Text preview for : C_Adjustment Method_V1R3.pdf part of OLYMPUS C-3040 Zoom S.M.



Back to : OLYMPUS C-3040 Zoom.part | Home

C. ADJUSTMENT METHOD

C-3040 Zoom

C. ADJUSTMENT METHOD
[1] TABLE FOR SERVICING TOOLS .......................................................................... C-2 [2] EQUIPMENT ........................................................................................................... C-2 [3] ADJUSTMENT ITEMS AND ORDER ..................................................................... C-2 [4] SETUP .................................................................................................................... C-2 [5] CONNECTING THE CAMERA TO THE COMPUTER ............................................ C-3 [6] USB STORAGE INFORMATION REGISTRATION ................................................. C-4 [7] ADJUST SPECIFICATIONS ................................................................................... C-5 1. IC501 OSCILLATION FREQUENCY ADJUSTMENT ........................................ C-5 2. 5.1 V (A) VOLTAGE ADJUSTMENT ................................................................... C-5 3. 13.0 V (L) VOLTAGE ADJUSTMENT ................................................................. C-5 4. 7.0 V (L) VOLTAGE ADJUSTMENT ................................................................... C-5 5. LENS ADJUSTMENT ........................................................................................ C-5 6. AWB ADJUSTMENT .......................................................................................... C-6 7. COLOR MATRIX ADJUSTMENT ....................................................................... C-6 8. CCD DEFECT DETECT ADJUSTMENT ........................................................... C-6 9. CCD BLACK POINT DEFECT ADJUSTMENT ................................................. C-6 10. LCD PANEL ADJUSTMENT ........................................................................... C-7 10-1. LCD H AFC ADJUSTMENT ..................................................................... C-7 10-2. LCD GAIN ADJUSTMENT ....................................................................... C-7 10-3. LCD RGB OFFSET ADJUSTMENT ......................................................... C-7 10-4. LCD RED BRIGHTNESS ADJUSTMENT .............................................. C-7 10-5. LCD BLUE BRIGHTNESS ADJUSTMENT ............................................. C-8 10-6. LCD TINT ADJUSTMENT (FOR PAL) ..................................................... C-8 [8] ADJUST VALUES ................................................................................................... C-9 [9] ADJUST ITEMS .................................................................................................... C-10 SIMENS STAR CHART ................................................................................................. C-11 CHECKING OF LENS UNIT .......................................................................................... C-12

SERVER_DIS

C-1

Ver.1/Rev.3

C. ADJUSTMENT METHOD [1] Table for Servicing Tools Ref. No.
J-1 J-2 J-3 J-4 J-5 J-6

C-3040 Zoom

[2] Equipment Number Part code
1 1 1 1 1 1 VJ8-0175 VJ8-0162 VJ8-0165 VJ8-0155 VJ8-0007 1. Oscilloscope 2. Digital voltmeter 3. AC adaptor 4. IBM R -compatible PC 5. DC regulated power supply

Name
Color viewer 5,100 K Siemens star chart Calibration software Extensioncord (ST1/CA2) Extensioncord (SY1/CA2) Chart for color adjustment

[3] Adjustment Items and Order
1. IC501 Oscillation Frequency Adjustment 2. 5.1 V (A) Voltage Adjustment 3. 13.0 V (L) Voltage Adjustment 4. 7.0 V (L) Voltage Adjustment 5. Lens Adjustment 6. AWB Adjustment 7. Color matrix Adjustment 8. CCD Defect Detect Adjustment 9. CCD Black Point Defect Detect Adjustment 10. LCD Panel Adjustment 10-1. LCD H AFC Adjustment 10-2. LCD Gain Adjustment 10-3. LCD RGB Offset Adjustment 10-4. LCD Red Brightness Adjustment 10-5. LCD Blue Brightness Adjustment 10-6. LCD Tint Adjustment (for PAL) Note: 1. If the lens, CCD, board and changing the part in item 58 replace, it is necessary to adjust again. Item 6-8 adjustments should be carried out in sequence. Item 8 and 9 adjustments should be carried out after item 6.

Note: J-1 color viewer is 100 - 110 VAC only.

J-1

J-2

J-3

J-4/J-5

[4] Setup
1. System requirements Windows 95 or 98 IBM R -compatible PC with Pentium processor CD-ROM drive 3.5-inch high-density diskette drive Serial port with standard RS-232C interface or USB port 8 MB RAM Hard disk drive with at least 15 MB available VGA or SVGA monitor with at least 256-color display 2. Installing calibration software 1. Insert the calibration software installation diskette into your diskette drive. 2. Open Explorer. 3. Copy the DSC Cal folder on the floppy disk in the FD drive to a folder on the hard disk. 3. Installing USB drive Install the USB drive with camera or connection kit for PC.

J-6

SERVER_DIS

C-2

Ver.1

C-3040 Zoom C. ADJUSTMENT METHOD [5] Connecting the camera to the computer
1. Turn off both camera and computer. 2. Line up the arrow on the serial cable connector with the notch on the camera's serial port. Insert the connector. In case of USB cable, line up the arrow on the USB cable connector with the notch on the camera's USB port. Insert the connector. 3. Line up the serial connector on the serial cable with the serial port on your computer, and insert the connector. In case of USB cable, line up the USB connector on the USB cable with the USB port on your computer, and insert the connector. 4. Turn on the camera and your computer system.

AC adaptor

USB cable Serial cable

To serial port or USB port

Ver.1

C-3

SERVER_DIS

C. ADJUSTMENT METHOD [6] USB STORAGE INFORMATION REGISTRATION
USB storage data is important for when the camera is connected to a computer via a USB connection. If there are any errors in the USB storage data, or if it has not been saved, the USB specification conditions will not be satisfied, so always check and save the USB storage data. Preparation: POWER switch: ON Adjustment method: 1. Connect the camera to a computer. (Refer to [5] Connecting the camera to the computer on the page C-3.) 2. Double-click on the DscCalDi126. 3. Click on the Get button in the USB storage window and check the USB storage data. VID: OLYMPUS PID: C-3040ZOOM Serial: Rev. : 1.00 4. Check the "Serial" in the above USB storage data. If the displayed value is different from the serial number printed on the base of the camera, enter the number on the base of the camera. Then click the Set button. 5. Next, check VID, PID and Rev. entries in the USB storage data. If any of them are different from the values in 3. above, make the changes and then click the corresponding Set button.
Calibration AWB Focus UV Matrix Cal Mode OK Cal Data OK Setting
Language

C-3040 Zoom

Upload Firmware Image Initialize EVF LCD Type

LCD R Bright RGB Offset Tint H AFC

B Bright Gain Phase Test

VCOMDC VCOMPP

USB strage Get VID Set PID

Set Serial Set Rev.

Set Set

Video Mode

SERVER_DIS

C-4

Ver.1

C-3040 Zoom [7] Adjust Specifications
[ST1 board (Side B)]

C. ADJUSTMENT METHOD
Adjustment method: 1.Adjust with VR504 to 13.00 ± 0.05 V.

4. 7.0 V (L) Voltage Adjustment
VR501 CL524 (Side A) VR504 VR502 CL566 VR505 CL522 CL501 (Side A) Q5001 Collector (Side A)
Measuring Point Measuring Equipment ADJ. Location ADJ. Value

CL566 Digital voltmeter VR505 7.00 ± 0.05 V

Adjustment method: 1. Adjust with VR505 to 7.00 ± 0.05 V.

5. Lens Adjustment

Note: 1. Voltage adjustment is necessary to repair in the ST1 board and replace the parts. 2. Carry out adjustment with disconnect wires for storbe. Preparation: 1. Connect the SY1 board (CN301) and the CA2 board (CN106) with extension cord. (VJ8-0165) 2. Connect the ST1 board (CN501) and the CA2 board (CN104) with extension cord. (VJ8-0162) 3. Connect LCD panel. 4. Insert the card. 5. Turn on the power switch, and then set the camera mode.

Serial cable

Camera

150 cm ± 3 cm Siemens star chart

1. IC501 Oscillation Frequency Adjustment
Measuring Point Measuring Equipment ADJ. Location ADJ. Value

Setting the adjustment mode
1. Open the card cover of the camera. 2. Push the menu button and LCD button more than 3 seconds simultaneously. Display "CAMERA CONTROL OFF". 3. Push the right arrow button and below arrow button, and select "ON". 4. Push the OK button twice. 5. Close the card cover of the camera. Preparation: POWER switch: ON Adjustment condition: Siemens star chart (A3) Fluorescent light illumination with no flicker (incandescent light cannot be used.) Illumination above the subject should be 400 lux ± 10%. Adjustment method: 1. Set the siemens star chart 150 cm ± 3 cm so that it becomes center of the screen. 2. Double-click on the DscCalDi126. 3. Click the "Focus", and Click the "Yes". 4. Lens adjustment value will appear on the screen. 5. Click the OK.

Q5001 Collector or CL501 Frequency counter VR501 200 ± 1 kHz

Adjustment method: 1. Adjust with VR501 to 200 ± 1 kHz.

2. 5.1 V (A) Voltage Adjustment
Measuring Point Measuring Equipment ADJ. Location ADJ. Value

CL524 Digital voltmeter VR502 5.10 ± 0.05 V

Adjustment method: 1. Adjust with VR502 to 5.10 ± 0.05 V.

3. 13.0 V (L) Voltage Adjustment
Measuring Point Measuring Equipment ADJ. Location ADJ. Value

CL522 Digital voltmeter VR504 13.00 ± 0.05 V

Ver.1

C-5

SERVER_DIS

C. ADJUSTMENT METHOD 6. AWB Adjustment

C-3040 Zoom

4. Click the "UV Matrix", and Click the "Yes". 5. Adjustment values will appear on the screen. 6. Click the OK.

8. CCD Defect Detect Adjustment
Preparation: POWER switch: ON Adjustment method: 1. Double-click on the DscCalDi126. 2. Select "CCD Defect" on the LCD "Test", and click the "Yes". 3. After the adjustment is completed, OK will display. 4. Click the OK.

Serial cable

9. CCD Black Point Defect Detect Adjustment
Camera

All white pattern Color viewer (5,100K)

Preparation: POWER switch: ON Adjusting method: 1. When setting the camera in place, set it to an angle so that nothing appears in any part of the color viewer except the white section. (Do not enter any light.) 2. Double-click on the DscCalDi126. 3. Click the "AWB", and click the "Yes". 4. AWB adjustment value will appear on the screen. 5. Click the OK.

Serial cable

Camera

7. Color Matrix Adjustment

All white pattern Color viewer (5,100K)

Serial cable

Preparation: POWER switch: ON Adjustment method: 1. When setting the camera in place, set it to an angle so that nothing appears in any part of the color viewer except the white section. 2. Double-click on the DscCalDi126. 3. Select "CCD Black" on the LCD "Test", and click the "Yes". 4. After the adjustment is completed, OK will display. 5. Click the OK.

Camera 15 cm ± 1 cm All white pattern color viewer (5,100K) and color matrix adjustment chart

Preparation: POWER switch: ON Adjustment method: 1. Set the color adjustment chart to the color viewer. (Do not enter any light.) 2. Set the color adjustment chart so that it becomes center of the screen. 3. Double-click on the DscCalDi126.

SERVER_DIS

C-6

Ver.1

C-3040 Zoom 10. LCD Panel Adjustment
[CA2 board (Side A)]

C. ADJUSTMENT METHOD 10-3. LCD RGB Offset Adjustment
Adjusting method: 1. Adjust LCD "RGB Offset" so that the amplitude of the CL415 waveform is 4.6 V ± 0.1 Vp-p. Note: 10-2. LCD Gain adjustment should always be carried out first.

CL413 CL414 CL415

4.6V ±0.1Vp-p

CL415 waveform

10-1. LCD H AFC Adjustment
Preparation: POWER switch: ON Adjusting method: 1. Double-click on the DscCalDi126. 2. Select 0 on the LCD "H AFC". 3. While watching the LCD monitor, adjust "H AFC" so that the edge of the LCD adjustment frame are the same distance from the left and right edge of the LCD screen. (A = B)

10-4. LCD Red Brightness Adjustment
Adjusting method: 1. Adjust LCD "R Bright" so that the amplitude of the CL414 waveform is VG± 0.1 Vp-p with respect to the CL415 (VG) waveform. Note: 10-2. LCD Gain adjustment and 10-3. LCD RGB Offset adjustment should always be carried out first.

LCD screen A

LCD adjustment B frame

VG

FPC

CL415 waveform

10-2. LCD Gain Adjustment
Adjusting method: 1. Adjust LCD "Gain" so that the amplitude of the CL415 waveform is 1.0 V ± 0.1 Vp-p.

VG± 0.1Vp-p

1.0V ±0.1Vp-p CL414 waveform

CL415 waveform

Ver.1

C-7

SERVER_DIS

10-5. LCD Blue Brightness Adjustment

C. ADJUSTMENT METHOD 10-6. LCD Tint Adjustment (for PAL)

C-3040 Zoom

Adjusting method: 1. Adjust LCD "B Bright" so that the amplitude of the CL413 waveform is VG ± 0.1 Vp-p with respect to the CL415 (VG) waveform. Note: 10-2. LCD Gain adjustment and 10-3. LCD RGB Offset adjustment have done.

Adjusting method: 1. Adjust "Tint" so that the amplitude of CL415 waveform is minimum. Note: 10-6. LCD TINT adjustment should always be carried out last.

a

VG a

CL415 waveform a

VG± 0.1Vp-p

a

CL413 waveform

Completing the adjustment mode
1. Open the card cover of the camera. 2. Push the menu button and LCD button more than 3 seconds simultaneously. Display "CAMERA CONTROL ON". 3. Push the right arrow button and above arrow button, and select "OFF". 4. Push the OK button twice. 5. Close the card cover of the camera.

SERVER_DIS

C-8

Ver.1

C-3040 Zoom

C. ADJUSTMENT METHOD
(2) AWB adjustment ranges

[8 ] Adjustment Values
Explanation of adjustment values
Adjustment values are values which have been estimated statistically from the distribution of adjustment values obtained from similar machine models and prototypes. Accordingly these values should be used as a guide only. Because these values are guides, equipment which is in good working order may still produce values which are outside the adjustment value ranges, so that the equipment should be operated in order to determine whether it is in fact operational or defective.

Range of adjustment values
(1) Lens adjustment ranges

[How to read a dialog of adjustment value] "WD=WD1,WD2,WD3" [Adjustment value] WD1: 200 to 400 WD2: 128(fixed value) WD3: 200 to 400

(3) Color matrix adjustment ranges

[Adjustment value] STD_AFPOS : Within 15 and 120 Note :STD_AFPOS = " 0 " means NG. [How to read a dialog of adjustment value] "UD=UD0,UD1,UD2,UD3" "UC=UC0,UC1,UC2,UC3" [Adjustment value] UD0: 40 to 160 UD1: 180 to 256, 0 to 60 UD2: 180 to 256, 0 to 60 UD3: 40 to 160 Adjustment values are normal except following cases. It does not detect any signal from CCD. In this case, adjustment values are all "1". UD0: 1 UD1: 1 UD2: 1 UD3: 1

Ver.1

C-9

SERVER_DIS

C. ADJUSTMENT METHOD

C-3040 Zoom

[9] Adjustment Items Changed repair parts LENS CA1 ST1 ¡ ¡ ¡ ¡ ¡ ¡ ¡ ¡ ¡ ¡ ¡ ¡ ¡ ¡

Adjustment items
1 IC501 Oscillation Frequency Adjustment 2 5.1V(A) Voltage Adjustment 3 13.0V(L) Voltage Adjustment 4 7.0V(L) Voltage Adjustment 5 Lens Adjustment 6 AWB Adjustment 7 Color Matrix Adjustmen 8 CCD Defect Detect Adjustment 9 CCD Black Point Detect Adjustment 10-1 LCD H AFC Adjustment 10-2 LCD Gain Adjustment 10-3 LCD RGB Offset Adjustment 10-4 LCD Red Brightness Adjustment 10-5 LCD Blue Brightness Adjustment 10-6 LCD Tint Adjustment (For PAL)

CCD

CA2

¡ ¡ ¡ ¡ ¡

¡ ¡ ¡ ¡ ¡ ¡ ¡ ¡ ¡ ¡ ¡

note)There is no need that you adjust the provided ST1when changing it without changing the parts of component level.

SERVER_DIS

C-10

Ver.1

C-3040 Zoom

C. ADJUSTMENT METHOD

Ver.1

C-11

SERVER_DIS

C.ADJUSTMENT METHOD CHECKING OF LENS UNIT
1. Check Item 1)Backlash Pulse of LD 2)LD ERROR Pulse 3)Basklash Pulse of ZOOM 4)ZOOM ERROR Pulse 2. Tools FPC-Adaptor 14 PINS for K-FPC FPC-Adaptor 16 PINS for S-FPC

C-3040ZOOM

Part No.
1 2 3 4 5 KC0331 KC0334 KC0338 FPC-Adaptor FPC-Adaptor

Description
Lens Checker LCK1 Connector Cable P5 Clip Connector 17 14-PINS for K-FPC 16-PINS for S-FPC

Q'ty
1 1 2 1 1 3. Checking Prosedure

The last 2 digits are meaning the number of Pin. Ex.) 080-14 :14PINS

080-10

Fi x 2 FPC-Adaptors (14 and 16 PINS) to ClipConnector 17. Connect Connector Cable P5, Clip Connector 17 and Lens Checker LCK-1 1) AUTO I. Tum on Lens Checker LCK-1 I n i t i a l S e t t i n g

Lens Checker LCK-1 II. Set AUTO / MANU SW at AUTO III.Set Dial SW at 5 IV. Set CW / CCW SW at CW LCK-1 PUSH Ver.1 START 0 SW Auto

(0 : Number of Dial SW 0-5) Connector Cable P5 V. Connect the both FPCs (K-FPC and S-FPC) to Clip Connectors. Hold a lens unit by hand, and keep it horizontally. VI. Push START SW. (More than 0.2 sec.) LCK-1 ZOOM Ver.1 RESET 0 Auto

Clip Connector 17

C-12

Ver. 1/Rev.3

C-3040ZOOM

C.ADJUSTMENT METHOD In case of GOOD LCK-1 Ver.1 0 Auto PUSH START SW LB1 D1 ZB1 D12 GOOD

When an error occurs, an error is indicated, and it stops. LCK-1 LD Ver.1 0 Auto

RESET

LCK-1 LD LB*

Ver.1

0 CHK

Auto

In case of NG : LCK-1 Ver.1 0 Auto PUSH START SW LB D6 NO GOOD ZM D Err

BACKLASH

* is BACKLASH PULSE of LD LCK-1 LD LB1 D D* Ver.1 CHK 0 Auto ERROR is indicated (The indication which isn't being explained is the condition of PR and PI.) When CW/CCW SW is set at CCW, the automatic check of * is LD ERROR PULSE LCK-1 Ver.1 0 Auto the motor chosen with a LD/ZOOM SW is done. 2) Manual I. Set AUTO/MANU SW at MANU LCK-1 * is BACKLASH PLUSE of ZOOM LCK-1 Ver.1 ZOOM D CHK LB1 D1 ZB1 0 D** Auto The contents chosen with the LD/ZOOM SW and the CW/ CCW SW indicated in LCD. II. Push START SW (More than 0.2 sec.) LCKLD MOVE When a motor works, "MOVE" is indicated in LCD. Ver.1 0 CW Manu LD Ver.1 0 CW Manu

ZOOM BACKLASH CHK LB1 D1 ZB *

* * is ZOOM ERROR PULSE (ZOOM AREA : SET-UP AREA)

Ver. 1/Rev.3

C-13

C.ADJUSTMENT METHOD
LD Motor When PI signal 500 pulses (500pps) are changed,LD motor stops CW : Turn Out ZOOM Motor When PI signal 2200 pulses (300pps) are changed, ZOOM motor stops CW : W to T 4. CCW : T to W CCW : Tum In

C-3040ZOOM

Others Turn off LCK-1 promptly if something is wrong. ERROR Indication

5,

PI, PR Err : PI or PR Pulse does not change. LD BK Err : LD BACKLASH PULSE is out of standard. LD D Err : LD Pulse Error ZD BK Err : ZOOM BACKLASH PULSE is out of standard ZD D Err : ZOOM Pulse Error

C-14

Ver. 1/Rev.3