CONTROL MODULE EPM1 ­ FAILURES LIST
F1 F2 F3 F4 F6 F8 Meat probe defect (short circuit) during use ­ check or replace connections or meat probe. Error in the measurement circuit ­ replace module Error in the measurement circuit ­ replace module PT1000 defect (short circuit or not connected) (normal resistance at room temperature should
be around 1000ohm) ­ replace sensor

Relay uncontrollable ­ check flat cable connection between modules, try with new relay module. Over Temperature (>310°C) in the Oven measured ­ check for the reason that heaters are
not disconnected (measuring circuit, relays module, ..)

F10

Error of power supply (Relay board defect or connection between Relay board and Display board not correct) Temperature sensor of the ambient temperature defect ­ check for the bad connections on ambient temperature sensor, if OK replace module Main failure was happen ­ check relay module & power supply Defect in the circuit for touch sensor ­ check sensors, replace module if needed Error in the Touch Sensor circuit of the Keyboard, * advises which key (number) ­ see previous ambient temperature too high (> 85°C) ­ temperature around electronic module is higher than 85 deg.C. Check for the reason in malfunction in cooling ventilator operation or other source of abnormal heat.

F15

F16 F18 F2*

F85