Text preview for : ARE072.PDF part of Sharp AR 5132 Technical report



Back to : Technical report.rar | Home

Date : Jan. 19, 1998
DIGITAL COPIER : AR-5132

No. : ARE-072

MEASURE TO ALLEVIA PROBLEMS OF FUSING JAMS TE DURING DOUBLE SIDE COPY OPERA TIONS.

1.Model Name:

AR-5132

2.General:

There have been problems of jams occurring during double side copy operations using A3 size copy paper in the 200 V series markets. As a measure to alleviate this trouble, the attachment of a duct sheet has been carried out in the ducts of the main body of the machines. In addition, ribs have been designed to attach the duct sheets in the ducts. It is important to note that in the case of machines in the 100 V series markets, the ducts of the main body of the machines in which the ribs have been added are in fact being used, but the duct sheets have not been attached.
The main body duct

The main body duct sheet

3.Action:


Ref. No. Model name

AR-5132 (200 V series): AR-5132 (100 V series):

From the 1st lot of 1997 September production. Running change from 1997 September production.
New parts Parts code PSHEP4505FCZZ Price rank AE Parts name Effec- Intertive changeability time 6 1st lot '97/9 1

Current parts Version P/G No. Parts code 11 ----

Note

Australia U.K. SEEG AR-5132 (200V series) 100V series 1. Interchangeable.

Main body duct sheet

11 -7

PDUC-0100FCZZ

PDUC-0100FCZ1

AV

Duct



3

4. Not interchangeable. 5. Interchangeable if replaced with same types of related parts in use. 6. Others.

2. Current type can be used in place of new type. New type cannot be used in place of current type. 3. Current type cannot be used in place of new type. New type can be used in place of current type.

Parts marked with `` '' is important for maintaining the safety of the set. Be sure to replace these parts with specified ones for maintaining the safety and performance of the set.

SHARP CORPORATION

Reprography Division

Green C