Adviser Pro automatic working flow and Error Messege Asviser Pro process is full automatic process. You can not use manual function (Suspend etc.).

1. Pull out the AC plug. 2. Keep pushing the OPEN/CLOSE button and insert the AC plug. After while, tray opens (About 20seconds). 3. Insert the CD ROM of Adviser Pro on the tray and close the tray. 4. Pull out the AC plug. 5. Keep pushing the STOP button and insert the AC Plug. After while, the system starts up (About 1 minute).

Please wait . . .

When HDD is broken, this cation may appear in this timing.

Checking HDD (with progress bar)

SMART self test is being done. (a few minutes)

Repiring HDD (with progress bar)

JVC file system is being repaired. (5-30 minites)

Checking file and directories (with progress bar)

Broken file and folder are bing serched and deleted. (some sec - some minutes)

Please wait . . .

Navigation data are checked. (some sec - 1minute)

Checking disc to update firmware.

Firmware update file in CD-ROM is bing checked. (some sec - 1 minute)

Updating firmware (with progress bar)

Firmware of unit is being updated. (some minites)

HDD was repaired successfully Remove disc and push tray to close It will automatically restart system and then sleep

HDD data repair and firmawre update have been finished. This caution is being indicated until tray is closed. In this taiming, version of DRINE UNIT firmware is checked.

Restarting system . . .

System of unit is restarted. And then unit go to stanby mode.

error error message code 01 Found unmanageable error HDD S.M.A.R.T. self test failed 10 HDD is physically broken 11 Found problem on HDD 12 Found physical problem on HDD 13 Can't handle this HDD HDD S.M.A.R.T. data error found HDD is physically broken HDD S.M.A.R.T. data error found 15 HDD is physically broken 20 Could not repair HDD 21 Could not repair HDD 14

detail Probably HDD or DIGITAL PWB ASS'Y or FLAT WIRE is not good. Result of S.M.A.R.T. test is not good. HDD must be replaced. Interfece between HDD and DIGITAL PWB ASS'Y is not good. Probably HDD or DIGITAL PWB ASS'Y or FLAT WIRE is not good. S.M.A.R.T. information is broken. HDD must be replaced. Interfece between HDD and DIGITAL PWB ASS'Y is not good. Probably HDD or DIGITAL PWB ASS'Y or FLAT WIRE is not good. S.M.A.R.T. information suggest hdd is not good. HDD must be replaced. S.M.A.R.T. information can not be read. HDD must be replaced. Drive format of HDD is broken and can not be restored. JVC file system of hdd is broken and can not be restored.

HDD was repaired successfully But found DVD drive's region code was wrong 50 Remove disc and push tray to close Region code of DVD DRIVE is not exact or is not set. It will automatically restart system and then sleep HDD was repaired successfully But found DVD drive's region code was wrong Region code of DVD DRIVE and region code of DIGITAL PWB 51 Remove disc and push tray to close ASS'Y It will automatically restart system do not match. and then sleep HDD was repaired successfully But DVD drive needs to update firmware 52 Remove disc and push tray to close It will automatically restart system and then sleep 60 Can't mount to this disc 61 Can't read this disc 62 Can't update firmware 63 Can't update firmware 64 Error found in updating firmware 65 Can't read this disc

Firmawre of DVD DRIVE side is old. Firmawre of DVD DRIVE side must be updated. DVD DRIVE can not read the Adiviser.Pro disc. Probably DVD DRIVE is no tgood. DVD DRIVE can not read the Adiviser.Pro disc. Probably Adviser.Pro disc is no tgood. OSD data can not be renewed. Probably DVD DRIVE or DIGITAL PWB ASS'Y is not good. Firm ware can not be renewed. Probably DVD DRIVE or DIGITAL PWB ASS'Y is not good. DVD DRIVE can not read the Adiviser.Pro disc. Probably Adviser.Pro disc is not good.