Text preview for : 2001RB Switch Board.pdf part of GallienKrueger 2001RB-II 2001RB switch pcb



Back to : 2001RB Switch Board.pdf | Home

6131A.sch-1 - Tue Aug 17 09:38:10 2004

6131A1.sch-1 - Tue Jul 08 15:28:31 2003

6131A2.sch-1 - Mon Oct 14 14:37:03 2002

6131A3.sch-1 - Tue Jul 16 15:59:46 2002

6131A4.sch-1 - Fri Dec 06 18:09:44 2002

gallien technology
Customer Name: Model: Assembly Description: Assembly Numbers:

Engineering Change Order
Current Rev #: Distribute To: Originator: Approved by: Effective Date:

Gallien-Krueger 2001RB 2001RB power switch board 206-0131-A
Effective

A0

New ECO Rev #: Page:

1 Of: Alvin Villaflor 8/19/2002
Date

A04 1

Document Update Next Buy Artwork Assembly Dwg. Next Production Run

Initials

x x

All in Process All in Service

x

All in Stock Beginning Serial Number: Reason For Change

x X

Board Artwork BOM Control Form Costing Fab Drawing Inspection Proc.

RAG RAG

A1-Add RF filter caps c1-9,11,17 & 18. Change R6,7 to 221, & R13 to 22.1. Change F1 to T400mA, F2 to F15A Change J4 to be 3 pin. New primary pin arrangement for creep. A2-Reverse trigger in/out jack positions. A3-Change all axial ceramic to polyester. Change C6 to 100pF radial ceramic to eliminate slight turn on pop. A4-Reroute four primary and secondary traces to meet creep requirements.
Continued on ECO Supplement Page Description Of Change

X X

Part Master File Schematic Service Manual Test Procedure

RAG RAG

Other Affected Assemblies 302-2090-A, 302-0090-A, 302-1090-A
Distribution Accounting Assembly Customer Date Initials

Replace Rev-A BOM completely with Rev-A4 BOM. Revs-A2 & A3 were not released to production so no ECOs were written. X X X X

Engineering Incoming Q.C. Planning Production Eng. Purchasing Q.A. Receiving Service

X

Test Vendor

Continued on ECO Supplement Page Part Number Description Qty Parts Added Ref. Designator

Drawing(s) attached Parts Deleted Qty Ref. Designator

ECO FORM REV-H

6131A ECO, 8/13/2004

6293A.sch-1 - Tue Dec 17 11:34:02 2002

gallien technology
Customer Name: Model: Assembly Description: Assembly Numbers:

Engineering Change Order
Current Rev #: Distribute To: Originator: Approved by: Effective Date: Artwork Assembly Dwg. New ECO Rev #: Page:

Gallien-Krueger 2001RB 2001RB power switch board 206-0293-A 145-0293-A
Effective

1

Of:

A 1

Gallien 8/19/2002
Date Initials

Document Update Next Buy Next Production Run

All in Process All in Service All in Stock Beginning Serial Number:

x x

x X
Reason For Change

Board Artwork BOM Control Form Costing Fab Drawing Inspection Proc.

RAG RAG

Update artwork for larger hole sizes for auto insertion. Change part number to 206-0293-A. X X

Part Master File Schematic Service Manual Test Procedure

RAG RAG

Other Affected Assemblies 302-0290-A, 302-1290-A, 302-2290Continued on ECO Supplement Page Description Of Change Distribution Accounting Assembly Customer Date Initials

X X X X

Engineering Incoming Q.C. Planning Production Eng. Purchasing Q.A. Receiving Service

X

Test Vendor

Continued on ECO Supplement Page Part Number Description Qty Parts Added Ref. Designator

Drawing(s) attached Parts Deleted Qty Ref. Designator

ECO FORM REV-H

6293A ECO, 8/13/2004

6293A1.sch-1 - Fri Apr 04 17:51:40 2003

gallien technology
Customer Name: Model: Assembly Description: Assembly Numbers:

Engineering Change Order
Current Rev #: Distribute To: Originator: Approved by: Effective Date: Artwork Assembly Dwg.

Gallien-Krueger 2001RB 2001RB power switch board 206-0293-A1 145-0293-A1
Effective

A

New ECO Rev #: Page:

1

Of:

A1 1

Gallien 8/19/2002
Date Initials

Document Update Next Buy Next Production Run

All in Process All in Service All in Stock Beginning Serial Number:

x x

x X
Reason For Change

Board Artwork BOM Control Form Costing Fab Drawing Inspection Proc.

RAG RAG

Change F1 notation to 230V to T8AH. Add two holes to cable tie T1 to the board. X X

Part Master File Schematic Service Manual Test Procedure

RAG RAG

Other Affected Assemblies 302-0290-A, 302-1290-A, 302-2290Continued on ECO Supplement Page Description Of Change Distribution Accounting Assembly Customer Date Initials

X X X X

Engineering Incoming Q.C. Planning Production Eng. Purchasing Q.A. Receiving Service

X

Test Vendor

Continued on ECO Supplement Page Part Number Description Qty Parts Added Ref. Designator

Drawing(s) attached Parts Deleted Qty Ref. Designator

100-0036-0

Cable tie 8"

1

ECO FORM REV-H

6293A ECO, 8/13/2004

6293A2.sch-1 - Thu Nov 27 16:25:07 2003

gallien technology
Customer Name: Model: Assembly Description: Assembly Numbers:

Engineering Change Order
Current Rev #: Distribute To: Originator: Approved by: Effective Date: Document Update Date Initials Artwork Assembly Dwg.

Gallien-Krueger 2001RB 2001RB power switch board 206-0293-A 145-0293-A
Effective

A1

New ECO Rev #: Page:

1

Of:

A2 1

Gallien

All in Process All in Service All in Stock Beginning Serial Number:

x

Next Buy Next Production Run

x X
Reason For Change

Board Artwork BOM Control Form Costing Fab Drawing Inspection Proc.

RAG RAG

Add 240V supply table to board and schematic.

X X

Part Master File Schematic Service Manual Test Procedure

RAG RAG

Other Affected Assemblies 302-0290-A, 302-1290-A, 302-2290Continued on ECO Supplement Page Description Of Change Distribution Accounting Assembly Customer Date Initials

X X X X

Engineering Incoming Q.C. Planning Production Eng. Purchasing Q.A. Receiving Service

X

Test Vendor

Continued on ECO Supplement Page Part Number Description Qty Parts Added Ref. Designator

Drawing(s) attached Parts Deleted Qty Ref. Designator

ECO FORM REV-H

6293A ECO, 8/13/2004