Text preview for : HarmanKardon-SUBTS18 actsub.pdf part of Harman/Kardon SUBTS18 active subwoofer



Back to : HarmanKardon-SUBTS18 acts | Home

harman/kardon

SUB-TS18
(HKTS 18 SUBWOOFER)

SERVICE MANUAL

harman/kardon, Inc. 250 Crossways Park Dr. Woodbury, New York 11797 Rev1 4/2007

SUB-TS18

harman/kardon

CONTENTS
BASIC SPECIFICATIONS . . . . . . . . . . . . ........................................... . . . 1 DETAILED SPECIFICATIONS. . . . . . . . . . . . . .. . . . . . . . . ....................... ...2 PACKAGING. . . . . . . . . . . . . .. . . . . . . ........................... . . . . .. . .. .. .. . . . . 4 CONTROLS & CONNECTIONS . . . . . . . . . . . . . .. . . . . . . . . ....................... 5 SPEAKER CONNECTIONS.............................................. . . .. . .. . . . .. . .. 6 OPERATION....... . . . . .. . . . . . . . .. .. . . . .. .. . . . . ....................................10 TEST PROCEDURE. . . . . . . . . . . ..........................................................11 UNIT EXPLODED VIEW. . . . ............... ................ .. ............ . . .. .. ... . ... . 12 AMPLIFIER EXPLODED VIEW. . . . ..................... . .. ............ . . .. . . .. . .... . 13 BLOCK DIAGRAM . . . . . . . . . . . . . .. . . . . . . .................. . . . . .. . .. . .. . . . . 14 DETAILED TROUBLESHOOTING...........................................................15 PCB DRAWINGS. .. . . . . . . . . . . . . . .. . . . . ......... . ............. . . . .. .. .. . .. . . . 16 ELECTRICAL PARTS LIST ............. .... . .. . . . ................................. ... . . 20 SEMICONDUCTOR PINOUTS . . . .. .. .. .. . . . .. . ...................................... .24 SCHEMATIC DIAGRAMS . . . . . . . . .. .. .. .. . . . .. . .................................... .25

SPECIFICATIONS
Amplifier Power (RMS) Driver Inputs 200 Watts 10" (254mm) woofer, Bass Reflex Enclosure Stereo Line Level, dedicated Subwoofer (LFE) and Speaker Level with gold-plated binding posts Speaker Level with gold-plated binding posts 35Hz ­ 120Hz (Filter switch ON) 35Hz ­ 450Hz (Filter switch OFF) 3-30 Volts AC/DC 18-7/8" x 13-3/8" x 13-3/8" (479mm x 340mm x 340mm) 35.1 lb/15.8kg

Outputs Frequency Response

External Trigger Input Voltage: Dimensions (H x W x D) Weight

Occasional refinements may be made to existing products without notice but will always meet or exceed original specifications unless otherwise stated.

1

SUB-TS18
HKTS 18 Sub 200W Powered Sub/ Plate Amp
LINE VOLTAGE US 120vac/60Hz Yes/No Yes Nonimal Specification Hi/Lo Line 108-132 Nom. 120 QA Test Limits Unit Vrms

harman/kardon

Notes Normal Operation

Parameter Amp Section

Unit

Conditions

Notes Bridge type amplifier, None of the speaker terminals must be connected to system GND at any time.

Type (Class AB, D, other) Load Impedance (speaker) Rated Output Power THD @ Rated Power THD @ 1 Watt DC Offset

D 3.5 200 0.08 0.15 5

n/a Ohms Watts % % mV-DC

n/a n/a 150 0.1 0.5 20

Nominal 50 - 250 Hz, 1 input driven, limiter off 22k filter 22k filter @ Speaker Outputs Measured at the speaker at speake output terminals on the amp board.

Damping factor Input Sensitivity Input Frequency Line (L&R) Input SUB (LFE) Input Speaker/Hi Level Input Hi Level Max. Input Voltage Signal to Noise Ratio SNR-A-Weighted SNR-unweighted SNR rel. 1W-unweighted Residual Noise Floor

16

n/a

10

Measured at amplifier board

50 220 125 3.4 32

Hz mVrms mVrms Vrms Vrms

n/a Nominal Freq. 154 - 308 To Rated Power 87 - 175 To Rated Power 2.4 - 4.8 30 To Rated Power Nominal Freq., Min. Volume

Single input driven SUB (LFE) input driven only (20 dB below Line In), Single input driven

85 62 64 1.2

dB dB dB mVrms

82 59 59 3.0

Residual Noise Floor Input Impedance Line Input (L, R,LFE) Speaker/Hi Level Input Filters L&R Fixed Low-Pass Filter SUB (LFE) Low pass Filter Subsonic filter (HPF) 3rd Order Limiter THD at Max. Output Power Features Auto - On -Off Selection Switch Phase Switch Filter On/Off Switch Volume Pot Taper (Lin/Log) Speaker Out 2-Color LED power indicator Power Switch Fuse Holder Input Configuration Line In (L,R) SUB (LFE) Speaker/Hi Level In

0.8

mVrms

2.0

relative to rated power relative to rated power relative to 1W Output Volume @max, using RMS reading DMM/VOM (or A/P) Volume @max, w/ A/P Swept Bandpass Measurement (Line freq.+ harmonics)

A-Weighting filter 22k filter 22k filter

10K 4.7K

ohms ohms

n/a n/a

Nominal Nominal

160 270 25

Hz Hz Hz

140 - 180 @ -6dB ref. 100Hz 240 - 300 @ -3dB ref. 100Hz 22 - 28 @ -3dB ref. 30Hz

3rd order fixed 2nd order fixed 3rd order fixed

2.0

%

5.0

YES 0-180 YES LOG YES YES YES YES

deg

functional functional functional functional functional functional functional functional

Refer to ATO section

A Taper Binding post connector L&R Blue: On, Amber: Stand-by

YES YES

functional functional

Dual RCA jack RCA jack

YES

functional

Binding post connector L&R

Signal Sensing (ATO) Auto-Turn-On (yes/no) ATO Input test frequency ATO Level Line & SUB Input ATO Level Speaker in ATO Turn-on time

YES 50 4.0 35 0.9

Hz mV mV sec.

functional Auto - on selection switch in Auto n/a " 2.0 - 6.0 " 20 - 50 " Amp connected and AC on, then functional input signal applied

2

SUB-TS18
Parameter Amp Section ATO Turn-OFF Time Power on Delay time Transients/Pops ATO Transient Turn-on Transient Turn-off Transient Efficiency Nonimal Specification Unit QA Test Limits Conditions Time before muting, after signal is removed

harman/kardon
Notes

12 3

minutes sec.

5 - 17

functional AC Power Applied

5 500 500

mV-peak mV-peak mV-peak

10 700 700

@ Speaker Outputs @ Speaker Outputs @ Speaker Outputs

AC Line cycled from OFF to ON AC Line cycled from ON to OFF

Stand-by Input Power Power Consumption @ rated power Protection

8 240

Watts Watts

12 250

@ nom. line voltage @ nom. line voltage

Maximum allowable input power under nominal input voltage and frequency, in stand-by mode (HOT or COLD operation). 200 Watts @ 3.5 ohms and nominal line voltage

Short Circuit Protection

YES

functional Direct short at output

Amplifier should resume operation after short circuit condition is removed. Any user accessible metal parts should always remain at 65 degree C or less for domestic version or 55 degree C or less for EU version. Relay or crowbar (for driver/fire protection), User-replacable fuse with UL/SEMCO rated holder.

Thermal Protection DC Offset Protection Primary Fuse Rating USA-Domestic

YES YES

functional functional DC present at Speaker Out leads

3.15

Amps

n/a

Type-T or Slo Blo (no DENTORI

3

SUB-TS18

harman/kardon

4

SUB-TS18

harman/kardon

SUB-TS18 SUBWOOFER AMPLIFIER PANEL CONTROLS AND CONNECTIONS

¡ Subwoofer-Level Control TM High-Cut (Low-Pass) Filter Switch £ External Trigger Input ¢ Audio-Sense On/Off Switch

Phase Switch § Line-Level Subwoofer (SUB) Input ¶ Line-Level Full-Range Inputs · Speaker-Level Outputs

ª Speaker-Level Inputs , Master Power Switch / AC Power Cord

¡ Subwoofer-Level Control: Volume may be adjusted using the SubwooferLevel Control. Turn the control clockwise to increase the SUB-TS18's volume, or counterclockwise to decrease it. TM High-Cut (Low-Pass) Filter Switch: Placing this switch in the ON position activates circuitry that cuts out all audio input signals above 120Hz, allowing the SUB-TS18 to focus its power on reproducing the lowfrequency portion of the signal, avoiding

inefficiency and distortion. Engage this filter when using the Speaker-Level Inputs ª, or when using the Line-Level Full-Range Inputs ¶, unless your receiver or processor processes its line-level output using a lowpass filter. The filter has no effect when the SUB Input § is used. £ External Trigger Input: Use the supplied mini-plug cable to connect the trigger output of another product to this jack. When a trigger signal between 3 and 30 volts (AC

or DC) is detected, the SUB-TS18 amplifier will turn on, even when the audio-sense feature has been activated by placing the Audio-Sense On/Off Switch ¢ in the AUTO position. The amplifier will remain on for about 10­15 minutes without a trigger signal. ¢ Audio-Sense On/Off Switch: When placed in the AUTO position, and when the Master Power Switch , is turned on, the SUB-TS18 will automatically turn itself on or

5

SUB-TS18

harman/kardon

SUB-TS18 SUBWOOFER AMPLIFIER PANEL CONTROLS AND CONNECTIONS
place itself in the Standby mode, depending on whether it is receiving an audio signal. When this switch is placed in the ON position, the SUB-TS18 will remain on, whether or not it is receiving an audio signal. An LED located on top of the SUB-TS18 indicates whether the SUB-TS18 is in the On or Standby state when used with the AudioSense On/Off Switch ¢ in the AUTO position. The LED is lit blue to indicate that the SUB-TS18 is receiving an audio signal and is turned on, and the LED is lit amber to indicate that no signal is being received and the SUB-TS18 is in the Standby mode. When the Audio-Sense On/Off Switch ¢ is in the ON position, the LED will be lit blue, whether or not an audio signal is present. When the Master Power Switch , is turned off, the LED goes dark, no matter which position the Audio-Sense On/Off Switch ¢ is in. Phase Switch: This switch determines whether the SUB-TS18 subwoofer's pistonlike action moves in and out in phase with the main speakers. If the speakers were to play out of phase, the sound waves produced by the subwoofer would be canceled out, reducing bass response. This phenomenon depends in part on the relative placement of the speakers in the room. In most cases, the Phase Switch should be left in the NORMAL position. However, it does no harm to experiment with the Phase Switch , and you may leave it in the position that maximizes bass response. § Line-Level Subwoofer (SUB) Input: Connect the subwoofer output of a receiver with digital surround sound decoding, such as Dolby® Digital or DTS® to this input. This , input bypasses the SUB-TS18's internal crossover circuitry, and should only be used with a filtered signal. If your receiver does not have digital decoding, you should use the Line-Level Full-Range Inputs ¶ instead. ¶ Line-Level Full-Range Inputs: Connect the line-level subwoofer output or preamp output(s) of your receiver or amplifier to these inputs. If your receiver does not have a separate subwoofer output, use a Y-adapter (not supplied) to bridge the receiver's preamp output to the main amp input for that channel, and connect the long end of the adapter to the corresponding line-level input on the SUB-TS18. If your receiver has only a single subwoofer output, you may connect it to either the left or right line-level input on the SUB-TS 18, and no Y-adapter is needed. · Speaker-Level Outputs: If you are using the Speaker-Level Inputs ª on the SUB-TS18, you should connect these bindingpost terminals to your front left and right speakers, remembering to maintain polarity by connecting the (+) terminal on the SUB-TS18 subwoofer to the (+) terminal on the speaker, and the (­) terminal on the SUB-TS18 subwoofer to the (­) terminal on the speaker. If you are not using the Speaker-Level Inputs ª, then connect your front left and right speakers directly to your receiver or amplifier. See pages 9 through 12 for further information on speaker connections. ª Speaker-Level Inputs: If your receiver or amplifier does not have a line-level subwoofer output, connect these binding-post terminals to the main left and right speaker terminals of your receiver or amplifier. Remember to maintain polarity by connecting the (+) terminal on the receiver/amplifier to the (+) terminal on the SUB-TS18 subwoofer, and the (­) terminal on the receiver/amplifier to the (­) terminal on the SUB-TS18 subwoofer. , Master Power Switch: Place this switch in the "·" position to power-on the SUB-TS18 subwoofer. The SUB-TS18 will then be either in the Standby mode or completely on, depending on the position of the Audio-Sense On/Off Switch ¢. / AC Power Cord: Make sure to plug this cord into an active, unswitched electrical outlet for proper operation of the SUB-TS18. The cord should not be plugged into the accessory outlets found on some audio components.

6

SUB-TS18

harman/kardon

SPEAKER CONNECTIONS
Dolby® Digital or DTS® (or Other Digital Surround Mode) Connection
USE THIS INSTALLATION METHOD FOR DOLBY DIGITAL, DTS OR OTHER DIGITAL SURROUND PROCESSORS: Use the line-level input jack marked SUB § for the low-frequency effects channel. Connect this jack to the subwoofer output or LFE output on your receiver or amplifier. Connect each speaker to the corresponding speaker terminals on your receiver or amplifier. Make sure you've configured your surround sound processor for "Subwoofer On. The " front left, front right, center and surround speakers should all be set to "Small. " When all connections have been made, plug the AC power cord on the subwoofer into an AC outlet.
Front Left SUB/LFE Out Surround Left Center Surround Right

Front Left ­ +

Center ­ +

Front Right ­ +

SUB-TS18 Subwoofer
LINE LEVEL IN SUB R L

Front Right

Surround Left ­ +

Receiver

Surround Right ­ +

7

SUB-TS18

harman/kardon

SPEAKER CONNECTIONS
Dolby Pro Logic® (Non-Digital) ­ Line Level
USE THIS INSTALLATION METHOD FOR DOLBY PRO LOGIC APPLICATIONS (NOT DOLBY DIGITAL, DTS OR OTHER DIGITAL PROCESSING), WHERE THE RECEIVER/ PROCESSOR IS EQUIPPED WITH A SUBWOOFER OUTPUT, OR A VOLUMECONTROLLED PREAMP (LINE-) LEVEL OUTPUT: Use the supplied RCA-type interconnect cable to connect the line-level subwoofer output on your receiver or amplifier to either the left or right Line-Level Full-Range Input ¶ on the SUB-TS18 subwoofer. Use both the left and right inputs on the subwoofer if your receiver or processor has both left and right line-level outputs. In that case, you will need to supply a second interconnect cable. If your receiver is equipped with line-level outputs but does not have a separate subwoofer output, use a Y-adapter (not supplied) to bridge the receiver's preamp output to the main amp input for that channel, and connect the long end of the adapter to the corresponding line-level input on the SUB-TS18. IMPORTANT: Do not use the SUB Input § on the subwoofer with Dolby Pro Logic processors. If your receiver/processor has a built-in lowpass-crossover filter for the subwoofer output, you may use the SUB Input § to bypass the subwoofer's internal crossover. Connect each speaker to the corresponding speaker terminals on your receiver or amplifier. Make sure that you have configured your surround sound processor for "Subwoofer On. The front left, front right, center and " surround speakers should all be set to "Small. " When all connections have been made, plug the AC power cord on the subwoofer into an AC outlet.

Front Left ­ +

Center ­

+

Front Right ­ +

SUB-TS18 Subwoofer Line-Level R L

Front Left SUB/LFE Out Surround Left Center

Front Right

Surround Right

Surround Left ­ +

Receiver

Surround Right ­ +

8 SPEAKER CONNECTIONS 11

SUB-TS18

harman/kardon

SPEAKER CONNECTIONS
Dolby Pro Logic (Non-Digital) ­ Speaker Level
USE THIS INSTALLATION METHOD FOR DOLBY PRO LOGIC APPLICATIONS (NOT DOLBY DIGITAL, DTS OR OTHER DIGITAL PROCESSING), WHERE THE RECEIVER/ PROCESSOR DOES NOT HAVE A SUBWOOFER OUTPUT, OR A VOLUMECONTROLLED PREAMP (LINE-) LEVEL OUTPUT: Connect your receiver or amplifier's front left and right speaker terminals to the left and right Speaker-Level Input ª terminals on the SUB-TS18 subwoofer that are marked "High Level In." Connect the left and right Speaker-Level Output · terminals on the SUB-TS18 subwoofer that are marked "High Level Out" to the corresponding terminals on the back of your front left and right speakers. Connect your receiver or amplifier's center and surround left and right speaker terminals to the corresponding terminals on the back of your center and surround left and right speakers. When all connections have been made, plug the AC power cord on the subwoofer into an AC outlet.

­

Front Left

+

­

Center

+

­

Front Right

+

SUB-TS18 Subwoofer

H I G H L E V E L

L

R

Receiver
Front Left Center Front Right

Surround Left

Surround Right

Surround Left

­

+

Surround Right

­

+

9

SUB-TS18

harman/kardon

OPERATION
Move the Master Power Switch , (marked Power) to the "·" (On) position. The SUB-TS18 subwoofer will automatically turn itself on or go into Standby mode, depending on whether or not a signal is being sent to it by your receiver or surround processor, and provided that the AudioSense On/Off Switch ¢ is moved down so that it is in the AUTO position. When your receiver or amplifier is off, or is not sending program material to the subwoofer, the subwoofer will be in Standby mode and the LED indicator on the top of the subwoofer will turn amber. When the subwoofer senses an audio signal, it will automatically turn itself on and the LED indicator will turn blue. If the subwoofer does not sense a signal after approximately 20 minutes, it will automatically go into Standby mode. When the Audio-Sense On/Off Switch ¢ is switched to the ON position, the subwoofer will remain on, whether or not program material is playing, and the LED indicator will remain lit blue. If your receiver, processor or amplifier is equipped with a compatible trigger output, you may connect it to the SUB-TS18's External Trigger Input £. When you turn on your component, if you have set it up correctly, it will send an electrical trigger signal to the SUB-TS18, which will cause the subwoofer to turn itself on, even when the Audio-Sense On/Off Switch ¢ has been placed in the AUTO position and no audio signal is detected. The trigger signal must be between 3 and 30 volts, although it may be an AC or DC signal, and an AC signal may be 50Hz or 60Hz. If you'll be away from home for an extended period of time, or if the subwoofer will not be used, switch the Master Power Switch , to the OFF position. Volume Volume can be adjusted using the Subwoofer-Level Control ¡, as shown. Turn the control knob clockwise to increase the volume of the subwoofer, and counterclockwise to decrease the subwoofer's volume.
Subwoofer Level

Additional Bass Adjustments In addition to the volume adjustments described previously, the SUB-TS18 subwoofer includes a Phase Switch and a Filter Switch TM that can be used to adjust the bass response to suit your listening environment or taste. In most situations, the Phase Switch should be left in the NORMAL position. If you suspect that the subwoofer is playing out of phase with the other speakers, which would tend to diminish bass response, try placing this switch in the REVERSE position. There is no harm in experimenting, and you may return the switch to the NORMAL position at any time. If you rearrange your room and reposition the speakers, it would be a good idea to check whether they are in phase by flipping this switch. The High-Cut (Low-Pass) Filter Switch TM limits the frequencies of the audio signal inputted to the subwoofer to the low frequencies that the subwoofer reproduces best. This allows the subwoofer to perform more efficiently, and with superior bass reproduction, minimizing distortion that might occur if the subwoofer attempted to reproduce higher frequencies. This switch should be left in the ON position, except: 1. When the SUB Input § is being used, in which case it has no effect, or 2. When the Speaker-Level Inputs ª or the Line-Level Full-Range Inputs ¶ are being used with a crossover or filter aboard the receiver or processor. In these two circumstances, place the switch in the OFF position.

MIN

MAX

Subwoofer Level

MIN

MAX

10

SUB-TS18

harman/kardon

Test Set Up and Procedure

Equipment needed: · Function/signal generator/sweep generator · Integrated Amplifier · Multimeter · Speaker cables Initial Control Settings: · Power Switch OFF; Filter OFF · Level MIN (Full CCW) · Phase, Auto/On switches do not matter General Unit Function (UUT = Unit Under Test) 1) From the signal generator, connect one line level (RCA) cable to the Subwoofer Line Level Input jacks L/R on the UUT. Use a Y-cable from a mono source if necessary to connect to both inputs. Do not connect to the single, purple SUB input. 2) Turn on generator; adjust to 60mV, 50 Hz. 3) Plug in UUT; turn the power switch ON. Turn LEVEL control full clockwise (MAX) 4) LED should turn from Amber to Blue (on top of UUT); immediate and vigorous bass response should be heard and felt from port tube opening. 5) Turn off generator, turn LEVEL control full counterclockwise (MIN), and disconnect RCA cable. 6) Connect one pair of speaker cables to Speaker Level input terminal (IN) on UUT. Cables should be connected to an integrated amplifier fed by the signal generator. 7) Turn on generator and adjust so that speaker level input at the amplifier is 1.2V, 50 Hz. Turn LEVEL control full clockwise. 8) LED should turn from Amber to Blue; immediate and vigorous bass response should be heard and felt from the port tube opening. Sweep Function 1) Follow steps 6-8 above, using a sweep generator as a signal source. 2) Sweep generator from 20Hz to 300Hz. Listen to the cabinet and drivers for any rattles, clicks, buzzes or any other noises. If any unusual noises are heard, remove woofers and test. Driver Function 1) Remove woofer from cabinet; detach + and - wire clips. 2) Check DC resistance of woofer; it should be 2.8 ohms ±10% 3) Connect a pair of speaker cables to driver terminals. Cables should be connected to an integrated amplifier fed by a signal generator. Turn on generator and adjust so that speaker level output is 5.0V. 4) Sweep generator from 20Hz to 1kHz. Listen to driver for any rubbing, buzzing, or other unusual noises.
11

SUB-TS18

harman/kardon

12

SUB-TS18

harman/kardon

13

SUB-TS18

harman/kardon

14

SUB-TS18

harman/kardon

SUB-TS18 (UL) AMP Troubleshooting Flow Chart

AMP no signal out no yes Dc voltage check ±Vcc yes Check+/-15VDC yes LED light green or red LED light green Check U202 pin8 signal
yes yes

Check Fuse,Transformer, D501, etc yes

no Check Q501.Q502.Q503,D502 etc yes LED red
yes

Check,Q206,Q207,U203 etc
yes

no

Check U201 pin1 signal
no

CheckU201,U202,VR201 etc

no Check limiter Circuit C317
Check U301,R343,R344 , C340,Q301,Q302, etc

yes Test R147 signal yes

yes Check ,+VCC& -VCC no DC voltage yes Check CLASS 150W MODEL no

Check RY101,D110,Q112,Q113 etc yes Check Q107,Q108,Q109 etc yes yes Check M100 signal

Check TH1

The Amp ass'Y OK, END

15

SUB-TS18

harman/kardon

16

SUB-TS18

harman/kardon

17

SUB-TS18

harman/kardon

18

SUB-TS18

harman/kardon

19

SUB-TS18

harman/kardon

SUB-TS18 120V Electrical parts list
Part number Description Qty Reference Designator

PREAMP PCB
Resistors 110-12472j52-e 110-16102j26-e 110-16103j26-e 110-16104j26-e 110-16105j26-e 110-16113j26-e 110-16122j26-e 110-16134j26-e 110-16152j26-e 110-16183j26-e 110-16203j26-e 110-16223j26-e 110-16303j26-e 110-16472j26-e 110-16473j26-e 110-16474j26-e 110-16475j26-e 110-16512j26-e 110-16622j26-e 110-16684j26-e 110-16912j26-e 110-16913j26-e 116-169091f26-e 115-h503a102-e 116-201001j5vx-e Capacitors 129-a154j633-e 129-a224j633-e 130-2b103k503-e 130-2b221k503-e 130-3f104z503-e 132-183j503-e 132-223ja03-e 132-473j503-e 132-563j503-e 132-823j503-e 135-3105m50-e 135-3106m50-e 135-3107m16-e 135-3226m50-e 135-3475m16-e 135-3107m50-e 135-3227m50-e Semiconductors 192-027c1815gr-e 197-631n4148-e 199-65000513g-e 190-06m4558d-e 190-06m4558ld-e 190-16tl074cn-e 197-141n4004-e 190-05ps25051-e TRANSISTOR 2SC1815GR NPN TOSHIBA(RoHS) DIODE 500mW 75V 1N4148 Panjit (RoHS) ZENER DIODE GDZJ5.1B 500mW 5.1V 2% ROHM 1N5231B I.C. OPA 4558D dual OP-AMP inline (RoHS) I.C. NJRC NJM4558LD OP-AMP inglerow inline (RoHS) I.C TL074CN ST QUAD OP-AMP *DIODE 1N4004 shaping short crus (RoHS) photoelectric coupler PS2505-1 NEC (RoHS) 4 13 1 1 1 2 4 1 Q201,Q206,Q207,Q208 D201,D202,D203,D204,D205,D206,D207,D208,D214,D 215,D216,D301,D302 D213 U203 U204 U201,U202 D217,D218,D219,D220 U1 METALIZE CAP. 0.15U 63V ±5% MSC (RoHS) METALIZE CAP. 0.22uF 63V ±5% MSC (RoHS) DISC CAPACITOR 0.01u 50V ±10% (RoHS) DISC CAPACITOR 220P 50V ±10% (RoHS) DISC CAPACITOR 0.1U 50V +80/-20% (RoHS) MYLAR CAPACITOR 0.018uF 50V ±5% (RoHS) MYLAR CAPACITOR 0.022uF 100V ±5% (RoHS) MYLAR CAPACITOR 0.047U 50V ±5% (RoHS) MYLAR CAPACITOR 0.056U 50V ±5% (RoHS) MYLAR CAPACITOR 0.082U 50V ±5% (RoHS) ELECTROLYTIC CAP. 1U 50V ±20% (RoHS) ELECTROLYTIC CAP. 10uF 50V ±20% (RoHS) ELECTROLYTIC ELECTROLYTIC ELECTROLYTIC ELECTROLYTIC ELECTROLYTIC CAP. 100uF 16V ±20% (RoHS) CAP. 22U 50V ±20% (RoHS) CAP.4.7U 16V ±20% (RoHS) CAP. 100U 50V ±20% (RoHS) CAP. 220uF 50V ±20% (RoHS) 2 1 1 12 8 1 1 1 1 1 1 12 1 1 1 1 1 C221,C222 C218 C238 C200,C204,C205,C207,C208,C210,C211,C212,C214,C 220,C230,C237 C232,C242,C244,C245,C246,C252,C254,C256 C223 C215 C224 C216 C217 C228 C201,C202,C206,C213,C219,C231,C241,C243,C251,C 253,C248,C247 C234 C225 C233 C301 C300 RESISTOR4.7K 1/2W ±5% CF 52mm (RoHS) RESISTOR 1K 1/6W ±5% CF 26mm (RoHS) RESISTOR 10K 1/6W ±5% CF 26mm (RoHS) RESISTOR 100K 1/6W ±5% CF 26mm (RoHS) RESISTOR 1M 1/6W ±5% CF 26mm (RoHS) RESISTOR 11K 1/6W ±5% 26mm (RoHS) RESISTOR 1.2K 1/6W ±5% CF 26mm (RoHS) RESISTOR 130K 1/6W ±5% CF 26mm (RoHS) RESISTOR 1.5K 1/6W ±5% CF 26mm (RoHS) RESISTOR 18K 1/6W ±5% CF 26mm (RoHS) RESISTOR 20K 1/6W ±5% CF 26mm (RoHS) RESISTOR 22K 1/6W ±5% CF 26mm (RoHS) RESISTOR 30K 1/6W ±5% CF 26mm (RoHS) RESISTOR 4.7K 1/6W ±5% CF 26mm (RoHS) RESISTOR 47K 1/6W ±5% CF 26mm (RoHS) RESISTOR 470K 1/6W ±5% CF 26mm (RoHS) RESISTOR 4.7M 1/6W ±5% CF 26mm (RoHS) RESISTOR 5.1K 1/6W ±5% CF 26mm (RoHS) RESISTOR 6.2K 1/6W ±5% CF 26mm (RoHS) RESISTOR 680K 1/6W CF 26mm (RoHS) RESISTOR 9.1K 1/6W ±5% CF 26mm (RoHS) RESISTOR 91K 1/6W ±5% CF 26mm (RoHS) RESISTOR 9.09K 1/6W±1% MF 26mm (RoHS) variable RESISTOR RV16AE-20B2-15K-A54-104(A50K) (RoHS) metal oxide film RESISTOR 1K 2W ±5% 5mm (RoHS) 2 6 18 5 1 1 1 1 1 1 2 6 2 3 2 1 1 2 1 1 2 4 1 1 1 R201,R202 R213,R214,R215,R254,R253,R304 R209,R212,R216,R217,R218,R220,R221,R222,R225,R 228,R229,R230,R232,R235,R240,R248,R260,R270 R231,R263,R266,R257,R300 R259 R268 R265 R233 R302 R262 R237,R238 R247,R255,R256,R249,R250,R261 R223,R224 R200,R207,R258 R219,R264 R251 R303 R210,R211 R234 R252 R226,R227 R203,R204,R205,R206 R301 VR201 R267

20

SUB-TS18
Part number Description Qty Reference Designator

harman/kardon

PREAMP PCB
Miscellaneous 162-50122004-e 162-5014d008-e 162-a016d001-e 174-0rca313v-e 174-20810360g-e 174-6ej3556agp-e 175-1b08v01-e 175-1c07v01-e 180-tms7210v-e 362-FE-00041-0LAE drop-out line 120mm RED/WHT 2PIN (RoHS) WIRE 2468#26AWG RED/WHT length 140mm (RoHS) mixed wire UL1007 160/80mm#26 (RoHS) RCA JACK RCA-313G V/R/W (RoHS) jack SPK JK BP 8PIN (RoHS) SH0810360G US1.35 PHONE JACK EJ3556A-GP (RoHS) WIRE CONNECTOR & BASE 8 PIN PITCH=2.0mm(RoHS) WIRE CONNECTOR & BASE 7PIN PITCH=2.5mm (RoHS) SWITCH SLIDE 6PIN MS7210V (RoHS) PCB support 11.75*8.5*12.5H (RoHS) 1 1 1 1 1 1 1 1 3 2 D209 P1-P2 W202 JK201 JK202 JK203 W202 M201 SW201,SW202,SW203

MAIN PCB
Resistors 110-14103j26-e 110-14222j26-e 110-14432j26-e 110-14472j26-e 110-16102j26-e 110-16103j26-e 110-16104j26-e 110-16153j26-e 110-16182j26-e 110-16203j26-e 110-16221j26-e 110-16222j26-e 110-16223j26-e 110-16333j26-e 110-16393j26-e 110-16434j26-e 110-16473j26-e 110-16474j26-e 110-16562j26-e 110-16621j26-e 110-16751j26-e 110-16755j26-e 116-161002f26-e 116-161202f26-e 116-162200f26-e 116-162202f26-e 110-20332jk3-e 113-50s68j00-e 116-201001jk3x-e 116-304700jk2x-e Capacitors 130-3f104z503-e 130-sl101k503-e 132-103j503-e 132-103ja03-e 132-104ja03-e 132-273ja03-e 135-3106m50-e 135-3107m10-e 135-3107m35-e 135-3225m50-e 135-3226m16-e 135-3226m50-e 135-3227m16-e 135-3476m16-e DISC CAPACITOR 0.1U 50V +80/-20% (RoHS) DISC CAPACITOR 100P 50V SL ±10% (RoHS) MYLAR CAPACITOR 0.01uF 50V ±5% (RoHS) MYLAR CAPACITOR 0.01uf 100V ±5% (RoHS) MYLAR CAPACITOR 0.1UF 100V ±5% (RoHS) MYLAR CAPACITOR 0.027UF 100V ±5% (RoHS) ELECTROLYTIC CAP. 10uF 50V ±20% (RoHS) ELECTROLYTIC CAP. 100U 10V ±20% (RoHS) ELECTROLYTIC CAP. 100U 35V ±20% (RoHS) ELECTROLYTIC CAP. 2.2U 50V ±20% (RoHS) ELECTROLYTIC CAP. 22U 16V ±20% (RoHS) ELECTROLYTIC CAP. 22U 50V ±20% (RoHS) ELECTROLYTIC CAP. 220U 16V ±20% (RoHS) ELECTROLYTIC CAP. 47U 16V ±20% (RoHS) 6 3 2 2 3 1 2 2 2 1 1 2 1 1 C107,C117,C122,C144,C320,C322 C302,C303,C306 C305,C317 C103,C104 C123,C503,C504 C143 C319,C321 C114,C115 C507,C508 C509 C304 C505,C506 C118 C318 RESISTOR 10K 1/4W ±5% CF 26mm (RoHS) RESISTOR 2.2K 1/4W ±5% CF 26mm (RoHS) RESISTOR 4.3K 1/4W ±5% CF 26mm (RoHS) RESISTOR 4.7K 1/4W ±5% CF 26mm (RoHS) RESISTOR 1K 1/6W ±5% CF 26mm (RoHS) RESISTOR 10K 1/6W ±5% CF 26mm (RoHS) RESISTOR 100K 1/6W ±5% CF 26mm (RoHS) RESISTOR 15K 1/6W ±5% CF 26mm (RoHS) RESISTOR 1.8K 1/6W ±5% CF 26mm (RoHS) RESISTOR 20K 1/6W ±5% CF 26mm (RoHS) RESISTOR 220 1/6W ±5% CF 26mm (RoHS) RESISTOR 2.2K 1/6W ±5% CF 26mm (RoHS) RESISTOR 22K 1/6W ±5% CF 26mm (RoHS) RESISTOR 33K 1/6W ±5% CF 26mm (RoHS) RESISTOR 39K 1/6W ±5% CF 26mm (RoHS) RESISTOR 430K 1/6W ±5% CF 26mm (RoHS) RESISTOR 47K 1/6W ±5% CF 26mm (RoHS) RESISTOR 470K 1/6W ±5% CF 26mm (RoHS) RESISTOR 5.6K 1/6W ±5% CF 26mm (RoHS) RESISTOR 620 1/6W ±5% CF 26mm (RoHS) RESISTOR 750 1/6W ±5% CF 26mm (RoHS) RESISTOR 7.5M 1/6W ±5% CF 26mm (RoHS) metal film RESISTOR 10K 1/6W ±1% MF 26mm (RoHS) metal film RESISTOR 12.0K 1/6W ±1% MF 26mm (RoHS) metal film RESISTOR 220 1/6W ±1% MF 26mm (RoHS) metal film RESISTOR 22.0K 1/6W ±1% MF 26mm (RoHS) RESISTOR 3.3K 2W ±5% standing short crus 7.5m (RoHS) cement RESISTOR 0.068 5W ±5% prone long crus (RoHS) oxide film RESISTOR 1.00K 2W ±5% 7.5mm (RoHS) oxide film RESISTOR 470 3W ±5% 10mm (RoHS) 3 1 1 1 1 10 3 1 1 1 1 1 1 1 1 1 2 1 1 1 1 1 2 1 1 1 1 1 1 2 R503,R504,R510 R511 R506 R505 R153 R128,R130,R149,R150,R305,R306,R308,R311,R314,R 319 R122,R126,R307 R107 R145 R309 R144 R102 R316 R310 R151 R312 R106,R129 R127 R152 R160 R315 R313 R301,R303 R302 R317 R318 R134 R147 R148 R501,R502

21

SUB-TS18
Part number Description Qty Reference Designator

harman/kardon

MAIN PCB
138-5478m80-e 132-103kd00-e Semiconductors 192-027c1815gr-e 192-027c2235y-e 192-028a1015gr-e 192-1572n5551-e 192-1582n5401-e 197-631n4148-e 199-65000623g-e 199-65001603g-e 190-16tl074cn-e 192-161tip31c-e 192-162tip32c-e 197-00kbu606g-e 197-141n4004-e Miscellaneous 109-1ttc802j0-e 120-1000003-e 162-50129001-e 171-urwh124d-e 175-1d02v01-e 175-1d03v01-e thermistor TTC-802(JS) NTC long crus (RoHS) inductor 10W AI YT-C3104-005 1CRHW 354708LTB (RoHS) CABLE ASS'Y drop-out line 120mm AWG28 WHT (RoHS) relay RWH-SH-124D (1600 ohm) (RoHS) WIRE CONNECTOR & BASE 2PIN PITCH=3.96mm (RoHS) WIRE CONNECTOR & BASE 3 PIN PITCH=3.96mm JST-VH take off the middle PIN 1 2 1 1 1 1 TH1 FB1,FB2 W201 RL1 M100 M500 TRANSISTOR 2SC1815GR NPN TOSHIBA(RoHS) TRANSISTOR 2SC2235Y NPN TOSHIBA (RoHS) TRANSISTOR 2SA1015GR PNP TOSHIBA(RoHS) *TRANSISTOR FSC 2N5551 NPN (RoHS) TRANSISTOR FSC 2N5401 AI-PNP 350V 500mA TO-92 (RoHS) DIODE 500mW 75V 1N4148 Panjit (RoHS) ZENER DIODE GDZJ6.2B 500mW 6.2V 26mm 2% (RoHS) ZENER DIODE GDZJ16C 500mW 16V 26mm 2% (RoHS) I.C TL074CN ST QUAD OP-AMP TRANSISTOR TIP31C NPN SGS (RoHS) TRANSISTOR TIP32C PNP SGS (RoHS) bridge rectifier 6A 800V KBU606G (RoHS) *DIODE 1N4004 shaping short crus (RoHS) 5 1 3 2 1 7 1 1 1 1 1 1 2 Q108,Q109,Q113,Q301,Q302 Q111 Q101,Q107,Q112 Q114,Q115 Q503 D102,D103,D104,D105,D143,D301,D302 D101 D502 U301 Q501 Q502 D501 D110,D504 LARGE ELECTROLYTIC CAP. 4700uF 80V ±20% 85 MYLAR CAPACITOR 0.01U 400V +/-10% long crus (RoHS) 2 1 C501,C502 C500

CLASS D ASS'Y PCB (Replacment of entire module is recommended, part# 051-B00012A-E).
Resistors 118-12061001j-e 118-12061002j-e 118-120610r0j-e 118-12061201j-e 118-12062002j-e 118-12062201j-e 118-12062701j-e 118-12063000j-e 118-12063301j-e 118-12063902j-e 118-12064700j-e 118-12064701j-e 118-12064702j-e 118-12064704j-e 118-120647r0j-e Capacitors 141-c0101k50-e 141-c0220k50-e 141-c0561k50-e 141-c5104m50-e 141-c7223k50-e 141-d7104ka0-e 141-d7104kb5-e Semiconductors 190-16tl072dts-e 192-09124126qs-e *SMD I.C. TL072CDT Dual Op-Amp SGS THOMSON (RoHS) SMD TRANSISTOR 2SC2412K-T146Q/R ROHM (RoHS) 1 3 IC1 Q1,Q4,Q5 SMD CAPACITOR 100pF 50V 10% 1206 NP0 (RoHS) SMD CAPACITOR 22pF 50V 10% 1206 SMT NPO (RoHS) SMD CAPACITOR 560pF 50V 10% 1206 NPO (RoHS) SMD CAPACITOR 1206 Y5V 0.1uF 50V ±20% (RoHS) SMD CAPACITOR 0.022uF 50V 10% 1206 X7R (RoHS) SMD CAPACITOR 0.1uF 100V 10% 1210 X7R (RoHS) SMD CAPACITOR 0.1uF 250V 10% 1210 X7R (RoHS) 1 1 1 8 1 1 5 C4 C5 C6 C2,C3,C7,C8,C9,C10,C11,C15 C13 C12 C1,C18,C19,C20,C14 SMD RESISTOR 1.00K 1206 5% (RoHS) SMD RESISTOR 10.0K 1206 5% (RoHS) SMD RESISTOR 10.0 1206 5% (RoHS) SMD RESISTOR 1.20K 1206 5% (RoHS) SMD RESISTOR 20.0K 1206 5% (RoHS) SMD RESISTOR 2.20K 1206 5% (RoHS) SMD RESISTOR 2.70K 1206 5% (RoHS) SMD RESISTOR 300.0 1206 5% (RoHS) SMD RESISTOR 3.30K 1206 5% (RoHS) SMD RESISTOR 39.0K 1206 5% (RoHS) SMD RESISTOR 470 1206 5% (RoHS) SMD RESISTOR 4.70K 1206 5% (RoHS) SMD RESISTOR 47.0K 1206 5% (RoHS) SMD RESISTOR 4.70M 1206 5% (RoHS) SMD RESISTOR 47.0 1206 5% (RoHS) 4 3 2 16 1 3 1 1 4 1 1 3 1 1 2 R2,R11,R29,R30 R7,R9,R25 R22,R23 R31,R32,R33,R34,R35,R36,R37,R38,R39,R40,R41, R42,R43,R44,R45,R46 R26 R6,R13,R16 R10 R24 R14,R15,R27,R28 R3 R8 R1,R5,R12 R17 R4 R20,R21

22

SUB-TS18
Part number Description Qty Reference Designator

harman/kardon

CLASS D ASS'Y PCB
192-09139066rs-e 192-09210376qs-e 192-09215146rs-e 197-03rls4148s-e 199-15000563s-e 199-1500120s-e 199-15001503s-e 192-233f640n-e 192-232irf9640-e Miscellaneous 122-14350j4180-e 128-e106ma01k-e 175-9f40hr2-e 122-14121m4191-e choke coil 35uH Ferrite Core 25 Milliohm (RoHS) non polarized ELEC LYTIC CAP. 10UF 100V 20% 105 (RoHS) WIRE CONNECTOR & BASE 40PIN PITCH=2.54mm HR2*40 (RoHS) Ferrite core word type LS-A6206-ST EFD-30 (RoHS) 1 2 L2 C16,C17 SMD TRANSISTOR 2SC3906K-T146R ROHM (RoHS) SMD TRANSISTOR 2SA1037K-T146Q/R ROHM (RoHS) SMD TRANSISTOR 2SA1514K-T146R ROHM (RoHS) *SMD DIODE RLS4148-TE11 ROHM (RoHS) SMD ZENER 5.6V 5% PHILIPS BZX84-C5V6 (RoHS) SMD ZENER 12V 5% PHILIPS BZX84-C12 (RoHS) SMD ZENER 15V 5% PHILIPS BZX84-C15 (RoHS) TRANSISTOR IRF640N INTERNATIONAL (RoHS) FET IRF9640 IR P-CH TO220 (RoHS) 2 2 2 6 2 2 2 1 1 Q2,Q8 Q7,Q9 Q3,Q6 D1,D2,D3,D4,D5,D6 Z1,Z2 Z5,Z6 Z3,Z4 Q11 Q10

1

L1

MISCELLANEOUS/MECHANICAL
150-r4055903-e 152-u602015-e 154-k31505t0-e 155-63032i-e 162-10152001-e 162-5020d006-e 162-50552003-e 176-wjce1-e 180-prf1003s-e 193-201815t2-e 302-AL-00373-1BGE 306-ABS-00714-0BAE 311-ABS-00028-0BAE 317-000-00037-0LAE 323-AL-00056-0LAE 333-EVA-00096-0BAE 333-EVA-00097-0BAE 333-EVA-00121-0BAE 333-EVA-00132-0BAE 333-EVA-00133-0BAE 333-EVA-00188-0BAE 333-EVA-00219-0BAE 333-EVA-00220-0BAE 333-EVA-00866-0BAE 335-NYL-00002-0BAE 335-NYL-05015-0BAE 350-EM04012D024-E 351-AM03008A078-E 351-AM03008A079-E 352-AM03008D040-E 352-AM03008D041-E 352-AM03010D065-E 352-HM03012D086-E 353-0870122-E 362-FE-00013-0LAE Power transformer TT0900304490 (RoHS) power cord joint heteropolarity SVT FT-26FT bi-insul (RoHS) fuse 3.15A 250V 30mm UL/CSA/PSE (RoHS) fuse holder HTB-32I 30mm UL/CSA (RoHS) WIRE UL1617 AWG22 150mm RED 6:6 (RoHS) WIRE UL2468 200mm 2.5mmpitch RED/WHT (RoHS) WIRE UL1007 #16 550mm (RoHS) #110/#205 0.5T dead end CE-1 (RoHS) power switch ROCK RF-1003-BB2-OHA(RoHS) ceramic insulator (RoHS) aluminium rear board 270*215*2.5T anode black (RoHS) plastic rear housing 268*213*102 spout conductive paint (RoHS) plastic KNOB 46077-W soft material P.V.C.(RoHS) LEVEL earth terminal M3 lug plate t=0.3 (RoHS) heat sink 83.5*50.5*27.5H defat Gasket pad wide sides 213*15*2.0mm (RoHS) Gasket pad wide sides 213*15*1.0t (RoHS) 8PIN BB Gasket (RoHS) Gasket pad long sides 238*15*2.0mm (RoHS) Gasket pad long sides 238*15*1.0t (RoHS) Gasket pad 170x5x1t glue on back (RoHS) Gasket pad wide sides 150*15*1t UL (RoHS) Gasket pad long sides 225*15*1t UL (RoHS) Gasket 48*18*1.5T (RoHS) WIRE CLIP 4K-4 NO-BB(RoHS) power cord fixed button SB4F-2 (RoHS) 4*12 wood screw electrical back (RoHS) M3*8 machine screw nickel plating (RoHS) M3*8 machine screw electrical back (RoHS) 3*8 type ping screw electrical back (RoHS) 3*8 type ping screw nickel plating (RoHS) 3*10 P type ping electrical back (RoHS) 3*12 type ping screw electrical back (RoHS) machine screw M8*70 round head electrical back (RoHS) PCB support L TYPE t=1.6mm S.P.C.C 89*9*1.6T (RoHS) 1 1 1 1 1 1 1 1 1 2 1 1 1 1 1 2 2 1 2 2 1 2 1 1 1 1 4 4 4 2 2 3 1 1 2 T501

F501

SW501 for Q10,Q11

23

SUB-TS18

harman/kardon

24

SUB-TS18

harman/kardon

25

SUB-TS18

harman/kardon

26

SUB-TS18

harman/kardon

27