Text preview for : dcr-hc20eadj[1]..pdf part of Sony DCR-HC16E/HC18E/HC20/HC20E Service Manual



Back to : Sony DCR-HC16E-HC18E-HC20 | Home

DCR-HC16E/HC18E/ HC20/HC20E
RMT-830
Ver 1.0 2004. 02
Revision History How to use Acrobat Reader

SECTION 6 ADJUSTMENTS

ADJ

Link
Before starting adjustment
Adjusting items when replacing main parts and boards

VIDEO SECTION ADJUSTMENT
PREPARATIONS BEFORE ADJUSTMENTS SYSTEM CONTROL SYSTEM ADJUSTMENT

CAMERA SECTION ADJUSTMENT
SERVO AND RF SYSTEM ADJUSTMENT PREPARATIONS BEFORE ADJUSTMENT VIDEO SYSTEM ADJUSTMENTS INITIALIZATION OF 8, A, C, D, E, F, 1C, 1F PAGE DATA AUDIO SYSTEM ADJUSTMENTS CAMERA SYSTEM ADJUSTMENTS ELECTRONIC VIEWFINDER SYSTEM ADJUSTMENT LCD SYSTEM ADJUSTMENT

SERVICE MODE
ADJUSTMENT REMOTE COMMANDER DATA PROCESS

MECHANISM SECTION ADJUSTMENT
SERVICE MODE HOW TO ENTER RECORD MODE WITHOUT CCASSETTE HOW TO ENTER PLAYBACK MODE WITHOUT CCASSETTE TAPE PATH ADJUSTMENT
Contents of LEVEL 2 and LEVEL 3 Service Manual
CONTENTS 1. SERVICE NOTE 2. DISASSEMBLY 3. BLOCK DIAGRAMS 4. PRINTED WIRING BOARDS AND SCHEMATIC DIAGRAMS LEVEL 2 a a OVERALL POWER CD-489, PD-213, LB-095, SE-141, JK-260, IR-051, MS-200, FP-836 BOARD, CONTROL KEY BLOCK (SB6300, SS6300, CF6300), FP-228, FP-467, FP-826, FP-830 FLEXIBLE EXPLODED VIEWS ELECTRICAL PARTS LEVEL 3 VC-350 BOARD

5. REPAIR PARTS LIST

a (VC-350 BOARD)

DCR-HC16E/HC18E/HC20/HC20E
TABLE OF CONTENTS 6.
1. 1-1. 6-1. 1-1.

ADJUSTMENT

Before starting adjustment ··············································· 6-1 Adjusting items when replacing main parts and boards. ··· 6-2 CAMERA SECTION ADJUSTMENT ··························· 6-4 PREPARATIONS BEFORE ADJUSTMENT (CAMERA SECTION) ··················································· 6-4 1-1-1. List of Service Tools ························································ 6-4 1-1-2. Preparations ····································································· 6-5 1-1-3. Precaution ········································································ 6-7 1. Setting the Switch ···························································· 6-7 2. Order of Adjustments ······················································ 6-7 3. Subjects ··········································································· 6-7 1-2. INITIALIZATION OF 8, A, C, D, E, F, 1C, 1F PAGE DATA ···································································· 6-8 1-2-1. INITIALIZATION OF A, D PAGE DATA ······················ 6-8 1. Initializing the A, D Page Data ········································ 6-8 2. Modification of A, D Page Data ······································ 6-8 3. A Page Table ···································································· 6-9 4. D Page Table ···································································· 6-9 1-2-2. INITIALIZATION OF 8, C, 1C PAGE DATA ·············· 6-10 1. Initializing the 8, C, 1C Page Data ································ 6-10 2. Modification of 8, C, 1C Page Data ······························ 6-10 3. 8 Page Table ··································································· 6-11 4. C Page Table ·································································· 6-11 5. 1C Page Table ································································ 6-13 1-2-3. INITIALIZATION OF E, F, 1F PAGE DATA ··············· 6-14 1. Initializing the E, F, 1F Page Data ································· 6-14 2. Modification of E, F, 1F Page Data ······························· 6-14 3. E Page Table ·································································· 6-15 4. F Page Table ·································································· 6-15 5. 1F Page Table ································································ 6-17 1-3. CAMERA SYSTEM ADJUSTMENTS ························ 6-18 36MHz Origin Oscillation Adjustment (VC-350 board) ····· 6-18 1. 2. HALL Adjustment ························································· 6-18 3. Flange Back Adjustment (Using Minipattern Box) ······· 6-19 4. Flange Back Adjustment (Using Flange Back Adjustment Chart and Subject More Than 500m Away) ·················· 6-20 4-1. Flange Back Adjustment (1) ·········································· 6-20 4-2. Flange Back Adjustment (2) ·········································· 6-20 5. Flange Back Check ························································ 6-21 6. Optical Axis Adjustment ··············································· 6-22 7. Picture Frame Setting ···················································· 6-23 8. Color Reproduction Adjustment ···································· 6-24 9. MAX GAIN Adjustment ··············································· 6-25 10. LV Standard Data Input ················································· 6-25 11. Auto White Balance Standard Data Input ····················· 6-26 12. Auto White Balance Adjustment ··································· 6-26 13. White Balance Check ···················································· 6-27 14. Steady Shot Check ························································· 6-28 1-4. ELECTRONIC VIEWFINDER SYSTEM ADJUSTMENT ····························································· 6-29 1. EVF Automatic Adjustment (VC-350 board) ················ 6-29 1-5. LCD SYSTEM ADJUSTMENT ··································· 6-30 1. LCD Automatic Adjustment (PD-213 board) ················ 6-30 2. V COM Adjustment (PD-213 board) ···························· 6-31 3. Transmissive Mode White Balance Adjustment (PD-213 board) ······························································ 6-31 4. Reflective Mode White Balance Adjustment (PD-213 board) ······························································ 6-32 6-2. MECHANISM SECTION ADJUSTMENT ·················· 6-33 2-1. HOW TO ENTER RECORD MODE WITHOUT CASSETTE ··································································· 6-33 2-2. HOW TO ENTER PLAYBACK MODE WITHOUT CASSETTE ··································································· 6-33 2-3. TAPE PATH ADJUSTMENT ········································ 6-33 1. Preparation for Adjustment ··········································· 6-33 2. Processing after Completing Operations: ······················ 6-33

6-3. VIDEO SECTION ADJUSTMENT ······························ 6-34 3-1. PREPARATIONS BEFORE ADJUSTMENTS ············ 6-34 3-1-1. Equipment to Required ·················································· 6-34 3-1-2. Precautions on Adjusting ··············································· 6-35 3-1-3. Adjusting Connectors ···················································· 6-36 3-1-4. Connecting the Equipment ············································ 6-36 3-1-5. Alignment Tapes ···························································· 6-37 3-1-6. Input/Output Level and Impedance ······························· 6-37 3-2. SYSTEM CONTROL SYSTEM ADJUSTMENT ········ 6-38 1. Initialization of 8, A, C, D, E, F, 1C, 1F Page Data ······ 6-38 2. Touch Panel Adjustment ················································ 6-38 3. Serial No. Input ····························································· 6-39 3-1. Company ID Input ························································· 6-39 3-2. Serial No. Input ····························································· 6-39 3-3. SERVO AND RF SYSTEM ADJUSTMENT ··············· 6-41 1. Cap FG Duty Adjustment (VC-350 Board) ··················· 6-41 2. Switching Position Adjustment (VC-350 Board) ·········· 6-41 3. Error Rate Check ··························································· 6-42 3-1. Preparations before adjustments ···································· 6-42 3-2. Error Rate Check ··························································· 6-42 3-3. Processing after Completing Adjustments ···················· 6-42 3-4. VIDEO SYSTEM ADJUSTMENTS ····························· 6-43 S VIDEO OUT Y Level Adjustment (VC-350 Board) ···· 6-43 1. 2. S VIDEO OUT Chroma Level Adjustment (VC-350 Board) ····························································· 6-43 3. VIDEO OUT Y, Chroma Level Check (VC-350 Board) ··· 6-44 3-5. AUDIO SYSTEM ADJUSTMENTS ···························· 6-45 1. Playback Level Check ··················································· 6-46 2. Overall Level Characteristics Check ····························· 6-46 3. Overall Distortion Check ··············································· 6-46 4. Overall Noise Level Check ············································ 6-46 5. Overall Separation Check ·············································· 6-46 6-4. SERVICE MODE ·························································· 6-47 4-1. ADJUSTMENT REMOTE COMMANDER ················ 6-47 1. Using the adjustment remote commander ····················· 6-47 2. Precautions upon using the adjustment remote commander ························································ 6-47 4-2. DATA PROCESS ··························································· 6-48 4-3. SERVICE MODE ·························································· 6-49 1. Setting the Test Mode ···················································· 6-49 2. Emergence Memory Address (Camera section) ············ 6-49 2-1. EMG Code (Emergency Code) ······································ 6-49 3. Emergence Memory Address (Mechanism section) ······ 6-49 3-1. EMG Code (Emergency Code) ····································· 6-49 3-2. MSW Code ···································································· 6-50 4. Bit value discrimination ················································ 6-51 5. Switch check (1) ···························································· 6-51 6. Switch check (2) ···························································· 6-51 7. Switch check (3) ···························································· 6-51 8. Switch check (4) ···························································· 6-52 9. Switch check (5) ···························································· 6-52 10. LED check ····································································· 6-53 11. Record of Use check (1) ················································ 6-53 12. Record of Use check (2) ················································ 6-53 13. Record of Self-diagnosis check ····································· 6-54 * Optical axis frame is shown on page 6-56. Color reproduction frame is shown on page 6-57.

--2--

DCR-HC16E/HC18E/HC20/HC20E SECTION 6 ADJUSTMENTS
1. Before starting adjustment EVR Data Re-writing Procedure When Replacing Board
The data that is stored in the repair board, is not necessarily correct. Perform either procedure 1 or procedure 2 or procedure 3 when replacing board.

Procedure 1
Save the EVR data of the machine in which a board is going to be replaced. Download the saved data after a board is replaced.
(Machine before starting repair) PC PC (Machine after a board is replaced)

Save the EVR data to a personal computer.

Download the saved data to a machine.

Procedure 2
Remove the EEPROM from the board of the machine that is going to be repaired. Install the removed EEPROM to the replaced board.
Remove the EEPROM and install it.

(Former board)

(New board)

Procedure 3
When the data cannot be saved due to defective EEPROM, or when the EEPROM cannot be removed or installed, save the data from the same model of the same destination, and download it.
(Machine to be repaired) PC (Machine to be repaired)

Download the data.

Save the data.

(The same model of the same destination)

After the EVR data is saved and downloaded, check the respective items of the EVR data. (Refer to page 6-3 for the items to be checked.)

6-1

DCR-HC16E/HC18E/HC20/HC20E

1-1. Adjusting items when replacing main parts and boards.
· Adjusting items when replacing main parts
When replacing main parts, adjust the items indicated by z in the following table. Note: When replacing the drum assy. or the mechanism deck, reset the data of page: 7, address: A7 to A9 to "00". (Refer to "Record of Use check" of "6-4. SERVICE MODE")

Block replacement

Replaced parts Parts replacement

Adjustment Section

Adjustment

Initialization of 8, A, C, D, E, F, 1C, 1F page data

Camera

EVF

LCD

Mechanism System control

Servo, RF

Video

Initialization of A, D page data Initialization of 8, C, 1C page data Initialization of E, F, 1F page data 36MHz origin oscillation adj. HALL adj. Flange back adj. Optical axis adj. Color reproduction adj. MAX GAIN adj. LV standard data input AWB standard data input Auto white balance adj. Steady shot check EVF automatic adj. LCD automatic adj. V COM adj. Transmissive mode white balance adj. Reflective mode white balance adj. Tape path adj. Touch panel adj. Serial No. input CAP FG duty adj. Switching position adj. Error rate check S VIDEO OUT Y level adj. S VIDEO OUT chroma level adj.

z z z

Table. 6-1-1(1).

6-2

Lens device Mechanism deck (Note) LCD block LCD901 (LCD panel) LCD block (backlight LED) Mechanism deck M901 (Drum assy) (Note) Mechanism MD block CD-489 board IC101 (CCD imager) PD-213 board IC602 (RGB driver, Timing generator (LCD)) SE-141 board SE401/402 (PITCH /YAW sensor) VC-350 board IC3001, X3001 (Timing generator) VC-350 board IC3002 (S/H, A/D conv.) VC-350 board IC6001 (Camera DV RF signal process.) VC-350 board IC6501 (REC/PB AMP) VC-350 board IC7001 (Video output) VC-350 board IC9201 (EVR) VC-350 board IC9301 (RGB driver, Timing generator (EVF))
z z z z z z z z z z z z z z z z z z z z z z z z z z z z z z z z z z z z z z z z z z z z z

DCR-HC16E/HC18E/HC20/HC20E

· Adjusting items when replacing a board or EEPROM When replacing a board or EEPROM, adjust the items indicated by z in the following table. Board EEPROM replacement replacement

VC-350 board IC8602 (EEPROM)

Adjustment Section

Adjustment

CD-489 board (COMPLETE) PD-213 board (COMPLETE) SE-141 board (COMPLETE) VC-350 board (COMPLETE)

Initialization of 8, A, C, D, E, F, 1C, 1F page data

Camera

EVF

LCD

Mechanism System control

Servo, RF

Video

Initialization of A, D page data Initialization of 8, C, 1C page data Initialization of E, F, 1F page data 36MHz origin oscillation adj. HALL adj. Flange back adj. Optical axis adj. Color reproduction adj. MAX GAIN adj. LV standard data input AWB standard data input Auto white balance adj. Steady shot check EVF automatic adj. LCD automatic adj. V COM adj. Transmissive mode white balance adj. Reflective mode white balance adj. Tape path adj. Touch panel adj. Serial No. input CAP FG duty adj. Switching position adj. Error rate check S VIDEO OUT Y level adj. S VIDEO OUT chroma level adj.

z z z z z z z

z z z z z z z z z z z z z z z z z z z z z z z z z z z z z z

z z z z z z z z z z z z z z z z z z z z z z z z z

z z

z z z z z z z

z

z z z

Table. 6-1-1(2).

6-3

Supporting

DCR-HC16E/HC18E/HC20/HC20E

6-1. CAMERA SECTION ADJUSTMENT
1-1. PREPARATIONS BEFORE ADJUSTMENT (CAMERA SECTION)
· Vectorscope J-2 Filter for color temperature correction (C14) J-6080-058-A ND filter 1.0 J-6080-808-A ND filter 0.4 J-6080-806-A ND filter 0.1 J-6080-807-A J-4 Color chart for pattern box J-6020-250-A J-5 Adjustment remote commander (RM-95 upgraded) J-6082-053-B J-6 J-3

1-1-1. List of Service Tools · Oscilloscope · Color monitor J-1

Pattern box PTB-450 J-6082-200-A

Siemens star chart J-6080-875-A

J-7 Clear chart for pattern box J-6080-621-A

J-8

J-9

Mini pattern box J-6082-353-B

Camera table J-608A-384-A

J-10

A

A: CPC-15 J-6082-564-A B: I/F unit for LANC control J-6082-521-A

B

Fig. 6-1-1.

6-4

DCR-HC16E/HC18E/HC20/HC20E

1-1-2.

Preparations
Pattern box

Note1: For details of how remove the cabinet and boards, refer to "2. DISASSEMBLY". Note2: When performing only the adjustments, the lens block and boards need not be disassembled. Note3: Before performing the adjustments, check the data of page: 0, address: 10 is "00". If not, set data: 00 to this address.

1)

Connect the equipment for adjustments according to Fig. 6-13.

1.0 m

Note4: As removing the MS-200 board (removing CN1005 of the VC350 board) means removing the lithium 3V power supply (BT501 on the MS-200 board), data such as date, time, user-set menus will be lost. After completing adjustments, reset these data. But the self-diagnosis data and the data on history of use (total drum rotation time etc.) will be kept even if the lithium 3V power supply is removed. (Refer to "6-4.Service Mode" for the selfdiagnosis data and the data on history of use.) Note5: Setting the "Forced Camera Power ON" Mode 1) Select page: 0, address: 01, and set data: 01. 2) Select page: D, address: 10, set data: 01, and press the PAUSE button. The above procedure will enable the camera power to be turned on with the control key block (SS6300) removed. After completing adjustments, be sure to exit the "Forced Camera Power ON Mode". (Operate the camera functions using the touch panel. When the control key block (SS6300) is removed, the function buttons of the adjustment remote commander are not effective even if the HOLD switch of the adjustment remote commander is set to the OFF position.) Note6: Exiting the "Forced Camera Power ON" Mode

Front of the lens

Fig. 6-1-2.

1) 2) 3)

Select page: 0, address: 01, and set data: 01. Select page: D, address: 10, set data: 00, and press the PAUSE button. Select page: 0, address: 01, and set data: 00.

6-5

DCR-HC16E/HC18E/HC20/HC20E

[CONNECTION OF EQUIPMENT]
For tape path adjustment

Not used BATT LANC Not used

CN001 6 7 4 5 1 3 3 2

CPC-15 (J-6082-564-A) 8 Not used *1 *1 1 LANC jack Adjustment remote commander (RM-95)

CN002
1 RF MON 2 SWP 3 GND 4 XSC EEP 5 EEP SCK 6 EEP SO 7 EEP SI

Not used.

I/F unit for LANC control (J-6082-521-A)

*1: Don't connect any cable to these connectors. CPC lid DC-IN connector

Screw (M1.7x4) black

AC IN

AC power adaptor

Fig. 6-1-3.

6-6

DCR-HC16E/HC18E/HC20/HC20E

1-1-3. Precaution 1. Setting the Switch Unless otherwise specified, set the switches as follows and perform adjustments without loading cassette. 1. 2. 3. 4. 5. 6. MODE switch (SS6300 block) .............................. CAMERA NIGHT SHOT switch (Lens block) ................................. OFF BACK LIGHT switch (CF6300 block) ............................ OFF FOCUS (Touch panel) .......................................... MANUAL EXPOSURE (Touch panel) .............................................. OFF MENU settings (Touch panel) MANUAL SET menu PROGRAM AE .................................................... AUTO PICTURE EFECT .................................................... OFF WHITE BALANCE ............................................. AUTO CAMERA SET menu DIGITAL ZOOM ..................................................... OFF 16:9 WIDE ................................................................ OFF STEADY SHOT ....................................................... OFF SETUP menu DEMO MODE ......................................................... OFF

2. Order of Adjustments Basically carry out adjustments in the order given.

Color bar chart (Color reproduction adjustment frame )
Yellow Cyan Green White Magenta Red

Electronic beam scanning frame

H

C
Blue

C=D

D
Yellow Cyan Green White Magenta Red Blue

CRT picture frame

V A B A=B B A Enlargement

Fig. b (TV monitor picture)

Fig. a (Video output terminal output waveform)

Difference in level

B

A

Adjust the camera zoom and direction to obtain the output waveform shown in Fig. a and the TV monitor display shown in Fig. b.

Fig.6-1-4.
3. Subjects 1) Color bar chart (Color reproduction adjustment frame) When performing adjustments using the color bar chart, adjust the picture frame as shown in Fig. 6-1-4. (Color reproduction adjustment frame) 2) Clear chart (Color reproduction adjustment frame) Remove the color bar chart from the pattern box and insert a clear chart in its place. (Do not perform zoom operations during this time.) 3) Flange back adjustment chart Make the chart shown in Fig. 6-1-5 using A0 size (1189mm × 841mm) black and white vellum paper.

White 841mm Black

1189mm

Fig. 6-1-5.
Note: Use matte vellum paper bigger than A0, and make sure the edges of the black and white paper joined together are not rough.

6-7

DCR-HC16E/HC18E/HC20/HC20E

1-2.

INITIALIZATION OF 8, A, C, D, E, F, 1C, 1F PAGE DATA

Note: When reading or writing the 1C or 1F page data, select page: 0, address: 10, and set data: 01, then select C or F page. The 1C or 1F page can be chosen by this data setting. After reading or writing, reset the data of page: 0, address: 10 to "00".

2. Modification of A, D Page Data If the A, D page data has been initialized, change the data of the "Fixed data-2" address shown in the following tables by manual input. Modifying Method: 1) Before changing the data, select page: 0, address: 01, and set data: 01. 2) New data for changing are not shown in the tables because they are different in destination. When changing the data, copy the data built in the same model.
Note: If copy the data built in the different model, the camcorder may not operate.

1-2-1.

INITIALIZATION OF A, D PAGE DATA

Note: The data of page: 0, address: 10 must be "00".

1. Initializing the A, D Page Data
Note1: If the A, D page data has been initialized, the following adjustments need to be performed again. 1) Modification of A, D page data 2) Touch panel adjustment

3)

When changing the data, press the PAUSE button of the adjustment remote commander each time when setting new data to write the data in the non-volatile memory.

Adjusting page Adjusting Address Adjusting page Adjusting Address

A 10 to FF D 10 to 7F

Processing after Completing Modification of A, D Page data Order Page Address Data Procedure 1 2 00 29 Set the data. 2 2 01 29 Set the data, and press PAUSE button.
Note: If the following symptoms occur after completing of the "Modification of A, D page data", check that the data of addresses: 1A to 39 of A page and the data of addresses: 12 to 19 of D page are same as those of the same model of the same destination. 1) The self-diagnosis code "E:20:00" on the LCD screen is displayed. 2) The power is shut off so that unit cannot operate.

Initializing Method: Order Page Address Data Procedure 1 0 01 01 Set the data. 2 7 03 Set the following data. 01 (DCR-HC20 (NTSC)) 81 (DCR-HC16E/HC18E/HC20E (PAL)) 3 7 00 XX Set the data. (Note2) 4 7 01 XX Set the data, and press PAUSE button. (Note2) 5 7 02 Check that the data changes to "01" 6 Perform "Modification of A, D Page Data".
Note2: XX=20: Initializing A page XX=22: Initializing D page XX=28: Initializing A and D pages

6-8

DCR-HC16E/HC18E/HC20/HC20E

3. A Page Table
Note1: The data of page: 0, address: 10 must be "00". Note2: Fixed data-1: Initialized data. (Refer to "1. Initializing the A, D Page Data".) Fixed data-2: Modified data. (Refer to "2. Modification of A, D Page Data").

4. D Page Table
Note1: The data of page: 0, address: 10 must be "00". Note2: Fixed data-1: Initialized data. (Refer to "1. Initializing the A, D Page Data".) Fixed data-2: Modified data. (Refer to "2. Modification of A, D Page Data").

Address Initial value NTSC PAL 00 to 0F 10 to 19 1A 1B to 1F 20 21 to 30 31 32 33 to 38 39 3A to 49 4A 4B to 4E 4F 50 51 52 53 54 55 56 to 64 65 66 to 7F 80 81 82 CD CC 83 20 1D 84 CF C4 85 1C 28 86 to 8F 90 91 to A3 A4 A5 A6 to FF

Remark

Address 00 to 0F 10 11 12 13 14 to 18 19 1A to 21 22 23 24 25 26 27 28 to 29 2A 2B 2C to 35 36 37 38 39 3A 3B to 3C 3D 3E to 44 45 46 47 48 to 55 56 57 58 59 5A to 6E 6F 70 to 7F

Initial value 00

Remark

Fixed data-1 Fixed data-2 Fixed data-1 Fixed data-2 Fixed data-1 Fixed data-2 Fixed data-1 Fixed data-2 Fixed data-1 Fixed data-2 Fixed data-1 Fixed data-2 Fixed data-1 Fixed data-2 (Modified data. Copy the data built in the same model.) Fixed data-1 Fixed data-2 Fixed data-1 Fixed data-2 Fixed data-1 Fixed data-2 Touch panel adj.

Test mode Fixed data-1 Fixed data-2 Fixed data-1 Fixed data-2 Fixed data-1 Fixed data-2 (Modified data. Copy the data built in the same model.)

Fixed data-1 Fixed data-2 Fixed data-1 Fixed data-2 (Modified data. Copy the data built in the same model.) Fixed data-1 Fixed data-2 Fixed data-1 Fixed data-2 Fixed data-1 Fixed data-2 Fixed data-1 Fixed data-2 Fixed data-1 Fixed data-2 (Modified data. Copy the data built in the same model.) Fixed data-1 Fixed data-2 Fixed data-1

Fixed data-1 Fixed data-2 Fixed data-1 Fixed data-2 Fixed data-1

Table. 6-1-2.

Table. 6-1-3.

6-9

DCR-HC16E/HC18E/HC20/HC20E

1-2-2. INITIALIZATION OF 8, C, 1C PAGE DATA Note: When reading or writing the 8, C page data, select page: 0, address: 10, and set data: 00. When reading or writing the 1C page data, select page: 0, address: 10, and set data: 01, then select C page. The 1C page can be chosen by this data setting. After reading or writing, reset the data of page: 0, address: 10 to "00". 1. Initializing the 8, C, 1C Page Data
Note1: If "Initializing the 8, C, 1C Page Data" is performed, all data of the 8 page, C page and 1C page will be initialized. (It is impossible to initialize a single page.) Note2: If the 8, C, 1C page data has been initialized, following adjustments need to be performed again. 1) Modification of 8, C, 1C page data 2) Viewfinder system adjustments 3) LCD system adjustments 4) Serial No. input 5) Servo and RF system adjustments 6) Video system adjustments

2. Modification of 8, C, 1C Page Data If the 8, C, 1C page data has been initialized, change the data of the "Fixed data-2" address shown in the following table by manual input. Modifying Method: 1) Before changing the data, select page: 0, address: 01, and set data: 01. 2) When changing the 8, C page data, select page: 0, address: 10, and set data: 00. 3) When changing the 1C page data, select page: 0, address: 10, and set data: 01. After completing the modification of 1C page data, reset the data of this address to "00". 4) New data for changing are not shown in the tables because they are different in destination. When changing the data, copy the data built in the same model.
Note: If copy the data built in the different model, the camcorder may not operate.

5)

6) Adjusting page Adjusting Address Adjusting page Adjusting Address Adjusting page Adjusting Address 8 00 to FF C 10 to FF 1C 00 to FF

When changing the data, press the PAUSE button of the adjustment remote commander each time when setting new data to write the data in the non-volatile memory. Check that the data of adjustment addresses is the initial value. If not, change the data to the initial value.

Initializing Method: Order Page Address Data Procedure 1 0 01 01 Set the data. 2 0 10 00 Set the data. 3 3 81 Check that the data is "00". 4 3 80 0C Set the data, and press PAUSE button. 5 3 80 Check that the data changes to "1C". 6 Perform "Modification of 8, C, 1C Page Data".

Processing after Completing Modification of 8, C, 1C Page data Order Page Address Data Procedure 1 0 10 00 Set the data. 2 2 00 29 Set the data. 3 2 01 29 Set the data, and press PAUSE button.

6-10

DCR-HC16E/HC18E/HC20/HC20E

3. 8 Page Table
Note1: The data of page: 0, address: 10 must be "00". Note2: Fixed data-1: Initialized data. (Refer to "1. Initializing the 8, C, 1C Page Data".) Fixed data-2: Modified data. (Refer to "2. Modification of 8, C, 1C Page Data").

4. C Page Table
Note1: The data of page: 0, address: 10 must be "00". Note2: Fixed data-1: Initialized data. (Refer to "1. Initializing the 8, C, 1C Page Data".) Fixed data-2: Modified data. (Refer to "2. Modification of 8, C, 1C Page Data").

Address 00 to 79 7A 7B to 83 84 85 86 87 88 89 8A to 94 95 96 to AB AC B1 B2 B3 B4 B5 B6 B7 B8 B9 BA BB BC to BD BE BF C0 to C2 C3 C4 C5 C6 C7 C8 C9 CA CB CC CD CE to D6 D7 D8 to DF E0 E1 E2 E3 E4 E5 E6 E7 E8 to EF F0 F1 to FF

Remark Fixed data-1 Fixed data-2 Fixed data-1 Fixed data-2 (Modified data. Copy the data built in the same model.)

Fixed data-1 Fixed data-2 Fixed data-1 Fixed data-2 Fixed data-1 Fixed data-2 (Modified data. Copy the data built in the same model.) Fixed data-1 Fixed data-2 Fixed data-1 Fixed data-2 (Modified data. Copy the data built in the same model.) Fixed data-1 Fixed data-2 Fixed data-1 Fixed data-2 (Modified data. Copy the data built in the same model.) Fixed data-1 Fixed data-2 (Modified data. Copy the data built in the same model.)

Fixed data-1 Fixed data-2 Fixed data-1 Fixed data-2 Fixed data-1 Fixed data-2 (Modified data. Copy the data built in the same model.) Fixed data-1 Fixed data-2 Fixed data-1 Fixed data-2 Fixed data-1

Address Initial value NTSC PAL 00 to 0F 10 EE EE 11 00 00 12 00 00 13 00 00 14 to 15 16 E0 E0 17 to 24 25 80 80 26 90 90 27 65 65 28 to 3B 3C 3D 3E 3F 6C 7A 40 90 80 41 42 43 44 45 46 47 29 29 48 to 4B 4C 4D 4E 4F 50 6C 78 51 90 80 52 BC BC 53 54 55 56 7D 7D 57 73 73 58 52 52 59 5A to 5A 5B 5C to 61 62 63 64 to 65 66 67 68 69 to 6A

Remark

Switching position adj.

Fixed data-1 CAP FG duty adj. Fixed data-1 S VIDEO out Y level adj. S VIDEO out Cr level adj. S VIDEO out Cb level adj. Fixed data-1 Fixed data-2 (Modified data. Copy the data built in the same model.) VCO adj. (EVF) Fixed data-1 Fixed data-2 Fixed data-1 Fixed data-2 (Modified data. Copy the data built in the same model.) Contrast adj. (EVF) Fixed data-1 Fixed data-2 (Modified data. Copy the data built in the same model.) VCO adj. (LCD) V COM adj. (LCD) Fixed data-2 Fixed data-1 Fixed data-2 Transmissive mode white balance adj. (LCD) Contrast adj. (LCD) Fixed data-2 Fixed data-1 Fixed data-2 Fixed data-1 Fixed data-2 Fixed data-1 Fixed data-2 (Modified data. Copy the data built in the same model.) Fixed data-1

Table. 6-1-4.

6-11

DCR-HC16E/HC18E/HC20/HC20E
C page Address Initial value NTSC PAL 6B 6C to 74 75 76 to 78 79 7A 7B 7B 7B 7C 6C 6C 7D 7E 7F to A3 A4 A5 to A8 A9 AA AB AC AD to AF B0 B1 B2 B3 B4 B5 B6 to CB CC CD CE CF D0 D1 D2 D3 D4 D5 to DE DF E0 08 08 E1 00 00 E2 46 46 E3 01 01 E4 02 02 E5 00 00 E6 00 00 E7 00 00 E8 to F3 F4 00 00 F5 00 00 F6 00 00 F7 00 00 F8 00 00 F9 00 00 Remark Fixed data-2 Fixed data-1 Fixed data-2 Fixed data-1 Fixed data-2 Reflective mode white balance adj. (LCD) Fixed data-1 Fixed data-2 Fixed data-1 Fixed data-2 Fixed data-1 Fixed data-2 (Modified data. Copy the data built in the same model.) Fixed data-1 Fixed data-2 (Modified data. Copy the data built in the same model.) Address Initial value Remark NTSC PAL FA 00 00 Emergency memory address FB 00 00 (Mechanism section) FC 00 00 FD 00 00 FE 00 00 FF 00 00

Table. 6-1-5.

Fixed data-1 Fixed data-2 (Modified data. Copy the data built in the same model.)

Fixed data-1 Fixed data-2 Serial No. input

Fixed data-1 Emergency memory address (Mechanism section)

6-12

DCR-HC16E/HC18E/HC20/HC20E

5. 1C Page Table
Note1: When reading or writing the 1C page data, select page: 0, address: 10, and set data: 01, then select C page. The 1C page can be chosen by this data setting. After reading or writing, reset the data of page: 0, address: 10 to "00". Note2: Fixed data-1: Initialized data. (Refer to "1. Initializing the 8, C, 1C Page Data".) Fixed data-2: Modified data. (Refer to "2. Modification of 8, C, 1C Page Data").

Address 00 to B2 B3 B4 B5 B6 B7 B8 B9 BA BB BC BD BE BF C0 C1 C2 C3 C4 C5 C6 C7 C8 C9 to FF

Initial value 00 00 00 00 00 80 00 00 00 00 00 00 00 00 00 00 80 00 00 00 00 00

Remark Fixed data-1 Error rate check

Fixed data-1

Table. 6-1-6.

6-13

DCR-HC16E/HC18E/HC20/HC20E

1-2-3.

INITIALIZATION OF E, F, 1F PAGE DATA

Note: When reading or writing the E, F page data, select page: 0, address: 10, and set data: 00. When reading or writing the 1F page data, select page: 0, address: 10, and set data: 01, then select F page. The 1F page can be chosen by this data setting. After reading or writing, reset the data of page: 0, address: 10 to "00".

2. Modification of E, F, 1F Page Data If the E, F, 1F page data has been initialized, change the data of the "Fixed data-2" address shown in the following table by manual input. Modifying Method: 1) Before changing the data, select page: 0, address: 01, and set data: 01. 2) When changing the E, F page data, select page: 0, address: 10, and set data: 00. 3) When changing the 1F page data, select page: 0, address: 10, and set data: 01. After completing the modification of 1F page data, reset the data of this address to "00". 4) New data for changing are not shown in the tables because they are different in destination. When changing the data, copy the data built in the same model.
Note: If copy the data built in the different model, the camcorder may not operate.

1. Initializing the E, F, 1F Page Data
Note1: If "Initializing the E, F, 1F Page Data" is performed, all data of the E page, F page and 1F page will be initialized. (It is impossible to initialize a single page.) Note2: If the E, F, 1F page data has been initialized, following adjustments need to be performed again. 1) Modification of E, F, 1F page data 2) Camera system adjustments

Adjusting page Adjusting Address Adjusting page Adjusting Address Adjusting page Adjusting Address Initializing Method:

E 00 to FF F 10 to FF 1F 00 to FF

5)

6)

When changing the data, press the PAUSE button of the adjustment remote commander each time when setting new data to write the data in the non-volatile memory. Check that the data of adjustment addresses is the initial value. If not, change the data to the initial value.

Processing after Completing Modification of E, F, 1F Page data Order Page Address Data Procedure 1 0 01 01 Set the data. 2 0 10 00 Set the data. 3 6 01 Set the following data, and press PAUSE button. 2D:DCR-HC20 (NTSC) 2F: DCR-HC16E/HC18E/HC20E (PAL) 4 6 03 FF Set the data, and press PAUSE button. 5 6 02 Check that the data changes to "01". 6 6 01 00 Set the data, and press PAUSE button. 7 Perform "Modification of E, F, 1F Page Data". Order Page Address Data Procedure 1 0 10 00 Set the data. 2 2 00 29 Set the data. 3 2 01 29 Set the data, and press PAUSE button. 4 Perform "36MHz Origin Osc. Adjustment" of the camera system adjustment.

6-14

DCR-HC16E/HC18E/HC20/HC20E

3. E Page Table
Note1: The data of page: 0, address: 10 must be "00". Note2: Fixed data-1: Initialized data. (Refer to "1. Initializing the E, F, 1F Page Data".) Fixed data-2: Modified data. (Refer to "2. Modification of E, F, 1F Page Data").

4. F Page Table
Note1: The data of page: 0, address: 10 must be "00". Note2: Fixed data-1: Initialized data. (Refer to "1. Initializing the E, F, 1F Page Data".) Fixed data-2: Modified data. (Refer to "2. Modification of E, F, 1F Page Data").

Address 00 to 14 15 16 17 to 1B 1C 1D 1E to 34 35 36 to 3B 3C 3D to 42 43 44 45 46 47 48 49 4A 4B 4C 4D to 86 87 88 89 8A 8B 8C 8D 8E 8F 90 91 92 to C3 C4 C5 to DA DB DC to FF

Remark Fixed data-1 Fixed data-2 Fixed data-1 Fixed data-2 Fixed data-1 Fixed data-2 Fixed data-1 Fixed data-2 Fixed data-1 Fixed data-2 (Modified data. Copy the data built in the same model.) Address Initial value NTSC PAL 00 to 0F 10 80 80 11 12 61 61 13 43 43 14 11 11 15 20 20 16 02 02 17 E0 E0 18 19 A8 A8 1A 00 00 1B 60 60 1C to 29 2A 1B 1B 2B 00 00 2C 07 07 2D 00 00 2E 0E 0E 2F 00 00 30 0D 0D 31 00 00 32 33 22 22 34 35 27 24 36 to 39 3A 00 00 3B F1 EF 3C to 3D 3E 2B 2C 3F C0 40 40 5A 59 41 00 30 42 to 43 44 1F 1F 45 F6 F6 46 27 27 47 DD DD 48 14 14 49 4B 4B 4A 00 00 4B 00 00 4C 00 00 4D 00 00 4E 22 22 4F 19 19 50 00 00 Remark

36MHz origin osc. adj. Fixed data-1 HALL adj.

Fixed data-1 MAX GAIN adj. LV standard data input Fixed data-1 AWB standard data input

Auto white balance adj.

Fixed data-1 Fixed data-2 (Modified data. Copy the data built in the same model.)

Fixed data-1 Fixed data-2 (Modified data. Copy the data built in the same model.) Fixed data-1 Fixed data-2 Fixed data-1 Fixed data-2 Fixed data-1

Fixed data-1 Color reproduction adj. Fixed data-1 Color reproduction adj. Fixed data-1 Color reproduction adj. Fixed data-1 Auto white balance adj.

Fixed data-1 Flange back adj.

Table. 6-1-7.

6-15

DCR-HC16E/HC18E/HC20/HC20E
F page Address Initial value NTSC PAL 51 75 75 52 04 04 53 00 00 54 00 00 56 to 59 5A FF FF 5B to 8B 8C 8D 8E 8F 90 91 to 94 95 96 97 98 99 9A 9B 9C 9D to 9F A0 A1 A2 A3 A4 A5 A6 A7 to A8 A9 AA AB AC AD AE AF B0 B1 to CB CC CD CE CF D0 D1 D2 D3 to EA EB EC to ED EE EF to F1 F2 F3 Remark Flange back adj. Address Initial value NTSC PAL F4 to F8 F9 FA to FB FC FD to FF Remark Fixed data-1 Fixed data-2 Fixed data-1 Fixed data-2 Fixed data-1

Fixed data-1 Optical axis adj. Fixed data-1 Fixed data-2 (Modified data. Copy the data built in the same model.)

Table. 6-1-8.

Fixed data-1 Fixed data-2 (Modified data. Copy the data built in the same model.) Fixed data-1 Fixed data-2 Fixed data-1 Fixed data-2 Fixed data-1 Fixed data-2 (Modified data. Copy the data built in the same model.) Fixed data-1 Fixed data-2 Fixed data-1 Fixed data-2 Fixed data-1 Fixed data-2 (Modified data. Copy the data built in the same model.)

Fixed data-1 Fixed data-2 (Modified data. Copy the data built in the same model.)

Fixed data-1 Fixed data-2 Fixed data-1 Fixed data-2 Fixed data-1 Fixed data-2

6-16

DCR-HC16E/HC18E/HC20/HC20E

5. 1F Page Table
Note1: When reading or writing the 1F page data, select page: 0, address: 10, and set data: 01, then select F page. The 1F page can be chosen by this data setting. After reading or writing, reset the data of page: 0, address: 10 to "00". Note2: Fixed data-1: Initialized data. (Refer to "1. Initializing the E, F, 1F Page Data".) Fixed data-2: Modified data. (Refer to "2. Modification of E, F, 1F Page Data").

Address 00 to 59 5A 5B 5C 5D A9 to FF

Initial value 00 00 00 00

Remark Fixed data-1 Emergency memory address (Camera section)

Fixed data-1

Table. 6-1-9.

6-17

DCR-HC16E/HC18E/HC20/HC20E

1-3.

CAMERA SYSTEM ADJUSTMENTS

Before perform the camera system adjustments (except for "36MHz Origin Oscillation Adjustment"), check that the specified values of "VIDEO SYSTEM ADJUSTMENTS" are satisfied. And check that the data of page: 0, address: 10 is "00". If not, set data: 00 to this address. 1. 36MHz Origin Oscillation Adjustment (VC-350 board) Set the frequency of the clock for synchronization. If deviated, the synchronization will be disrupted and the color will become inconsistent. Subject Not required Measurement Point Pin qs of IC3001 Measuring Instrument Frequency counter Adjustment Page F Adjustment Address 10 Specified Value f=18000000 ± 90Hz
Note: The data of page: 0, address: 10 must be "00".

2. HALL Adjustment For detecting the position of the lens iris and ND filter, adjust AMP gain and offset. Subject Not required Measurement Point Display data of page 1 (Note1) Measuring Instrument Adjustment remote commander Adjustment Page F Adjustment Address 12 to 17 Specified Value 1 85 to 89 Specified Value 2 15 to 19
Note1: Displayed data of page 1 of the adjustment remote commander. 1 : 00 : XX IRIS display data Note2: The data of page: 0, address: 10 must be "00". Note3: Check that the data of page: 6, address: 02 is "00". If not, to page: 6, address: 01, set data: 00, and press the PAUSE button.

Adjusting method: Order Page Address Data Procedure 1 0 01 01 Set the data. 2 F 10 Change the data and set the frequency (f) to the specified value. 3 F 10 Press PAUSE button. 4 0 01 00 Set the data.

Adjusting method: Order Page Address Data Procedure 1 0 01 01 Set the data. 2 6 94 87 Set the data. 3 6 95 17 Set the data. 4 6 01 6D Set the data, and press PAUSE button. 5 6 02 Check that the data changes to "01". (Note4) 6 6 01 00 Set the data, and press PAUSE button.
Note4: The adjustment data will be automatically input to page: F, address: 12 to 17.

36 37 IC3001 48 1

25 24 13 12

VC-350 board

Checking method: Order Page Address Data Procedure 1 0 03 03 Set the data. 2 6 01 01 Set the data, and press PAUSE button. 3 1 Check that the IRIS display data (Note1) satisfies the specified value 1. 4 6 01 03 Set the data, and press PAUSE button. 5 1 Check that the IRIS display data (Note1) satisfies the specified value 2. Processing after Completing Adjustments: Order Page Address Data Procedure 1 6 94 00 Set the data. 2 6 95 00 Set the data. 3 6 01 00 Set the data, and press PAUSE button. 4 0 03 00 Set the data. 5 0 01 00 Set the data.

Fig. 6-1-6.

6-18

DCR-HC16E/HC18E/HC20/HC20E

3. Flange Back Adjustment (Using Minipattern Box) The inner focus lens flange back adjustment is carried out automatically. In whichever case, the focus will be deviated during auto focusing/manual focusing. Subject Siemens star chart with ND filter for the minipattern box (Note1) Measuring Instrument Adjustment remote commander Adjustment Page F Adjustment Address 44 to 54
Note1: Dark Siemens star chart. Note2: This adjustment should be carried out upon completion of "HALL Adjustment". Note3: Make the lens horizontal and perform this adjustment. Note4: The data of page: 0, address: 10 must be "00". Note5: Check that the data of page: 6, address: 02 is "00". If not, turn off the power and turn on again.

Adjusting method: Order Page Address Data Procedure 1 0 01 01 Set the data. 2 6 48 01 Set the data. 3 6 01 13 Set the data, and press PAUSE button. (Note3) 4 5 6 6 01 02 27 Set the data, and press PAUSE button. Check that the data changes to "01". (Note6)

Note6: The adjustment data will be automatically input to page: F, address: 44 to 54.

Switch setting: 1) MODE .................................................................... CAMERA 2) NIGHT SHOT .................................................................. OFF Preparations: 1) The minipattern box is installed as shown in the following figure.
Note: The attachment lenses are not used.

2) 3) 4) 5)

Install the minipattern box so that the distance between it and the front of the lens of the camcorder is less than 3cm. Make the height of the minipattern box and the camcorder equal. Check that the output voltage of the regulated power supply is the specified voltage. Check that at both the zoom lens TELE end and WIDE end, the center of the Siemens star chart and center of the exposure screen coincide.

Processing after Completing Adjustments: Order Page Address Data Procedure 1 6 48 00 Set the data. 2 6 01 00 Set the data, and press PAUSE button. 3 6 01 25 Set the data, and press PAUSE button. 4 6 01 00 Set the data, and press PAUSE button. 5 0 01 00 Set the data. 6 Perform "Flange Back Check".

Specified voltage: The specified voltage varies according to the minipattern box, so adjust the power supply output voltage to the specified voltage written on the sheet which is supplied with the minipattern box.
Below 3 cm Minipattern box Camcorder Camera table Regulated power supply Output voltage : Specified voltage ±0.01Vdc Output current : more than 3.5A

Red (+) Black (­) Yellow (SENS +) White (SENS ­) Black (GND) Need not connected

Fig. 6-1-7.

6-19

DCR-HC16E/HC18E/HC20/HC20E

4. Flange Back Adjustment (Using Flange Back Adjustment Chart and Subject More Than 500m Away) The inner focus lens flange back adjustment is carried out automatically. In whichever case, the focus will be deviated during auto focusing/manual focusing. 4-1. Flange Back Adjustment (1) Subject Flange back adjustment chart (2.0 m from the front of the protection glass) (Luminance: 350 ± 50 lux) Measuring Instrument Adjustment remote commander Adjustment Page F Adjustment Address 44 to 54
Note1: This adjustment should be carried out upon completion of "HALL Adjustment". Note2: Make the lens horizontal and perform this adjustment. Note3: The data of page: 0, address: 10 must be "00". Note4: Check that the data of page: 6, address: 02 is "00". If not, turn off the power and turn on again.

4-2. Flange Back Adjustment (2) Perform this adjustment after performing "Flange Back Adjustment (1)". Subject Subject more than 500m away (Subjects with clear contrast such as buildings, etc.) Measurement Point Check operation on TV monitor Measuring Instrument Adjustment Page F Adjustment Address 44 to 54
Note1: Make the lens horizontal and perform this adjustment. Note2: The data of page: 0, address: 10 must be "00". Note3: Check that the data of page: 6, address: 02 is "00". If not, turn off the power and turn on again.

Switch setting: 1) MODE .................................................................... CAMERA 2) NIGHT SHOT .................................................................. OFF Preparations: 1) Check that at both the zoom lens TELE end and WIDE end, the center of the chart for the flange back adjustment and center of the exposure screen coincide. Adjusting method: Order Page Address Data Procedure 1 0 01 01 Set the data. 2 6 48 01 Set the data. 3 6 01 13 Set the data, and press PAUSE button. (Note2) 4 6 01 15 Set the data, and press PAUSE button. 5 6 02 Check that the data changes to "01". (Note5)
Note5: The adjustment data will be automatically input to page: F, address: 44 to 54.

Switch setting: 1) MODE .................................................................... CAMERA 2) NIGHT SHOT .................................................................. OFF Preparations: 1) Set the zoom lens to the TELE end and expose a subject that is more than 500m away (subject with clear contrast such as building, etc.). (Nearby subjects less than 500m away should not be in the screen.) Adjusting method: Order Page Address Data Procedure 1 0 01 01 Set the data. 2 6 48 01 Set the data. 3 6 01 13 Set the data, and press PAUSE button. (Note2) 4 Place a ND filter on the lens so that the optimum image is obtain. 5 6 01 29 Set the data, and press PAUSE button. 6 6 02 Check that the data changes to "01". (Note4)
Note4: The adjustment data will be automatically input to page: F, address: 44 to 54.

Processing after Completing Adjustments: Order Page Address Data Procedure 1 6 01 00 Set the data, and press PAUSE button. 2 6 01 25 Set the data, and press PAUSE button. 3 6 01 00 Set the data, and press PAUSE button. 4 Perform "Flange Back Adjustment (2)".

Processing after Completing Adjustments: Order Page Address Data Procedure 1 6 48 00 Set the data. 2 6 01 00 Set the data, and press PAUSE button. 3 6 01 25 Set the data, and press PAUSE button. 4 6 01 00 Set the data, and press PAUSE button. 5 0 01 00 Set the data. 6 Perform "Flange Back Check".

6-20

DCR-HC16E/HC18E/HC20/HC20E

5. Flange Back Check Subject Siemens star (2.0m from the front of the lens) (Luminance : approx. 200 lux) Measurement Point Check operation on TV monitor Measuring Instrument Specified Value Focused at the TELE end and WIDE end.
Note1: The data of page: 0, address: 10 must be "00".

Switch setting: 1) MODE .................................................................... CAMERA 2) NIGHT SHOT .................................................................. OFF
Note2: When the auto focus is ON, the lens can be checked if it is focused or not by observing the data on the page 1 of the adjustment remote commander. 1) Select page: 0, address: 03, and set data: 0F. 2) Page 1 shows the state of the focus. 1 : 00 : XX Odd: Focused Even: Unfocused

Checking method: 1) Select page: 6, address: 40, and set data: 01. 2) Select page: 6, address: 41, and set data: 01. 3) Place the Siemens star 2.0m from the front of the lens. 4) To open the IRIS, decrease the luminous intensity to the Siemens star up to a point before noise appear on the image. 5) Shoot the Siemens star with the zoom TELE end. 6) Turn on the auto focus. 7) Check that the lens is focused (Note2). 8) Select page: 6, address: 21, and set data: 10. 9) Shoot the Siemens star with the zoom WIDE end. 10) Observe the TV monitor and check that the lens is focused. Processing after Completing Adjustments: 1) Select page: 6, address: 21, and set data: 00. 2) Select page: 6, address: 40, and set data: 00. 3) Select page: 6, address: 41, and set data: 00. 4) Select page: 0, address: 03, and set data: 00.

6-21

DCR-HC16E/HC18E/HC20/HC20E

6. Optical Axis Adjustment Align the lens Optical Axis with that of the CCD imager. If deviated, center of picture can lose focus when zoom is operated from the WIDE end to the TELE end. Subject Siemens star Measurement Point Check on the monitor TV Measuring Instrument Adjustment Page F Adjustment Address 5A
Note1: This adjustment should be carried out upon completion of "Flange back adjustment". Note2: The data of page: 0, address: 10 must be "00". Note3: Check that the data of page: 6, address: 48 is "00". If not, set data: 00 to this address. Note4: NTSC model : DCR-HC20 PAL model : DCR-HC16E/HC18E/HC20E

Area 1 2 3 4 5 6 7 8

Display phase 22.6° to 67.5° 67.6° to 112.5° 112.6° to 157.5° 157.6° to 202.5° 202.6°to 247.5° 247.6° to 292.5° 292.6° to 337.5° 337.6° to 22.5°

Switch setting: 1) MODE .................................................................... CAMERA 2) DIGITAL ZOOM (Menu setting) .................................... OFF 3) STEADY SHOT (Menu setting) ...................................... OFF Preparations before adjustments: 1) Playback the monoscope segment of the system check tape (XH5-5(NTSC), XH5-5P(PAL),). 2) Attach the optical axis frame chart (transparent) on the monitor TV screen. Center of monoscope image and that of optical axis frame must be agree. 3) Set to CAMERA mode. Adjusting method: 1) Select page: 0, address: 01, and set data: 01. 2) Select page: F, address: 5A, set data: 00, and press the PAUSE button. 3) Place the Siemens star 2.0 m away from the front of the lens. 4) Shoot the Siemens star with the zoom TELE end. 5) Point the lens toward the Siemens star chart until center of the Siemens star is located in the center of the optical axis frame. 6) Shoot the Siemens star with the zoom WIDE end. 7) Measure on the monitor TV screen in which area of the optical axis frame the center of the Siemens star is located. Measure the amount of displacement (distance between the center of the Siemens star and the center of the optical axis frame.) The measurement value is named L1. 8) Read the correction data corresponding to the area from Table 6-1-8. 9) Input the correction data to page: F, address: 5A, and press the PAUSE button 10) Shoot the Siemens star with the zoom TELE end. 11) Point the lens toward the Siemens star chart until center of the Siemens star is located in the center of the optical axis frame. 12) Shoot the Siemens star with the zoom WIDE end. 13) Measure the amount of displacement (distance between the center of the Siemens star and the center of the optical axis frame.) The measurement value is named L2. 14) Compare the values L1 and L2, and confirm that L2 is smaller than L1. If L2 is lager than L1, select page: F, address: 5A, set data: 00, and press the PAUSE button.

Correction data (Page: F, address: 5A) 01 02 03 04 05 06 07 08

Table 6-1-10.
Processing after Completing Adjustments: 1) Select page: 0, address: 01, and set data: 00.

Fig. 6-1-8.

6-22

DCR-HC16E/HC18E/HC20/HC20E

7. Picture Frame Setting Subject Color bar chart (Color reproduction adjustment frame) (1.0m from the front of the lens) Measurement Point Video terminal of AUDIO/VIDEO jack Measuring Instrument Oscilloscope and TV monitor Specified Value A=B, C=D, E=F
Note1: The following adjustments should be carried out upon completion of "Flange back adjustment" and "Optical Axis Adjustment". Note2: The data of page: 0, address: 10 must be "00".

Switch setting: 1) MODE .................................................................... CAMERA 2) NIGHT SHOT .................................................................. OFF 3) DIGITAL ZOOM (Menu setting) .................................... OFF 4) STEADY SHOT (Menu setting) ...................................... OFF Setting method: 1) Select page: 6, address: 48, and set data: 02. 2) Adjust the zoom and the camera direction, and set to the specified position. 3) Mark the position of the picture frame on the monitor display, and adjust the picture frame to this position in following adjustments using "Color reproduction adjustment frame". Processing after Completing Camera System Adjustments: After completing the camera system adjustments, release the data settings. 1) Select page: 6, address: 48, and set data: 00.

Check on the oscilloscope 1. Horizontal period
A=B B A C=D C D

Fig. 6-1-9. 2. Vertical period
E E=F F

V

Fig. 6-1-10. Check on the monitor TV (Underscanned mode)

Color bar chart picture frame

Monitor TV picture frame

Fig. 6-1-11.

6-23

DCR-HC16E/HC18E/HC20/HC20E

8. Color Reproduction Adjustment Adjust the color Separation matrix coefficient so that proper color reproduction is produced. Subject Color bar chart (Color reproduction adjustment frame) Measurement Point Video terminal of AUDIO/VIDEO jack Measuring Instrument Vectorscope Adjustment Page F Adjustment Address 33, 35, 3A, 3B Specified Value All color luminance points should settle within each color reproduction frame.
Note1: This adjustment should be carried out upon completion of "Flange back adjustment" and "Optical Axis Adjustment". Note2: The data of page: 0, address: 10 must be "00". Note3: NTSC model : DCR-HC20 PAL model : DCR-HC16E/HC18E/HC20E

For NTSC model

Switch setting: 1) MODE .................................................................... CAMERA 2) NIGHT SHOT .................................................................. OFF 3) DIGITAL ZOOM (Menu setting) .................................... OFF 4) STEADY SHOT (Menu setting) ...................................... OFF Adjusting method: 1) Select page: 0, address: 01, and set data: 01. 2) Select page: 6, address: 48, and set data: 02. 3) Select page: 6, address: 9D, set the following data, and press the PAUSE button. 7D (NTSC), 82 (PAL) 4) Select page: 6, address: 01, set data: 3D, and press the PAUSE button. 5) Select page: F, address: 80, set the following data, and press the PAUSE button. 37 (NTSC), B7 (PAL) 6) Adjust the GAIN and PHASE of the vectorscope, and adjust the burst luminance point to the burst position of the color reproduction frame. 7) Change the data of page: F, address: 33, 35, 3A and 3B, and settle each color luminance point in each color reproduction frame.
Note: Be sure to press the PAUSE button of the adjustment remote commander before changing the addresses. If not, the new data will not be written to the memory.

Burst position

For PAL model Burst position

Processing after Completing Adjustments: 1) Select page: 6, address: 01, set data: 00, and press the PAUSE button. 2) Select page: 6, address: 48, and set data: 00. 3) Select page: 6, address: 9D, and set data: 00. 4) Select page: 0, address: 01, and set data: 00.

Fig. 6-1-12.

6-24

DCR-HC16E/HC18E/HC20/HC20E

9. MAX GAIN Adjustment Setting the minimum illumination. If it is not consistent, the image level required for taking subjects in low illuminance will not be produced (dark). Subject Clear chart (Color reproduction adjustment frame) Adjustment Page F Adjustment Address 19
Note1: This adjustment should be carried out upon completion of "Flange back adjustment" and "Optical Axis Adjustment". Note2: The data of page: 0, address: 10 must be "00". Note3: Check that the data of page: 6, address: 02 is "00". If not, to page: 6, address: 01, set data: 00, and press the PAUSE button. Note4: NTSC model : DCR-HC20 PAL model : DCR-HC16E/HC18E/HC20E

10. LV Standard Data Input And adjust the normal coefficient of the light value. Subject Clear chart (Color reproduction adjustment frame) Measurement Point Display data of page 1 (Note4) Measuring Instrument Adjustment remote commander Adjustment Page F Adjustment Address 1A, 1B Specified Value 0FB0 to 1050
Note1: This adjustment should be carried out upon completion of "Flange back adjustment", "Optical Axis Adjustment". Note2: The data of page: 0, address: 10 must be "00". Note3: Check that the data of page: 6, address: 02 is "00". If not, to page: 6, address: 01, set data: 00, and press the PAUSE button. Note4: Displayed data of page 1 of the adjustment remote commander. 1 : XX : XX Display data

Switch setting: 1) MODE .................................................................... CAMERA 2) NIGHT SHOT .................................................................. OFF 3) DIGITAL ZOOM (Menu setting) .................................... OFF 4) STEADY SHOT (Menu setting) ...................................... OFF Adjusting method: Order Page Address Data Procedure 1 0 01 01 Set the data. 2 6 48 02 Set the data. 3 6 96 Set the following data. 1F (NTSC), 15(PAL) 4 6 97 00 Set the data. 5 6 01 6F Set the data, and press PAUSE button. 6 6 02 Check that the data changes to "01". (Note5)
Note5: The adjustment data will be automatically input to page: F, address: 19.

Switch setting: 1) MODE .................................................................... CAMERA 2) NIGHT SHOT .................................................................. OFF 3) DIGITAL ZOOM (Menu setting) .................................... OFF 4) STEADY SHOT (Menu setting) ...................................... OFF Adjusting method: Order Page Address Data Procedure 1 0 01 01 Set the data. 2 6 48 02 Set the data. 3 6 01 0D Set the data, and press PAUSE button. 4 6 02 Check that the data changes to "01". (Note5) 5 0 03 1E Set the data. 6 1 Check that the display data (Note5) satisfies the specified value.
Note5: The adjustment data will be automatically input to page: F, address: 1A, 1B.

Processing after Completing Adjustments Order Page Address Data Procedure 1 6 48 00 Set the data. 2 6 96 00 Set the data. 3 6 97 00 Set the data. 4 6 01 00 Set the data, and press PAUSE button. 5 0 01 00 Set the data.

Processing after Completing Adjustments Order Page Address Data Procedure 1 6 01 00 Set the data, and press PAUSE button. 2 6 48 00 Set the data. 3 0 03 00 Set the data. 4 0 01 00 Set the data. 5 Perform "Auto White Balance Standard Data Input".

6-25

DCR-HC16E/HC18E/HC20/HC20E

11. Auto White Balance Standard Data Input Adjust the white balance reference at 3200K. Subject Clear chart (Color reproduction adjustment frame) Adjustment Page F Adjustment Address 2A to 2D
Note1: This adjustment should be carried out upon completion of "Flange back adjustment", "Optical Axis Adjustment" and "Color reproduction adjustment". Note2: The data of page: 0, address: 10 must be "00". Note3: Check that the data of page: 6, address: 02 is "00". If not, to page: 6, address: 01, set data: 00, and press the PAUSE button.

12. Auto White Balance Adjustment Adjust to the proper auto white balance output data. If it is not correct, auto white balance and color reproducibility will be poor. Subject Filter Adjustment Page Adjustment Address Clear chart (Color reproduction adjustment frame) Filter C14 for color temperature correction F 2E to 31, 3E to 41

Switch setting: 1) MODE .................................................................... CAMERA 2) NIGHT SHOT .................................................................. OFF 3) DIGITAL ZOOM (Menu setting) .................................... OFF 4) STEADY SHOT (Menu setting) ...................................... OFF Adjusting method: Order Page Address Data Procedure 1 0 01 01 Set the data. 2 6 48 02 Set the data. 3 Wait for 2 sec. 4 6 01 11 Set the data, and press PAUSE button. 5 6 01 0B Set the data, and press PAUSE button. 6 6 02 Check that the data changes to "01". (Note4)
Note4: The adjustment data will be automatically input to page: F, address: 2A to 2D.

Note1: This adjustment should be carried out upon completion of "Auto White Balance Standard Data Input". Note2: The data of page: 0, address: 10 must be "00". Note3: Check that the data of page: 6, address: 02 is "00". If not, to page: 6, address: 01, set data: 00, and press the PAUSE button. Note4: NTSC model : DCR-HC20 PAL model : DCR-HC16E/HC18E/HC20E

Switch setting: 1) MODE .................................................................... CAMERA 2) NIGHT SHOT .................................................................. OFF 3) DIGITAL ZOOM (Menu setting) .................................... OFF 4) STEADY SHOT (Menu setting) ...................................... OFF Adjusting method: Order Page Address Data Procedure 1 Place the C14 filter for color temperature correction on the lens. 2 0 01 01 Set the data. 3 6 48 02 Set the data. 4 F 3E 2A Set the data, and press PAUSE button. 5 F 3F Set the following data, and press PAUSE button. 00 (NTSC), C0 (PAL) 6 F 40 Set the following data, and press PAUSE button. 5D (NTSC), 5C (PAL) 7 F 41 00 Set the data, and press PAUSE button. 8 6 01 83 Set the data, and press PAUSE button. 9 6 01 81 Set the data, and press PAUSE button. 10 6 02 Check that the data changes to "01". (Note5)
Note5: The adjustment data will be automatically input to page: F, address: 2E to 31.

Processing after Completing Adjustments Order Page Address Data Procedure 1 6 01 00 Set the data, and press PAUSE button. 2 6 48 00 Set the data. 3 0 01 00 Set the data. 4 Perform "Auto White Balance Adjustment".

Processing after Completing Adjustments: Order Page Address Data Procedure 1 6 01 00 Set the data, and press PAUSE button. 2 6 48 00 Set the data. 3 0 01 00 Set the data. 4 Perform "White Balance Check".

6-26

DCR-HC16E/HC18E/HC20/HC20E

13. White Balance Check Subject Clear chart (Color reproduction adjustment frame) Filter Filter C14 for color temperature correction ND filter 1.0 and 0.4 and 0.1 Measurement Point Video terminal of Display data AUDIO/VIDEO of page 1 (Note3) jack Measuring Instrument Vectorscope Adjustment remote commander Specified Value 1 Fig. 6-1-13. A to B Specified Value 2 R ratio : 29C0 to 2A40 (NTSC) 2A80 to 2B00 (PAL) B ratio : 5CC0 to 5D40 (NTSC) 5BC0 to 5C40 (PAL) Specified Value 3 8000 to 8BC0
Note1: Perform "Auto White Balance Adjustment" before this adjustment. If not performed, R ratio data and B ratio data may not satisfy the specified value 2. Note2: The data of page: 0, address: 10 must be "00". Note3: Displayed data of the adjustment remote commander. 1 : XX : XX Display data Note4: NTSC model : DCR-HC20 PAL model : DCR-HC16E/HC18E/HC20E

Checking method: Order Page Address Data 1 2 3 4 6 6 48 01 02 0F Procedure Indoor white balance check Check that the lens is not covered with either filter. Set the data. Set the data, and press PAUSE button. Check that the center of the white luminance point is within the circle shown Fig. 6-1-13. A. Set the data, and press PAUSE button. Outdoor white balance check Place the C14 filter on the lens. Set the data, and press PAUSE button. Check that the center of the white luminance point is within the circle shown Fig. 6-1-13. B. Set the data. Check that the display data (Note3) satisfies the R ratio specified value. Set the data. Check that the display data (Note3) satisfies the B ratio specified value. Remove the C14 filter. LV data check Place the ND filter 1.5 (1.0+0.1+0.4) on the lens. Set the data, and press PAUSE button. Set the data. Check that the display data (Note3) satisfies the specified value 3.

5

6

01

00

6 7 8

6

01

3F

9 10

0 1

03

04

Switch setting: 1) MODE .................................................................... CAMERA 2) NIGHT SHOT .................................................................. OFF 3) DIGITAL ZOOM (Menu setting) .................................... OFF 4) STEADY SHOT (Menu setting) ...................................... OFF

11 12

0 1

03

05

13 14

R-Y

2mm

15 16 17

6 0 1

01 03

00 06

B-Y

2mm

Fig. 6-1-13 (A).

1mm 0.5mm

R-Y

Processing after Completing Adjustments Order Page Address Data Procedure 1 0 03 00 Set the data. 2 6 01 00 Set the data, and press PAUSE button. 3 Remove the ND filter.
B-Y 3mm

3mm

Fig. 6-1-13 (B).

6-27

DCR-HC16E/HC18E/HC20/HC20E

14. Steady Shot Check Precautions on the Parts Replacement There are two types of repair parts. Type A : ENC03MA Type B : ENC03MB Replace the broken sensor with a same type sensor. If replace with other type parts, the image will vibrate up and down or left and right during hand-shake correction operations. Precautions on Angular Velocity Sensor The sensor incorporates a precision oscillator. Handle it with care as if it dropped, the balance of the oscillator will be disrupted and operations will not be performed properly. Subject Measurement Point Measuring Instrument Specified Value Arbitrary Display data of page 1 (Note1) Adjustment remote commander 2680 to 5080

Note1: Displayed data of the adjustment remote commander. 1 : XX : XX Display data Note2: The data of page: 0, address: 10 must be "00".

Switch setting: 1) STEADY SHOT (CAMERA SET menu) ......................... ON 2) ZOOM .................................................................... TELE end Adjusting method: Order Page Address Data

1 2

0 1

03

11

3 4

0 1

03

12

5 6

0

03

00

Procedure Pitch sensor check (SE-141 board SE401) Set the data. Check that the display data (Note1) satisfies the specified value. (Note3) Yaw sensor check (SE-141 board SE402) Set the data. Check that the display data (Note1) satisfies the specified value. (Note3) Set the data. Move the camcorder, and check that the steady shot operations have been performed normally

Note3: Don't move the camcorder.

6-28

DCR-HC16E/HC18E/HC20/HC20E

1-4.

ELECTRONIC VIEWFINDER SYSTEM ADJUSTMENT

Note1: When replacing the LCD unit, be careful to prevent damages caused by static electricity. Note2: Be