(4) Write method
Restrictions: Never write data of any other product. The EEPROM data includes adjustment values, etc. that are peculiar to that product: It is different for each product even if the model is the same. If you write the data of another product by mistake, rewrite the correct data. 1) Choose DATA INITIALIZE on the ADJUST MENU screen. 2) Click the EXECUTE button on ADJUST MENU screen to proceed with the DATA INITIALIZE MENU screen. 3) Choose Backup Data Write on the DATA INITIALIZE MENU screen. 4) Click the EXECUTE button on DATA INITIALIZE MENU screen to proceed with the WRITE FILE SELECT screen. 5) From WRITE FILE SELECT screen, select the folder and file in which the data has previously been backed up. This section refers to the folder and file as "EEP" and "backup.eep" for explanation. 6) Click the OPEN button on WRITE FILE SELECT screen to start writing. The progress status can be confirmed using the PROGRESS STATUS dialog. 7) When writing is complete, the INITIALIZATION FINISHED dialog will appear: Click the OK button in dialog to restore the DATA INITIALIZE MENU screen. 8) Click the RETURN button on DATA INITIALIZE MENU screen to restore the ADJUST MENU screen, and then perform adjustment according to "6-3-2 List of Adjustments Needed After Replacing Major Components".

ADJUST MENU screen
MANUAL ADJUSTMENT PROGRAM for SERVICE STATION

MODEL NAME: ××××
ADJUST MENU

DATA INITIALIZE VIDEO LEVEL BURST LEVEL SAMPLING PULSE AUTO FUCUS AUTO IRIS CONTROL MATRIX CHROMA GAIN SPOT NOISE LCD EVF

1

2
CONNECTION

EXECUTE

RETURN

DATA INITIALIZE MENU screen
Data Initialize

FILE MENU

Initial Data Write

Backup Data Write

3

Original Data Backup

8

4
CONNECTION

EXECUTE

RETURN

WRITE FILE SELECT screen
? Look in (T):

EEP

backup.eep

5

6
File name (N): File of type (T):

backup.eep

Open Cancel

*.eep

PROGRESS STATUS dialog
DATA INITIALIZE

PLEASE WAIT A MOMENT

INITIALIZATION FINISHED dialog
FINISHED FINISHED WRITING DATA OK

7