PAMS Technical Documentation NSE6 Series Transceivers
Service Tools
Original 08/98
NSE6 Service Tools
PAMS Technical Documentation
CONTENTS Page No
Service Box JBU5 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Product Code . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . View of JBU5 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . PNS5 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Product Code . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Module Jig MJS6 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Product Code . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . View of MJS6 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Battery Adapter BDS6 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Product Code . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . View of BDS6 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Flash Loading Adapter FLA5 (Sales Pack) . . . . . . . . . . . . . . . . . . . . . . Sales package code . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . View of FLA5 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Flash Prommer FPS4S (Sales Pack) . . . . . . . . . . . . . . . . . . . . . . . . . . . Sales package code . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . View of FPS4 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Security Box TDF4 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Product Code . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . View of TDF4 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Service Audio Box JBA4 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Product Code . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . View of JBA4 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Audio Cable ADS1 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Product code . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . View of ADS1 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . D15D15 Cable AXS5 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Product Code . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . View of AXS5 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . DC Charging Cable PCC1 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Product Code . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . View of PCC1 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . DC Cable SCB3 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Product Code . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . View of SCB3 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . MBUS Cable DAU9S . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4 4 4 4 4 5 5 5 6 6 6 7 7 7 8 8 8 9 9 9 10 10 10 11 11 11 12 12 12 13 13 13 14 14 14 15
Page 2
Original 08/98
PAMS Technical Documentation
NSE6 Service Tools 15 15 16 16 16 17 17 17 18 18 18 19 19 19 20 20 20
Product Code . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . View of DAU9S . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Power Cable PCS1 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Product Code . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . View of PCS1 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Audio Cable SCA5 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Product code . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . View of SCA5 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Service Cable XCM5 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Product code . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . View of XCM5 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Modular Tadapter . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Product Code . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . View of Modular Tadapter . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . SW Security Device PKD1 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Product Code . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . View of SW Security Device . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Original 08/98
Page 3
NSE6 Service Tools
PAMS Technical Documentation
Service Box JBU5
The Service Box JBU5 is used for power supply and current calibration. Also flash loading and functional tests. Product Code Service Box JBU5: View of JBU5 0770120
PNS5 "Pin set" PNS5 is a spare part for Service Box JBU5 Product Code Pin set PNS5: 0750122
Page 4
Original 08/98
PAMS Technical Documentation
NSE6 Service Tools
Module Jig MJS6
The Module Jig MJS6 is used for repair of system/RF module. * Product Code Module Jig MJS6: View of MJS6 0770121
*Note:
The nominal supply voltage for MJS6 is +3.6 V. The supply voltage must not exceed +5.0 V.
Original 08/98
Page 5
NSE6 Service Tools
PAMS Technical Documentation
Battery Adapter BDS6
The Battery Adapter BDS6 is used along with an external battery capacity meter to check battery capacity. Note that Liion batteries have an internal protection circuit to prevent deep discharge. Product Code Battery Adapter BDS6: View of BDS6 0750121
Page 6
Original 08/98
PAMS Technical Documentation
NSE6 Service Tools
Flash Loading Adapter FLA5 (Sales Pack)
The Flash Loading Adapter FLA5 is used with the Service Battery BBD3 and Service Cable SCH5. Power is supplied to FLA5 from the Flash Security Box TDF4 via the DC cable PCC1, (The PCC1 cable can be replaced with a Travel Charger ACH6), and is connected to the Flash Prommer FPS4S with the cable AXS5. The sales pack includes: Flash Loader Adapter FLA5 Service cable SCH5 D15 D15 Cable AXS5 Installation software for FPS4 Sales package code Flash Loading Adapter FLA5: View of FLA5 0080178 0770085 0730098 0730091 8400041
Original 08/98
Page 7
NSE6 Service Tools
PAMS Technical Documentation
Flash Prommer FPS4S (Sales Pack)
The Flash Prommer FPS4S is used to update the main software of the phone. Updating is done by first loading the new MCU software from the PC to the flash prommer, and then loading the new SW from the prommer to the phone. When updating more than one phone in succession, the MCU software only needs to be loaded to the prommer once. The sales pack includes: Flash Prommer FPS4 Charger ACL3E Printer cable D9 D9 Cable AXS4 Installation software for FPS4 Sales package code Flash Prommer FPS4: View of FPS4 0085095 0750090 0680015 0730029 0730090 8400041
NOTE: When flashing NSE6 phone, FPS4 must be upgraded using 1 Mb SRAM module (0200742).
Page 8
Original 08/98
PAMS Technical Documentation
NSE6 Service Tools
Security Box TDF4
The Security Box TDF4 is required for updating MCU software, and infra red testing. Note 1: TDF4 is delivered in deactivated mode. Fill in the enclosed Activation Request Form, and fax to NMP Salo to get the activation code The infra red module JLP1 is not included in the TDF4 sales package
Note 2: Product Code
Security Box TDF4: View of TDF4
0770106
Original 08/98
Page 9
NSE6 Service Tools
PAMS Technical Documentation
Service Audio Box JBA4
The Service Audio Box JBA4 is used between the Service Cable SCH5, MBUS Cable DAU9S, and Audio Cable ADS1. Product Code Service Audio Box JBA4: View of JBA4 0770094
Page 10
Original 08/98
PAMS Technical Documentation
NSE6 Service Tools
Audio Cable ADS1
Audio cable is an adapter routing AF signals (MIC/EAR) from 8 pin modular connector to two BNC connectors. It is used to connect JBA4, SCH5, and DAU9S. Product code Audio Cable ADS1: View of ADS1 0730011
Original 08/98
Page 11
NSE6 Service Tools
PAMS Technical Documentation
D15D15 Cable AXS5
The D15D15 Cable AXS5 is used to connect two 15 pin D connectors. e.g. between FLA5 and FPS4S. Product Code D15D15 Cable AXS5: View of AXS5 0730091
Page 12
Original 08/98
PAMS Technical Documentation
NSE6 Service Tools
DC Charging Cable PCC1
The DC Cable PCC1 is used e.g. to connect FLA5 and TDF4. Product Code DC Cable PCC1 (with modular RJ connector): DC Cable PCC1B (with banana connectors): View of PCC1 0730053 0770050
Original 08/98
Page 13
NSE6 Service Tools
PAMS Technical Documentation
DC Cable SCB3
The DC Cable SCB3 is used to connect the Service Battery to the charger connection Vin of the phone when doing the charger calibration service procedure. Product Code DC Cable SCB3: View of SCB3 0730114
Page 14
Original 08/98
PAMS Technical Documentation
NSE6 Service Tools
MBUS Cable DAU9S
The MBUS Cable DAU9S has a modular connector, and is used with the service Audio Box JBA4, or a modular Tadapter. Product Code MBUS Cable DAU9S: View of DAU9S 0730108
Original 08/98
Page 15
NSE6 Service Tools
PAMS Technical Documentation
Power Cable PCS1
The Power Cable PCS1 is used to connect the module jigs JBT1 and JBS19 to an external power supply. Can be used with FPS4 also. Product Code Power Cable PCS1: View of PCS1 0730012
Page 16
Original 08/98
PAMS Technical Documentation
NSE6 Service Tools
Audio Cable SCA5
Audio cable is an adapter routing AF signals (MIC/EAR) from phones headset connector to the service box JBU5. Product code Audio Cable SCA5: View of SCA5 0730136
Original 08/98
Page 17
NSE6 Service Tools
PAMS Technical Documentation
Service Cable XCM5
XCM5 is a modular cable for flashing. Product code Service Cable XCM5: View of XCM5 0730142
Page 18
Original 08/98
PAMS Technical Documentation
NSE6 Service Tools
Modular Tadapter
The modular Tadapter is a suitable branching unit to provide the needed parallel modular connections. Product Code Modular Tadapter: View of Modular Tadapter 4626134
Original 08/98
Page 19
NSE6 Service Tools
PAMS Technical Documentation
SW Security Device PKD1
SW security device is a piece of hardware enabling the use of the service software when connected to the parallel (LPT) port of the PC. Whitout the dongle present it is not possible to use the service software. Printer or any such device can be connected to the PC through the dongle if needed.
Caution: Make sure thet you have switched off the PC and the printer before making connections! Caution: Do not connected the PKD1 to the serial port. You may damage your PKD1!
Product Code SW Security Device PKD1: View of SW Security Device 0750018
Page 20