Text preview for : ARE006.PDF part of Sharp AR 5132 Technical report
Back to : Technical report.rar | Home
Date : Nov. 15, 1995 DIGITAL COPIER : AR-5040 No. : ARE-006
CHANGES AND ADDITIONS OF PARTS
1.Model name:
AR-5040.
2.General:
Changes and additions of parts have been carried on the machine listed above, and are hereby reported.
3.Description:
(1) The metal pattern of the DSD collar (P/G 17 -52) used in the DV box unit is interchangeable with that of models SF-9400/8870/8800, and the parts code for models SF-9400/8870/8800 is printed on the side face. This is confusing however, and to alleviate the potential of problems due to confusion, the printing has been discontinued and the DSD collar for model AR-5040 is now marked with black to distinguish it. (As is listed in the parts guide, the parts code for model AR-5040 is different from the parts code for models SF-9400/8870/8800.) (2) The black electro deposition used for the surface finishing of the CCD cover of the scanner unit has been changed to black galvanization in order to decrease the noise from the power supply. In addition to the changes described above, the lower face of the cover in the 200V line has been extended to prevent noise from being emitted from the lower face. This new CCD cover is to be used in the machines of the 200V line.
200 V series
Lengthened
From the start of 1994 October production.
1/7
Green C
SHARP CORPORATION
Reprography Division
(3) An ICB and capacitor has been added to the ICU PWB accommodate the special photographic mode. The following parts codes of the ICU PWB have also been changed in accordance with these changes. Added parts VCKYTVIEF104Z (capacitor)added location C105 . C106 VHI74F00SJ/-1 (IC) added location IC70 VHI74F74SJ/-1 (IC) added location IC71
From the start of 1994 December production. (Temporary measures have been carried out since the start of mass production.).
(4) A ferrite core has been added to the CL lead wire as a measure to improve noise (only for models of the 200 V series).
Section wound with tape Ferrite core (RCORF0012FCZZ)
CL Lead wire (DHAI-2344FCZZ)
From the start of 1994 October production.
(5) There was a danger of the rear end of the copy paper getting caught on the upper ST sheet in the staple unit of the 100 V series. To alleviate this problem, the ST sheet has been changed to the one used in the 200 V series. From the start of 1994 December production.
(6) There was a mistake in the parts code listed in the parts guide for the AC cord holder. Correction of the error as described below is requested (only for machines bound for SEEG, UK and Australia). LFIX-0084FCZZ (Mistaken) LFIX-0016FCZZ. (Corrected)
2/7
(7) An ground wire has been added in the operation panel (LCD PWB FG) as a measure to improve noise. (This measure has been carried out only on the 200 V line.)
LCD PWB FG
Lower LCD case surface
Main SW
OPE
LCD PWB FG
Fixing plate
From the start of 1994 October production.
(8) The parts additions and discontinuances listed below have been carried out since the start of mass production after the parts guide was compiled, and are hereby reported. Discontinued part FIN drop sheets (Qty: 2) P/G 51 -131
P/G
47
Sub PG upper unit 51 -51
Added discharge brush. PBRSR0083FCZZ Added discharge brush. PBRSR0141FCZZ
From the start of mass production.
3/7
(9) The fixing screws used to attach the main drive unit and the DR drive unit to the frame have been changed to improve operationability. P/G
9
-9
M4 x 12
M4 x 14 From the start of 1994 October production.
(10) The parts listed below have been added as a measure to reduce noise. (This change has been carried out only on the 200 V series.)
Finished tray Gasket Standard
Front side
Standard
View from the paper side
Mesh wire (QCNW-0138FCZZ) Shift unit
P/G No. 51 gasket added to the FIN joint plate
P/G No. mesh wire added to the finished shift unit
From the start of 1994 October production.
(11) Sheets have been added to the gate section to improve stacking performance.
Added FIN paper discharge sheet
From the start of mass production.
4/7
(12) A ferrite core has been added to the finisher main PWB fixing plate unit in order to comply with the CE mark standards. (This change has been carried out on the 200 V series only.)
P/G No. 55
Added ferrite core
From the start of 1995 April production.
(13) A laser warning label has been added to the front cabinet and to the finisher section. This change has been carried out only on machines bound for SUK.
Laser warning label P/G No. 51 Sub paper guide upper
Laser warning label Sub paper guide upper Laser warning label Laser warning label
P/G No. 48 Front exterior left P/G No. Front exterior right
1
From the start of 1995 April production.
5/7
(14) An additional manual has been added to supplement the explanation contents of the operation manual. This change has been carried out only on machines bound for SUK. From the start of 1995 February production.
(15) Parts in one of the sections of the shield box have been assembled and the assembled unit is being offered as a service part. Furthermore, a carved grounding mark has been added, and the former grounding mark label has been discontinued. P/G No. P/G No. P/G No. P/G No. P/G No. P/G No.
35 -3 35 -8 35 -9 35 -10 35 -11 35 -21
XBPSD40P08KSO. NSFTZ2116FCZZ. LBSHZ0251FCZZ. LPLTM4733FCZZ. PBOX-0100FCZZ. LHLDW2106SCZZ.
Assembled
CBOX-0100FC31
From the start of 1995 May production.
Current parts Ref. No. Model name Version P/G No. Parts code 100V series (2) 200V series 68 -27 68 (3) All 68 -59 35 -17 CPWBN1031FC51 68 -901 AR-5040 (4) 200V series 100V series 12 49 -52 49 -53 SEEG 35 -16 U.K. Australia 200V series 2 -- PSHEP3622FCZZ PSHEP3620FCZZ RCORF0012FCZZ PSHEZ3734FCZZ PSHEP3735FCZZ AH AG AF Ferrite core ST cover sheet Upper ST sheet B 1st lot '94/10 1st lot '94/12 6 CPWBN1031FC52 EZ ICU PWB 1 VCKYTV1EF104Z (Q'ty: 86) -- VHI74F74SJ/-1 (Q'ty: 1) 12 -28 PCOVP1248FCZZ PCOVP1322FCZZ BB Parts code New parts Price rank BA CCD cover 1st lot '94/10 3 Parts name Effec- Intertive changetime ability
Note
PCOVP1321FCZZ
(Q'ty: 88) VHI74F00SJ/-1
AA
Capacitor IC [ IC70 ] 6 1st lot '94/12
AE (Q'ty: 2) IC
(5)
3
(6)
LFIX-0084FCZZ
LFIX-0016FCZZ
AD
AC cord holder
-- 6
(7)
-- PSHEP3618FCZZ (Q'ty: 2)
QCNW-0139FCZZ
AN
LCD PWB FG
1st lot '94/10 -- See text 6 Q'ty: 2
51 -131 (8) All 51
(Discontinuance) PBRSR0083FCZZ
-- AH AF
FIN drop sheets Discharge brush Discharge brush
-- 47 PBRSR0141FCZZ
6/7
Current parts Ref. No. Model name Version P/G No. Parts code All 200V series 9 -9 51 50 54 XBBSD40P12000
New parts Parts code XBBSD40P14000 PGSK-0006FCZZ QCNW-0138FCZZ PSHEP3852FCZZ Price rank AA AV AN AC Parts name
Effec- Intertive changetime ability 3 1st lot '94/10
Note
(9)
Screw(M4X14) Gasket Mesh wire FIN paper 1st lot discharge sheets Ferrite core 1st lot '95/4
Q'ty: 6
(10)
(11)
All 200V series AR-5040
Q'ty: 2
(12)
55 -- 1
RCORF1013LCZZ
AN
6 TCAUS0003GCZZ AB Laser warning label 1st lot '95/4 Q'ty: 3
(13) SUK only
48 51 74 35
(14)
TCADZ1216FCZZ CBOX-0100FC31 TLAB-4681CCZZ (Discontinuance)
AP BT --
operation manual Shield box unit Grounding mark label
1st lot '95/2
(15)
All 35 -12 1. Interchangeable. 2. Current type can be used in place of new type. New type cannot be used in place of current type. 3. Current type cannot be used in place of new type. New type can be used in place of current type.
1st lot '95/5
4. Not interchangeable. 5. Interchangeable if replaced with same types of related parts in use. 6. Others.
Parts marked with " ! " is important for maintaining the safety of the set. Be sure to replace these parts with specified ones for maintaining the safety and performance of the set.
7/7