SECTION 3 ELECTRICAL ADJUSTMENTS
3.1 PRECAUTIONS FOR ELECTRICAL ADJUSTMENTS 3.1.3 Signals required for adjustments NTSC and PAL color bar signals are required on "3.3 VIDEO SYSTEM ADJUTMENT". NTSC: 100% color bars (100, 0, 100, 0) (Without SETUP) 100% color bars (100, 7.5, 100, 7.5) (With SETUP) PAL: 100% color bars (100, 0, 100, 0) (PAL does not use SETUP.) (1) Composite 100% color bars 3.1.1 Measuring instruments and Tools required for adjustments (1) Measuring instruments · Oscilloscope: 2-trace, 100 MHz or more. · NTSC/PAL waveform monitor (WFM) · NTSC/PAL Composite and Y/C video signal generator · Frequency counter: 10 MHz or more, resolution 100 mV or less. · Monitor TV (2) Tools
1 Alignment tape
B Vp-p

Electrical adjustments should be performed only when they are required, for example, during maintenance. Electrical adjustments that are possible only after mechanism adjustments should be performed after completing these. Before proceeding to perform electrical adjustments, be sure to warm up the unit for at least 10 minutes after turning it on. Use the 10:1 probe with the oscilloscope unless otherwise specified.

NTSC : A = 0.714, B = 0.286, C = 0.0536S (SETUP 7.5%) PAL : A = 0.7, B = 0.3, C = 0

A Vp-p

C Vp-p

1.24 Vp-p

VFK1842

Fig. 3.1.3 (1) (2) Y/C 100% color bars
Y/C (Y) NTSC : A = 0.714, B = 0.286, C = 0.0536 (SETUP 7.5%) PAL : A = 0.7, B = 0.3, C = 0

2

Rewrite board (Jig connector)

VFK1846

A Vp-p

C Vp-p

1.0 Vp-p

Table 3-1-1 3.1.2 Alignment tape specifications VFK1842 No. 1 2 Video signal Moving image Audio signal Moving image audio Time (min.) 10 10 Applications Block noise check ·Interchangeability adjustment ·Video/audio play circuit check/adjustment

B Vp-p

Y/C (C) NTSC : A = 0.286, B = 0.84 [SETUP 7.5%] (0.9 [SETUP 0%]) PAL : A = 0.3, B = 0.885

Color bars 1 kHz

B Vp-p A Vp-p

Table 3-1-2

Fig. 3.1.3 (2) 3-1

3.1.4 Notes for adjustments Since the AG-DV2500 is compatible with the recording and playback of the NTSC and PAL signals, it is required that both NTSC and PAL be adjusted. The NTSC and PAL signals use different Y signal V/S ratios and color levels. Be sure to use the specified signals for the adjustments. Both the NTSC and PAL signals use a variety of signals differing in the Y levels and color levels, etc. Also note that the NTSC signals include signals both with and without the Setup component. The AG-DV2500 is provided with input and output level adjustment capabilities only. If a signal of the specified level for color and setup is not available, read the following for the substitution. (1) Y level adjustments (Both of NTSC and PAL) If the available Y signal contains a white level of 100 IRE (PAL: 0.7 Vp-p), the signal can be used in the adjustment as described in the given procedure. If the input signal has the setup, adjust the luminance level from the pedestal to the white peak including the setup. (2) Setup level adjustment (NTSC only) The NTSC signal generator usually generates a signal with the Setup component. If it cannot be switched off, follow the alternative adjustment procedure for the signal with Setup, which is provided for each adjustment item. (3) Color level adjustments (Both of NTSC and PAL) The chroma level is variable depending on whether it is 75% or 100% and on whether the Setup component is present (NTSC only). As a result, a correct adjustment is not possible unless the specified signal is used. If the specified signal is not available, refer to the following. · Chroma level adjustment First measure the input signal what the signal type is (Refer to the table 3.1.4). Then apply the signal (composite or Y/C) to the AG-DV2500 and adjust the output signal level equal to the input type level. · Burst level adjustment The burst level is identical for all signals. There will be no problem if it can be adjusted to NTSC: 0.286 Vp-p (PAL: 0.3 Vp-p). There is no problem whether or not the Setup component is present (NTSC only).

3.1.5 Adjustment menu (1) Operation method Use the ADJUST MENU for adjustments. The operating method is as follows.
1

2 3 4

Make sure of no cassette in the VTR. While holding the [REW] and [FF] buttons, press the [OPERATE] button to turn the unit on. When the unit is turned on, press and hold the [EJECT] button for about 2 seconds until the ADJUST MENU is displayed. Press the (FF) or (REW) button to select adjustment item. Press the [SET] (PAUSE) button so that the "*" marking blinks and, while observing the specified TP, the measuring instrument and others, press the (PLAY) button or (STOP) button to adjust the value to the specified value. (Pressing the [A.DUB] button simultaneously with the or button varies the adjustment value by 10 steps.)
­­­ A D J U S T ME NU SP : : : V CO 0 8DFH 0 8DFH 0 8DFH ­­­

1 0 6 . ME VR DATA CT L DATA SE T DATA

*

Adjusting marking Potentiometer value D/A output value Currently set adjustment value

CH 1 CH 2

65535 65535

Pressing the [SET] button causes the value being adjusted with the potentiometer to be the adjustment value.

After completing the adjustment, press the [SET] (PAUSE) button again to turn the "*" marking off and store the adjustment value. (The adjustment value is not stored and moving to the next adjustment item can not be performed unless the [SET] (PAUSE) button is pressed.) (FF) or (REW) button to select the next ad6 Press the justment item. Notes: · When the adjustment procedure requires a mode transition to PLAY, etc., use the accessory of wireless remote controller. · After completing all of the required settings, press [OPERATE] button to turn off the power. · To return to normal operating status, tur n the unit off then on again. If this is not performed, since the unit is turned on in the adjustment mode, pressing the MENU button displays an adjustment menu and it is not possible to display the normal operation menu.
5

[NTSC] Type Y 100%, color 100% level, setup 0% Y 100%, color 100% level, setup 7.5% Y 100%, color 75% level, setup 0% Y 100%, color 75% level, setup 7.5% Y level [mVp-p] 1000 1000 1000 1000 White [mV] 714 714 714 714 Sync [mV] 286 286 286 286 Setup [mV] 0 53.6 0 53.6 Burst [mVp-p] 286 286 286 286 YL/B [mVp-p] 640 592 480 444 CY/R [mVp-p] 908 836 681 627 G/MG [mVp-p] 848 780 636 585

3-2

[PAL] Type Y 100%, color 100% level Y 100%, color 75% level Y level [mVp-p] 1000 1000 White [mV] 700 700 Sync [mV] 300 300 Burst [mVp-p] 300 300 YL/B [mVp-p] 627 471 CY/R [mVp-p] 885 664 G/MG [mVp-p] 827 620

YL/B: Yellow and Blue level. CY/R: Cyan and Red level. G/MG: Green and Magenta level. Table 3.1.4 (2) Adjustment items and initial data The initial values are merely the typical values, which are written automatically after the EEP-ROM replacement, etc. As the adjustments will not be correct if these values are left, be sure to perform actual adjustments before use. The hatched rows in the following table indicate that adjustments are not necessary, so do not change the value of the initial settings. Adjustment item (OSD characters) Initial value (CTL DATA) 121 0890(Hex) 0892(Hex) 25 83 25 143 110 132 68 128 18 192 192 72 53 129 192 89 95 205 94 9 0 92 8 0 96 174 95 Adjustment item (OSD characters) Initial value (CTL DATA) 152 119 201 118 87 200 94 34 1 91 31 2 95 172 96 149 127 0 94 95 29 104 3 -16 101 2 -16 94 233 93 206

No.

Adjustment range

No.

Adjustment range 0~255 0~255 192~207 0~255 0~255 0~255 0~255 0~127 -16~15 0~255 0~127 -16~15 0~255 0~255 0~255 0~255 0~255 0~16 0~255 0~255 0~255 0~255 0~127 -16~15 0~255 0~127 -16~15 0~255 0~255 0~255 0~255

100 PB SW POINT 105 ME REC CURRENT 106 ME SP VCO 107 ME LP VCO 110 FS PLL 48kHz 111 FS PLL 44.1kHz 112 FS PLL 32kHz 113 27MHz VCO 114 ATF GAIN 115 AGC GAIN 116 DUMP CTL 117 PB VCO 118 BGNEND SENS 119 FWD TORQUE 120 REV TORQUE 121 UNLOAD TORQUE 200 OSD ADJ 210 PB Y LEV(S OFF) 211 PB SETUP LEV(S OFF) 212 PB SYNC LEV(S OFF) 213 PB C LEV(S OFF) 214 PB BUR LEV(S OFF) 215 YC REC Y LEV(S OFF) 216 YC REC ST LV(S OFF) 217 YC REC C LEV(S OFF) 218 LE REC Y LEV(S OFF) 219 LE REC ST LV(S OFF) 220 LE REC C LEV(S OFF) 221 YC EE Y LEV(S OFF) 222 YC EE C LEV(S OFF) 223 LE EE Y LEV(S OFF)

Auto adjustment 0000H~FFFFH 0~255 0000H~FFFFH 0000H~FFFFH 0~255 0~255 0~255 0~255 0~255 0~255 0~255 0~255 0~255 0~255 0~255 0~255 0~255 0~255 192~207 0~255 0~255 0~255 0~255 0~127 -16~15 0~255 0~127 -16~15 0~255 0~255 0~255

224 LE EE C LEV(S OFF) 230 PB Y LEV(S ON) 231 PB SETUP LEV(S ON) 232 PB SYNC LEV(S ON) 233 PB C LEV(S ON) 234 PB BUR LEV(S ON) 235 YC REC Y LEV(S ON) 236 YC REC ST LV(S ON) 237 YC REC C LEV(S ON) 238 LE REC Y LEV(S ON) 239 LE REC ST LV(S ON) 240 LE REC C LEV(S ON) 241 YC EE Y LEV(S ON) 242 YC EE C LEV(S ON) 243 LE EE Y LEV(S ON) 244 LE EE C LEV(S ON) 260 PB Y LEV(PAL) 261 PB SETUP LEV(PAL) 262 PB SYNC LEV(PAL) 263 PB C LEV(PAL) 264 PB BUR LEV(PAL) 265 YC REC Y LEV(PAL) 266 YC REC ST LV(PAL) 267 YC REC C LEV(PAL) 268 LE REC Y LEV(PAL) 269 LE REC ST LV(PAL) 270 LE REC C LEV(PAL) 271 YC EE Y LEV(PAL) 272 YC EE C LEV(PAL) 273 LE EE Y LEV(PAL) 274 LE EE C LEV(PAL)

Table 3.1.5 Adjustment menu items

3-3

3.2

DVC UNIT ADJUSTMENTS

Preparation : Connect the Rewrite board (VFK1846) to CN4004 on the Main board. Connect it in the orientation shown in Fig. 3.2, so that the test point surface (component mounting surface) faces toward the rear. NOTE : DVC UNIT ADJUSTMENTS can be completed if NTSC mode is performed. Set the NTSC/PAL switch of the rear panel to NTSC.

REWRITE board

Fig. 3.2 Rewrite board connection method

No.

Item

Measuring instruments & Input signals Alignment tape, VFK1842 color bar recorded section

Mode

Measuring point ( Adjustment parts ( Adjustment level ( TP6 (SPA) TP9 (ENV OUT) TRIG: TP5 (HID) GND: TP1 (GND) [Rewrite board] Auto adjustment a and b = 126 µ sec 10 µ sec

) ) )

Adjustment procedure

1

PB switching point adjustment

· PLAY · ADJUST MENU, 100. PB SW POINT

(1)Select ADJUST MENU No. 100, "PB SW POINT". (2)Playback the alignment tape. Confirm that the compatibility adjustment has been performed and the FM waveform at TP9 (ENV OUT) is flat and stable. (3)Press the [ SET ] button to cause the * marking to blink. The PB switching point will be adjusted automatically.

HID (TP5)

a

b

SPA (TP6) ENV OUT (TP9) a, b : 126µ sec ±10µ sec

Fig. 3.2.1(1)

3-4

No.

Item

Measuring instruments & Input signals

Mode

Measuring point ( * ) Adjustment parts ( - ) Adjustment level ( + )

Adjustment procedure

­­­

A D J U S T ME NU
SW : : :

­­­

1 0 0 . PB VR DATA CT L DATA SET DATA

PO I NT ! - - - 120 120

(4) Measure TP6 (SPA) by triggering TP5 (HID) and confirm that the values a and b are within the specified ranges. (5) Press the [PLAY] button a few times to display the adjustment data in the "DATA:" field. (The DATA value should not be 00000000 or FFFFFFFF.) (6) Press the [SET] button to store the adjustment data. NOTE: Make sure that the data value is displayed before pressing the [SET] button. If this adjustment is completed before the data value is displayed the adjustment value will not be put into the memory.

DATA

:

00000000

Press the [PLAY] button a few times to display data. After displaying the data, press the [SET] button to complete the adjustment.

Fig. 3.2.1(2)

2

ME recording current adjustment

· EE · ADJUST MENU, 105. ME REC CURRENT

* Monitor display - [PLAY] and [STOP] buttons + SET DATA = 115

(1) Select ADJUST MENU No. 105, "ME REC CURRENT". (2) Check the set data so that the value is "115" (Recording current is approx. 360 mVp-p). If not, adjust the value to "115" (3) Press the [SET] button to store the adjustment data.

­­­

A D J U S T ME NU

­­­

1 0 5 . ME VR DATA CT L DATA SET DATA

REC CURREN T : : : 115 115 115

CH 1 CH 2

65535 65535

Fig. 3.2.2

3-5

No.

Item

Measuring instruments & Input signals

Mode

Measuring point ( Adjustment parts ( Adjustment level (

) ) )

Adjustment procedure

3

ME SP VCO offset adjustment (Error rate adjustment)

Recording tape · Self-REC/ (brand-new tape) PLAY · ADJUST MENU, 106. Moving Picture ME SP VCO

Monitor display [PLAY] and [STOP] buttons Minimum error rate, which should be 498 (per CH). (Viterbi : OFF)

(Notes) · Be sure to use a brand-new tape for the ME SP VCO offset adjustment. · Be sure to clean the head with a head cleaning tape before adjustment. · The error rate should be measured with the Viterbi OFF. The Viterbi is switched OFF automatically when the adjustment mode is entered. · The error rate value is displayed in decimal form. (1)Record a moving image in advance on the NEW recording tape for 5 minutes. (2)Select ADJUST MENU No. 106, "ME SP VCO". (3)Playback the recorded tape, press the [STOP] button to decrease the adjustment EVR data and freeze the image. (Pressing the [A.DUB] button simultaneously with the or button varies the adjustment value by 10 steps.) (4)Increase the EVR data gradually until the block noise just disappears. The current value is the adjustment value "A". (5)Playback the recorded tape and press the [PLAY] button to increase the EVR data and freeze the image. (6)Decrease the EVR data gradually until the block noise just disappears. The current value is the adjustment value "B". (7)Calculate the intermediate value between the "A" and "B" values. (Since the adjustment values are hex numbers, use a functional computation-capable calculator or the PC calculator provided in Accessories.) C = (A + B)/2 Set the value "C" as the adjustment value. (8)Playback the recorded tape again, confirm that the error rate is within specification. (9)Press the [SET] button to store the adjustment data.

­­­

A D J U S T ME NU SP : : :

­­­

1 0 6 . ME VR DATA CT L DATA SET DATA

V CO * 0 8DFH 0 8DFH 0 8DFH

Adjusted EVR data value

65535 65535

Error rate display Upper row : CH-1 Lower row : CH-2

Fig. 3.2.3 (1) SP VCO Offset Menu

Freeze the image Value A Error rate

Freeze the image Value B

Value C Adjustment Point

Decrease

VR DATA

Increase

Fig. 3.2.3 (2) Consept of the adjustment

3-6

No.

Item

Measuring instruments & Input signals Frequency counter No input

Mode

Measuring point ( Adjustment parts ( Adjustment level ( TP4 (FS PLL) GND: TP1 (GND) [Rewrite board] [PLAY] and [STOP] buttons 12.288 MHz 0.1 MHz

) ) )

Adjustment procedure

4

FS PLL 48 kHz adjustment

EE ADJUST MENU, 110. FS PLL 48 kHz

(1)Select ADJUST MENU No. 110, "FS PLL 48 kHz". (2)Press the [SET] button to measure frequency. (3)Adjust the frequency to the specified value. (4)Press the [SET] button to store the adjustment data.

5

FS PLL 44.1 kHz adjustment

Frequency counter No input

EE ADJUST MENU, 111. FS PLL 44.1 kHz

TP4 (FS PLL) GND: TP1 (GND) [Rewrite board] [PLAY] and [STOP] buttons 11.2896 MHz 0.1 MHz

(1)Select ADJUST MENU No. 111, "FS PLL 44.1 kHz". (2)Press the [SET] button to measure frequency. (3)Adjust the frequency to the specified value. (4)Press the [SET] button to store the adjustment data.

6

FS PLL 32 kHz adjustment

No input.

EE ADJUST MENU,112. FS PLL 32 kHz

Monitor display [PLAY] and [STOP] buttons Value adjusted in No. 110, "FS PLL 48 kHz" in item 4 above.

(1)Select ADJUST MENU No. 112, "FS PLL 32 kHz". (2)Press the [SET] button to measure frequency. (3)Adjust to the same value as the FS PLL 48 kHz adjustment value. (Setting range: 0 to 255) (4)Press the [SET] button to store the adjustment data.

7

27 MHz VCO center frequency adjustment

Frequency counter No input

EE ADJUST MENU,113. 27 MHz VCO

TP7 (MAIN VCO) GND: TP1 (GND) [Rewrite board] [PLAY] and [STOP] buttons 13.5 MHz 0.1 MHz

(1)Select ADJUST MENU No. 113, "27 MHz VCO". (2)Press the [SET] button to measure frequency. (3)Adjust the frequency to the specified value. (4)Press the [SET] button to store the adjustment data.

3-7

3.3

VIDEO SYSTEM ADJUSTMENTS

· Use NTSC signals for the NTSC adjustments and PAL signals for the PAL adjustments. · Use the specified signals to make adjustments whenever possible. When there are no specified signals, please refer to the "3.1.4 Notes for adjustments". · The monitor image may fluctuate horizontally during adjustments. This phenomenon occurs only in the adjustment mode and does not affect the adjustment results. · When an item is selected in the ADJUST MENU and INPUT SELECT SW sets to LINE or Y/C, the INPUT SELECT is switched automatically according to the selected item. If DV input is selected, disable automatic selection. (1) NTSC circuit adjustments Set the [NTSC/PAL] switch of rear panel to "NTSC". No. Item Measuring instruments & Input signals WFM (NTSC) or oscilloscope 100% WHITE (built-in signal) Mode Measuring point ( * ) Adjustment parts ( - ) Adjustment level ( + ) * Y OUT (Y/C jack) (75 ! terminated) - [PLAY] and [STOP] buttons + 100 IRE (714 mVp-p) Adjustment procedure

1

NTSC PB Y level adjustment (SETUP OFF)

EE ADJUST MENU, 210. PB Y LEV (S OFF)

(1) Set the INPUT SELECT SW to LINE or Y/C. (2) Select ADJUST MENU No. 210, "PB Y LEV (S OFF)". (3) Adjust so that the level from the pedestal to 100% WHITE is as specified. (4) Press the [SET] button to store the adjustment data.

100 IRE (714mVp-p)

2

NTSC PB SYNC level adjustment (SETUP OFF)

WFM (NTSC) or oscilloscope 100% WHITE (built-in signal)

EE ADJUST MENU, 212. PB SYNC LEV (S OFF)

* Y OUT (Y/C jack) (75 ! terminated) - [PLAY] and [STOP] buttons + 40 IRE (286 mVp-p)

(1) Set the INPUT SELECT SW to LINE or Y/C. (2) Select ADJUST MENU No. 212, "PB SYNC LEV (S OFF)". (3) Adjust so that the level from the pedestal to the sync tip is as specified. (4) Press the [SET] button to store the adjustment data.

40 IRE (286mVp-p)

3

NTSC PB Chroma level adjustment (SETUP OFF)

WFM (NTSC) or oscilloscope RED raster (builtin signal)

EE ADJUST MENU, 213. PB C LEV (S OFF)

* C OUT (Y/C jack) (75 ! terminated) - [PLAY] and [STOP] buttons + 908 mVp-p

(1) Set the INPUT SELECT SW to LINE or Y/C. (2) Select ADJUST MENU No. 213, "PB C LEV (S OFF)". (3) Adjust so that the chroma level is as specified. (4) Press the [SET] button to store the adjustment data.

908mVp-p

3-8

No.

Item

Measuring instruments & Input signals WFM (NTSC) or oscilloscope RED raster (builtin signal)

Mode

Measuring point ( Adjustment parts ( Adjustment level (

) ) )

Adjustment procedure

4

NTSC PB BURST level adjustment (SETUP OFF)

EE ADJUST MENU, 214. PB BUR LEV (S OFF)

C OUT (Y/C jack) (75 terminated) [PLAY] and [STOP] buttons 40 IRE (286 mVp-p)

(1)Set the INPUT SELECT SW to LINE or Y/C. (2)Select ADJUST MENU No. 214, "PB BUR LEV (S OFF)". (3)Adjust so that the burst level is as specified. (4)Press the [SET] button to store the adjustment data.

40 IRE (286mVp-p)

5

NTSC Y/C IN REC Y level adjustment (SETUP OFF)

WFM (NTSC) or oscilloscope Y/C IN. NTSC 100% color bar (SETUP 0%)

EE ADJUST MENU, 215. YC REC Y LEV (S OFF)

Y OUT (Y/C jack) (75 terminated) [PLAY] and [STOP] buttons 100 IRE (714 mVp-p)

(1)Set the INPUT SELECT SW to LINE or Y/C. (2)Select ADJUST MENU No. 215, "YC REC Y LEV (S OFF)". (3)Adjust so that the level from the pedestal to 100% WHITE is as specified. (4)Press the [SET] button to store the adjustment data.

100 IRE (714mVp-p)

6

NTSC Y/C IN REC SETUP level adjustment (SETUP OFF)

WFM (NTSC) or oscilloscope Y/C IN. NTSC 100% color bar (SETUP 0%)

EE ADJUST MENU, 216. YC REC ST LV (S OFF)

Y OUT (Y/C jack) (75 terminated) [PLAY] and [STOP] buttons 0 6 mV of the pedestal level

(1)Set the INPUT SELECT SW to LINE or Y/C. (2)Select ADJUST MENU No. 216, "YC REC ST LV (S OFF)". (3)Adjust so that the setup level is as specified. (4) Press the [SET] button to store the adjustment data. (5)Check ADJUST MENU No. 215, "YC REC Y LEV (S OFF)". If it is deviated, adjust it again. Reference: If a 7.5% setup signal should be used, the same effect as this adjustment can be obtained by adjusting the setup level to 53.6 mV ± 6 mV . Note: Adjust the setup level by decreasing it from + side, and stop decreasing when it just reaches 0.

0 6mV of the pedestal level (Note)

53.6mV 6mV

Adjustment without setup

Adjustment with setup

3-9

No.

Item

Measuring instruments & Input signals WFM (NTSC) or oscilloscope Y/C IN. NTSC 100% color bar (SETUP 0%)

Mode

Measuring point ( Adjustment parts ( Adjustment level (

) ) )

Adjustment procedure

7

NTSC Y/C IN REC C level adjustment (SETUP OFF)

EE ADJUST MENU, 217. YC REC C LEV (S OFF)

C OUT (Y/C jack) (75 terminated) [PLAY] and [STOP] buttons 908 mVp-p (RED)

908mVp-p 836mVp-p, adjustment with setup

(1)Set the INPUT SELECT SW to LINE or Y/C. (2)Select ADJUST MENU No. 217, "YC REC C LEV (S OFF)". (3)Adjust so that the RED color levels are as specified. (4)Press the [SET] button to store the adjustment data. Reference: If 7.5% signal setup should be used, the same effect as this adjustment can be obtained by adjusting the color level to 836 mV p-p (100% color).

8

NTSC LINE IN REC Y level adjustment (SETUP OFF)

WFM (NTSC) or oscilloscope LINE IN. NTSC 100% color bar (SETUP 0%)

EE ADJUST MENU, 218. LE REC Y LEV (S OFF)

Y OUT (Y/C jack) (75 terminated) [PLAY] and [STOP] buttons 100 IRE (714 mVp-p)

(1)Set the INPUT SELECT SW to LINE or Y/C. (2)Select ADJUST MENU No. 218, "LE REC Y LEV (S OFF)". (3)Adjust so that the level from the pedestal to 100% WHITE is as specified. (4)Press the [SET] button to store the adjustment data.

100 IRE (714mVp-p)

9

NTSC LINE IN REC SETUP level adjustment (SETUP OFF)

WFM (NTSC) or oscilloscope LINE IN. NTSC 100% color bar (SETUP 0%)

EE ADJUST MENU, 219. LE REC ST LV (S OFF)

Y OUT (Y/C jack) (75 terminated) [PLAY] and [STOP] buttons 0 ± 6 mV of the pedestal level

(1)Set the INPUT SELECT SW to LINE or Y/C. (2)Select ADJUST MENU No. 219, "LE REC ST LV (S OFF)". (3)Adjust so that the setup level is as specified. (4)Press the [SET] button to store the adjustment data. (5)Check ADJUST MENU No. 218, "LE REC Y LEV (S OFF)". If it is deviated, adjust it again. Reference: If 7.5% signal setup should be used, the same effect as this adjustment can be obtained by adjusting the setup level to 53.6 mV ± 6 mV . Note: Adjust the setup level by decreasing it from + side, and stop decreasing when it just reaches 0.

0 ± 6mV of the pedestal level (Note)

53.6mV i± 6mV

Adjustment without setup

Adjustment with setup

3-10

No.

Item

Measuring instruments & Input signals WFM (NTSC) or oscilloscope LINE IN. NTSC 100% color bar (SETUP 0%)

Mode

Measuring point ( * ) Adjustment parts ( - ) Adjustment level ( + ) * C OUT (Y/C jack) (75 ! terminated) - [PLAY] and [STOP] buttons + 908 mVp-p (RED)

Adjustment procedure

10

NTSC LINE IN REC C level adjustment (SETUP OFF)

EE ADJUST MENU, 220. LE REC C LEV (S OFF)

(1) Set the INPUT SELECT SW to LINE or Y/C. (2) Select ADJUST MENU No. 220, "LE REC C LEV (S OFF)". (3) Adjust so that the RED color levels are as specified. (4) Press the [SET] button to store the adjustment data. Reference: If 7.5% signal setup should be used, the same effect as this adjustment can be obtained by adjusting the color level to 836 mV p-p (100% color).

908mVp-p

11

NTSC Y/C IN EE Y level adjustment (SETUP OFF)

WFM (NTSC) or oscilloscope Y/C IN. NTSC 100% color bar (SETUP 0%)

EE ADJUST MENU, 221. YC EE Y LEV (S OFF)

* Y OUT (Y/C jack) (75 ! terminated) - [PLAY] and [STOP] buttons + 100 IRE (714 mVp-p)

(1) Set the INPUT SELECT SW to LINE or Y/C. (2) Select ADJUST MENU No. 221, "YC EE Y LEV (S OFF)". (3) Adjust so that the level from the pedestal to 100% WHITE is as specified. (4) Press the [SET] button to store the adjustment data. Reference: If a 7.5% setup signal should be used, the same effect as this adjustment can be obtained by simply ignoring the setup level.

100 IRE (714mVp-p)

12

NTSC Y/C IN EE C level adjustment (SETUP OFF)

WFM (NTSC) or oscilloscope Y/C IN. NTSC 100% color bar (SETUP 0%)

EE ADJUST MENU, 222. YC EE C LEV (S OFF)

* C OUT (Y/C jack) (75 ! terminated) - [PLAY] and [STOP] buttons + 40 IRE (286 mVp-p)

(1) Set the INPUT SELECT SW to LINE or Y/C. (2) Select ADJUST MENU No. 222, "YC EE C LEV (S OFF)". (3) Adjust so that the burst levels are as specified. (4) Press the [SET] button to store the adjustment data.

40IRE

286mVp-p

3-11

No.

Item

Measuring instruments & Input signals WFM (NTSC) or oscilloscope LINE IN. NTSC 100% color bar (SETUP 0%)

Mode

Measuring point ( * ) Adjustment parts ( - ) Adjustment level ( + ) * Y OUT (Y/C jack) (75 ! terminated) - [PLAY] and [STOP] buttons + 100 IRE (714 mVp-p)

Adjustment procedure

13

NTSC LINE IN EE Y level adjustment (SETUP OFF)

EE ADJUST MENU, 223. LE EE Y LEV (S OFF)

(1) Set the INPUT SELECT SW to LINE or Y/C. (2) Select ADJUST MENU No. 223, "LE EE Y LEV (S OFF)". (3) Adjust so that the level from the pedestal to 100% WHITE is as specified. (4) Press the [SET] button to store the adjustment data. Reference: If a 7.5% setup signal should be used, the same effect as this adjustment can be obtained by simply ignoring the setup level.

100 IRE (714mVp-p)

14

NTSC LINE IN EE C level adjustment (SETUP OFF)

WFM (NTSC) or oscilloscope LINE IN. NTSC 100% color bar (SETUP 0%)

EE ADJUST MENU, 224. LE EE C LEV (S OFF)

* C OUT (Y/C jack) (75 ! terminated) - [PLAY] and [STOP] buttons + 40 IRE (286 mVp-p)

(1) Set the INPUT SELECT SW to LINE or Y/C. (2) Select ADJUST MENU No. 224, "LE EE C LEV (S OFF)". (3) Adjust so that the burst levels are as specified. (4) Press the [SET] button to store the adjustment data.

40IRE

286mVp-p

15

NTSC PB Y level adjustment (SETUP ON)

WFM (NTSC) or oscilloscope 100% WHITE (built-in signal)

EE ADJUST MENU, 230. PB Y LEV (S ON)C LEV

* Y OUT (Y/C jack) (75 ! terminated) - [PLAY] and [STOP] buttons + 100 IRE (714 mVp-p)

(1) Set the INPUT SELECT SW to LINE or Y/C. (2) Select ADJUST MENU No. 230, "PB Y LEV (S ON)". (3) Adjust so that the level from the pedestal to 100% WHITE is as specified. (4) Press the [SET] button to store the adjustment data.

100 IRE (714mVp-p)

3-12

No.

Item

Measuring instruments & Input signals WFM (NTSC) or oscilloscope BLACK BURST (built-in signal)

Mode

Measuring point ( * ) Adjustment parts ( - ) Adjustment level ( + )

Adjustment procedure

16

NTSC PB SETUP level adjustment (SETUP ON)

* Y OUT (Y/C jack) (75 ! EE ADJUST terminated) MENU, 231. - [PLAY] and [STOP] PB SETUP LEV buttons (S ON) + 53.6 mVp-p

53.6mVp-p

(1) Set the INPUT SELECT SW to LINE or Y/C. (2) Select ADJUST MENU No. 231, "PB SETUP LEV (S ON)". (3) Adjust so that the SETUP levels are as specified. (4) Press the [SET] button to store the adjustment data. (5) Check ADJUST MENU No. 230, "PB Y LEV (S ON)" in item 15. If it is deviated, adjust it again.

17

NTSC PB SYNC level adjustment (SETUP ON)

WFM (NTSC) or oscilloscope 100% WHITE (built-in signal)

EE ADJUST MENU, 232. PB SYNC LEV (S ON)

* Y OUT (Y/C jack) (75 ! terminated) - [PLAY] and [STOP] buttons + 40 IRE (286 mVp-p)

(1) Set the INPUT SELECT SW to LINE or Y/C. (2) Select ADJUST MENU No. 232, "PB SYNC LEV (S ON)". (3) Adjust so that the sync level is as specified. (4) Press the [SET] button to store the adjustment data.

40 IRE (286mVp-p)

18

NTSC PB C level adjustment (SETUP ON)

WFM (NTSC) or oscilloscope RED raster (built-in signal)

EE ADJUST MENU, 233. PB C LEV (S ON)

* C OUT (Y/C jack) (75 ! terminated) - [PLAY] and [STOP] buttons + 836 mVp-p

(1) Set the INPUT SELECT SW to LINE or Y/C. (2) Select ADJUST MENU No. 233, "PB C LEV (S ON)". (3) Adjust so that the RED color level is as specified. (4) Press the [SET] button to store the adjustment data.

836mVp-p

3-13

No.

Item

Measuring instruments & Input signals WFM (NTSC) or oscilloscope RED raster (builtin signal)

Mode

Measuring point ( Adjustment parts ( Adjustment level (

) ) )

Adjustment procedure

19

NTSC PB BURST level adjustment (SETUP ON)

EE ADJUST MENU, 234. PB BUR LEV (S ON)

C OUT (Y/C jack) (75 terminated) [PLAY] and [STOP] buttons 40 IRE (286 mVp-p)

(1)Set the INPUT SELECT SW to LINE or Y/C. (2)Select ADJUST MENU No. 234, "PB BUR LEV (S ON)". (3)Adjust so that the burst level is as specified. (4)Press the [SET] button to store the adjustment data.

40 IRE (286mVp-p)

20

NTSC Y/C In REC Y level adjustment (SETUP ON)

WFM (NTSC) or oscilloscope Y/C IN. NTSC 100% color bar (Setup 7.5%)

EE ADJUST MENU, 235. YC REC Y LEV (S ON)

Y OUT (Y/C jack) (75 terminated) [PLAY] and [STOP] buttons 100 IRE (714 mVp-p)

(1) Set the INPUT SELECT SW to LINE or Y/C. (2) Select ADJUST MENU No. 235, "YC REC Y LEV (S ON)". (3) Adjust so that the level from the pedestal to 100% WHITE is as specified. (4)Press the [SET] button to store the adjustment data.

100 IRE (714mVp-p)

21

NTSC Y/C IN REC SETUP level adjustment (SETUP ON)

WFM (NTSC) or oscilloscope Y/C IN. NTSC 100% color bar (Setup 7.5%)

EE ADJUST MENU, 236. YC REC ST LV (S ON)

Y OUT (Y/C jack) (75 terminated) [PLAY] and [STOP] buttons 0 ± 6 mV of the pedestal level

(1)Set the INPUT SELECT SW to LINE or Y/C. (2)Select ADJUST MENU No. 236, "YC REC ST LV (S ON)". (3)Adjust so that the setup level is as specified. (4)Press the [SET] button to store the adjustment data. (5)Check ADJUST MENU No. 235, "YC REC Y LEV (S ON)" in item 20 above. If it is deviated, adjust it again. Note: Adjust the setup level by decreasing it from + side, and stop decreasing when it just reaches 0.

0 ± 6mV of the pedestal level (Note)

3-14

No.

Item

Measuring instruments & Input signals WFM (NTSC) or oscilloscope Y/C IN. NTSC 100% color bar (Setup 7.5%)

Mode

Measuring point ( Adjustment parts ( Adjustment level (

) ) )

Adjustment procedure

22

NTSC Y/C IN REC SETUP level adjustment (SETUP ON)

EE ADJUST MENU, 237. YC REC C LEV (S ON)

C OUT (Y/C jack) (75 terminated) [PLAY] and [STOP] buttons 836 mVp-p (RED)

(1)Set the INPUT SELECT SW to LINE or Y/C. (2)Select ADJUST MENU No. 237, "YC REC C LEV (S ON)". (3)Adjust so that the RED color levels are as specified. (4)Press the [SET] button to store the adjustment data.

836mVp-p

23

NTSC LINE IN REC Y level adjustment (SETUP ON)

WFM (NTSC) or oscilloscope LINE IN. NTSC 100% color bar (Setup 7.5%)

EE ADJUST MENU, 238. LE REC Y LEV (S ON)

Y OUT (Y/C jack) (75 terminated) [PLAY] and [STOP] buttons 100 IRE (714 mVp-p)

(1)Set the INPUT SELECT SW to LINE or Y/C. (2)Select ADJUST MENU No. 238, "LE REC Y LEV (S ON)". (3)Adjust so that the difference from the pedestal to 100% WHITE is as specified. (4)Press the [SET] button to store the adjustment data.

100 IRE (714mVp-p)

24

NTSC LINE IN REC SETUP level adjustment (SETUP ON)

WFM (NTSC) or oscilloscope LINE IN. NTSC 100% color bar (Setup 7.5%)

EE ADJUST MENU, 239. LE REC ST LV (S ON)

Y OUT (Y/C jack) (75 terminated) [PLAY] and [STOP] buttons 0 ± 6 mV of the pedestal level

(1)Set the INPUT SELECT SW to LINE or Y/C. (2)Select ADJUST MENU No. 239, "LE REC ST LV (S ON)". (3)Adjust so that the setup level is as specified. (4)Press the [SET] button to store the adjustment data. Note: Adjust the setup level by decreasing it from + side, and stop decreasing when it just reaches 0.

0 ± 6mV of the pedestal level (Note)

3-15

No.

Item

Measuring instruments & Input signals WFM (NTSC) or oscilloscope LINE IN. NTSC 100% color bar (SET UP 7.5 %)

Mode

Measuring point ( * ) Adjustment parts ( - ) Adjustment level ( + ) * C OUT (Y/C jack) (75 ! terminated) - [PLAY] and [STOP] buttons + 836 mVp-p (RED)

Adjustment procedure

25

NTSC LINE IN REC C level adjustment (SETUP ON)

EE ADJUST MENU, 240. LE REC C LEV (S ON)

(1) Set the INPUT SELECT SW to LINE or Y/C. (2) Select ADJUST MENU No. 240, "LE REC C LEV (S ON)". (3) Adjust so that the RED color levels are as specified. (4) Press the [SET] button to store the adjustment data.

836mVp-p

26

NTSC Y/C IN EE Y level adjustment (SETUP ON)

WFM (NTSC) or oscilloscope Y/C IN. NTSC 100% color bar (Setup 7.5%)

EE ADJUST MENU, 241. YC EE Y LEV (S ON)

* Y OUT (Y/C jack) (75 ! terminated) - [PLAY] and [STOP] buttons + 100 IRE (714 mVp-p)

(1) Set the INPUT SELECT SW to LINE or Y/C. (2) Select ADJUST MENU No. 241, "YC EE Y LEV (S ON)". (3) Adjust so that the level from the pedestal to 100% WHITE is as specified. (4) Press the [SET] button to store the adjustment data.

100 IRE (714mVp-p)

27

NTSC Y/C IN EE C level adjustment (SETUP ON)

WFM (NTSC) or oscilloscope Y/C IN. NTSC 100% color bar (Setup 7.5%)

EE ADJUST MENU, 242. YC EE C LEV (S ON)

* C OUT (Y/C jack) (75 ! terminated) - [PLAY] and [STOP] buttons + 40 IRE (286 mVp-p)

(1) Set the INPUT SELECT SW to LINE or Y/C. (2) Select ADJUST MENU No. 242, "YC EE C LEV (S ON)". (3) Adjust so that the burst levels are as specified. (4) Press the [SET] button to store the adjustment data.

40IRE

286mVp-p

3-16

No.

Item

Measuring instruments & Input signals WFM (NTSC) or oscilloscope LINE IN. NTSC 100% color bar (Setup 7.5%)

Mode

Measuring point ( * ) Adjustment parts ( - ) Adjustment level ( + ) * Y OUT (Y/C jack) (75 ! terminated) - [PLAY] and [STOP] buttons + 100 IRE (714 mVp-p)

Adjustment procedure

28

NTSC LINE IN EE Y level adjustment (SETUP ON)

EE ADJUST MENU, 243. LE EE Y LEV (S ON)

(1) Set the INPUT SELECT SW to LINE or Y/C. (2) Select ADJUST MENU No. 243, "LE EE Y LEV (S ON)". (3) Adjust so that the level from the pedestal to 100% WHITE is as specified. (4) Press the [SET] button to store the adjustment data.

100 IRE (714mVp-p)

29

NTSC LINE IN EE C level adjustment (SETUP ON)

WFM (NTSC) or oscilloscope LINE IN. NTSC 100% color bar (Setup 7.5%)

EE ADJUST MENU, 244. LE EE C LEV (S ON)

* C OUT (Y/C jack) (75 ! terminated) - [PLAY] and [STOP] buttons + 40 IRE (286 mVp-p)

(1) Set the INPUT SELECT SW to LINE or Y/C. (2) Select ADJUST MENU No. 244, "LE EE C LEV (S ON)". (3) Adjust so that the burst levels are as specified. (4) Press the [SET] button to store the adjustment data.

40IRE

286mVp-p

3-17

No.

Item

Measuring instruments & Input signals

Mode

Measuring point ( * ) Adjustment parts ( - ) Adjustment level ( + )

Adjustment procedure

(2) PAL circuit adjustments Set the [NTSC /PAL] switch of rear panel to "PAL". 30 PAL PB Y level adjustment WFM (PAL) or oscilloscope 100% WHITE (built-in signal) EE ADJUST MENU, 260. PB Y LEV (PAL) * Y OUT (Y/C jack) (75 ! terminated) - [PLAY] and [STOP] buttons + 700 mVp-p (1) Set the INPUT SELECT SW to LINE or Y/C. (2) Select ADJUST MENU No. 260, "PB Y LEV (PAL)". (3) Adjust so that the level from the pedestal to 100% WHITE is as specified. (4) Press the [SET] button to store the adjustment data. Note: When this item is selected after an NTSC adjustment item, the built-in 100% WHITE signal may sometimes be unable to be output. In this case, select No. 262, "PB SYNC LEV (PAL)" and then select No. 260, "PB Y LEV (PAL)" again.

700mVp-p

31

PAL PB SYNC WFM (PAL) or oscilloscope level adjust100% WHITE ment (built-in signal)

EE ADJUST MENU, 262. PB SYNC LEV (PAL)

* Y OUT (Y/C jack) (75 ! terminated) - [PLAY] and [STOP] buttons + 300 mVp-p

(1) Set the INPUT SELECT SW to LINE or Y/C. (2) Select ADJUST MENU No. 262, "PB SYNC LEV (PAL)". (3) Adjust so that the sync level is as specified. (4) Press the [SET] button to store the adjustment data.

300mVp-p

32

PAL PB C level adjustment

WFM (PAL) or oscilloscope RED raster (builtin signal)

EE ADJUST MENU, 263. PB C LEV (PAL)

* C OUT (Y/C jack) (75 ! terminated) * [PLAY] and [STOP] buttons + 885 mVp-p

(1) Set the INPUT SELECT SW to LINE or Y/C. (2) Select ADJUST MENU No. 263, "PB C LEV (PAL)". (3) Adjust so that the color levels are as specified. (4) Press the [SET] button to store the adjustment data.

885mVp-p

3-18

No.

Item

Measuring instruments & Input signals WFM (PAL) or oscilloscope RED raster (builtin signal)

Mode

Measuring point ( Adjustment parts ( Adjustment level (

) ) )

Adjustment procedure

33

PAL PB BURST level adjustment

EE ADJUST MENU, 264. PB BUR LEV (PAL)

C OUT (Y/C jack) (75 terminated) [PLAY] and [STOP] buttons 300 mVp-p

(1)Set the INPUT SELECT SW to LINE or Y/C. (2)Select ADJUST MENU No. 264, "PB BUR LEV (PAL)". (3)Adjust so that the burst level is as specified. (4)Press the [SET] button to store the adjustment data.

300mVp-p

34

PAL Y/C IN REC Y level adjustment

WFM (PAL) or oscilloscope Y/C IN PAL 100% color bar

EE ADJUST MENU, 265. YC REC Y LEV (PAL)

Y OUT (Y/C jack) (75 terminated) [PLAY] and [STOP] buttons 700 mVp-p

(1)Set the INPUT SELECT SW to LINE or Y/C. (2)Select ADJUST MENU No. 265, "YC REC Y LEV (PAL)". (3)Adjust so that the level from the pedestal to 100% WHITE is as specified. (4)Press the [SET] button to store the adjustment data.

700mVp-p

35

PAL Y/C IN REC SETUP level adjustment

WFM (PAL) or oscilloscope Y/C IN PAL 100% color bar

EE ADJUST MENU, 266. YC REC ST LV (PAL)

Y OUT (Y/C jack) (75 terminated) [PLAY] and [STOP] buttons 0 ± 6 mV of the pedestal level

0 ± 6mV of the pedestal level (Note)

(1)Set the INPUT SELECT SW to LINE or Y/C. (2)Select ADJUST MENU No. 266, "YC REC ST LV (PAL)". (3)Adjust so that the setup level is as specified. (4)Press the [SET] button to store the adjustment data. (5)Check ADJUST MENU No. 265, "YC REC Y LEV (PAL)" in item 34 above. If it is deviated, adjust it again. Note: Adjust the setup level by decreasing it from + side, and stop decreasing when it just reaches 0.

3-19

No.

Item

Measuring instruments & Input signals WFM (PAL) or oscilloscope Y/C IN PAL 100% color bar

Mode

Measuring point ( Adjustment parts ( Adjustment level (

) ) )

Adjustment procedure

36

PAL Y/C IN REC C level adjustment

EE ADJUST MENU, 267. YC REC C LEV (PAL)

C OUT (Y/C jack) (75 terminated) [PLAY] and [STOP] buttons 885 mVp-p (RED)

(1)Set the INPUT SELECT SW to LINE or Y/C. (2)Select ADJUST MENU No. 267, "YC REC C LEV (PAL)". (3)Adjust so that the RED color levels are as specified. (4)Press the [SET] button to store the adjustment data.

885mVp-p

37

PAL LINE IN REC Y level adjustment

WFM (PAL) or oscilloscope LINE IN PAL 100% color bar

EE ADJUST MENU, 268. LE REC Y LEV (PAL)

Y OUT (Y/C jack) (75 terminated) [PLAY] and [STOP] buttons 700 mVp-p

(1)Set the INPUT SELECT SW to LINE or Y/C. (2)Select ADJUST MENU No. 268, "LE REC Y LEV (PAL)". (3)Adjust so that the level from the pedestal to 100% WHITE is as specified. (4)Press the [SET] button to store the adjustment data.

700mVp-p

38

PAL LINE IN REC SETUP level adjustment

WFM (PAL) or oscilloscope LINE IN PAL 100% color bar

EE ADJUST MENU, 269. LE REC ST LV (PAL)

Y OUT (Y/C jack) (75 terminated) [PLAY] and [STOP] buttons 0 ± 6 mV of the pedestal level

0 ± 6mV of the pedestal level (Note)

(1)Set the INPUT SELECT SW to LINE or Y/C. (2)Select ADJUST MENU No. 269, "LE REC ST LV (PAL)". (3)Adjust so that the setup level is as specified. (4)Press the [SET] button to store the adjustment data. (5)Check ADJUST MENU No. 268, "LE REC Y LEV (PAL)" in item 37 above. If it is deviated, adjust it again. Note: Adjust the setup level by decreasing it from + side, and stop decreasing when it just reaches 0.

3-20

No.

Item

Measuring instruments & Input signals WFM (PAL) or oscilloscope LINE IN PAL 100% color bar

Mode

Measuring point ( Adjustment parts ( Adjustment level (

) ) )

Adjustment procedure

39

PAL LINE IN REC C level adjustment

EE ADJUST MENU, 270. LE REC C LEV (PAL)

C OUT (Y/C jack) (75 terminated) [PLAY] and [STOP] buttons 885 mVp-p

(1)Set the INPUT SELECT SW to LINE or Y/C. (2)Select ADJUST MENU No. 270, "LE REC C LEV (PAL)". (3)Adjust so that the RED color levels are as specified. (4)Press the [SET] button to store the adjustment data.

885mVp-p

40

PAL Y/C IN EE Y level adjustment

WFM (PAL) or oscilloscope Y/C IN PAL 100% color bar

EE ADJUST MENU, 271. YC EE Y LEV (PAL)

Y OUT (Y/C jack) (75 terminated) [PLAY] and [STOP] buttons 700 mVp-p

(1)Set the INPUT SELECT SW to LINE or Y/C. (2)Select ADJUST MENU No. 271, "YC EE Y LEV (PAL)". (3)Adjust so that the level from the pedestal to 100% WHITE is as specified. (4)Press the [SET] button to store the adjustment data.

700mVp-p

41

PAL Y/C IN EE C level adjustment

WFM (PAL) or oscilloscope Y/C IN PAL 100% color bar

EE ADJUST MENU, 272. YC EE C LEV (PAL)

C OUT (Y/C jack) (75 terminated) [PLAY] and [STOP] buttons 300 mVp-p

(1)Set the INPUT SELECT SW to LINE or Y/C. (2)Select ADJUST MENU No. 272, "YC EE C LEV (PAL)". (3)Adjust so that the burst levels are as specified. (4)Press the [SET] button to store the adjustment data.

300mVp-p

3-21

No.

Item

Measuring instruments & Input signals WFM (PAL) or oscilloscope LINE IN PAL 100% color bar

Mode

Measuring point ( * ) Adjustment parts ( - ) Adjustment level ( + ) * Y OUT (Y/C jack) (75 ! terminated) - [PLAY] and [STOP] buttons + 700 mVp-p

Adjustment procedure

42

PAL LINE IN EE Y level adjustment

EE ADJUST MENU, 273. LE EE Y LEV (PAL)

(1) Set the INPUT SELECT SW to LINE or Y/C. (2) Select ADJUST MENU No. 273, "LE EE Y LEV (PAL)". (3) Adjust so that the level from the pedestal to 100% WHITE is as specified. (4) Press the [SET] button to store the adjustment data.

700mVp-p

43

PAL LINE IN EE C level adjustment

WFM (PAL) or oscilloscope LINE IN PAL 100% color bar

EE ADJUST MENU, 274. LE EE C LEV (PAL)

* C OUT (Y/C jack) (75 ! terminated) - [PLAY] and [STOP] buttons + 300 mVp-p

(1) Set the INPUT SELECT SW to LINE or Y/C. (2) Select ADJUST MENU No. 274, "LE EE C LEV (PAL)". (3) Adjust so that the burst levels are as specified. (4) Press the [SET] button to store the adjustment data.

300mVp-p

(3) On-screen display adjustment 44 On-screen display position adjustment Monitor TV Color EE ADJUST bar (built-in MENU, 200 signal) OSD ADJ * LINE OUT or Y/C OUT (75 ! terminated) - [PLAY] and [STOP] buttons + Between "3" and "4" 1/5 character (1) Set the INPUT SELECT SW to LINE or Y/C. (2) Select ADJUST MENU No. 200, "OSD ADJ". (3) Adjust so that the boundary between the Red and Blue color bars comes in the space between "4" on the second position from the right of the array of figures on the bottom of the screen and "3" on the third position. (4) Press the [SET] button to store the adjustment data.

456789012345
Red Blue

Adjust so that the boundary between the Red and Blue color bars comes in the space between "4" and "3".

3-22

3.4

REWRITE BOARD SCHEMATIC DIAGRAM

AG-DV2500

S1 Pin No. 1 2 3 4 5 6 Initial OFF OFF OFF OFF OFF OFF Parameter ON : Enable to rewrite VTR (MSD) ON : Enable to rewrite SYS CPU Not used ON : Enable to rewrite VTR (MSD) CPU ((Note) Not used Not used Not used

S2 Not used

S3

(Note : When rewriting the VTR (MSD) firmware, both of switch S1 - 1 and 4 should be set to "ON".

3-23