Text preview for : sm27958.pdf part of ariston New Ariston 60 cm platform MBT 2022 Z
Back to : sm27958.pdf | Home
EN
SERVICE MANUAL
NEW ARISTON 60 cm PLATFORM
All the parts included in this document are the property of Indesit Company S.p.A. All rights reserved. This document and all the information contained in it are supplied without responsibility for possible errors or omissions and no part of it can be reproduced, used or removed without written permission or a contractual clause.
Service Manual NEW ARISTON 60 cm PLATFORM
Edition 2006.06.15
Language English
1
EN
Contents of the Manual: Note for the Engineer.
This manual is a supporting document for technical personnel. It contains a description of the various product types, the general operating principles and indications concerning assistance. Technical personnel should, in any case, consult the specific model on (www.servicenet. indesitcompany.com) to access data and updates of electrical diagrams, technical bulletins and spare parts.
Service Manual NEW ARISTON 60 cm PLATFORM
Edition 2006.06.15
Language English
2
EN
CONTENTS
1. PRODUCT TYPE
Legend Interfaces Energy Label
4-6
4 5 6
2. OPERATING LOGIC
Product types Explanation of setting and operation of control knob interfaces Explanation of setting and operation of TOUCH control interfaces Product characteristics Static appliances Full No Frost appliances
7-17
7 8-10 11-14 15 16 17
3. COMPONENTS 4. WIRING DIAGRAMS
Electronic thermostat wiring diagram Full wiring diagram
18 19-22
19-20 21-22
5. ASSISTANCE
Demo Mode Auto Test Faults and Solutions Troubleshooting Dismantling the TOUCH interface
23-25
23 23-26 27-30 31 32-34
6. EXPLODED VIEWS 7. APPENDIXES
Probes Table (Temperature / Resistance)
35-45 46
46
Service Manual NEW ARISTON 60 cm PLATFORM
Edition 2006.06.15
Language English
3
EN
1.1. ARISTON APPLIANCES LEGEND:
M B
M=Ariston B = Combi T = Double Door
T
M = Mechanic L = LED + Ele + Air T = TOUCH + Ele + Air P = BUTTONS + Ele + Air
20 2
15 = 150cm 17 = 175 cm 18 = 187cm 20 = 200cm 3 = A++ 2 = A+ Freezer Temp. 1=A
2
CZ
-
-
-
1 = White C = Chiller Z = Variable 2= Stainless steel I = Integrated Everfresh 3 = Silver V = Ventilated
Q= Aquacare T = Tropical F= No Frost L = Lock S= NF Surround
Service Manual NEW ARISTON 60 cm PLATFORM
Edition 2006.06.15
Language English
PRODUCT TYPE
1. PRODUCT TYPE:
4
EN
Electronic thermostat
Electronic Static Combi - No Frost Basic Legend:
1. SUPER FRIDGE button
2. FRIDGE knob 3. SUPER FRIDGE indicator led 4. Power supply indicator led 5. SUPER FREEZE indicator led 6. SUPER FREEZE button 7. FREEZER knob
2
1
3
4
5
6
7
Interface: Everfresh
Interface: without Everfresh
13
14
13
14
7 4 2 3 8 9 10 11 12 1
Legend:
1. ON/OFF button 2. VARIABLE TEMPERATURE COMPARTMENT temperature selector 3. FREEZER COMPARTMENT temperature selector
7 4 2 3 9 11 12 1
10. 11. 12. 13. 14.
8
6 5
6 5
"EVER FRESH" button "ICE PARTY" button FREEZER display FRIDGE display VARIABLE TEMPERATURE COMPARTMENT display
4. FRIDGE COMPARTMENT temperature button 5. "I CARE" button 6. "HOLIDAY" button 7. "RESET ALARM" button 8. "SUPER FRIDGE" button 9. "SUPER FREEZE" button
Service Manual NEW ARISTON 60 cm PLATFORM
Edition 2006.06.15
Language English
PRODUCT TYPE
1.2. INTERFACE:
5
EN
Energy Label for appliances:
Ariston XXX
Service Manual NEW ARISTON 60 cm PLATFORM
Edition 2006.06.15
Language English
PRODUCT TYPE
1.3. ENERGY LABEL:
6
EN
2. PRODUCT TYPE
2.1 ARISTON DOUBLE DOOR,
ELECTRONIC THERMOSTAT:
2.2 ARISTON COMBI,
ELECTRONIC THERMOSTAT:
OPERATING LOGIC
Consult Indesit New Cold Platform Manual. Operation is identical or similar to equivalent Indesit appliance.
Consult Indesit New Cold Platform Manual. Appliance operation is the same as the Indesit brand appliance.
Service Manual NEW ARISTON 60 cm PLATFORM
Edition 2006.06.15
Language English
7
EN
2.3 APPLIANCES WITH CONTROL KNOB INTERFACE
2.3.1 "FREEZER KNOB" FUNCTIONS:
Switching the appliance ON/OFF:
The freezer knob is used for switching the appliance on/off. In the"OFF" position, the appliance is switched off (Logical Off). Turn the knob clockwise to switch the refrigerator on. To switch it off, turn the knob anti-clockwise to Off (Virtual Off).
Activation/Setting of the C.C.Z. variable temperature compartment (where available) and/or Freezer compartment temperature setting:
In appliances with knob controls, temperature setting of the variable temperature compartment and of the freezer compartment are interdependent, since both are adjusted with the same control knob. The first half of the knob's range activates the
variable temperature compartment (C.C.Z.) and the freezer compartment temperature will be approx. -18°C. For C.C.Z. temperature setting the user has three options: · STRAWBERRY symbol, sets temperature to -8°C. · ICE CREAM symbol, sets temperature to approx. -12°C. · BOTTLE symbol: sets temperature to approx. -18°C. If the knob is set past the half way mark (after the bottle), the C.C.Z. switches off and the relative drawer can be used as an additional standard freezer drawer. To select the lowest temperatures, turn the knob clockwise (past the half-way mark). To select the higher temperatures, turn anti-clockwise (to the section next to the bottle symbol). Note.: to activate the I CARE function, the fridge and freezer knobs must both be set to the I CARE position.
Service Manual NEW ARISTON 60 cm PLATFORM
Edition 2006.06.15
Language English
OPERATING LOGIC
8
EN
2.3.2 FRIDGE COMPARTMENT KNOB:
The fridge compartment knob is used for switching the refrigerator compartment on/off. If the knob is set to OFF, the fridge compartment is switched off. Turn the knob clockwise (away from the OFF position) to switch the fridge compartment on. To switch it off, turn the knob anti-clockwise to the OFF position. To select the lowest temperatures, turn the knob clockwise. Turn anti-clockwise to select the higher temperatures. The refrigerator knob is also used to select the Holiday function (two beeps signal activation, one beep signals deactivation), indicated with a beach umbrella symbol (the function on this platform has the same characteristics as the Indesit New Electronic Cold Platform - Consult manual).
When this function is selected, the fridge compartment will be thermostat-controlled at around 12°C and the freezer compartment will be approx. -18°C. Note.: to activate the I CARE function, the fridge and freezer knobs must both be set to the I CARE position. will flash to indicate that the function has been activated and will continue to flash for the first 24 hours, after which it will remain lit steady for the last 24 hours. This function has the same characteristics as appliances in the Indesit New Electronic Cold Platform (consult manual). The function is deactivated automatically at the end of the 48 hours. On No Frost products, the Super Freeze function can only be set for 24 hours. The function is activated by pressing the relative button and is deactivated automatically when the maximum time has elapsed (24 hours) or once a given temperature has been reached and maintained for a time interval parameterised in the EEPROM memory. With both appliances, the function can be deactivated: by pressing the relative button again or switching off the appliance. In the event of a power failure while the function is activated, when the power is restored the PCB (which controls the function), will reactivate it, completing the remaining hours. In the event of an alarm mode, the function cannot be activated and if already active, the PCB will automatically deactivate it. The Super Freeze function cannot be activated together with the Holiday function.
2.3.3 SUPER FREEZE BUTTON:
The Super Freeze button is used for activating/ deactivating the Super Freeze function for 24 / 48 hours for static appliances and for 24 hours for No Frost appliances. To activate the 24 hour Super freeze function on static appliances, press the relative button, the indicator led will light up steady. This function operates with the same logic as appliances in the Indesit New Electronic Cold Platform (consult manual). The function is deactivated automatically when the maximum time has elapsed (24 hours) or once a given temperature has been reached and maintained for a time interval parameterised in the EEPROM memory. To activate the 48 hour Super freeze function, press and hold the button for 3 seconds. The led
Service Manual NEW ARISTON 60 cm PLATFORM
Edition 2006.06.15
Language English
OPERATING LOGIC
9
EN
2.3.4 SUPER FRIDGE OR EVER FRESH BUTTON (depending on model):
To activate the Super Fridge function, press the relative button, the corresponding Led will light up to signal activation. The function is deactivated automatically upon completion of the cycles parameterised for this function on the PCB. The function can be deactivated: by pressing the relative button again or switching off the refrigerator compartment or appliance. In the event of a power failure while the function is activated, when the power is restored, the PCB (which controls the function), will reactivate it from where it was interrupted. In the event of an alarm mode, the function cannot be activated and if already active, the PCB will automatically deactivate it. The function cannot be activated if the Holiday function is already active.
In other models with control knob interface, where available, this button is also used to activate the Ever Fresh function. For further information on the operation of this function, see chapter PRODUCT CHARACTERISTICS.
2.3.5 LEDs:
The appliances has 3 leds (from left to right): 1. Super Fridge (Ever Fresh) led which lights up when the user activates the Super Fridge function or, on some models (where featured), lights up when the user activates the Ever Fresh function. 2. Appliance Powered led which lights up automatically when the appliance is connected to the power supply. 3. Super Freeze led which lights up steady when the user activates the 24 hour Super Freeze function and flashes when the user activates the 48 hour Super Freeze function (only available on static appliances).
Another function of the Leds is to alert the user and/or technician to any Faults (see Assistance chapter - Fault Table).
Service Manual NEW ARISTON 60 cm PLATFORM
Edition 2006.06.15
Language English
10
OPERATING LOGIC
EN
2.4 APPLIANCES WITH TOUCH INTERFACE:
2.4.1 Switching the appliance ON/OFF: To switch the appliance ON, press the Power ON button. The led changes from red to green and the I CARE function is automatically activated. The display shows the temperatures for the fridge and freezer compartments (+ 5 and -18 respectively) and the AUTO led lights up, the ICE CREAM function of the CCZ. The user can now change/personalise settings. To switch the appliance off, press the power button for two seconds. The corresponding led changes colour (from green to red) and all the control panel leds switch off.
2.4.2 SWITCHING THE FRIDGE COMPARTMENT ON/ OFF:
The fridge compartment switches on automatically when the appliance is switched on (see previous paragraph). The refrigerator compartment can be switched off by then pressing the "-" button, the temperature will reach +2°C, press again and the display will show "- -", indicating that the compartment is switched off. To switch it back on again, press "+", the display will show +2°C, continue pressing the button to obtain the desired temperature.
2.4.3 SETTING FUNCTIONS:
All available functions are highlighted on the control panel with special symbols. To activate a function, simply press the relative button; the corresponding led will light up to indicate that the function has been selected. Those functions having a duration parameterised in the EEPROM memory will end once the exit conditions are met or, when the function button is pressed again.
Service Manual NEW ARISTON 60 cm PLATFORM
Edition 2006.06.15
Language English
11
OPERATING LOGIC
EN
2.4.4 SETTING FRIDGE AND FREEZER TEMPERATURE:
When the appliance is switched on, the I CARE function is automatically activated (see details of I CARE function) and the display shows +5°C for the fridge compartment and -18°C for the freezer compartment. The AUTO led lights up. To change the temperatures simply press the "+" or "-" button next to the relative display (fridge or freezer display) to increase or decrease the temperature of the desired compartment. When the temperature in one of the compartments is changed, the "AUTO" led switches off.
2.4.5 ACTIVATING THE VARIABLE TEMPERATURE COMPARTMENT (C.C.Z.):
When the appliance is switched on, the variable temperature compartment is activated and the display shows the ICE CREAM symbol (-12°C). Press the arrow (left of the symbol) to change the setting and select the desired temperature or to switch off the compartment (in this case, no symbol will remain lit) and use it as simply another freezer drawer. The setting options for this compartment are as follows: a. STRAWBERRY symbol, for a temperature of 8°C. b. ICE CREAM symbol, maintains the C.C.Z. temperature at approx. -12°C and,
3. BOTTLE symbol, for a temperature of approx. -18°C. 4. All leds switch off, which means the compartment operates as a normal freezer drawer.
2.4.6 APPLIANCE SPECIAL FUNCTIONS
HOLIDAY Function:
For details of this function, see the Indesit New Electronic Cold Platform manual. When the Holiday function is active, the Ever Fresh function can be activated, the temperature in the variable temperature compartment can be changed and the child lock can be activated/ deactivated.
ICE PARTY Function:
This function enables the user to chill a bottle (Champagne, wine, ...) in the freezer compartment as quickly as possible. The appliance will force the compressor to run continuously in order to have the maximum refrigerating power and rapidly chill the bottle. After 30 minutes, the time parameterised in the EEPROM for this function, the display and an acoustic signal alert the user to remove the bottle in order to prevent it from breaking. The function is activated by pressing the corresponding function button. The function is deactivated at the end of the set time or by pressing the function button again, after which the appliance will continue with normal operation.
Service Manual NEW ARISTON 60 cm PLATFORM
Edition 2006.06.15
Language English
12
OPERATING LOGIC
EN
Super Freeze Function:
See the Super Freeze function of the Indesit New Electronic Cold Platform (24 hour version for No Frost models and 24/48 hour version for Static models).
Super Fridge Function:
See the Super Fridge function of the Indesit New Electronic Platform.
Child Lock:
The Child Lock function is designed to prevent accidental changes to appliance settings. To activate the function, press and hold the "Alarm" button for two seconds, the display shows "LO CH" and the buzzer emits a short beep. The appliance shows "LO CH" on the display for the time parameterised in the EEPROM memory while the function remains active. The function is deactivated by pressing the "Alarm" button again for two seconds. The buzzer beeps and the message "CH OF" appears on the display, confirming exit from the function. In the event of a temperature alarm, an Ever Fresh or door open alarm, or if the ICE-PARTY function ends or a Fault is detected, these situation take priority, halting and deactivating the Child Lock. When the alarm situation is over, the Child Lock function WILL NOT be reactivated automatically. In the event of a power failure, when power is restored the function will be reactivated automatically.
I CARE:
For appliances with control knob interface, the I CARE function, featured on the Ariston New Electronic Cold Platform, is identical to the ECO function on the Indesit New Electronic Cold Platform. For appliances with TOUCH interface, this function is activated automatically when the appliance is switched on. The Auto led also lights up automatically, only switching off if and when the user changes the preset temperature. If the user changes the temperature and later reverts to the temperatures managed by I CARE manually, the Auto led will not light up again and the PCB will not switch the solenoid valve before switching off the compressor at the end of the cooling demand from the fridge compartment. In short, the appliance will operate as a normal appliance with normal temperature settings. To once again activate function, the user must set the I CARE function by pressing the relative button. The temperature bands can be changed without exiting the I CARE function.
Service Manual NEW ARISTON 60 cm PLATFORM
Edition 2006.06.15
Language English
13
OPERATING LOGIC
At the end of the function, when end of function conditions are met, the appliance emits an acoustic signal and the led starts flashing, alerting the user to remove the bottle. To exit the function, the user must press the button until the function led indicator stops flashing. The function cannot be activated in an alarm condition or in tandem with the HOLIDAY function. Activation of the HOLIDAY function automatically deactivates the ICE PARTY function and activates the corresponding buzzer and led, prompting the user to remove the bottle. The I CARE or SUPER FREEZER functions can be activated but will start at the end of the ICE PARTY function. IMPORTANT: In the event of a power failure during the I CARE function, when the power supply is restored the function will not be reactivated and the end of function signal will be activated immediately.
EN
To do this, hold the function button down and, at the same time, press the temperature change buttons for the desired compartment. The variation options are: Fridge compartment: +4°C, +5°C, +6°C. Freezer compartment: -18°C, -19°C, -20°C.
EVER FRESH (Where available):
This function enables the user to store vacuum packed food for a prolonged period of time. Before pressing the button to select the function, the user must set the ring of the container to "Vacuum empty" and insert the container in the allotted space, pulling the internal button on the shelf and activating Ever Fresh function with the button. When the user activates the function (pressing the function button with the appliance on), the PCB activates a TRIAC which in turn switches on the vacuum pump. The function is deactivated automatically when the PCB receives Feed Back from the vacuum switch indicating that air has been removed from the container, or by pressing the Ever Fresh button again or switching off the fridge compartment (only for appliances with control knobs) or the entire appliance. In the event the vacuum pump continues running, for a period of time established as the maximum parameter, the pump will be deactivated and the function will enter alarm mode. In appliances with Led interface, when in alarm mode the relative Led will flash and the buzzer will beep twice. In appliances with TOUCH interface the Led will change colour (from blue to red), it will also start flashing and the buzzer will beep twice. In both cases, to reset the alarm simply press the Ever Fresh button. Note.: entering alarm mode automatically results in deactivation of the function. This function does not interact with other appliance functions and cannot be activated when the appliance is switched off. OPERATING LOGIC
Edition 2006.06.15 Language English
Service Manual NEW ARISTON 60 cm PLATFORM
14
EN
2.5 PRODUCT CHARACTERISTICS:
SURROUND:
The innovative SURROUND refrigeration system featured on all Ariston Full No Frost refrigerators guarantees a uniform temperature throughout the refrigeration compartment thanks to numerous ventilation cells. It is easy to identify since inside the fridge an extension of the multiflow which reaches to the very roof of the compartment is clearly visible. The Surround system It is managed by the appliance's main PCB which controls a stepper type electronic damper with three positions:
a. Closed: when there is no cooling demand from the fridge compartment. In this case there is no air circulation inside the compartment. b. Open 45°: which allows circulation of air through the multiflow column. This grading occurs when the user selects any function other than I CARE or Super Fridge, and therefore, the SURROUND system is not activated. c. Open 90°: In this case the SURROUND system is active and the four vents are operational (with air flow). The electronic circuit board will open the Damper at 90°. The SURROUND system will be activated by the PCB automatically if the user has set the I CARE and/or Super Fridge function on the control panel.
Control Care Zone (C.C.Z.):
-12°C represented by the ICE CREAM and, -18°C represented by a BOTTLE. Note.: with C.C.Z. switched off, the drawer in question operates as a normal freezer compartment drawer, both in Static and No Frost appliances.
The Control Care Zone (C.C.Z.) or variable temperature compartment is an area of the freezer (top drawer) which allows the user to set a different temperature compared to the rest of the freezer compartment (which will operate as a normal freezer). The setting options are: -8°C represented by the STRAWBERRY symbol,
Service Manual NEW ARISTON 60 cm PLATFORM
Edition 2006.06.15
Language English
15
OPERATING LOGIC
EN
2.6 STATIC APPLIANCES:
To introduce this technology in static appliances, the following thermodynamic changes had to be made: There are two solenoid valves instead of one, physically positioned in "series" (cascade connection), and three capillary tubes as opposed to two; all electronically controlled as follows: E.V.1-ON / E.V.2-Off (Capillary 1): The gas is sent first to the fridge evaporator and then to the freezer evaporator, as in traditional models. E.V.1-Off / E.V.2-Off (Capillary 2): Here the gas is sent only to the freezer compartment (not to the CCZ). E.V.1-Off / E.V.2-On (Capillary 3): In this case, the gas is sent first to the variable temperature compartment and then to the freezer compartment.
2 flags
EV2
OPERATING LOGIC
Language English
EV1
1 flag
2 flags
Capillary 3: TVZ+Fz
EV2
Capillary 2: Fz
Gas in
Capillary 1: Fr+Fz
EV1
1 flag
Service Manual NEW ARISTON 60 cm PLATFORM
Edition 2006.06.15
16
EN
2.7 FULL NO FROST APPLIANCES:
In Full No Frost appliances, a secondary On/Off type damper (different from the stepper type used in the fridge compartment) has been fitted; when there is a cooling demand from the variable temperature compartment (C.C.Z.), the PCB activates the compressor and after a period of time parameterised in the EEPROM memory it activates the fan and opens the damper, thus cooling the latter. The setting options are: -8°C represented by a STRAWBERRY, -12°C represented by an ICE CREAM and, -18°C represented by a BOTTLE. In the case of defrosting, there is a pre-defrosting procedure when the fan is activated and the damper is opened for a period of time parameterised in the eeprom memory. For the defrosting characteristics/procedure, consult the Indesit New Cold Platform manual. After defrosting, the compressor continues running for a period of time prior to the opening of the secondary damper in order to prevent circulation of any warm air.
Damper ON-OFF Polystyrene conveyor 1 Damper connection housing Base FZ
Variable temp. comp. drawer
Position air probe variable temp. comp. (located inside refrigerator)
L shaped separator
Support 2
Cold air from base to damper
Conveyor 1
Cold air from damper to vents
Service Manual NEW ARISTON 60 cm PLATFORM
Edition 2006.06.15
Language English
17
OPERATING LOGIC
EN
3. COMPONENTS:
ELECTRONIC THERMOSTAT NO FROST COMBI.
Damper
Display PCB
Variable temperature compartment separator panel
Service Manual NEW ARISTON 60 cm PLATFORM
Edition 2006.06.15
Language English
18
COMPONENTS
EN
4. WIRING DIAGRAMS:
Legend
AC CO PT C RH VZ R1, R2 TF TP IF LR S Power supply Compressor Starter relay Running condenser (where fitted) Klixon thermoprotector NF freezer fan Defrosting element Thermo fuse Thermoprotector Fridge door button/magnetic reed Fridge light Fridge air probe
S
1 3
W4
IF
W3
1 3 3 2 1
78
LR
W1
RH
C
PT
CO
VZ
AC
R2 TP TF
R1
Service Manual NEW ARISTON 60 cm PLATFORM
Edition 2006.06.15
1 2 3 4
W2
Language English
19
WIRING DIAGRAMS
c
m
s
EN
Wiring diagram for Combi No Frost
A B C D E
Thermo fuse Thermoprotector Evaporator element Drip tray element Freezer fan
Wiring Diagram Double Door No Frost
WIRING DIAGRAMS
A B C D E
Thermo fuse Thermoprotector Evaporator element Drip tray element Freezer fan
CONNECTIONS
W1 W2 W3 PROBES
COMBI NO-FROST MECHANICAL
YES YES YES WITHOUT IF YES
DOUBLE DOOR NO-FROST MECHANICAL
YES YES YES YES
Service Manual NEW ARISTON 60 cm PLATFORM
Edition 2006.06.15
Language English
20
EN
4.2 FULL WIRING DIAGRAM
Legend
AC CO PT C RH E1 VZ R1, R2 T1, T2 IF LR VR LZ E2 VA D1 Power supply Compressor Starter relay Running condenser (where fitted) Klixon thermoprotector Solenoid valve NF freezer fan Defrosting element Thermo fuse Fridge door button/magnetic reed Fridge light AIR fridge fan Freezer light Variable temperature compartment solenoid valve Vacuum switch (no measurable signal) Variable temperature compartment damper on/off switch (J7 pin 1-3 power supply 100V, pin 4-5 open/close reed limit switch) Vacuum pump Stepper damper (12V signal not measurable) Serial line Interface card with microprocessor (J13 pin 3-4 power supply 12V, with ref. to 220V do not touch the powered card) Evaporator probe (fridge for static models, freezer for NF) Fridge air probe Freezer air probe Variable temperature compartment air probe
S4 S1 S2 S3 UI D2
2 4 1 3
PV
4321
123456
1234
12345
2 1
1234
J12
J11 J13
S
J3
J4
D1
J7
543 1
J10
54
J5
J9
3 1
8 76 4 3 1 5 3
LR IF
T1 VZ E1 R1 R2
S UI
1 2 3
PV D2
J1
T2
S1 S2 S3 S4
RH AC
c m
CO
s
PT
C
Service Manual NEW ARISTON 60 cm PLATFORM
Edition 2006.06.15
Language English
21
WIRING DIAGRAMS
VR
J2
J8
1 2
1 2 3 4 5 6
J6
3 1 4 2
VA E2 LZ
EN
Solenoid valve diagram for variable temperature compartment (CCZ)
A B C Capillary 1: Fridge fridge Capillary 2. Freezer Capillary 3: Special compartment + Freezer Gas in
2 flags
EV2
C
B
EV1
1 flag
A
Wiring diagram for Combi No Frost
A B C D E Thermo fuse Thermo fuse Evaporator element Drip tray element Freezer fan
CONNECTIONS
J1 J2 J3 J4 J5 J6
STATIC CCZ TOUCH
YES YES ------YES ----
STATIC CCZ UI LED
YES AIR (1-3) LAMP. FR (4-6) ------YES ----
NO-FROST CCZ EF TOUCH
YES LAMP. FR (4-6) INT. FR (4-6) YES YES ---DEFROST.EL. FREEZ.FAN (3-4) (5-6) YES ------VACUUM SWITCH (5-6) YES VS AIR PROBE (3-4) YES
NO-FROST EF UI LED
YES LAMP. FR (4-6) YES YES ---DEFROST.EL. FREEZ.FAN (3-4) (5-6) ---------VACUUM SWITCH (5-6) YES ---YES
J7 J8 J9 J 10 J 11 J 12 J 13
---YES ------YES VS AIR PROBE (3-4) YES
---YES ------YES VS AIR PROBE (3-4) YES
Service Manual NEW ARISTON 60 cm PLATFORM
Edition 2006.06.15
Language English
22
WIRING DIAGRAMS
EN
5. ASSISTANCE:
5.1. DEMO MODE:
This mode is not available in products with Electronic Thermostat or Control Knob Interface. For appliances with Touch Interface, without any great energy consumption (approx. 3 W) the Demo Mode makes it possible to show the appliance's full potential, so it appears as if the appliance is switched on and operating normally, but without any load. To activate the DEMO mode, simply switch off the appliance (On/Off button) and press the I CARE + HOLIDAY buttons at the same time for six seconds. The fridge and freezer displays will show "dEon" and the Buzzer will beep. To deactivate and return to normal operation, press the same buttons (I CARE + HOLIDAY) for three seconds. The displays will show "dEoF" and the buzzer will beep again. During Demo mode, every six seconds the fridge and freezer displays will show "dEon" for around two seconds. In the event of a power failure, when power is restored the appliance will continue in DEMO mode.
5.2. AUTO TEST:
AUTOTEST in appliances with Electronic Thermostat: Electronic Thermostat Autotest:
The Autotest function is activated by carrying out the following movements with the thermostat knob:
1. Turn the thermostat knob to the minimum setting (applianceOFF)
2. Turn the knob from OFF to the maximum setting.
Service Manual NEW ARISTON 60 cm PLATFORM
Edition 2006.06.15
Language English
23
ASSISTANCE
EN
3. Turn the knob from maximum to minimum (appliance OFF). The function terminates automatically after 255 seconds.
It is possible to halt or exit the AUTOTEST function by switching the appliance on with the thermostat knob or by disconnecting the appliance from the power supply and then reconnecting it. With regard to appliance loads driven by the PCB during during the autotest procedure, any faults will be signaled by flashing of the fridge lamp. Note.: remember the important points with regard to Autotest on these appliances.
AUTOTEST in Appliances with Knob Controls:
To activate the Autotest procedure, turn the Fridge and Freezer knobs to OFF and press the Super Freeze button for more than 3 seconds (all the leds light up for 5 seconds). The function terminates automatically after 255 seconds (time parameterised for the autotest) or, it can be terminated by the user by switching on the appliance using the freezer knob or by disconnecting and reconnecting the mains power supply. The buzzer emits a beep to signal activation and deactivation.
Any faults will be signaled by flashing of the three Leds on the control panel. As regards the sensors, any faults will be signaled by the three Leds and the flashing of the fridge lamp at the same time. ASSISTANCE
Edition 2006.06.15 Language English
AUTOTEST in appliances with TOUCH interface:
To activate the AUTOTEST procedure, turn the appliance off (On/Off button) and press the following buttons at the same time for six seconds: Super Cool + Super Freeze + Ice Party. Upon activation, the red led "Ever Fresh" (where featured) lights up for 2 seconds, after which all the leds light up for 5 seconds (Ever Fresh blue). The function terminates automatically after 255 seconds (time parameterised for the autotest) or, it can be terminated by the user by switching on the appliance (pressing the On/Off button) or by disconnecting and reconnecting the mains power supply. The buzzer emits a beep to signal activation and deactivation.
Service Manual NEW ARISTON 60 cm PLATFORM
24
EN
5.3 AUTOTEST SEQUENCE:
Model: ELECTRONIC THERMOSTAT
Duration of Autotest procedure: 255 seconds. Test sequence: 1. test defrosting element (8 seconds) pause 3 seconds 2. test freezer air probe (8 seconds) pause 3 seconds 3. test freezer fan (8 seconds) pause 3 seconds 4. Element and fan on for approx. 230 seconds. Fault signalling: After each step the appliance light switches on steady to indicate that the test detected no faults, or flashing to indicate faults. Note. do not forget the important points for correct autotest sequence (e.g.: the Freezer compartment temperature must be below -10°C).
Model: COMBI NO-FROST BASIC
Model: COMBI STATIC BASIC
Duration of Autotest procedure: 255 seconds. Test sequence: The probes are tested for the first 5 seconds of the procedure. 10 seconds after Autotest activation, the freezer fan switches on and runs until the end of the procedure. Fault signalling: Any faults are signalled by a specific combination of leds on the interface. In the event of Probe faults, the fridge lamp will also flash.
Service Manual NEW ARISTON 60 cm PLATFORM
Edition 2006.06.15
Language English
25
ASSISTANCE
Duration of Autotest procedure: 255 seconds. Test sequence: The probes are tested for the first 5 seconds. 10 seconds after Autotest activation, the freezer fan and defrost elements switch on and remain in operation until the end of the test. 10 seconds after activation of the Autotest, the electronic damper is opened for 125 seconds and then closes again at the end of the autotest. Fault signalling: Any faults are signaled by a specific combination of leds on the interface. In the event of Probe faults, the fridge lamp will also flash.
EN
Model: COMBI STATIC BASIC with CCZ
Duration of Autotest procedure: 255 seconds. Test sequence: The probes are tested for the first 5 seconds of the procedure. 10 seconds after Autotest activation, the freezer fan switches on and runs until the end of the procedure. Fault signalling: Fault signalling: Any faults are signalled by a specific combination of leds on the interface. In the event of Probe faults, the fridge lamp will also flash.
Model: COMBI STATIC TOUCH with CCZ
Duration of Autotest procedure: 255 seconds. Test sequence: The probes are tested for the first 5 seconds of the procedure. 10 seconds after Autotest activation, the freezer fan switches on and runs until the end of the procedure. Fault signalling: Any faults are signalled on the fridge and freezer displays (e.g. F01). In the event of Probe faults, the fridge lamp will also flash.
Model: COMBI NO-FROST TOUCH with CCZ and Ever Fresh
Duration of Autotest procedure: 255 seconds. Test sequence: The probes are tested for the first 5 seconds. 10 seconds after Autotest activation, the freezer fan and defrost elements switch on and remain in operation until the end of the test. 10 seconds after activation of the Autotest, the electronic damper is opened for 125 seconds and then closes again at the end of the autotest. 10 seconds after activation of the Autotest, the electronic damper in the variable temperature compartment is opened for 125 seconds and then closes again at the end of the autotest. Fault signalling: Any faults are signalled on the fridge and freezer displays (e.g. F01). In the event of Probe faults, the fridge lamp will also flash.
Service Manual NEW ARISTON 60 cm PLATFORM
Edition 2006.06.15
Language English
26
ASSISTANCE
EN
5.4 LED INDICATED FAULTS AND SOLUTIONS:
1
Legend: 1 = LED 1; 2 = LED 2; 3 = LED 3; Reading of faults shown by LEDs
2
3
The control panel LEDs light up, to signal the fault, according to the following table (the LEDs stay on while the fault lasts).
Signal Faults LED 1 F01 F02 F03 F04 F05 F06 F07 F08 F09 F12 F14 F21 F22 F23 F24 F25 off on off on Flashing on off Flashing Flashing off on on Flashing Flashing off on LED 2 Flashing Flashing Flashing Flashing Flashing Flashing Flashing Flashing Flashing off off on on on on off
Non-blocking Faults
LED 3 off off on on Flashing Flashing off Flashing on on Flashing on Flashing Flashing Flashing
ASSISTANCE
on
Table. Led Faults Blocking Faults
Service Manual NEW ARISTON 60 cm PLATFORM
Edition 2006.06.15
Language English
27
EN
FAULT
CAUSE
CORRECTIVE ACTIONS
- Check for water leaks that may affect connector J1 causing the relative contacts to short; - Check motor terminal board (possible problems due to incorrect connection which may cause short-circuits); - Renew motor; - Renew PCB. - Check efficiency of contacts on connector J1 on the PCB; - Check on wiring connector J1 between pins 3 and 2 for an impedance value that is compatible with the value given in the specific table. - Check that the compressor is not stopped due to overtemperature conditions (thermal cutout open) - Renew motor; - Renew PCB. - Renew PCB. - Check efficiency of contacts on connector J6 on the PCB; - Check impedance on wiring connector J6 between pins 2 and 1 checking that the value is compatible with the value given in the relevant table; - Check correct connection of the freezer fan on the freezer compartment wiring junction box; - Renew freezer fan unit; - Renew PCB.
F1
Compressor relay sticking
F2
Compressor relay open
F3 F4
Faulty power board Freezer fan unit does not run
F5
Electronic damper does not - Check efficiency of J3 connector contacts on PCB; - Check efficiency of connection of electronic damper at foam protected connector close/open
behind multiflow; - Renew electronic damper; - Renew PCB.
- Check efficiency of contacts on connector J6 on the PCB;
F6
Triac driving defrost heating ele- - Check condition by checking for impedance on wiring connector J6 pins 3 and 4; - Check connections of the defrost heating elements and possible short circuits on the ment short-circuit
freezer compartment wiring junction box; - Renew heating element. - Renew PCB - Check efficiency of contacts on connector J6 on the PCB; - Check for continuity of the defrost heating element on pins 3 and 4 of connector J6, ensuring that the impedance value read is compatible with the value given in the relevant table; No power draw of defrost heat- Check for correct connection of the defrost heating element and the drip tray heating ing element element on the freezer compartment wiring junction box; - Check the correct impedance value on the defrost heating element across the heating element terminals; - Check that the fuses have not blown; - Renew defrost heating element; - Renew PCB. - Check efficiency of contacts on connector J8 on the PCB;
F7
F8
Incorrect switching of solenoid - Check for impedance on wiring connector J8 pins 1 and 2 and ensure that the value is compatible with the value given in the relevant table; valve
- Check correct switching of the solenoid valve With the compressor running, check that the solenoid valve switches when the refrigerator compartment is set to OFF. - Renew solenoid valve; - Renew PCB.
F9
File setup error (EEPROM not - In the case of a production PCB, renew PCB and EEPROM; - In the case of replacement PCB and EEPROM, check correct insertion of EEPROM in programmed or faulty)
PCB socket.
Service Manual NEW ARISTON 60 cm PLATFORM
Edition 2006.06.15
Language English
28
ASSISTANCE
EN
FAULT
CAUSE
CORRECTIVE ACTIONS
F10
NO-FROST Models: Faulty ON/OFF DAMPER - Check efficiency of contacts on connector J7 on the PCB; - Check efficiency of the damper connection to the connector inside the air duct in the variable temperature refrigerator compartment; NO-FROST Models: Faulty ON/ - Renew ON/OFF damper; - Renew PCB. OFF DAMPER STATIC Models with CCZ: SEC- CCZ STATIC models with SECONDARY SOLENOID VALVE fault ONDARY SOLENOID VALVE - Check efficiency of contacts on connector J5 on PCB; - Check impedance on wiring connector J5 pins 1 and 2, ensuring that the value is FAULT compatible with the value given in the relevant table; - Check correct switching of the solenoid valve. With the compressor running, check that the solenoid valve switches when the variable temperature compartment is set to OFF. - Renew solenoid valve; - Renew PCB. Check For LED interface PCB: - Check efficiency of contacts on connector J13 on PCB; - Check continuity of connector J13 / LED PCB 5-way and 7-way connectors; - Renew main PCB; - Renew display PCB; For Indesit digit interface PCB and Ariston LED interface PCB on appliances with CCZ and/or Ever Fresh System: - Check efficiency of contacts on connector J13 on PCB; - Check continuity of connector J13/ interface PCB 4-way connector; No communication between dis- - Renew main PCB; - Renew display PCB. play PCB and control PCB For Touch interface PCB: - Check efficiency of contacts on connector J13 on PCB; - Check continuity of connector J13/interface PCB 4-way connector; - Check continuity of connector J13/connector inside cabinet control panel; - Check continuity of connector inside cabinet control panel / interface PCB 4-way connector; - Renew main PCB; - Renew display PCB.
F12
F14
Faulty power board
- Renew PCB.
F16
Fridge fan unit does not run
F17
Vacuum pump does not work
- Check efficiency of contacts on connector J4 on PCB; - Check impedance on wiring connector J4 pins 1 and 2, ensuring that the value read is compatible with the value given in the relevant table; - Renew vacuum pump; - Renew main PCB. Check efficiency of contacts on connector J2 on PCB; Check for impedance on wiring connector J2 pins 4 and 6; Renew lamps; Renew main PCB.
F20 F21 F22
Fridge lamp fails to switch on
NTC ambient probe UI
- Renew main PCB.
- Check efficiency of contacts on connector J11 on the PCB; - Check NTC probe, ensuring that the impedance value read on pins 3 and 4 of FRIDGE Air NTC probe open / wiring connector J11 is compatible with the values in the temperature-impedance correlation table (also heat the probe by holding it with your hand where short circuit possible and checking the change in the impedance value); - Renew main PCB.
Service Manual NEW ARISTON 60 cm PLATFORM
Edition 2006.06.15
Language English
29
ASSISTANCE
- Check efficiency of contacts on connector J2 on PCB; - Check for impedance on wiring connector J2 pins 3 and 1, ensuring that the value read is compatible with the value given in the relevant table; - Check correct connection of the fridge fan inside refrigerator compartment; - Renew fridge fan unit; - Renew main PCB.
EN
FAULT
CAUSE
CORRECTIVE ACTIONS
F23
- Check efficiency of contacts on connector J11 on the PCB; - Check NTC probe, ensuring that the impedance value read on pins 1 and 2 of FRIDGE Evaporator NTC probe wiring connector J11 is compatible with the values in the temperature-impedopen / short-circuit ance correlation table (also heat the probe by holding it with your hand where possible and checking the change in the impedance value); - Renew main PCB. - Check efficiency of contacts on connector J11 on the PCB;
F24
FREEZER Air NTC probe open / - Check NTC probe, ensuring that the impedance value read on pins 5 and 6 of wiring connector J11 is compatible with the values in the temperature-impedshort-circuit ance correlation table (also heat the probe by holding it with your hand where
possible and checking the change in the impedance value); - Renew main PCB. - Check efficiency of contacts on connector J11 on the PCB; - Check NTC probe, ensuring that the impedance value read on pins 1 and 2 of FREEZER Evaporator NTC probe wiring connector J11 is compatible with the values in the temperature-impedopen / short-circuit ance correlation table (also heat the probe by holding it with your hand where possible and checking the change in the impedance value); - Renew main PCB. - Check efficiency of contacts on connector J12 on the PCB; - Check NTC probe, ensuring that the impedance value read on pins 3 and 4 of wiring connector J11 is compatible with the values in the temperature-impedCCZ Air NTC probe open / shortance correlation table (also heat the probe by holding it with your hand where circuit possible and checking the change in the impedance value); - Renew main PCB.
F25
F26
F28 F40 F41 F42 F43 F44 F45 F46 F47 F49 F50 F51 F52 F53
Display PCB does not work "ON/OFF " button does not work "I Care" button does not work "Holiday" button does not work "ICE PARTY" button "Ever Fresh" button "Super Freeze" button "Super Cool" button "Alarm" button FRIDGE "+" button FRIDGE "-" button CCZ button FREEZER "+" button FREEZER "-" button
- Renew Touch display PCB - Renew Touch display PCB - Renew Touch display PCB - Renew Touch display PCB - Renew Touch display PCB - Renew Touch display PCB
- Renew Touch display PCB - Renew Touch display PCB - Renew Touch display PCB - Renew Touch display PCB - Renew Touch display PCB - Renew Touch display PCB - Renew Touch display PCB
Service Manual NEW ARISTON 60 cm PLATFORM
Edition 2006.06.15
Language English
30
ASSISTANCE
- Renew Touch display PCB
EN
5.6 Troubleshooting:
FAULT
Fails to switch on. Compressor fails to start.
REMEDY
- Check voltage on mains socket outlet. - Check power cord. Check continuity of windings. Check operation of Klixon relay. Faulty PCB. Appliance set to OFF.
Compressor runs but appliance fails to cool.
- Compressor is cold - check refrigerant charge. - Compressor is very hot - Check for traces of oil or refrigerant circuit is blocked. - Check for possible faulty compressor. - Faulty Klixon relay. - Faulty compressor. - Mains voltage too low. - Drain hole blocked. - Container or wrapping paper touching refrigeration walls. - Condensation collection bowl ruptured. - Water drain tube incorrectly positioned. - Condensation collection bowl not in contact with compressor. Faulty thermostat. Incorrectly positioned thermostat. Unsuitable electrical installation on Klixon. Door closure fault. Refrigerant circuit insufficient charge or blocked.
Compressor unable to start. Water under crisper drawers. Water on floor.
Compressor fails to stop.
Compressor fails to start. Door open alarm sounds continuously. Display switches off occasionally. For No-Frost: Compartments are not very cold. For No-Frost: Refrigerator compartment not cold enough. For No-Frost: Refrigerator compartment too cold food tends to freeze.
- Damaged compressor. - Check Thermostat/PCB. - No magnet in door. - Faulty PCB. - Door is distorted. - Check display cable. - Check display PCB. - Evaporator coil clogged with ice. - Check thermo fuse. - Check heating elements. - Chilled air suction fan motor. - Ice has formed in the duct between the refrigerator and freezer compartments. - Check temperature probes. - Damper does not close properly
Service Manual NEW ARISTON 60 cm PLATFORM
Edition 2006.06.15
Language English
31
ASSISTANCE
EN
5.7 DISMANTLING: 5.7.1 TOUCH INTERFACE:
Removing the Display PCB:
1. Attach some adhesive tape to the bottom of the PCB to prevent damage to the panel.
4. Release the 2 screws (one top, one bottom) that secure the PCB.
2. Using a screwdriver, prise the PCB off at the bottom on each side.
5. Pull to remove the PCB and disconnect the terminals.
3. Remove the surround carefully.
6. PCB disconnected.
Service Manual NEW ARISTON 60 cm PLATFORM
Edition 2006.06.15
Language English
32
ASSISTANCE
EN
Removing components of the Variable Temperature Compartment:
1. Remove the drawers from the freezer compartment.
4. Release the 5 screws of the freezer damper housing.
2. Release the screws of the shelf of the variable temperature compartment.
5. Remove the damper housing, taking care not to damage the connection.
3. Remove the shelf
Service Manual NEW ARISTON 60 cm PLATFORM
Edition 2006.06.15
Language English
33
ASSISTANCE
EN
Removing components of the Variable Temperature Compartment:
2. Remove the shelf.
1. Release the screws of the shelf of the variable temperature compartment. ASSISTANCE
Service Manual NEW ARISTON 60 cm PLATFORM Edition 2006.06.15 Language English
34
EN
6. EXPLODED VIEWS
6.1.1 INTERNAL DETAILS
Ref. 000 000 001 002 003 003 004 005 006 006 007 007 008 009 010 011 012 013 014 015 016 017 018 019 019
Description HANDBOOK MBT1821-2022Z (IT-GB-FR-ES-PT-PL) HANDBOOK MBT022Z (CZ-RO-HU) ALUMINIUM CONTROL PANEL-K22 596X55X298 "AR05" TOP HINGE (D.9) RT-LT CHROME TOP HINGE COVER RT ALUMINIUM-K22 TOP HINGE COVER LT ALUMINIUM-K22 COVER 75X21 CONTROL PANEL ALUMINIUM CABINET POLARW REAR GLASS PROFILE (474x55) GLASS SHEF (472X328X4) CHILLER GLASS SHELF (472X270X4) POLARW FRONT GLASS PROFILE 505X78X15 PW FRONT PROFILE CHILLER GLASS 504X42 PW REAR PROFILE/ CRISPER GLASS (L.502) GLASS TRAY -CHILLER (478X269X4) GLASS PROFILE CRISPER 504X78X9 POLARW PW CHILLER WHEEL PW CHILLER DRAWER (LXH 480X113X266) RUNNER BUSHING PW CHILLER DRAWER RUNNER/CHILLER RT POLARW 370X200 DRAWER RUNNER/CHILLER LT POLARW 370X200 CHILLER FRONT LIGHT GREEN-PW 480X123X30 POLARW FRIDGE SEPARATOR PANEL 497X295X22 CRISPER COVER PROFILE PW 504X93(PINS 6.5MM) RUBBER SHEET COVER PW GLASS CRISPER FLAP (L.491X164)
Ref. 020 021 022 023 024 024 025 026 027 028 029 030 031 032 033 034 035 036 037 038 039 040 041 042
Description CLEAR CRISPER FRONT 492X155 CRISPER DRAWER P0LARW (465X434X137 SUPER. DRAWER POLARW (LXP 434X394x123) SUP. DRAWER FRONT (429X155) GLASS/PW POLARW FREEZER SEPARATOR PANEL 434X421X49 SEPARATOR RETAINER POLARW MIDDLE DRAWER LXP 434X392 ICE TRAY (LXH)398X64 ARISTON DRAWER FRONT (429X240) GLASS/PW BOTTOM DRAWER POLARWH (LXP 433X227) DRAWER FRONT (LxH 429X197) GLASS/PW ICE SCRAPER (730412) COMPLETE ICE PACK ARISTON ALUMINIUM PLINTH PLUG-K22 ALUMIUM PLINTH+ DRAIN 594X72X75 "AR-05" ADJUSTABLE FOOT D.17.7X37.5 BOTTOM HINGE (M6) RT-LT CHROME HINGE PIN M6X (3.5+10) "SKME1650" BOTTOM HINGE PLATE 30X40 (6 HOLES) WHITE DRAIN PLUG D.10.5 MM "INDESIT" FINISH COVER 56-GREY D.4.5X3M "HINGE" CENTRAL HINGE CHROME FINISH STEEL CONDENSATION DRAIN PIPE D.14.5X950 MM "IND" FRIDGE CLEANING BRUSH (D.6X120) "RF-ROUND"
Service Manual NEW ARISTON 60 cm PLATFORM
Edition 2006.06.15
Language English
35
EXPLODED VIEWS
EN
6.1.2 doors and components
Ref. 001 002 003 004 005 006 007 008 009 010 013 014 015
Description ALUMINIUM PLUG (H.6.4 D.12/14) TOP HINGE PIN M8X3 (18+2.5) DOOR HINGE ARM (M6) GREY BUSHING 3 MM DOOR-DRAWER DOOR EGG COMPARTMENT LXH 500X72X103 (ARISTON) EGG DOOR TRAY LXH 498X82X111(GLASS) EGG HOLDER X 6 (152X95X20) GREEN GLASS INTERM. DOOR TRAY 500X44X111(GLASS/PW) CAN HOLDER PW/LIGHT GREEN (361X83) BUTTER DISH (152X50X93) KIT BOTTLE RETAINER PROFILE POLARW L=452X63 BOTTLE HOLDER DOOR TRAY 500X183 GLASS /PW DOOR CLOSURE BUSHING RT GREY 40ø 60219...
Ref. 015 015 015 016 017 018 019 020 021 022 023 024
Description DOOR CLOSURE BUSHING LT GREY 40ø 60219... DOOR CLOSURE BUSHING LT GREY 49ø 00218... DOOR CLOSURE BUSHING RT GREY 49ø 60218... FREEZER DOOR-ARISTON STAINLESS STEEL 592X803X71 DOOR SEAL POLAR WHITE (552X713) PLUG AL/SILVER X BUSHING H.14 D.13.8/ GREY BUSHING 4 MM "DOOR HINGE" FRIDGE DOOR ARIS. STAINLESS STEEL 592X1140X71DISPLAY DOOR SEAL POLAR WHITE (552X1050) ARISTON LOGO CONTROL PANEL COVER ALUM. DOOR 586X47(NSPIE MAGNET. SWITCH 15X10X5 DOOR CLOSED
Service Manual NEW ARISTON 60 cm PLATFORM
Edition 2006.06.15
Language English
36
EXPLODED VIEWS
EN
6.1.3 functional components
Ref. 001 002 003 004 005 006 007 008 010 011
Description LEFT FIXTURE EVAPORATOR "C138 IND00" RIGHT FIXTURE EVAPORATOR "C138 IND00" WHITE PROFILE L=443.5 MM "FIX.EVAP" FREEZ.EVAP.CONDENSER L407X473(10PIPELINES+ROUND SOLENOID VALVE FIX.BRACKET 3-WAY SOLENOID BITRON 220/50 R134-R600 3-WAY SOLENOID BITRON 220/50 R134-R600 RUNNING CONDENSER 4MF (ATT.RAP.8MM) POWER CORD 3X0.75 EU MM 2500 COMPRESSOR CROSSPIECE 586X110 MM UNIT.
Ref. 012 013 014 015 016 017 018 019 020
Description RUBBER DAMPER "EMBRACO EM-PW-FF" COMPRESSOR FIXING PLATE (750908) COMPR. HTK95AA 220-240/50 1/5HP-167W R60 LOKRING PIPE WITH VALVE (6 NFMSSV) CONDENSATION COLLECTION TAB 209X175X58 (POLAND) FILTER GR.12 (D.4.8/D.3.2 MM) GAS R600A CONDENSER 576X1200x48 (R600) WALL MOUNTED SPACER X CONDENSER "IND.00" POWER CORD HOOK
Service Manual NEW ARISTON 60 cm PLATFORM
Edition 2006.06.15
Language English
37
EXPLODED VIEWS
EN
6.1.4 OTHER COMPONENTS
Ref. 001 002 006 006 007 008 009 009 010 010 011 012 013 014
Description MAGNETIC SENSOR SWITCH WIRING J13E DISPLAY-MODULE TOUCH KIT DISPLAY 60621... TOUCH DISPLAY ROHS KIT 60622... ALUMINIUM SURROUND TOUCH DISPLAY ADHESIVE SPONGE TOUCH DISPLAY 415X6X3 AL. TAPE H50MMX50MT.X GLASS P.F (1PZ=1M) LIGHT BOX (LIGHT XTRA) LAMP HOLDER (VOSSLOH)250V E14 "GIUGIARO" WIRING-AMP FRIDGE LAMP LAMP 220-240V/15W (E14) LAMP COVER (MAX 15W) COLOUR 44 FAN MOTOR SUPPORT-AIR (PW) RUBBER STOP FAN MOTOR "NO-FROST"
Ref. 015 016 017 018 019 020 021 022 023 024 025 026
Description FAN UNIT C09R1907 220V 3.5W (FATON) FAN MOTOR SUPPORT-AIR (COMPL) PW COVER MOTOR TURBOCOOLING "ARISTON" PROBE FIXTURE "C238" EEPROM COMBY2005 SW 28348120001 ST-FULL FULL POWER BOARD WITHOUT EEPROM COMPRESSOR WIRING SOLEVNOID VALVE WIRING EV1 SOLENOID VALVE WIRING (EV2) MODULE HOLDER-SMD MODULE HOLDER COVER-SMD SERIAL PLUG
Service Manual NEW ARISTON 60 cm PLATFORM
Edition 2006.06.15
Language English
38
EXPLODED VIEWS
EN
6.2.1 INTERNAL DETAILS
Ref. 000 000 000 001 002 003 003 004 005 006 006 007 008 008 009 010 011 012 012 013 014 015 016 017
Description HANDBOOK MBT1812-2012IZS (IT-GB-FR-ES-PT) HANDBOOK MBT2012IZS (PL-RO) QUICK REFERENCE TOUCH ARISTON ALUMINIUM CONTROL PANEL-K22 596X55X298 "AR05" TOP HINGE (D.9) RT-LT CHROME TOP HINGE COVER RT ALUMINIUM-K22 TOP HINGE COVER LT ALUMINIUM-K22 COVER 75X21 CONTROL PANEL ALUMINIUM CABINET POLARW REAR GLASS PROFILE (474x55) GLASS SHEF-NF (472X321X4) GLASS SHEF-NF (472X321X4) ROHS POLARW FRONT GLASS PROFILE 505X78X15 GLASS SHEF-EVER FRESH (472X296X4) GLASS SHEF-EVER FRESH (472X296X4) ROHS EVER FRESH BOX POLAR WHITE COMPLETE SUPPORT EVER FRESH BUTTON COMPLETE RUBBER HOSE DI.4/DE.7 L=450MM SILICON SEAL (EVER FRESH) VACUUM ELBOW SEAL CROSS RUNNER BUSHING PW CHILLER DRAWER RUNNER/CHILLER LT POLARW 370X200 DRAWER RUNNER/CHILLER RT POLARW 370X200 FRIDGE SEPARATOR PANEL POLARW 497X282X30 CRISPER COVER PROFILE PW 504X93(PINS 6.5MM)
Ref. 018 019 019 020 021 022 023 024 025 026 027 028 029 030 031 032 033 034 035 036 037 038 038
Description CHILLER WHEEL PW RUBBER SHEET COVER PW GLASS CRISPER FLAP (L.491X164) CLEAR CRISPER FRONT 492X155 CRISPER DRAWER P0LARW (465X434X137 SUPER. DRAWER POLARW (LXP 434X300x123) SUP. DRAWER FRONT (429X155) GLASS/PW FREEZER SEPARATOR PANEL-NF POLARW 435X330X38 MIDDLE DRAWER POLARW LXP 434X300 ICE TRAY (LXH)398X64 ARISTON DRAWER FRONT (429X240) GLASS/PW BOTTOM DRAWER POLARWH (LXP 433X227) DRAWER FRONT (LxH 429X197) GLASS/PW COMPLETE ICE PACK ARISTON ALUMINIUM PLINTH PLUG -K22 ALUMINIUM PLINTH + DRAIN 594X72X75 "AR-05" ADJUSTABLE FOOT D.17.7X37.5 BOTTOM HINGE (M6) RT-LT CHROME HINGE PIN M6X (3.5+10) "SKME1650" BOTTOM HINGE PLATE 30X40 (6 HOLES) FINISH COVER 56-GREY D.4.5X3M "HINGE" CENTRAL HINGE CHROME FINISH STEEL CENTRAL HINGE ZAMAK
Service Manual NEW ARISTON 60 cm PLATFORM
Edition 2006.06.15
Language English
39
EXPLODED VIEWS
EN
6.2.2 DOORS AND COMPONENTS
Ref. 001 002 003 004 005 006 007 008 009 010 011 012
Description ALUMINIUM PLUG (H.6.4 D.12/14) TOP HINGE PIN M8X3 (18+2.5) DOOR HINGE ARM (M6) GREY BUSHING 3 MM DOOR-DRAWER DOOR EGG COMPARTMENT LXH 500X72X103 (ARISTON) EGG DOOR TRAY LXH 498X82X111(GLASS) EGG HOLDER X 6 (152X95X20) GREEN GLASS INTERM. DOOR TRAY 500X44X111(GLASS/PW) CAN HOLDER PW/LIGHT GREEN (361X83) BUTTER DISH (152X50X93) KIT BOTTLE RETAINER PROFILE POLARW L=423X39 BOTTLE-HOLDER DOOR TRAY 500X104(GLASS/PW)
Ref. 015 015 016 017 018 019 020 021 022 023 024
Description DOOR CLOSURE BUSHING RT GREY 40ø DOOR CLOSURE BUSHING LT GREY 40ø FREEZER DOOR-ARISTON STAINLESS STEEL 592X803X71 DOOR SEAL POLAR WHITE (552X713) PLUG AL/SILVER X BUSHING H.14 D.13.8/ GREY BUSHING 4 MM "DOOR HINGE" FRIDGE DOOR-NF AR.IX 592X1140X71 DISPLAY DOOR SEAL POLAR WHITE (552X1050) ARISTON LOGO CONTROL PANEL COVER ALUM. DOOR 586X47(NSPIE MAGNET. SWITCH 15X10X5 DOOR CLOSED
Service Manual NEW ARISTON 60 cm PLATFORM
Edition 2006.06.15
Language English
40
EXPLODED VIEWS
EN
6.2.3 FUNCTIONAL COMPONENTS
Ref. 001 002 003 003 004 005 006 007 008 009 010 011 011 012 023
Description EVAPORATOR KIT-FZ NF-26 PIPES (ELECTR) ELEMENT KIT + THERMOFUSE 125W/72°C EVAPORATOR SPONGE (HXLXSP) 41X43X25 EVAPORATOR SPONGE (HXLXP) 41X50X42 FAN MOTOR SUPPORT (NO FROST) RUBBER STOP FAN MOTOR "NO-FROST" FAN UNIT F6410 220V 3.5W (AMP-4VIE ADHESIVE SPONGE ELBOWS NF (58X108X3) ALUMINIUM PANEL COMBY NF FREEZER AIR CONVEYOR KIT COMBY NF60 CONTROL PANEL COVER 74X20 CABINET POLAR-WHI ADHESIVE SPONGE L=500X12 ADHESIVE SPONGE L=1300x12x5 FREEZER BASE KIT PW (NF) 401X530 VACUUM PUMP SUPPORT
Ref. 024 025 026 027 028 029 030 031 032 032 033 035 036 099 099
Description VACUUM PUMP ASSEMBLY COMPRESSOR CROSSPIECE 586X110 MM ASSEMBLY. RUBBER DAMPER "EMBRACO EM-PW-FF" COMPR. HTK95AA 220-240/50 1/5HP-167W R60 COMPRESSOR FIXING PLATE (750908) LOKRING PIPE WITH VALVE (6 NFMSSV) CONDENSATION COLLECTION TAB 209X175X58 (POLAND) CONDENSATION DRAIN PIPE MEMBRANE DI.14 MM FILTER GR.12 (D.1.95/D.4MM) GAS R600A "ECO" FILTER GR10(D.1.9/4.9) R134-600 3-WAY KIT CONDENSER IMAT 576X1200x44 (R600) POWER CORD HOOK CONDENSER SPACER DEFROSTING ELEMENT 220V 28.3W (AMP) WIRING COMBY NF (AMP) X SAT
Service Manual NEW ARISTON 60 cm PLATFORM
Edition 2006.06.15
Language English
41
EXPLODED VIEWS
EN
6.2.4 OTHER COMPONENTS
Touch Display
Ref. 001 002 006 006 007 008 009 010 010 011 012 013 014 015 016 017 018 018 019
Description MAGNETIC SENSOR SWITCH WIRING J13E DISPLAY-MODULE TOUCH DISPLAY (EVER FRESH) KIT TOUCH DISPLAY (EVER FRESH) ROHS KIT ALUMINIUM SURROUND TOUCH DISPLAY ADHESIVE SPONGE TOUCH DISPLAY 415X6X3 EEPROM COMBY2005 SW 28365580001 NF-FULL FULL POWER BOARD WITHOUT EEPROM FULL POWER BOARD WITHOUT EEPROM ROHS COMPRESSOR WIRING VACUUM PUMP WIRING MODULE HOLDER-SMD MODULE HOLDER COVER-SMD SERIAL PLUG PROBE FIXTURE "C238" CONDENSER FIXING PLATE RUNNING CONDENSER 4MF (pin M8) RUNNING CONDENSER 4MF (8MM) ROHS POWER CORD 3X0.75 EU MM 2500
Ref. 020 022 023 024 026 027 028 029 030 031 034 036 037 099 099 099 099 099
Description ADHESIVE SPONGE L=500X12 THERM. DAMPER FBZ118F 1W AC100V 50/60HZ ADHESIVE SPONGE (367X324X2) WHITE FREEZER MULTIFLOW ASSEMBLY COMBYNF-IZS LAMP HEAT PROTECTION (80X100X0.1) DAMPER THERMOSTAT DC12C 0.48W NSBA001RF1 DAMPER ADHESIVE SPONGE NF/ELECTRONIC WIRING-AMP FRIDGE LAMP (SURROUND) LAMP HOLDER (VOSSLOH)250V E14 KIT LAMP 220-240V/10W (E14) LAMP COVER (145X85) MULTIFLOW ADHESIVE SPONGE NF-MECHANICAL MULTIFLOW ASSEMBLY H.854 COMBYNF SURROUND ADHESIVE SPONGE H=10x2 (L=75 CM) ADHESIVE SPONGE H=55x2 (L=120 CM) PROBES 4-WAY CONNECTOR (AMP) KIT PROBES 6-WAY CONNECTOR (AMP) KIT ADHESIVE SPONGE L=1300x12x5
Service Manual NEW ARISTON 60 cm PLATFORM
Edition 2006.06.15
Language English
42
EXPLODED VIEWS
EN
6.3.1 INTERNAL DETAILS
Ref. 000 001 002 003 004 005 006 007 008 009 010 011 012 013 014 015 016 017 018 019
Description HANDBOOK MBL1821Z (IT-GB-FR-ES-PT-PL) ALUMINIUM CONTROL PANEL (ELECTRONIC) 596X55 TOP HINGE (D.9) RT-LT CHROME COVER 75X21 CONTROL PANEL ALUMINIUM CABINET (ASO COVER 75X21 CONTROL PANEL ALUMINIUM CABINET POLARW REAR GLASS PROFILE (474x55) GLASS SHEF (472X328X4) POLARW FRONT GLASS PROFILE 505X78X15 PW REAR PROFILE/ CRISPER GLASS (L.502) GLASS SHELF (478X328X4) GLASS PROFILE CRISPER 504X78X9 POLARW WINE AREA ASSEMBLY LIGHT GREEN PROFILE AIR CLOSURE (L.423) POLAR-W GLASS CRISPER DRAWER COVER L=478X333X4(ANG.90 GLASS PROFILE CRISPER 504X78X9 POLARW WHITE CRISPER LXH 240X146X326 "IND4" CLEAR CRISPER FRONT 240X159X30 SUPER DRAWER POLARW (LXP 434X394x123) SUP. DRAWER FRONT (429X155) GLASS/PW ADHESIVE SPONGE L=500X12
Ref. 019 019 020 021 022 023 024 025 026 027 028 029 030 031 032 033 034 035 036
Description FREEZER SEPARATOR PANEL POLARW 434X421X49 SEPARATOR RETAINER MIDDLE DRAWER POLARW LXP 434X392 ICE TRAY (LXH)398X64 ARISTON DRAWER FRONT (429X240) GLASS/PW BOTTOM DRAWER POLARWH (LXP 433X227) DRAWER FRONT (LxH 429X197) GLASS/PW ICE SCRAPER (730412) ALUMINIUM PLINTH PLUG -K22 ALUMINIUM PLINTH + DRAIN 594X72X75 "AR-05" ADJUSTABLE FOOT D.17.7X37.5 BOTTOM HINGE (M6) RT-LT CHROME HINGE PIN M6X (3.5+10) "SKME1650" BOTTOM HINGE PLATE 30X40 (6 HOLES) WHITE DRAIN PLUG D.10.5 MM "INDESIT" FINISH COVER 56-GREY D. 4.5X3M "HINGE" CENTRAL HINGE CHROME FINISH STEEL CONDENSATION DRAIN PIPE D.14.5X950 MM "IND" FRIDGE CLEANING BRUSH (D.6X120) "RF-ROUNDED"
Service Manual NEW ARISTON 60 cm PLATFORM
Edition 2006.06.15
Language English
43
EXPLODED VIEWS
EN
6.3.2 DOORS AND COMPONENTS
Ref. 001 002 003 004 005 006 007 008 009 011 012 013 013
Description ALUMINIUM PLUG (H.6.4 D.12/14) TOP HINGE PIN M8X3 (18+2.5) DOOR HINGE ARM (M6) GREY BUSHING 3 MM DOOR-DRAWER DOOR EGG COMPARTMENT LXH 500X72X103 (ARISTON) EGG DOOR TRAY LXH 498X82X111(GLASS) EGG HOLDER X 6 (152X95X20) GREEN GLASS INTERM. DOOR TRAY 500X44X111(GLASS/PW) CAN HOLDER PW/LIGHT GREEN (361X83) BOTTLE RETAINER PROFILE POLARW L=423X39 BOTTLE-HOLDER DOOR TRAY 500X104(GLASS/PW) DOOR CLOSURE BUSHING RT GREY 40ø 60219... DOOR CLOSURE BUSHING LT GREY 40ø 60219...
Ref. 013 013 016 015 016 017 018 019 020 021 022 023
Description DOOR CLOSURE BUSHING LT GREY 49ø 00218... DOOR CLOSURE BUSHING RT GREY 49ø 60218... FREEZER DOOR-ARISTON STAINLESS STEEL 592X803X71 DOOR SEAL POLAR WHITE (552X713) PLUG AL/SILVER X BUSHING H.14 D.13.8/ GREY BUSHING 4 MM "DOOR HINGE" FRIDGE DOOR ARIS.STAINLESS STEEL 592X1015X71 3-LEDS DOOR SEAL POLAR WHITE (552X925) ARISTON LOGO CONTROL PANEL COVER AL. DOOR 586X47 (3-LEDS LED INDICATOR LENS (A+ CLASS) MAGNET.SWITCH 15X10X5 DOOR CLOSED
Service Manual NEW ARISTON 60 cm PLATFORM
Edition 2006.06.15
Language English
44
EXPLODED VIEWS
EN
6.3.3 FUNCTIONAL COMPONENTS
Ref. 001 002 003 004 005 006 007 008 009 010 010 011 012 013 014 015 016 017 018 019 020 021 022 023
Description LED PCB ARISTON05 BASIC (4 WAY) SPONGE (350X8X8) "CONTROL PANEL C138-238" TRIMMER KNOB ALUMINIUM-MET (C238) LED INDICATOR LENS (CONTROL PANEL) R.EXT 22.7X12.4 ALUMINIUM BUTTON COVER-K22 (H=5.5+7.7 MM) LED INDICATOR LENS (CONTROL PANEL) R.INT. 8.2X9.3 PROBE FIXTURE "C238" AL.TAPE H50MMX50MT.X GLASS P.F (1PZ=1M) LIGHT BOX (DUAL LIGHT) LAMP HOLDER (VOSSLOH)250V E14 "GIUGIARO" WIRING-AMP FRIDGE LAMP LAMP 220-240V/15W (E14) LAMP COVER (MAX 15W) COLOUR 44 FAN MOTOR SUPPORT-AIR (PW) RUBBER STOP FAN MOTOR "NO-FROST" FAN UNIT C09R1907 220V 3.5W (FATON) FAN MOTOR SUPPORT-AIR (COMPL) PW COVER MOTOR TURBOCOOLING "ARISTON" RIGHT FIXTURE EVAPORATOR "C138 IND00" LEFT FIXTURE EVAPORATOR "C138 IND00" WHITE PROFILE L=443.5 MM "FIX.EVAP" FREEZ.EVAP.CONDENSER L407X473(10PIPELINES+ROUND EEPROM COMBY2005 SW 28347950000 ST-STRIP FULL POWER BOARD WITHOUT EEPROM
Ref. 024 025 026 027 028 029 030 032 033 034 035 036 037 038 039 040 041 042 043 044 045 099 099
Description COMPRESSOR WIRING SOLEVNOID VALVE WIRING EV1 SOLENOID VALVE WIRING (EV2) MODULE HOLDER-SMD MODULE HOLDER COVER-SMD SERIAL PLUG RUNNING CONDENSER 4MF (ATT.RAP.8MM) POWER CORD.3X0.75 EU MM 2500 COMPRESSOR CROSSPIECE 586X110 MM ASSEMBLY COMPR. HTK95AA 220-240/50 1/5HP-167W R60 RUBBER DAMPER "EMBRACO EM-PW-FF" COMPRESSOR FIXING PLATE (750908) LOKRING PIPE WITH VALVE (6 NFMSSV) CONDENSATION COLLECTION TAB 209X175X58 (POLAND) 3-WAY SOLENOID BITRON 220/50 R134-R600 3-WAY SOLENOID BITRON 220/50 R134-R600 SOLENOID VALVE FIX.BRACKET FILTER GR.12 (D.4.8/D.3.2 MM) GAS R600A CONDENSER 576X1000x48 (R600) WALL MOUNTED SPACER X CONDENSER "IND.00" POWER CORD HOOK PROBES 6 WAY CONNECTOR (AMP) KIT PROBES 4-WAY CONNECTOR (AMP) KIT
Service Manual NEW ARISTON 60 cm PLATFORM
Edition 2006.06.15
Language English
45
EXPLODED VIEWS
EN
7. APPENDIX:
Probe Temperature Table:
Temperatures (deg C) -20 -19 -18 -17 -16 -15 -14 -13 -12 -11 -10 -9 -8 -7 -6 -5 -4 -3 -2 -1 0
Impedance (Ohms)
96358,15841
Temperatures (deg C) 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20
Impedance (Ohms)
30943,67548
90961,0458 85898,49833 81147,91786 76688,3509 72500,36067 68565,90983 64868,25279 61391,83683 58122,21121 55045,94375 52150,54393 49424,39237 46856,67575 44437,32697 42156,97006 40006,86932 37978,88256 36065,41784 34259,39368 32554,20227
29422,05356 27983,95607 26624,35516 25338,55076 24122,14763 22971,03419 21881,36283 20849,53175 19872,16807 18946,11223 18068,4035 17236,26649 16447,09875 15698,45915 14988,05714 14313,74275 13673,49734 13065,42494 12487,74426
Service Manual NEW ARISTON 60 cm PLATFORM
Edition 2006.06.15
Language English
46
APPENDIX
Indesit Company viale Aristide Merloni, 47 60044 Fabriano - Italy tel. +39 0732 66 11 - telex 560196 - fax +39 0732 66 2954 - www.indesitcompany.com
Service Manual NEW ARISTON 60 cm PLATFORM
Edition 2006.06.15
Language English