD black defect compensation check

z

z

CAMERA adjustment 5 CAMERA adjustment 6 LCD adjustment (Note 1)

Strobe adj. Auto focus illumination check V-COM adj. White Balance adj. Initialization of data

z z z z z

z

z z

z z z

Table 6-1-1

DSC-W55_ADJ 6-4

SY-176 board

ST-133 board

ST-133 board

LCD block

LCD block

Lens block

Flash unit

(COMPLETE) (Note 3, 4)

Backlight unit

(Video amp.) IC602

LCD unit

(COMPLETE)

LCD901

IC301

D901

D003

1-2. List of service tools
· Oscilloscope J-1 Personal computer (Note 1) · Color monitor J-2 HASP key and application for adjustment (SEUS) J-3

Contact our service headquater of each area how to get the application for adjustment (SEUS) and HASP key. J-5 9 colors chart (Note 2) For PTB-1450: J-6082-562-A J-6

USB, A/V, DC IN cable for multi-use terminal 1-830-848-21 Clear chart For PTB-450: J-6080-621-A For PTB-1450: J-6082-560-A

J-4

Pattern box PTB-450 J-6082-200-A or Small pattern box PTB-1450 J-6082-557-A

J-7 Minipattern box J-6082-353-B

J-8 Flange back adjustment jig J-6082-563-A

J-9 Siemens star chart J-6080-875-A

J-10 Back ground paper J-2501-130-A

J-11 AC power adaptor AC-LS5 1-479-284-51

J-12 Tripod Adaptor J-6082-577-A

J-13

Camera table J-6082-384-A

Fig. 6-1-1
Note 1: Personal computer OS: Windows98/98SE/Me/2000/XP Home/XP Pro RAM: 256MB or more recommended USB: 2.0 recommended (also compatible with 1.1) Two connectors are required. Note 2: In using the 9 colors chart on the pattern box PTB-450, adjust the chart size through the procedure shown below so that it matches to the pattern box PTB-450. 1) Prepare a woody board A of the thickness 5 mm, and paint it mat-black. 2) Fit the 9 colors chart in the woody board A, and secure the chart with a black tape, etc. to shield the light.
woody boad A 360 mm 155 mm woody boad A

135 mm 280 mm

9 colors chart

Fig. 6-1-2

DSC-W55_ADJ 6-5

6-1. CAMERA SECTION ADJUSTMENTS
1-1. PREPARATIONS BEFORE ADJUSTMENTS
L = About 11 cm Pattern box

1-1-1. Preparations 1) Connect the equipment for adjustments according to Fig. 6-1-4. 2) Start up the application for adjustment (SEUS). Note: Before perform the adjustment, set the following data. 1) Select page: 40, address: 38 and set data: 00.

Front of the lens L Camera

Fig. 6-1-3

PC (The SEUS must be installed in the PC.) OS: Windows 98/98SE/Me/2000/XP RAM: 256MB or more recommended USB: 2.0 recommended (also compatible with 1.1) Two connectors are required.

DISP SEL switch setting TV: Video/Camera System Adjustment CAMERA: LCD/Control System Adjustment

To Multi connector

HASP Key
AC power adaptor AC-LS5 (1-479-284-51) AC IN

To USB connector Video system Adjustment Osilloscope Terminated 75 Color monitor USB, A/V, DC IN cable for multi-use terminal (1-830-848-21) Video (yellow) Audio (Black)

To DC IN jack

Fig. 6-1-4

DSC-W55_ADJ 6-6

1-1-2. Precautions 1. Setting the Switch Unless otherwise specified, set the switches as follows and perform adjustments. 1. Mode dial ........................................... CAMERA (Auto) 2. ZOOM lever ....................................... WIDE end 3. Digital Zoom (SET UP setting) ......... Off 9 colors chart (Standard picture frame)
A B A C Green Yellow W14 A=B C= B
3

Cyan

White

Red

B

C14: Filter for AWB 5800K adjustment

C14

Blue

Magenta C

Effective picture frame

A 2

Transparent window

Adjust the camera position and direction to obtain the LCD screen or the monitor TV display shown in Fig. a.

Fig. a LCD screen or under scan monitor TV picture

Fig. 6-1-5
2. Subjects 1) 9 colors chart (Standard picture frame). When performing adjustments using the 9 colors chart, adjust the picture frame as shown in Fig. 6-1-5. (Standard picture frame) 2) Clear chart (Standard picture frame) Remove the 9 colors chart from the pattern box and insert a clear chart in its place. (Do not perform zoom operations during this time)

DSC-W55_ADJ 6-7

3. Preparing the Flash Adjustment Box A dark room is required to provide an accurate flash adjustment. If it is not available, prepare the flash adjustment box as given below; 1) Provide woody board A, B and C of 15 mm thickness.
woody board A (2) 400 mm woody board B (2) 370 mm woody board C (1) 700 mm

513 mm

513 mm

700 mm

730 mm

700 mm

Fig. 6-1-6

2) Apply black mat paint to one side of woody board A and B. 3) Attach background paper (J-2501-130-A) to woody board C. 4) Assemble so that the black sides and the background paper side of woody board A, B and C are internal. (Fig. 6-1-7)
woody board A

woody board B

woody board A

woody board B woody board C

Fig. 6-1-7

L = 50cm

Flash adjustment box

Front of the lens

L

Camera

Background paper

Fig. 6-1-8

DSC-W55_ADJ 6-8

1-1-3.

Using Method of SEUS

The application for adjustment (SEUS) is used to change the coefficient for calculating the signal processing or EVR data. The SEUS performs two-way communication between PC and set through the USB terminal. The two-way communication result data can be written to the nonvolatile memory. 1. 1) 2) 3) 4) 5) Connection Connect the HASP key to the USB terminal of the PC. Connect the PC and set with the USB cable. Confirm that the set starts in the USB mode. Start the SEUS on the PC. Click [Connect] on the SEUS screen. If the connection is normal, the SEUS screen will be as shown in Fig. 6-1-9, indicating the "connected" state. Note: The SEUS will go in "disconnect" state, if the set is turned off (for instance, by resetting the set). In such a case, click [Connect] on the SEUS screen to restore the "connected" state.

2. Operation · Page change To change the page, click [Page] on the SEUS screen and enter the page to be changed. The page is displayed in hexadecimal notation. · Address change To change the address, click [Address] on the SEUS screen and enter the address to be changed. The address is displayed in hexadecimal notation. · Data change To change the data, click [Set] on the SEUS screen and enter the data. The data is displayed in hexadecimal notation. This operation does not write the data to the nonvolatile memory. · Data saving To write the all changed data to the nonvolatile memory, click [Save] on the SEUS screen and wait for more than 3 sec. · Data reading The data displayed on the SEUS screen are the data values at the time when the pages and addresses were set, and they are not updated automatically. To check the data change, click [Read] on the SEUS screen and update the displayed data. 1-1-4. Precaution on Use of SEUS Wrong SEUS operation could clear correct adjustment data. To prevent the data clear by mistake, it is recommended to save all adjustment data by clicking [Page Edit] on the SEUS screen before starting the adjustment. Saving Method: 1) Click [Page Edit] on the SEUS screen to display the SEUS PAGE EDIT screen. 2) Click [Page], and enter the page number to be saved. 3) Click [Read] to read the data to be saved from the camera. 4) Click [File] and save the data to PC. Loading Method: 1) Select page: 00, address: 01 and set data: 01. 2) Click [Page Edit] on the SEUS screen to display the SEUS PAGE EDIT screen. 3) Click [File] and load the data from PC. 4) Click [Write] on the SEUS PAGE EDIT screen. 5) Click [Close] to close the SEUS PAGE EDIT screen. 6) Select page: 40, address: 38 and set data: 00. 7) Click [Save] on the SEUS screen. 8) Select page: 80, address: 34, and check that the data is "00". 9) Select page: 80, address: 30, and check that the data is "00". 10) Select page: 00, address: 01 and set data: 00.

Fig. 6-1-9

DSC-W55_ADJ 6-9

1-2.

ADJUSTMENT PROGRAMS

The DSC-W55 is adjusted with the Automatic Adjustment Program and the AWB Adjustment Program. The Automatic Adjustment Program automatically controls the adjustment operations that were formerly entered manually on the operation screen of the SEUS (some adjustments may be manually operated on the SEUS operation screen). The AWB Adjustment Program automatically performs "AWB 3200K-5800K Standard Data Input" of Camera System Adjustment. 1-2-1. Automatic Adjustment Program 1. Precautions When Using Automatic Adjustment Program 1) The Automatic Adjustment Program writes the adjustment results such as EVR data to the set through two-way communication with the camera via the SEUS. Accordingly, the Automatic Adjustment Program must be used in the environment where the SEUS operates. 2) The program run time may vary depending on the environment of the personal computer used. 3) The SEUS must be already started on the PC when using the Automatic Adjustment Program. With the SEUS not started, some adjustment items will take time in adjustment. 2. Start of Automatic Adjustment Program Double-click the application file (DSC-W55 Auto-Adj Ver_1.0r01.exe), and the Automatic Adjustment Program will start.

3. Function of Each Button on Main Menu Screen When the Automatic Adjustment Program started, the Main Menu screen in Fig. 6-1-10 will appear. On this screen, select each adjustment section.

6

1 2 3 4 5

Fig. 6-1-10
1 [Connecting the Equipment] button A connection diagram of the equipment is displayed. 2 [VIDEO SYSTEM ADJUSTMENT] button The "VIDEO SYSTEM ADJUSTMENT" screen appears. 3 [CAMERA SYSTEM ADJUSTMENT] button The "CAMERA SYSTEM ADJUSTMENT" screen appears. 4 [LCD SYSTEM ADJUSTMENT] button The "LCD SYSTEM ADJUSTMENT" screen appears. 5 [END] button The Automatic Adjustment Program finishes. 6 This part indicates the version of Automatic Adjustment Program.

DSC-W55_ADJ 6-10

1-2-2. AWB Adjustment Program 1. Application Environment OS: Windows 98/98SE/Me/2000/XP RAM: 256MB or more recommended USB: 2.0 recommended (also compatible with 1.1) Two connectors are required. 2. Installation Method Extract the file compressed in the ZIP format (W35W55 AWBAdjustment.zip). Execute the extracted file (setup.exe), and the installer will start. Install the program following the instructions given on the installer screen. 3. Notes When Using the AWB Adjustment Program 1) The SEUS must be installed in the PC. 2) The HASP Key for SEUS must be connected to the USB connector. The program will not start unless the HASP Key is connected. 4. Starting Method of AWB Adjustment Program Click the [Start] button on the task bar, and click the [DSC-W35, W55 AWB Adjustment] from the [Programs], and the program will start.

5.

Screen and Function of Each Button of AWB Adjustment Program
4

1 2 3

A

Fig. 6-1-11
1 [Connect] button Makes connection to the camera and switches the camera to the adjustment mode. In the case of successful connection to the camera, the indication at the part A changes to "Connected" and the following buttons become active. · [AWB 3200K-5800K Standard Data Input] button · [Disconnect] button 2 Adjustment start buttons Start the adjustment or checking of respective button names. 3 [Disconnect] button Cancels the connection to the camera. 4 Captured picture display screen Displays a picture captured by the camera when the adjustment or checking was performed.

DSC-W55_ADJ 6-11

1-3.
1-3-1.

VIDEO SYSTEM ADJUSTMENTS

1-3-2.

Function of Each Button on Video System Adjustment Screen Click the [VIDEO SYSTEM ADJUSTMENT] button on the Main Menu screen, and the "VIDEO SYSTEM ADJUSTMENT" screen in Fig. 6-1-12 will appear.
1

Adjustment Items of VIDEO System Adjustment The adjustment items of video system adjustment are as listed in Table 6-1-2. The Automatic Adjustment Program executes the adjustment items if the VIDEO Adjustment Start button is clicked. Button Name Adjustment Signal Page Arbitrary 8F Address D0

VIDEO VIDEO Output Adjustment Level Adj.

Table 6-1-2
2 3 4 5

Fig. 6-1-12
1 [To Menu] button The Main Menu screen comes back. 2 [Preparation] button Notes for adjustment or jigs usd are displayed. 3 [Start] button "Video Adjustment" starts. 4 [Reset] button This button functions same as the "Initialize" of the setup screen. 5 [Release Data Setting] button The data setting at the adjustment is cancelled. During the data setting, the button color changes from "white" to "red". When the data setting is cancelled, the button color returns to "white". (Use this button when an error occurred in the video adjustment. If the adjustment completed successfully, the data setting is automatically cancelled and the button color returns to "white".)

DSC-W55_ADJ 6-12

1-3-3. Adjusting Method [Automatic Adjustment Program execution items and sequence] 1. Data Setting during Video Adj. 2. Video Output Level Adj. 3. Release of Data Setting during Video Adj. [Specified value of video output level adj.] Measurement Point Video terminal of USB, A/V cable for multi-use terminal (75 terminated) Oscilloscope Sync level: A = 286 ± 5 mV (NTSC mode) A = 300 ± 5 mV (PAL mode) Burst level: B = 286 ± 25 mV (NTSC mode) B = 300 ± 25 mV (PAL mode)

SEUS operation screen
UP/DOWN key

Measuring Instrument Specified Value

Fig. 6-1-15
Check on the oscilloscope

[Adjusting method] 1) Click the [Start] button of the VIDEO Adjustment. 2) The Automatic Adjustment Program executes the "1. Data Setting during Video Adj.". 3) If "1. Data Setting during Video Adj." completed successfully, the next message is displayed during the execution of "2. Video Output Level Adj.". Using the UP/DOWN key on the SEUS Operation screen, adjust so that the sync level of the video signals satisfies the specified value. After the adjustment, check that the burst level of the video signals satisfies the specified value, and click the [OK] button in the message.

B

A

H

Fig. 6-1-16

Fig. 6-1-13
4) If the [OK] button button is clicked, "3. Release of Data Setting during Video Adj." will be executed. 5) Upon successful completion of all items of the VIDEO Adjustment, the following message is displayed. Click the [OK] button.

Fig. 6-1-14

DSC-W55_ADJ 6-13

1-4.
1-4-1.

CAMERA SYSTEM ADJUSTMENTS

Function of Each Button on Camera System Adjustment Screen Click the [CAMERA SYSTEM ADJUSTMENT] button on the Main Menu screen, and the "CAMERA SYSTEM ADJUSTMENT" screen in Fig. 6-1-17 will appear.
1

3 2 3

3

5

4

Fig. 6-1-17
1 [To Menu] button The Main Menu screen comes back. 2 [Preparation] button Notes for adjustment or jigs used are displayed. 3 [Start] button Each adjustment from "Camera Adjustment 1" to "Camera Adjustment 6" starts. 4 [Reset] button This button functions same as the "Initialize" of the setup screen. 5 [Release Data Setting] button The data setting at the adjustment is cancelled. During the data setting, the button color changes from "white" to "red". When the data setting is cancelled, the button color returns to "white". (Use this button when an error occurred in the camera adjustment 1-6. If the adjustment completed successfully, the data setting is automatically cancelled and the button color returns to "white".)

DSC-W55_ADJ 6-14

Adjustment Items of Camera System Adjustment The adjustment items of camera system adjustment are as listed in Table 6-1-3. The Automatic Adjustment Program divides the adjustment items into six, camera adjustment 1-6. Clicking either CAMERA Adjustment Start button allows the adjustment item which corresponds to that button to be executed. The adjustment conditions of the subject and filter vary depending on which item is adjusted. The Adjustment Program displays an instruction for the subject and filter as a message during the adjustment. Button Name CAMERA Adjustment 1 Adjustment Flange Back Adj. Subject Siemens star chart with ND filter for minipattern box (Note 1) or Flange back adjustment jig Siemens star (1.0m from front the lens) (Luminance: 200 to 400 lux) Adjustment Page 6D 6F _ 6F 6F Clear chart (Standard picture frame) Mechanical Shutter Adj. Light Value Adj. (Note 2) AWB 3200K-5800K Standard Data Input Color Reproduction Check CCD Linearity Check CAMERA Adjustment 4 CCD White Defect Compensation Check CCD Black Defect Compensation Check CAMERA Adjustment 5 CAMERA Adjustment 6 Strobe Adj. Auto focus illumination Check Flash adjustment box (50 cm) Flash adjustment box (50 cm) Clear chart (Standard picture frame) 9 colors chart (Standard picture frame) 9 colors chart (Standard picture frame) 6F 78 6F 6F 6E 6C _ _ _ 6E 6F 6D 6F 06, 07 60, 6B to 6D 6B, 6F 0C to 0F 6B to 6D, B8 to BB, C7, C8 65 to 67 00 to 21, 24 to 49 58 to 5F _ _ _ 72 to 75 D8 to EF B8 to BF 10 to 15 Adjustment Address A4 to B7, D0 to F7 18 to 53 _

1-4-2.

CAMERA Adjustment 2

Flange Back Check Color Shade Adj. & Check F No. Compensation

CAMERA Adjustment 3

Measure Gain Adj.

Note 1: Dark Siemens star chart. Note 2: Use the AWB Adjustment Program (W35W55AwbAdjustment.exe).

Table 6-1-3

DSC-W55_ADJ 6-15

1-4-3. Adjusting Method 1. CAMERA Adjustment 1 [Automatic Adjustment Program execution items and sequence] 1. Data Setting during Camera Adj. 2. Flange Back Adj. 3. Release of Data Setting during Camera Adj. [Adjusting method] 1) Click the [Start] button of the CAMERA Adjustment 1. 2) The Automatic Adjustment Program executes "1. Data Setting during Camera Adj.". 3) Upon successful completion of the "1. Data Setting during Camera Adj.", the following message is displayed. Set the subject by referring to "Preparation of Flange Back Adj.".

Preparation of Flange Back Adj. (Using the minipattern box) 1) The minipattern box is installed as shown in the following figure. Note 1: The attachment lenses are not used. Note 2: Take care not to hit the mini-pattern box when extending the lens. 2) Install the minipattern box so that the distance between it and the front of lens of camera is less than 3 cm. 3) Make the height of minipattern box and the camera equal. 4) Check the output voltage of the regulated power supply is the specified voltage ± 0.01 Vdc. 5) Check that the center of Siemens star chart meets the center of shot image screen with the zoom lens at TELE end and WIDE end respectively. Specified voltage: The specified voltage varies according to the minipattern box, so adjustment the power supply output voltage to the specified voltage written on the sheet which is supplied with the minipattern box.
Below 3 cm Minipattern box

Fig. 6-1-18
Camera

4) If the [OK] button is clicked, "2. Flange Back Adj." and "3. Release of Data Setting during Camera Adj." will be executed. 5) Upon successful completion of all items of the CAMERA Adjustment 1, the following message is displayed. Click the [OK] button.

Regulated power supply Output voltage : Specified voltage ± 0.01 Vdc Output current : more than 3.5 A

Red (+) Black (­) Yellow (SENS +)

Fig. 6-1-19

White (SENS ­) Black (GND)

Need not connected

Fig. 6-1-20
Preparation of Flange Back Adj. (Using the flange back adjustment jig) (Luminance: about 300 lux) 1) Install the flange back adjustment jig so that the distance between it and the front of lens of camera is less than 3 cm. Note 3: Take care not to hit the flange back adjustment jig when extending the lens. 2) Make the height of flange back adjustment jig and the camera equal. 3) Check that the center of chart meets the center of shot image screen with the zoom lens at TELE end and WIDE end respectively.
Flange back adjustment jig Below 3 cm

Camera

Fig. 6-1-21

DSC-W55_ADJ 6-16

2. CAMERA Adjustment 2 [Automatic Adjustment Program execution items and sequence] 1. Data Setting during Camera Adj. 2. Flange Back Check 3. Release of Data Setting during Camera Adj. [Adjusting method] 1) Click the [Start] button of the CAMERA Adjustment 2. 2) The Automatic Adjustment Program executes "1. Data Setting during Camera Adj.". 3) Upon successful completion of the "1. Data Setting during Camera Adj.", the following message is displayed. Set the subject in accordance with the message.

3. Picture Frame Setting (Standard Picture Frame) In the "CAMERA Adjustment 3", "AWB 3200K-5800K Standard Data Input" and "CAMERA Adjustment 4", set the picture frame so as to attain the positions shown in the following figure when shooting the 9 colors chart. Check on the oscilloscope Measurement Point: Video terminal of USB, A/V cable for multiuse terminal (75 terminated) 1. Horizontal period
A=B A B A

Fig. 6-1-22
4) Click the [OK] button is clicked, "2. Flange Back Check" is executed. The following messages are displayed, and then operate the camera to make a check in accordance with the messages.

Fig. 6-1-25
2. Vertical period
C C= B 3 V B C

Fig. 6-1-26
Check on the monitor TV or the LCD screen
A=B C= B 3 A C Green Yellow W14

C14: Filter for AWB 5800K adjustment

Fig. 6-1-23
5) Upon completion of "2. Flange Back Check", "3. Release of Data Setting during Camera Adj." is executed. 6) Upon successful completion of all items of the CAMERA Adjustment 2, the following message is displayed. Click the [OK] button.

A

B

Cyan

White

Red

B

C14

Blue Magenta C

Effective picture frame

Fig. 6-1-24

A 2 Transparent window

Fig. 6-1-27

DSC-W55_ADJ 6-17

4. CAMERA Adjustment 3 [Automatic Adjustment Program execution items and sequence] 1. Data Setting during Camera Adj. 2. Picture Frame Setting 3. Color Shade Adj. & Check 4. F No. Compensation 5. Measure Gain Adj. 6. Mechanical Shutter Adj. 7. Light Value Adj. 8. Release of Data Setting during Camera Adj. [Adjusting method] 1) Click the [Start] button of the CAMERA Adjustment 3. 2) The Automatic Adjustment Program executes the "1. Data Setting during Camera Adj.". 3) Upon successful completion of "1. Data Setting during Camera Adj.", "2. Picture Frame Setting" is executed. The following message is displayed, and then referring to Fig. 6-1-25 to Fig. 6-1-27 (See page 6-17), set the subject and click the [OK] button.

Fig. 6-1-28
After that, the next message is displayed. Then, change the chart in accordance with the message.

Fig. 6-1-29
4) Click the [OK] button, and the items from "3. F No. Compensation" to "8. Release of Data Setting during Camera Adj." will be executed. 5) Upon successful completion of all items of the CAMERA Adjustment 3, the following message is displayed. Click the [OK] button.

Fig. 6-1-30

DSC-W55_ADJ 6-18

5. AWB 3200K-5800K Standard Data Input [Adjustment method] 1) Start the AWB Adjustment Program (W35W55AwbAdjustment.exe). 2) Click the [Connect] button to set the camera to the adjustment mode.

6) A picture captured by the camera is displayed on the screen, and the adjustment and checking are performed.

Fig. 6-1-33
Note: If the following message is displayed, the picture frame setting is faulty. Check the picture frame, and then perform readjustment.

Fig. 6-1-31
3) Adjust the mode dial of the camera to "CAMERA" and set MACRO mode. Shoot the 9 colors chart with the zoom at WIDE end. 4) Adjust the camera direction and distance to set the picture frame. (Refer to 3. Picture Frame Setting) 5) Click the [AWB 3200K-5800K Standard Data Input] button.

Fig. 6-1-34
7) Upon successful completion of the adjustment, the following message is displayed. Click the [OK] button.

Fig. 6-1-32

Fig. 6-1-35
8) Perform the "Camera Adjustment 4" successively without turning off the power switch of the camera.

DSC-W55_ADJ 6-19

6. CAMERA Adjustment 4 Note: After executing the "AWB 3200-5800K Standard Data Input" perform the "CAMERA Adjustment 4" successively without turning off the power switch of the camera. [Automatic Adjustment Program execution items and sequence] 1. Data Setting during Camera Adj. 2. Picture Frame Setting 3. Color Reproduction Check 4. CCD Linearity Check 5. CCD White Defect Compensation Check 6. CCD Black Defect Compensation Check 7. Release of Data Setting during Camera Adj.

At this time, the following message is displayed, and click the [Yes] button if the check result display at the upper right of Color Reproduction Check screen is OK, or the [No] button if NG.

Fig. 6-1-38
[Adjusting method] 1) Click the [Start] button of the CAMERA Adjustment 4. 2) The Automatic Adjustment Program executes the "1. Data Setting during Camera Adj.". 3) Upon successful completion of "1. Data Setting during Camera Adj.", "2. Picture Frame Setting" is executed. The following message is displayed, and then referring to Fig. 6-1-25 to Fig. 6-1-27 (See page 6-17), set the subject and click the [OK] button. 5) Upon successful completion of "3. Color Reproduction Check", the following message is displayed. Change the chart in accordance with the message.

Fig. 6-1-39
6) Click the [OK] button, and the items from "4. CCD Linearity Check" to "7. Release of Data Setting during Camera Adj." will be executed. 7) Upon successful completion of all items of the CAMERA Adjustment 4, the following message is displayed. Click the [OK] button.

Fig. 6-1-36
4) After that, "3. Color Reproduction Check" will be executed. Upon completion of check, the check result is displayed on the Color Reproduction Check screen.

Fig. 6-1-40

Fig. 6-1-37

DSC-W55_ADJ 6-20

7. CAMERA Adjustment 5 Note: "CAMERA Adjustment 5" is available only once after the power is turned on. If the adjustment is retried, turn off the power and turn on again. [Automatic Adjustment Program execution items and sequence] 1. Data Setting during Camera Adj. 2. Strobe Adj. 3. Release of Data Setting during Camera Adj. [Adjusting method] 1) Click the [Start] button of CAMERA Adjustment 5. 2) The Automatic Adjustment Program executes the "1. Data Setting during Camera Adj.". 3) Upon successful completion of the "1. Data Setting during Camera Adj.", the following message is displayed. Set the subject in accordance with the message. (For the Flash adjustment box, refer to "3. Preparing the Flash Adjustment Box" (see page 6-8).)

8. CAMERA Adjustment 6 [Automatic Adjustment Program execution items and sequence] 1. Data Setting during Camera Adj. 2. Auto Focus Illumination Check 3. Release of Data Setting during Camera Adj. [Adjusting method] 1) Click the [Start] button of CAMERA Adjustment 6. 2) The Automatic Adjustment Program executes the "1. Data Setting during Camera Adj.". 3) Upon successful completion of the "1. Data Setting during Camera Adj.", the following message is displayed. Set the subject in accordance with the message. (For the Flash adjustment box, refer to "3. Preparing the Flash Adjustment Box" (see page 6-8).)

Fig. 6-1-44
4) Press the [OK] button, and the "2. Auto Focus Illumination check" will be executed. 5) Upon successful completion of the "2. Auto Focus Illumination Check", the "3. Release of Data Setting during Camera Adj." will be executed successively. 6) Upon successful completion of all items of the CAMERA Adjustment 6, the following message is displayed. Click the [OK] button.

Fig. 6-1-41
4) Press the [OK] button, and the "2. Strobe Adj." will be executed. 5) During execution of "2. Strobe Adj.", the following message is displayed. After checking the flashing of strobe light, click the [OK] button. (This message is displayed 2 times during execution of adjustment.)

Fig. 6-1-45 Fig. 6-1-42
6) Upon successful completion of "2. Strobe Adj.", "3.Release of Data Setting during CAMERA Adj." is executed. 7) Upon successful completion of all items of the CAMERA Adjustment 5, the following message is displayed. Click the [OK] button.

Fig. 6-1-43

DSC-W55_ADJ 6-21

1-5.
1-5-1.

LCD SYSTEM ADJUSTMENTS

Function of Each Button on LCD System Adjustment Screen Click the [LCD SYSTEM ADJUSTMENT] button on the Main Menu screen, and the "LCD SYSTEM ADJUSTMENT" screen in Fig. 6-1-46 will appear.
1

1-5-2. Adjustment Items of LCD System Adjustment The adjustment items of LCD system adjustment are as listed in Table 6-1-4. The Automatic Adjustment Program executes the adjustment items if the LCD Adjustment Start button is clicked. Button Name Adjustment Signal Page 8F 8F Address 11 42, 43

V-COM adj. LCD Arbitrary Adjustment White Balance adj.

Table 6-1-4
2 3 4

Fig. 6-1-46
1 [To Menu] button The Main Menu screen comes back. 2 [Start] button "LCD Adjustment" starts. 3 [Reset] button This button functions same as the "Initialize" of the setup screen. 4 [Release Data Setting] button The data setting at the adjustment is cancelled. During the data setting, the button color changes from "white" to "red". When the data setting is cancelled, the button color returns to "white". (Use this button when an error occurred in the LCD adjustment. If the adjustment completed successfully, the data setting is automatically cancelled and the button color returns to "white".)

DSC-W55_ADJ 6-22

1-5-3. Adjusting Method [Automatic Adjustment Program execution items and sequence] 1. Data Setting during LCD Adj. 2. V-COM Adj. 3. White Balance Adj. 4. Release of Data Setting during LCD Adj. [Adjusting method] 1) Click the [Start] button of the LCD Adjustment. 2) The Automatic Adjustment Program executes "1. Data Setting during LCD Adj. ". 3) Upon successful completion of the "1. Data setting during LCD Adj. & EVR Data Write", the following message is displayed during execution in "2. V-COM Adj. ". On the SEUS screen, operate the UP/DOWN key so that the brightness of portions A and B on the LCD panel is equal. After the adjustment, click the [OK] button.

SEUS operation screen
UP/DOWN key

Fig. 6-1-50
Check on the LCD screen (V-COM Adj.)

A
Fig. 6-1-47
4) Upon completion of "2. V-COM Adj.", "3. White Balance Adj." is executed. The following message is displayed, and then check that LCD screen is not colored. If colored, change the data of page: 8F, address: 19 and 1A on the SEUS Operation screen to adjust so that the LCD screen is not colored.

B

Fig. 6-1-51

Fig. 6-1-48
5) If the [OK] button is clicked, "4. Release of Data Setting during LCD Adj." will be executed. 6) Upon successful completion of all item the LCD Adjustment, the following message is displayed. Click the [OK] button.

Fig. 6-1-49

DSC-W55_ADJ 6-23

1-6.

ERROR

3.

Adjustment Time Out

In case of an error during the execution of adjustment, the Automatic Adjustment Program interrupts the processing at that point, and displays an error message, and then terminates the program execution there. 1-6-1. Error Message When an error message is displayed, perform the remedy given below, and then retry adjustment. If the error message is displayed though the remedy was performed, the circuits will be faulty.
This part indicates the adjustment item in which an error occurred.

Fig. 6-1-54
1. Connect Error Symptom Cause Remedy Adjustment does not finish within the specified time. · Adjustment conditions are wrong. · Data error exists in the camera. · Check that the conditions such as a subject are correct. · Reset the camera.

Fig. 6-1-52
Symptom Cause USB communication with the set is abnormal. · USB cable is not inserted tightly. · Power supply is not installed correctly. · Communication with SEUS is abnormal. · Disconnect the USB cable once, and then reconnect it tightly and check that the set is in "USB Mode". · Install the power supply correctly. · Start the SEUS and click the [Connect] to check that the connection state is established.

4.

Adjustment NG

Remedy

This part indicates the adjustment item in which an error occurred.

Fig. 6-1-55
Symptom The adjusted data does not become the specified value. · Adjustment conditions are wrong. · Data error exists in the camera. · Check that the conditions such as a subject are correct. · Reset the camera.

2.

RESET the CAMERA and Try Again

Cause Remedy

Fig. 6-1-53
Symptom Cause Remedy The camera is not ready for adjustment. Data error exists in the camera. Reset the camera.

DSC-W55_ADJ 6-24

5.

Data Save Error

1-6-2. Precautions When an Error Occurred The Automatic Adjustment Program sets the data for adjustment before the adjustment starts. Accordingly, if the adjustment terminates by an error, the data during the adjustment may be left in the camera. Note 1: With this data left in the camera, the camera will not operate normally. In this case, the [Release Data Setting] button is displayed in "red" on the screen as shown in Fig. 6-1-57, 58 and 59. Click the [Release Data Setting] button to cancel the data setting. When the data setting is cancelled, the button color becomes "white". Note 2: When "Data Save Error" occurred, the [Release Data Setting] button is displayed in "white". To cancel the data setting, perform it on the SEUS Operation screen. How to cancel the data setting is displayed in the error message. Video System Adjustment screen

How to cancel the data setting during adjustment is display here.

Fig. 6-1-56
Symptom Cause data cannot be saved normally. (The data setting during adjustment cannot be cancelled) · Data writing to the flash memory failed. · Connection is faulty. · Power supply is not installed correctly. · On the SEUS Operation screen, [Set] the data to the pages and addresses displayed in the message, and [Save] them. (Cancel manually the data setting during adjustment.) · Check the connection. · Install the power supply correctly.

Remedy

Fig. 6-1-57
Camera System Adjustment screen

Fig. 6-1-58
LCD System Adjustment screen

Fig. 6-1-59

DSC-W55_ADJ 6-25

1-7.

INITIALIZATION OF DATA

1. Initializing All Page Data By performing the following procedure, data of all pages will be initialized. Note: If all page data have been initialized, all adjustments need to be performed again. Initializing Method: 1) Select page: 00, address: 01 and set data: 01. 2) Click [Sector Write] on the SEUS screen to display the SEUS SECTOR WRITE screen. 3) Check that the SET ID is "04". 4) Click [All] of the ALL SELECT buttons to select all pages. (Fig. 6-1-60 A) 5) Click [Write] to write the initializing data to the flash memory of the camera. 6) Wait for 3 sec. 7) Click [Close] to close the SEUS SECTOR WRITE screen. 8) Click [Save] on the SEUS screen. 9) Select page: 80, address: 34, and check that the data is "00". 10) Select page: 80, address: 30, and check that the data is "00". 11) Perform"VIDEO OUT Default Data Check" and "Initial Language Data Check". Processing after Completing Initializing Order Page Address 1 40 28 Data 01 [Set] (Note) Procedure

2. Initializing Single Page Data By performing the following procedure, data of the page that you want to initialize will be initialized. Note 1: If the 6C or 6D or 6E or 6F or 78 page data have been initialized, the following adjustment needs to be performed again. 1) Camera system adjustments Note 2: If the 8F page data have been initialized, the following adjustment needs to be performed again. 1) Video system adjustments 2) LCD system adjustments Initializing Method: 1) Select page: 00, address: 01 and set data: 01. 2) Click [Sector Write] on the SEUS screen to display the SEUS SECTOR WRITE screen. 3) Check that the SET ID is "04". 4) Click "All" of the option buttons of target page. (Fig. 6-1-60 B) 5) Click [Write] to write the initializing data to the flash memory of the camera. 6) Wait for 3 sec. 7) Click [Close] to close the SEUS SECTOR WRITE screen. 8) Click [Save] on the SEUS screen. 9) Select page: 80, address: 34, and check that the data is "00". 10) Select page: 80, address: 30, and check that the data is "00". 11) When 4F page is initialized, perform "VIDEO OUT Default Data Check" and "Initial Language Data Check". Processing after Completing Initializing Order Page Address 1 40 28 Data 01 [Set] (Note) Procedure

Note: At this time, the camera is reset and the power is turns off once and then on again. Accordingly, the SEUS goes in "disconnect" state, but this is not a trouble. Click [Connect] on the SEUS screen to restore the "connected" state. (In case that the power does not turn on again, press the power button.)
B

Note: At this time, the camera is reset and the power is turns off once and then on again. Accordingly, the SEUS goes in "disconnect" state, but this is not a trouble. Click [Connect] on the SEUS screen to restore the "connected" state. (In case that the power does not turn on again, press the power button.)

04

A

Fig. 6-1-60

DSC-W55_ADJ 6-26

6-2. SERVICE MODE
1. Setting the Test Mode Address A1, A3

2. Bit Value Discrimination In the following items, the bit values must be discriminated from the data displayed on the SEUS. Whether bit values are "1" or "0" can be discriminated from the table shown below. Data displayed on SEUS

Page 40

· Forced CAMERA mode 1) Select page: 40, address: A1, and set data: 01. 2) Select page: 40, address: A3, and set data: 01. · Forced MOVIE mode 1) Select page: 40, address: A1, and set data: 01. 3) Select page: 40, address: A3, and set data: 07. · Forced PLAY mode 1) Select page: 40, address: A1, and set data: 01. 2) Select page: 40, address: A3, and set data: 08. · After completing adjustments/repairs, release the data setting. 1) Select page: 40, address: A1, and set data: 00.

00
bit 3 to bit 0 discriminated bit 7 to bit 4 discriminated Bit values Display on the SEUS 0 1 2 3 4 5 6 7 A 8 9 A B C D B E F bit3 or bit7 0 0 0 0 0 0 0 0 1 1 1 1 1 1 1 1 bit2 or bit6 0 0 0 0 1 1 1 1 0 0 0 0 1 1 1 1 bit1 or bit5 0 0 1 1 0 0 1 1 0 0 1 1 0 0 1 1 bit0 or bit4 0 1 0 1 0 1 0 1 0 1 0 1 0 1 0 1

DSC-W55_ADJ 6-27

3.

LED Check Address 12 Address FE

Page 80 Page 8E

Using method: 1) Select page: 00, address: 01, and set data: 01. 2) Select page: 40, address: 98, and check that the data is "00". 3) Select page: 8E, address: FE, and set data: 20. 4) Select page: 80, address: 12, and set data: 01. 5) Check that all LED are lit. · SELF TIMER/AF ILLUMINATOR · AE/AF LOCK · FLASH CHARGE · MS ACCESS 6) Select page: 80, address: 12, and set data: 00. 7) Select page: 8E, address: FE, and set data: 00. 8) Select page: 00, address: 01, and set data: 00. 9) Click [Disconnect] on the SEUS screen. 10) Disconnect the USB cable. 11) Turn off the power. 4. Switch Check (1) Address 13 Function Shutter button (XAE LOCK SW) RL-074 flexible S003 Shutter button (XSHUTTER SW) RL-074 flexible S003 When data = 00 OFF When data = 01 ON When data = 02 ON

Page 80

OFF

OFF

ON

Using method: 1) Select page: 80, address: 13. 2) By discriminating the read data, the state of the switches can be discriminated.

DSC-W55_ADJ 6-28

5.

Switch Check (2) Addresses A0 to A2

Page 20

Using method: 1) Select page: 20, addresses: A0 to A2. 2) By discriminating the read data, the pressed key can be discriminated. Address Data 00 to 03 25 to 37 41 to 57 CONTROL UP (SW-498 board) (S006) MENU (SW-498 board) (S007) 5B to 6F CONTROL LEFT (SW-498 board) (S008) 73 to 91 CONTROL SET (SW-498 board) (S009) FF No key input

CONTROL DOWN CONTROL RIGHT A0 (KEY AD0) (SW-498 board) (SW-498 board) (IC101 K23) (S001) (S004) A1 (KEY AD1) (IC101 L23) SCREEN DISPLAY IMAGE SIZE/ ON/OFF DELETE (SW-498 board) (SW-498 board) (S002) (S005)

No key input

A2 ZOOM W ZOOM T (KEY AD2) (RL-074 flexible) (RL-074 flexible) (IC101 H25 ) (S005) (S006)

No key input

6.

Mode Dial Check Addresses A3, A4

Page 20

Using method: 1) Select page: 20, addresses: A3 and A4. 2) By discriminating the read data, the state of the mode dial can be discriminated. Address A3 (MODE DIAL0) (IC101 L22) Data 00 to 07 Soft snap (Control SW block) 25 to 37 High sensitivity (Control SW block) Twilight (Control SW block) 41 to 57 AUTO (Control SW block) Landscape (Control SW block) 5B to 6F P_AUTO (Control SW block) Beach (Control SW block) 73 to 91 MOVIE (Control SW block) Snow (Control SW block) FF Others

Twilight portrait A4 (MODE DIAL1) (Control SW (IC101 L25 ) block)

Others

7.

Self Diagnosis Code Countermeasure Turn the power off and on again. Format the "Memory Stick" or internal memory. Insert a new "Memory Stick". Turn the power off and on again. Cause Trouble with hardware. "Memory Stick" or internal memory is unformatted. "Memory Stick" is broken. Trouble with internal memory. When failed in the focus and zoom initialization. Abnormality when flash is being charged. Caution Display During Error SYSTEM ERROR FORMAT ERROR MEMORY STICK ERROR INTERNAL MEMORY ERROR --

Display Code C:32:ss

C:13:ss

E:61:ss E:91:ss

Checking of lens drive circuit. Checking of flash unit or replacement of flash unit. (Note)

Note: After repair, be sure to execute the "Initialize" of the setup screen.

DSC-W55_ADJ 6-29E

DSC-W55
Auto-ADJ

SERVICE MANUAL
Ver. 1.1 2007.06

SUPPLEMENT-1
File this supplement with the service manual.
(DI07-027)

· Change of Automatic Adjustment Program

· Change of Automatic Adjustment Program
Version of Automatic Adjustment Program has been changed from Ver_1.0r01 into Ver_1.1r02.
: Points changed portion.

3. Function of Each Button on Main Menu Screen (Service manual page 6-10) When the Automatic Adjustment Program started, the Main Menu screen in Fig. 6-1-10 will appear. On this screen, select each adjustment section.

6-1. CAMERA SECTION ADJUSTMENTS
1-2. ADJUSTMENT PROGRAMS
6 1 2 3 4 5

1-2-1. Automatic Adjustment Program 2. Start of Automatic Adjustment Program (Service manual page 6-10) Double-click the application file (DSC-W55 Auto-Adj Ver_1.1r02.exe), and the Automatic Adjustment Program will start.

Fig. 6-1-10
6 This part indicates the version of Automatic Adjustment Program.

DSC-W55_ADJ
9-852-160-81

Sony EMCS Co.

2007F0500-1 © 2007.6 Published by Kohda TEC

DSC-W55
Auto-ADJ

SERVICE MANUAL
Ver. 1.2 2008.03

SUPPLEMENT-2
File this supplement with the service manual.
(DI07-274)

· Change of Automatic Adjustment Program · Addition of "DESTINATION DATA WRITE" · Correction of Adjustment Condition

· Precaution on Replacing the SY-176 Board · Change of Automatic Adjustment Program
Version of Automatic Adjustment Program has been changed from Ver_1.1r02 into Ver_1.2r03.
: Points changed portion. 3. Function of Each Button on Main Menu Screen When the Automatic Adjustment Program started, the Main Menu screen in Fig. 6-1-10 will appear. On this screen, select each adjustment section.

& : Points added portion.
1-2.

6-1. CAMERA SECTION ADJUSTMENTS
6 1 7 2

ADJUSTMENT PROGRAMS

1-2-1. Automatic Adjustment Program (Supplement-1 page 1) 2. Start of Automatic Adjustment Program Double-click the application file (DSC-W55 Auto-Adj Ver_1.2r03.exe), and the Automatic Adjustment Program will start.

&

3 4

5

Fig. 6-1-10
6 This part indicates the version of Automatic Adjustment Program. button & 7 [DESTINATION DATA WRITE]WRITE" screen appears. The "DESTINATION DATA

DSC-W55_ADJ
9-852-160-86

Sony EMCS Co.

2008C0500-1 © 2008.3 Published by Kohda TEC

· Addition of "DESTINATION DATA WRITE"
Precaution on Replacing the SY-176 Board
At first, execute "DESTINATION DATA WRITE" when the SY-176 board was replaced. By executing this processing, "VIDEO OUT Default Data Check" and "Initial Language Data Check" on page 6-1 and page 6-2 of the Service Manual is no longer necessary.

DESTINATION DATA WRITE
If this processing is executed, the SY-176 board is set to the factory default setting according to the specified destination. Setting items: · Font data for camera display · Initial setting of display language · VIDEO OUT Default Data 1. Function of Each Button on Destination Data Write Screen Click the [DESTINATION DATA WRITE] button on the Main Menu screen, and the "DESTINATION DATA WRITE" screen in following figure will appear.
1

2. Destination Data Write [Writing method] 1) Prepare a Memory Stick formatted by a camera. 2) Copy all of the font data CX_FONT2.ash to CX_FONT4.ash supplied with this program to the root directory of the Memory Stick. 3) Insert the Memory Stick in the set. 4) Select the target destination from the pulldown list.

2

3

4

5) Click the [Data Write] button.

5

1 [To Menu] button Return to the main menu. 2 Destination List Select the written destination 3 [Data Write] button Write the destination data to the camera. 4 [ ? ] button Indicate the destination table. 5 [Procedure] button Indicate the procedure. 6) When the "Set the camera to PB mode" message is appeared, confirm that the camera mode is PB. Then click the [OK] button to continue the processing. 7) Following message will be appeared after completing data writing.

8) Remove the Memory Stick from the set and disconnect the USB cable. 9) Execute the Initialize operation using the Setup screen.

DSC-W55_ADJ --2--

LANGUAGE GP

SELECTABLE LANGUAGE
DESTINATION Portuguese Norwegian Traditional Chinese Hungarian Japanese Simplified Chinese VIDEO OUT Default AREA

Swedish

Spanish

German

Russian

Persian

English

Turkish

Korean

Finnish

French

Danish

Arabic

Czech

Polish

Greek

Italian

GP2

GP3

GP4

U2 CA2 AU2 CEE2 CEE8 CEE9 CEH E14 E15 E32 E33 E37 AR2 BR1 HK1 CN1 KR2 JE3

US CND AUS AEP UK

Malay

Dutch

Thai

E

AR BR HK CH KR JE

z z z a z z z z z z a z a a z a a z

a a a a a a a

a a a a

a a a a a a a a a a z a z a a a a a

a a a a a a a

a a a a a a a a a a a a a z a a a a

a a a a a a a z a a a a a a a a a a a a a a a a a a a a a a a a a a a a a a a a a a a a a a a a a a a a a a a a a a a a a a a a a a a a a a a a a a a a a a a a

a a a a a a a a z a a

a a a a a a a a a a a

a a a a a a a a a a a

a a a a a a a a a z a

NTSC NTSC PAL PAL PAL PAL PAL PAL PAL PAL NTSC PAL NTSC NTSC PAL PAL NTSC PAL

· Correction of Adjustment Condition
: Points changed portion.

1-4.
1-4-2.

CAMERA SYSTEM ADJUSTMENTS

Adjustment Items of Camera System Adjustment (Service manual page 6-15) The adjustment items of camera system adjustment are as listed in Table 6-1-3. The Automatic Adjustment Program divides the adjustment items into six, camera adjustment 1-6. Clicking either CAMERA Adjustment Start button allows the adjustment item which corresponds to that button to be executed. The adjustment conditions of the subject and filter vary depending on which item is adjusted. The Adjustment Program displays an instruction for the subject and filter as a message during the adjustment. Button Name CAMERA Adjustment 1 Adjustment Flange Back Adj. Subject Siemens star chart with ND filter for minipattern box (Note 1) or Flange back adjustment jig Siemens star (1.0m from front the lens) (Illuminance: 200 to 400 lux) Adjustment Page 6D 6F _ 6F 6F Clear chart (Standard picture frame) Mechanical Shutter Adj. Light Value Adj. 6F 78 6F 6F 06, 07 60, 6B to 6D 6B, 6F 0C to 0F 6B to 6D, B8 to BB, C7, C8 65 to 67 Adjustment Address A4 to B7, D0 to F7 18 to 53 _

CAMERA Adjustment 2

Flange Back Check Color Shade Adj. & Check F No. Compensation

CAMERA Adjustment 3

Measure Gain Adj.

Table 6-1-3

DSC-W55_ADJ --3--

& : Points added portion.
: Points changed portion. 1-4-3. Adjusting Method 1. CAMERA Adjustment 1 (Service manual page 6-16) [Automatic Adjustment Program execution items and sequence] 1. Data Setting during Camera Adj. 2. Flange Back Adj. 3. Release of Data Setting during Camera Adj. [Adjusting method] 1) Click the [Start] button of the CAMERA Adjustment 1. 2) The Automatic Adjustment Program executes "1. Data Setting during Camera Adj.". 3) Upon successful completion of the "1. Data Setting during Camera Adj.", the following message is displayed. Set the subject by referring to "Preparation of Flange Back Adj.".

(Service manual page 6-16) Preparation of Flange Back Adj. (Using the flange back adjustment jig) (Illuminance: about 300 lux) Note 3: When using the flange back adjustment jig, take care of the following points: · For the illumination, use a light source such as an incandescent lamp or inverter type fluorescent light free from flickering. · Do not make an adjustment in the environment where fluorescent lamp flickering occurs even if the illuminance can be ensured with the room illumination only. Use an incandescent lamp or inverter type fluorescent light at a place free from the influence of room illumination. 1) Install the flange back adjustment jig so that the distance between it and the front of lens of camera is less than 3 cm. Note 4: Take care not to hit the flange back adjustment jig when extending the lens. 2) Make the height of flange back adjustment jig and the camera equal. 3) Check that the center of chart meets the center of shot image screen with the zoom lens at TELE end and WIDE end respectively.

+

Flange back adjustment jig

Below 3 cm

Fig. 6-1-18
Camera

Fig. 6-1-21

2. CAMERA Adjustment 2 (Service manual page 6-17) [Automatic Adjustment Program execution items and sequence] 1. Data Setting during Camera Adj. 2. Flange Back Check 3. Release of Data Setting during Camera Adj. [Adjusting method] 1) Click the [Start] button of the CAMERA Adjustment 2. 2) The Automatic Adjustment Program executes "1. Data Setting during Camera Adj.". 3) Upon successful completion of the "1. Data Setting during Camera Adj.", the following message is displayed. Set the subject in accordance with the message.

Fig. 6-1-22

DSC-W55_ADJ --4--

Reverse

985216053.pdf

Revision History
Ver. 1.0 1.1 1.2 Date 2007.01 2007.06 2008.03 History Official Release Supplement-1 (S1 DI07-027) Supplement-2 (S2 DI07-274) Contents -- · Change of Automatic Adjustment Program · Change of Automatic Adjustment Program Version of Automatic Adjustment Program has been changed from Ver_1.1r02 into Ver_1.2r03. · Addition of "DESTINATION DATA WRITE" · Correction of Adjustment Condition S.M. Rev. issued -- Yes Yes

DSC-W55_ADJ