Text preview for : Vca30Hm-BULL2.pdf part of Sharp VC-A30 VC-A30 part#1
Back to : SHARP VC-A30_1.zip | Home
VCR2000 04 02
Month of Issue: Classification:
VIDEO TECHNICAL BULLETIN
MODELS VCT310HM VCA81HM VCT510HM VCA215HM VCA30HM VCA55HM VCA40HM VCA63HM VCA50HM VCH84HM
April 2000 White Page 1 of 1
VCA615HM VCH86HM
SYMPTOM Unit laces up in play or record mode then unlaces after a few seconds.
CAUSE
Loss of the drum FG pulse resulting in no head-switching signal.
ACTION
Replace the drum motor assembly using the part number given in the respective Service Manual.
Sharp Electronics (UK) Limited
Reference AVW14042000-1 Revision 1
White Carry out as required Yellow Carry out as required and whenever the unit comes in for service Red Carry out on all units