Text preview for : ARE062.PDF part of Sharp AR 5132 Technical report
Back to : Technical report.rar | Home
Date : Dec. 26, 1997
DIGITAL COPIER : AR-5132
No. : ARE-062
1. CHANGE CARRIED OUT IN THE METHOD OF A TTACHMENT OF THE OC A TTACHMENT PLA TE. 2. MEASURE TO ALLEVIA PROBLEMS OF BLURRING OF THE COPY TE IMAGES.
1. Change carried out in the method of attachment of the OC attachment plate.
1.Model Name:
AR-5132
2.General:
Achange has been carried out in the fixing screws and the fixing screw retainer positions. This action has been carried out as a measure to secure and stabilize the OC attachment plate in the optical unit.
Screw retainer (XHBSE40P10000)
OC Attachment plate (The change described above has been carried out in the same way to the OC attachment plate on the left side of the machine.)
3.Action:
From 1997 mid-October production.
1/2
Green C
SHARP CORPORATION
Reprography Division
2. Measure to alleviate problems of blurring of the copy images.
1.Model Name:
AR-5132 (Only for machines of the 200V series)
2.General:
There was a possibility of copy image blurring occurring in the machines of the 200 V series due to a problem in the ICU PWB. As a measure to alleviate this problem, a change has been carried out to a portion of the resistors in the ICU PWB.
[Old] [New] Part code: VRS-TS2AD470J VRS-TS2AD000J Locations where the action described above has been carried out: R830/R831/R832/R833/R834/R835/R836/R837 (Total: 8 locations)
3.Action:
From the 1st lot of 1997 October production.
Current parts Ref. No. Model name Version P/G No. Parts code XBPSD40P06KS0 (Q'ty: 9 5) VRS-TS2AD470J (Q'ty: 12 4)
New parts Parts code XHBSE40P10000 (Q'ty: 4 8) AA VRS-TS2AD000J (Q'ty: 8) Price rank Parts name
Effec- Intertive changeability time Mid'97/10 3 1st lot '97/10
Note
1 AR-5132 2
All
4
Screw (M4 × 6)
200V series 1. Interchangeable.
51 -80
Resistor
4. Not interchangeable. 5. Interchangeable if replaced with same types of related parts in use. 6. Others.
2. Current type can be used in place of new type. New type cannot be used in place of current type. 3. Current type cannot be used in place of new type. New type can be used in place of current type.
Parts marked with `` '' is important for maintaining the safety of the set. Be sure to replace these parts with specified ones for maintaining the safety and performance of the set.