Text preview for : 321 region code change.pdf part of Bose 321 Bose 321 Region Code change manual
Back to : 321 region code change.pd | Home
APPENDIX
Computer Setup Procedure Use this procedure to set up your IBM compatible PC for communication with the 3-2-1 system console.
1. Open a terminal window, as shown at right, in either Terminal or Hyperterm, as applicable for the version of Microsoft® Windows® you are using on your PC.
2. In the terminal window, click on FILE, then PROPERTIES. Set the Test Properties in the dialog box as shown at right.
3. In the Test Properties dialog box shown in step 2, click on CONFIGURE to set the COM1 Properties as shown at right. Click OK to return to the Test Properties dialog box. See the next page for the conclusion of this setup procedure.
APPENDIX
Computer Setup Procedure (continued) 4. In the Test Properties dialog box, click on the SETTINGS tab and set the controls as shown in the example at right. Note: Be sure to check "Beep three times when connecting or disconnecting".
5. In the Test Properties dialog box under the SETTINGS tab, click on the ASCII Setup button and set the controls to look like the example at right. Click OK to return to the Test Properties dialog box.
6. Once you have made all of the settings in the Test Properties dialog box, click OK to close it. You have now configured your PC to communicate with the 3-2-1 system console. To connect to the console under test, in the terminal window, click on CALL, then CONNECT and listen for 3 beeps. This will tell you that the PC is connected to communicate with the console. When you have completed your session, click on CALL, then DISCONNECT to end communication with the console.
APPENDIX
TAP Cable Fabrication Instructions Note: In order to use the Test Access Port (TAP) commands listed in this service manual, it is necessary to construct a dedicated cable for this purpose. Refer to the part list and instructions below. Note: Refer to Figure x below for the following instructions. Parts needed: 1 - IBM compatible PC null modem cable (9 pin female connector each end) 1 - JST 3 pin connector, JST model ZHR-3. 1 - Red wire with JST terminal, Bose® part number 177426-11 1 - White wire with JST terminal, Bose part number 177426-12 1 - Green wire with JST terminal, Bose part number 177426-8 1 - B+B Electronics RS-232 to TTL converter, B+B model number 232LPTTL (available at the B+B Electronics web site at http://www.bb-elec.com) 1. Cut off one end of the PC null modem cable. You will need only the three wires that correspond to pin 2, pin 3 and pin 5 of the 9 pin D-SUB connector. 2. Mount the three wires with the pre-crimped JST terminals into the JST connector as shown in Figure x. The red wire goes to pin 1, the white to pin 2 and the green to pin 3. Be sure to check that the wire locations are correct or your cable will not work. 3. Once the wires are installed, place a piece of heat shrink tubing over the three wires approximately 1/8" behind the JST connector and heat shrink it in place. This is to help keep the wires secured in the connector. Now place a two inch long piece of heat shrink tubing over the other piece and just over the shoulder of the JST connector. Heat shrink this in place as well. This tubing will provide a convenient means of cable insertion and removal in the 3-2-1 console connector. Changing the 3-2-1 Console Region Code Note: You can only change the region code for a console a total of 4 times. After that the console will not change the region code. 1. Connect the B+B RS-232 to TTL converter to one of the serial data ports on the back of your IBM compatible PC. Connect the TAP interface cable to the B+B converter. Plug the other end of the cable into J1 of the 3-2-1 console display board. This connector can be accessed from outside the cabinet, under the right side of the front of the console.
1
JST connector P/N: ZHR-3
2
3
Red wire, P/N: 177426-11
White wire, P/N: 177426-12 Green wire, P/N: 177426-8 Splice Point
Wire to pin 5 of 9 pin D-sub
Wire to pin 2 of 9 pin D-sub Wire to pin 3 of 9 pin D-sub
1
2
3
JST connector end view
IBM PC 9-pin null modem cable
Figure x. Tap Interface cable wiring diagram
APPENDIX
Changing the 3-2-1 Console Region Code (continued) 2. Set up your computer as shown in the computer setup procedure earlier in this manual. 3. Power up the 3-2-1 system console. On the PC, open the terminal window that you have set up using the computer setup procedure. Open the connection between the PC and the console. 4. On the console, place a DVD disc of the region that you want to change to into the console tray. For example, if you wanted to change a region code 1 console to region 2, you would place a region code 2 DVD disc into the console. Allow the disc to spin up. 5. On the PC, type in the applicable TAP command from the table below and press ENTER on the keyboard. The region code will have changed to the new region.
Regions Covered U.S., Canada, Puerto Rico Europe, Middle East, Japan Southeast Asia, Hong Kong, Taiwan Central America, Mexico, South America, Australia, New Zealand Russia, Africa (except Egypt and South Africa), India, Pakistan China
Region Code 1 2 3 4 5 6
Command LXTP09 LXTP0a LXTP0b LXTP0c LXTP0d LXTP0e