Text preview for : 7050e050.pdf part of konica 7050e 7050e service manual and instructions
Back to : 7050e.zip | Home
5
ADJUSTMENT
5. ADJUSTMENT
[19] Setting Cancellation of HOW TO USE THE ADJUSTMENT MANUAL ..... 5-1 Fixing Abnormality .................................... 5-32 ADJUSTMENTS WHEN REPLACING PARTS .... 5-1 [20] Auto Reset Time ..................................... 5-32 SETTING AND CHECKING WITH THE P [21] Selection of fixing Control During FUNCTION ........................................................... 5-3 Automatic Shut Off ................................... 5-32 [1] List of Confirmation Item by Means of the [22] A3 Copy 2 Counts Setting ...................... 5-33 P Function .................................................. 5-3 [23] Data Control Function Select .................. 5-33 [2] Confirmation and Resetting [24] Setting Auto Button Function of the PM Count ......................................... 5-3 and Auto Condition When Setting [3] Setting the Density Shift ............................. 5-4 ADF Original ............................................. 5-33 [4] Confirmation and Resetting [25] Setting of Behavior When the Key of the Drum Count ...................................... 5-4 Counter is Interrupted Immediately .......... 5-33 [5] Function to Control Data ............................ 5-5 [26] Switching Auto/Manual Priority ............... 5-34 47 Mode and Multi Mode .................................... 5-11 [27] Switching the contents of Normal/Fine ... 5-34 [1] Method of Setting the 47 Mode ............... 5-11 [28] Selecting the Erasing Amount of the [2] Charging Corona Current Adjustment ...... 5-12 Leading Edge in ADF Mode ..................... 5-34 [3] Transfer Current Adjustment .................... 5-12 [29] Setting of Auto Shut Off and Auto [4] Separation (AC) Current Adjustment ....... 5-13 Pre-heating ............................................... 5-35 [5] Separation (DC) Current Adjustment ....... 5-13 [30] Setting Paper Size for Trays 2, 3 and 4 .. 5-35 [6] Charging Grid Voltage Adjustment ........... 5-14 [31] Selecting Outside Erasing the Original ... 5-35 [7] Developing Bais Adjustment .................... 5-15 [32] Toner Level Detecting Select .................. 5-36 [8] Test Pattern Density Adjustment .............. 5-15 [33] Master Key Code Setting ........................ 5-36 [9] Initial Setting ............................................. 5-15 [34] Switching Longitudinal Line Paper/ [10] Adjustment Mode List ............................ 5-16 Transversal Line Paper ............................ 5-36 [11] L Detection Adjustment .......................... 5-16 [35] Selecting Preliminary rotation of [12] Telephone Number Setting ..................... 5-17 Polygon Motor .......................................... 5-36 [13] Input Check List ...................................... 5-18 [36] Selecting the Timing of Polygon Motor [14] Output Check List .................................. 5-20 Low Speed Rotation ................................. 5-36 [15] Adjustment Mode List ............................ 5-23 [37] Selecting Automatic Outside Erasing 25 Mode.............................................................. 5-26 the Original ............................................... 5-37 [1] Settng Method .......................................... 5-26 [38] 25 Mode Address Map ............................ 5-38 [2] E. K. C. Select .......................................... 5-26 [3] FS-103 Sub-tray Select (Printer) .............. 5-26 36 Mode.............................................................. 5-42 [1] Setting Method ......................................... 5-42 [4] ATS Select ............................................... 5-27 [2] Running Test Mode .................................. 5-42 [5] F4 Size Select .......................................... 5-27 [3] Adjusting the Timing of Front Edge .......... 5-43 [6] FS-103 Original Quantity Over Control .... 5-27 [4] Adjustment the Amount of Erasing [7] Temperature Select in the the Front Edge of the Original .................. 5-44 Pre-heat Mode ......................................... 5-28 [5] Horizontal Magnification Adjustment ........ 5-45 [8] Message Language Select ....................... 5-28 [6] Paper Feeding Loop Amount Adjustment 5-45 [9] Priority of the Paper Size ......................... 5-28 [7] Optical Brake Amount Adjustment [10] Jumping Selection of the Paper Size ...... 5-28 (Not Necessary in the Field) ..................... 5-46 [11] Shut-off Time Select [8] Adjustment Centerring Error .................... 5-46 in the Pre-heat Mode ................................ 5-29 [9] List of Mode 36 ......................................... 5-47 [12] FS-102/103 Overload Contraol Select .... 5-29 [13] Setting Intermittent Time for Running Test5-30 35 Mode.............................................................. 5-48 [1] Setting Method ......................................... 5-48 [14] Data Control System Selection ............... 5-30 [2] Adjustment for Centerring error ................ 5-48 [15] ADF Frame Erasing Selection ................ 5-30 [3] List of Mode 35 ......................................... 5-50 [16] PM Cycle Setting .................................... 5-30 [4] Test Pattern of Mode 35 ........................... 5-52 [17] Original Image Shift Setting .................... 5-31 [18] Finisher Initial Mode Setting ................... 5-32 Other adjustment ................................................ 5-70 [1] Adjustment for Centerring error ................ 5-70
ADJUSTMENT
HOW TO USE THE ADJUSTMENT MANUAL
This section details adjusting items and procedures. Use this section for making adjustments and as a checklist before implementing corrective measures in the field. Does the power supply meet the requirements? Is the power supply properly grounded? Is the machine sharing its power source with another high current consumption machine that draws large currents intermittently? (e.g. an elevator, air conditioner, or other source of electrical consumption) 4. Is the installation environment suitable? a.High temperature and high humidity, direct sun light and ventilation. b.Horizontal condition of a place where a machine is installed. 5. Does the cause of a defective image lie in the original itself? 6. Is the density adjusting control at the proper position? 7. Are the platen glass and ADF conveyance belt clean? 8. Is the correct paper being used for the copy? 9. Are the copying materials when they reach the end of their usable life? (developer, drum, cleaning blade, etc.) 10. Is there toner in the machine? The following items should also be observed when repairing the machine. 1. Only one side of the AC power line is disconnected when the main switch of this machine is turned off. Always unplug the machine before beginning work. If absolutely necessary to work with the power on, exercise care to avoid being caught in the scanning rear of the exposure unit. Special care should be taken when handling the fixing unit since it operates at extremely high temperatures. The developing unit is surrounded by a strong magnetic field. Keep watches and metering equipment away from it. Avoid scarring the drum with tools or similar objects. Do not touch IC pins with your bare hands. 1. 2. 3.
ADJUSTMENTS WHEN REPLACING PARTS
Adjustments (including checks) and settings are not only required when a defective copy image occurs, but also after replacing or reinstalling certain parts. [How to Use the Tables] The following items are used in the tables throughout this section.
1. Mode
Indicates the adjustment mode. [47] : 47 mode [25] : 25 mode [36] : 36 mode [35] : 35 mode [ ] : Normal mode
2. Code
It shows a code used in each mode and a copy quantity setting button.
3. VR
· [] None · Indicates the VR number on the CB1 (Main body control board). · Indicates the board name when neither VR or DSW applies.
4. Page
Indicates the page to refer to in the Adjustment section.
5. Conditions
New: Indicates adjustment (including check) is required when replacing a new part. Reset: Indicates adjustment (including check) is required when a part has been re-installed.
2. 3. 4. 5.
6. Symbols used in the tables
1 2 ················· Indicates there is a priority sequence for adjustments (including checks) and settings. Indicates adjustments (including checks) and settings that can be carried out independently.
(Empty circle):
5-1
ADJUSTMENT
C
No.
1
2
3
4
5
6
7
8
9
10
Adjustment the Amount of Erasing the Front Edge of the Original
Adjustment and setting item
Front Edge Timing Adjustment (E-RDH Type)
Front Edge Timing Adjustment (CopyType)
Paper Feeding Loop Amount Adjustment
Setting Paper Size for Tray 2.3 and 4
Horizontal Magnification Adjustment
Charging Grid Voltage Adjustment
Adjustment of Gradation Property 35 80
L Detection Adjustment
Mode Code Page No. 1 2 3 4 5 6 Drum Developer Optics wire Writing unit Memory IC Change of paper size for tray 2.3and4 Part Name Condition New New New Reinstall New Reinstall New -
47
47
36 91
36 98
36 92
36 93
36 94
25 69
47 91
007 095
5-13 5-15 5-39 5-40 5-40 5-41 5-41 5-32 5-63 5-64
1 1
2 2
· New means replace with a new part and reset means to reset the part. · The circles will have a number when there is an adjustment priority.
5-2
Drum counter reset
3
ADJUSTMENT
SETTING AND CHECKING WITH THE P FUNCTION
P function is a function capable of setting and confirming various numerals. With regard to an item to be confirmed, press a number coming under by a copy quantity setting button, while pressing the P button. On a copy number display section or a message display, an set value is displayed. In addition, with regard to an item to be set, see each page coming under.
C
[2] Confirmation and Resetting of the PM Count
1. Confirmation method
Step 1 Operation point Operation (display) While pressing the P button, press P button the copy quantity setting button 5. Copy quantity setting button Confirm the PM count by means of a message display.
[1] List of Confirmation Item by Means of the P Function
There are 6 kinds as follows in the confirmation items by means of the P function. Item Total count Density shift P + 3 Developing count P + 4 PM count P + 5 Drum count P + 7 EKC/data control P + 9
C C
C
2
2. Resetting method
Step 1 Operation (display) While pressing the page quantity buttons 4 and 7, turn ON the main switch. Press "090" by means of the copy quantity setting button. Press a copy button. Input a start date by means of the copy quantity setting button. Press a copy button. Operation point Copy quantity setting button Main switch Copy quantity setting button Copy button Copy quantity setting button Copy button
Operation button P + 1 C
Remarks Resetting impossible Setting possible (See item [3] ) Resetting possible (Set by 4795 mode.) Resetting possible (Set by 4790 mode.) Resetting possible (Set by 4791 mode.) Setting possible (See item [5])
2 3 4 5
5-3
ADJUSTMENT
[3] Setting the Density Shift
1. Setting method
Step 1 Operation point Operation (display) While pressing the P button, press P button the copy quantity setting button 3. Copy quantity setting button Confirm the density shift display (1 to 5) on the message display (see *1). Select a mode by means of a char- Character/photograph button acter/photograph button. Input a density shift number which Copy quantity is requested to change by means setting button of the copy quantity setting button Press F1 in the menu selection Menu selection button button.
C
[4] Confirmation and Resetting of the Drum Count
1. Confirmation method
Step 1 Operation point Operation (display) While pressing the P button, press P button the copy quantity setting button 7. Copy quantity setting button Confirm the PM count by means of a message display.
2
2
3 4
2. Resetting method
Step 1 Operation (display) While pressing the page quantity buttons 4 and 7, turn ON the main switch. Press "091" by means of the copy quantity setting button. Press a copy button. Input a start date by means of the copy quantity setting button. Press a copy button. Operation point Copy quantity setting button Main switch Copy quantity setting button Copy button Copy quantity setting button Copy button
5
2 *1: Relation between the copy quantity setting button and the density shift.
C
Copy quantity setting button 1 2 3 4 5
Density shift Shift to darker 1 Shift to darker 2 Standard Shift to lighter 2 Shift to lighter 1
3 4 5
5-4
ADJUSTMENT
[5] Function to Control Data
In order to utilize data control function, it is necessary to register a master key code in advance. Items capable of being confirmed or installed due to this function are different depending upon installed data in P05, P25 and P52 address in 25 mode.
1. Data control function item
Hereunder, relations between installed data in P05, P25 and P52 address in 25 mode and control item number.
C
25 Mode
Address No. P05 P25 P52
Setting data 0 0 0 0 1 0 0 0 2 2 0 8 [Setting copy quantity [Setting copy quantity limit for each spare parts] limit for each spare parts] Procedure 3 Data list *3 Procedure 3 Data list *3
1
--
--
[Calling copy count limit [Calling copy count limit number for each spare part] number for each spare part] 2 -- -- Procedure 4 Data list *3. Procedure 4 Data list *3.
[Copy quantity count re- [Copy quantity count reset for each spare part] set for each spare part] 3 -- -- Procedure 5 Data list *3. Control item No. Procedure 5 Data list *3.
[Calling copy count for [Calling copy count for [ADF/RDH paper feeding [ADF/RDH paper feeding each size] number counting] number counting] each size] 4 Procedure 1 Data list *1. Procedure 1 Data list *1. Procedure 6 Data list *4. Procedure 6 Data list *4.
5
--
[Copy count reset for each size] [Jamming frequency [Jamming frequency ·All reset counting for each caus- counting for each caus·Individual reset ing point] ing point] Procedure 2 Data list *2. Procedure 7 Data list *5. Procedure 7 Data list *5. [Counting copy quantity for each mode used]
7
--
--
--
Procedure 8 Data list *6. [Counting the number of SC occurrence]
8
--
--
--
Procedure 9 Data list *7.
C
*
5-5
ADJUSTMENT
C
* P05 = 0:EKC is not selected 1:Select the EKC(No stop in limit) 2:Select the EKC(Stop after copy opetation) 3:Select the EKC(Stop immediately) PS25= 0:Ptotection 1:Cancel copy control protection 2:Cancel service control protection PS52= 0:No function 1:Cancel protection
5-6
ADJUSTMENT
2. Operation procedure
Step 1 Operation (display) While pressing the P button, press the copy quantity setting button 9. Operation point P button Copy quantity setting button
2
Input a master key code (8 digits).
Copy quantity setting button
3
Input a control item No. (*)
Copy quantity setting button
C
4 5
Press the copy button. (*) (*) In the case of Procedure 1 4 6 7 8 and 9
Copy button
C
5-1 Select an item.
Reduction/magnification button
C
In the case of
Procedure 5 Reduction/magnification button Copy button
C
5-1 Select a counter number. 5-2 Press the copy button.
C
C
In the case of 5-1 Select an item.
Procedure 3 Reduction/magnification button Copy quantity setting button Copy button
C
5-2 Set limit number. 5-3 Press the copy button.
C
C
In the case of
Procedure 2 (All reset) Copy button
5-1 Press the copy button. In the case of Procedure 2 (Individual reset)
5-1 Press the stop/clear button. 5-2 Select a counter number. 5-3 Press the copy button.
Stop/Clear button Reduction/Magnification button Copy button
6 7
Press the stop/clear button. (*) While pressing the P button, press the stop/clear button and return to the normal mode.
Stop/Clear button P button Stop/Clear button
* : Repeat procedures 3 through 6 if necessary.
5-7
ADJUSTMENT
Data List * 1
C
Calling copy count for each size Paper size -- A3 B4 A4 B5 A5 B6 8.5" × 14" 8.5" × 11" By-pass feed
C
Data List * 4 No. 1 2 3 4
Counting the number of ADF paper feeding Paper feed mode ADF/RDH RADF/RRDH -- --
No. 1 2 3 4 5 6 7 8 9 10 Data List * 2 No. 1 2 3 4 5 6 7 8 9 10
Data List * 5 No. 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24
Counting the frequency of jamming for each causing point No. 25 26 27 28 29 30 31 32 33 34 35 36 37 38 39 40 41 42 43 44 45 46 47 48 Jamming J12-1 J12-2 J12-3 J12-4 J13-1 J13-2 J13-3 J13-4 J14-1 J14-2 J14-3 J14-4 J30 J74 J95 J96 J10-2 J10-4 J17-1 J17-2 J17-3 J17-4 J17-5 J17-6
Copy count reset (individual reset) for each size Paper size -- A3 B4 A4 B5 A5 B6 8.5" × 14" 8.5" × 11" By-pass feed
Data List * 3
Copy quantity limit setting for each spare part Copy quantity count calling for each spare part Copy quantity count resetting for each spare part
Paper size Counting copy frequency. Counting frequency of manual paper feeding copy. Counting frequency of the main body upper step paper feeding. Counting frequency of the main body lower step 23 paper feeding. Counting frequency of the LCT upper step paper 24 feeding. Counting frequency of the LCT lower step paper 25 feeding. Counting copy frequency of the ADU paper feeding. 26 Counting copy frequency of the main body paper 27 ejecting. 28~30 Counting frequency of ADU paper feeding.
No. 1~20 21 22
Jamming J10 J11 J12 J13 J14 J16 J17 J19 J21 J31 J32 J61 J62 J63 J72 J75 J92 J93 J94 J11-1 J11-2 J11-3 J11-4
Note: The same codes apper on different area. (ex:J11 and J11-1 to 4)
5-8
ADJUSTMENT
Data List * 6 No. 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36 37 38 39 40 41 42 43 44 45
Counting copying number for each mode used No. 46 47 48 49 50 51 52 53 54 55 56 57 58 59 60 61 62 Copy mode Copy quantity in an photographic mode. Quantity of paper feeding in a DF thick paper. Frequency of using a lengthwise/widthwise magnification change mode. Frequency of using a book memory. Frequency of using a single step. Frequency of using a character/photograph mode. Frequency of using a character mode. Frequency of using an arbitrary density. Frequency of using an OHP mode 2. Frequency of using an intersheet 3. Frequency of using an intersheet 4. Frequency of using an inserted page. Frequency of using a chapter control. Frequency of using a compound copy. Frequency of using a repeat copy Frequency of using a black and white reversing. Frequency of using a outside document.
Copy mode Copy quantity in "one sideone side" mode. Copy quantity in "one sideboth side" mode. Copy quantity in "both sidesone side" mode. Copy quantity in "both sidesboth side" mode. Copy quantity from one side to one side when using the ADF. Copy quantity from one side to both sides when using the ADF. Copy quantity in a staple sort mode. Copy quantity in a sort mode. Copy quantity in a group mode. Frequency of staple. Copy quantity in the same magnification. Copy quantity in a fixed magnification of 1.41/2.00. Copy quantity in a fixed magnification of 1.22/1.55. Copy quantity in a fixed magnification of 1.15/1.29. Copy quantity in a fixed magnification of 0.86/0.77. Copy quantity in a fixed magnification of 0.82/0.65. Copy quantity in a fixed magnification of 0.71/0.50. Copy quantity in an arbitrary magnification. Copy quantity in a zoom magnification. Copy quantity in the maximum magnification of 2.00. Copy quantity in the minimum magnification of 0.50. Copy quantity in the AMS mode. Copy quantity in the APS mode. Copy quantity in the EE mode. Copy quantity in the interruption mode. Copy quantity in the manual feeding mode. Copy quantity in the page continuous copying mode. Copy quantity in the frame erasure mode. Copy quantity in the folding erasure mode. Copy quantity in the same magnification image shift mode. Copy quantity in the reduction magnification image shift mode. Copy quantity in a thick paper mode. Copy quantity in a thin paper mode. Copy quantity in an inter-sheet 1. Copy quantity in an inter-sheet 2. Copy quantity in an OHP mode. Copy quantity in a mixed mode. Reading frequency of a job memory. Frequency of utilizing a pre-heating mode. Copy start frequency when a set quantity is 1. Copy start frequency when a set quantity is 2 to 5. Copy start frequency when a set quantity is 6 to 10. Copy start frequency when a set quantity is 11 or more. Copy start frequency in inter-sheet 1. Copy start frequency in inter-sheet 2.
5-9
ADJUSTMENT
Data List * 7
C
Counting frequency of the occurrence of SC No. 36 37 38 39 40 41 42 43 44 45 46 47 48 49 50 51 52 53 54 55 56 57 58 59 60 61 62 63 64 65 66 67 68 69 70 F/E code F22-2 F28-3 F43-1 F43-2 F43-3 F43-4 F51-1 F51-2 F51-3 F51-4 F51-5 F51-6 F51-7 F51-8 F51-9 F52-1 F52-2 F52-3 F52-4 F52-5 F52-6 F52-7 -
No. 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35
F/E code F18-1 F18-2 F18-3 F18-4 F28-1 F28-2 F34-1 F34-2 F35-1 F35-2 F36-1 F36-2 F41-4 F22-1
5 - 10
ADJUSTMENT
47 MODE AND MULTI MODE
[1] Method of Setting the 47 Mode
1. 47 Mode
This machine is provided with a 47 mode (Input/Output check function) as a self diagnosis function and various adjustments are possible in this mode.
2. Multi Mode
A Multi mode is provided in the 47 mode function of this machine. Multiple input/output checks are possible with one I/O check code. · An M mark is indicated in the Multi Code column of the I/O Check Code list after the functions that the multi mode can use. Setting method a. Set to the 47 mode. b. Enter the object I/O check code (those with multi mode functions) with the copy quantity setting button. c. Press the P button. d. The standard mode of the multi mode flashes in the copy quantity display section. e. Enter the object multi mode No. (see Multi Mode list) with the copy quantity setting button. f. The multi mode No. displayed in the copy quantity display section flashes. g. Press P button (indication changes to 47 mode's). h. Carry out in the same manner as I/O check of the 47 mode after setting the multi mode. (1) Input check The input signal level preset in the multi mode is displayed as [Hi] or [Lo] on the magnification display section. (2) Output check Pressing the Copy button causes the copier to operate with load preset in the multi mode, whereas pressing the Stop/Clear button stops this operation. i. The 47 multi mode will be cleared when the main switch is set to OFF.
Setting method Step 1 Operation While pressing the copy quantity buttons 4 and 7, turn ON the main switch. Input an address No. by means of the copy quantity button. Remarks (status) Selecting Mode 47.
C
2
3 4 5 6
7 8
Address number is lit. Check inputting by means of H and L display. Press a copy button so that let Output check. move various loads. Press the stop/clear button so that Output stop. stop the movement of the load. Press a P button. (*1) Flickering of data display. Input modified data by means of Flickering of the copy quantity setting button. the inputted data, modifica(*1) tion of data is completed. Flickering of the Press the P button. (*1) data display. Turn the main switch from OFF to Return to the normal mode. ON.
*1: Procedures 5 to 7 are effective only for address numbers wherein data can be modified.
5 - 11
ADJUSTMENT
C
[2] Charging Corona Current Adjustment
(Not applicable in field)
C
[3] Transfer Current Adjustment
(Not applicable in field)
5 - 12
ADJUSTMENT
C
[4] Separation (AC) Current Adjustment
(Not applicable in field)
C
[5] Separation (DC) Current Adjustment
(Not applicable in field)
5 - 13
ADJUSTMENT
[6] Charging Grid Voltage Adjustment
1. Setting method
C
Step 1
2
3
4
5
6 7
Operation (display) Check the standerd value of the grid voltage written at the drum frange. Connect the tester as shown below. + Grid pin GND(Earth) Range DC1000V While pressing the page quantity buttons 4 and 7, turn ON the main switch. Press "007" by means of the copy quantity setting button. Confirm that the copy quantity display portion displays "7". Press the copy button and check the tester value. Then, stop by the stop button. If the adjustment is necessary, comply with the following procedure. Press P button. On the copy quantity display portion, the level of the existing installed value is flickered. Variable range for the installed value : 0 ~ 255 Standard value (targeted) : 137
Operation point
Copy quantity setting button Main switch Copy quantity setting button
Copy button stop button
P button
8
9 10
Variable amount by one step : about 1.6 µA Input an installed value which is Copy quantity requested to be modified by means setting button of the copy quantity setting button. P button Press a P button. Repeat the step from 5 to 9 until the adjustment completes.
5 - 14
ADJUSTMENT
C
[7] Developing Bais Adjustment
(Not applicable in field)
[8] Test Pattern Density Adjustment
1. Setting method
Step 1 Operation (display) While pressing the page quantity buttons 4 and 7, turn ON the main switch. Press "013" by means of the copy quantity setting button. Confirm that the copy quantity display portion displays "13". Press a P button. On the copy quantity display portion, the level of the existing installed value is flickered. Variable range for the installed value : 0 ~ 255 Note: The adjustment is density set of test pattern for Overall halftone (35-01 mode). The density have three position for 0, 70 and 255. Input an installed value which is Copy quantity requested to be modified by means setting button of the copy quantity setting button. P button Press a P button. Operation point Copy quantity setting button Main switch Copy quantity setting button
2
3 4
P button
5
6
C
Note: After completing test pattern output, restore the value to 255.
[9] Initial Setting
· Each adjustment data is totally returned to the data value when the machine is delivered from a factory.
1. Setting method
Step 1 Operation (display) While pressing the page quantity buttons 4 and 7, turn ON the main switch. Press "093" by means of the copy quantity setting button. Confirm that the copy quantity display portion displays "93". Press a copy button. Operation point Copy quantity setting button Main switch Copy quantity setting button
2
3
Copy button
5 - 15
ADJUSTMENT
[10] Adjustment Mode List
· It can grasp all adjustment modes of the machine. · However, adjustment (change of data value) due to this mode cannot be conducted.
[11] L Detection Adjustment
· It adjusts automatically by sensing toner density. · Conduct this adjustment in installing the main body and replacing a developing agent. Note: If developer that is being used is adjusted, the toner density of the developer in use will become the reference, resulting in an incorrect adjustment value.
1. Setting method
Step 1 Operation (display) While pressing the page quantity buttons 4 and 7, turn ON the main switch. Press "094" by means of the copy quantity setting button. Confirm that the copy quantity display portion displays "94". Press a copy button. An item and data are displayed on the message display. Due to a reduction/magnification button (/), an item displayed is shifted one by one (*1). Operation point Copy quantity setting button Main switch Copy quantity setting button
1. Setting method
Step 1 Operation (display) While pressing the page quantity buttons 4 and 7, turn ON the main switch. Press "095" by means of the copy quantity setting button. Confirm that the copy quantity display portion displays "95". Press a copy button. · A stirring screw in a developing unit rotates, and L sensing sensor is automatically read. · After about 5 minutes, sensing automatically stops. [ADJ OK] is displayed on the message display in the operation unit. Operation point Copy quantity setting button Main switch Copy quantity setting button
2
2 Copy button
3
4
Reduction/magnification button
3
Copy button
*1: See [15] list of adjustment modes (pp. 5 -20) for the content displayed.
5 - 16
ADJUSTMENT
[12] Telephone Number Setting
· The setting is registration for telephone number. The telephone number is displayed on the message display for generation service call.
1. Setting method
Step 1 Operation (display) While pressing the page quantity buttons 4 and 7, turn ON the main switch. Press "180" by means of the copy quantity setting button. Press a copy button. Hereunder, that is displayed on the message display in the operation unit. Operation point Copy quantity setting button Main switch Copy quantity setting button Copy button
2 3
4
C
5 6
TEL NO. XXX-XXX-XXXX Press "Telephone Number" by means of the copy quantity setting button. *"-"appears by pressing P button Press a set/F1 button. Press a stop/clear button.
Copy quantity setting button Copy button Set/F1 button Stop/Clear button
5 - 17
ADJUSTMENT
[13] Input Check List
Classification Code 000 001 002 003 004 005 006 007 008 009 010 012 Paper feed 016 Symbol DCPS2 TLD TH1 TH2 Multi mode Name CVR FB signal Toner level detecting signal Internal temperature detecting signal TH1 signal TH2 signal Humidity sensor signal Dmax MONI signal Dmax signal Drum jamming signal No-paper detecting signal Tray upper limit detecting Paper size signal A3:7, B4:6, A4R:8, A4:5, B5R:C, B5:1, B6:9 Pre-try detecting State of display and signal source L H Normal Abnormal Enough toner Less toner C C * * C * C * C C * * C * C * * * C * No paper OFF
C
C
C
Analog signal
C
TCSB TCSB TCSB
PS12,13,15, 141,140 PS16,17, 143,142
C
M M M
C -Common to 10, 12,16 and 191: Resist PS 2: No feed PS 3: LCT right 4: LCT left -Only to 105: By-pass feed
* * C * Paper ON
C
C
C
019
PS20,21,210, 200
C
M
OFF
ON
020 Paper feed and conveyance
022
PS14 PS18 PS19 PS401 PS407 PS25
C
M
023
PS11 PS160 PS158 PS24
C
M
Optics
030
PS7 PS3 PS5 PS4 PS45 PS2 PS1
M
Paper feed sensor signal C 1: Resist PS 2: No feed PS C 3: Optical synchronization sensor C 4: LCT pass detect sensor C 5: LCT feed detect sensor Paper exit sensor signal Interlock signals 1: Right side plate 2: LCT right side plate 3: Left side plate 4: Sensing whether or not the fixing lever is closed Optics sensor signals 1: OPT TMG 2: Shading 3: Return 4: Resist 5: APS timing 2 6: Center sensor 7: Over run Main body ROM version 1: C1 ROM 2: C2 ROM 3: C3 ROM 4: C4 ROM
OFF
ON
ON
OFF
OFF
ON
OFF
ON
M 048
Main body M 049 Processing ROM version 1: I1 ROM 2: I2 ROM
5 - 18
ADJUSTMENT
Classification Code
Symbol
Multi mode
Name
State of display and signal source L H
C
Peculiar function
050
M
Checking whether or not a connector is connected 1: A/D board connection (CN420) 2: LD1 board connection (CN421) 3: LD2 board connection (CN422) 4: INDEX board connection (CN423) 5: Sub scanning correction motor connection (CN424) 6: Scanner I/F board connection (CN426) 7: CFF I/F board connection (CN427) 8: Electronic RDH board connection (CN428) 9: Printer I/F board connection (CN429)
Connect
Notconnect
C
060
MS301 MS302
M
Interlock signals C 1: ADF open/close interlock 2: Reversal portion interlock
C
C
OPEN
CLOSE
ADF and RADF
C
064
MS302
M
DF306 1: No paper detecting
C
C
PAPER
NO PAPER
069
M
Signal for connect ADF 1: DF306
C
C
ADF
NO ADF
C
Sorter and Finisher
079
M
Signal for connect Finisher 1: FS-102
C
C
FS
NO FS
080
PS158
Interlock signal
OFF
ON
C
C
ADU
082
PS152 PS153 PS157 PS155 PS156 PS151
M
Paper detecting signal 1: ADU Paper feed 2: ADU reversal detection 3: ADU gate 4: ADU paper exit 2 5: ADU paper exit 3 6: ADU no paper
OFF
ON
089
Signal for connect ADU
ON
OFF
5 - 19
ADJUSTMENT
[14] Output Check List
Classification Code 000 001 002 003 004 005 006 007 008 009 010 011 012 013 014 015 016 017 018 019 Symbol L1 M10 HV1 HV2 HV2 HV2 HV2 HV1 Multi mode Name Exposure lamp Toner supply motor Charging Transfer Separation (AC) Transfer + Separation (AC + DC) Separation (DC) Grid Dmax / LED JAM detecting LED Guide plate bias Test pattern density correction level adjustment Impossible to install/ change to write in the field
C
M M M M M
Analog signal
×
HV1 HV1
M M
× × ×
Temporary
L detecting reference data Dmax level adjustment 1st paper feed solenoid 1: Main body upper 3: LCT right (1000) 5: By-pass feed
020
M
2: Main body lower 4: LCT left (1500)
021
M
Paper feed
022
M
Paper feed motor 1: High speed in the main body (paper feeding speed in the main body) 2: Low speed in the main body (by-pass feeding speed) 3: LCT 1st paper feed clutch 1: Main body upper 2: Main body lower 3: LCT right (1000) 4: LCT left (1500) 5: By-pass feed
023
Optics
024 025 029 030 031 032 033 034 035 036 037 038 039
MC8 MC3 SD4 M12 M5
Intermediate conveyance clutch 2nd paper feed clutch Separation claw solenoid Optical return trip driving Polygon motor Polygon motor + APC Shading correction + AGC + AOC Platen EE operation C Laser 1 PWM Laser 2 PWM Correction of sub-scanning beam
C C
M M
× × ×
5 - 20
ADJUSTMENT
Classification Code 040 041
Symbol M1 M4
Multi mode
Name Main motor Drum motor Fan motor 1: Main fan 2: Optical fan 3: Suction fan 4: Image processing fan 5: Electronic RDH fan 6: ADU fan 7: Developing fan Total counter Charge cleaning motor Transfer/ Separation cleaning motor (continuous) Fixing heater lamp 1: Thin paper mode 2: Standard mode 3: Thick paper mode Charge cleaning motor Transfer/Separation cleaning motor/separation cleaning motor Operation unit (all are lit) Buzzer Setting the rotation number of the developing driving motor in 400 dpi PCL TSL C Developing screw motor Toner automatic replenishing (L detecting) Message test Compulsory returning the charge cleaning motor Compulsory returning the transfer/separation cleaning motor Drive (DF306) 1: Conveyance belt (forward) 2: Conveyance belt (backward) Switch (DF 306) 1: Paper feeding plate solenoid 2: Paper feeding solenoid 3: Reversing solenoid 4: Swing back solenoid 5: Speed reduction paper exiting solenoid Test mode 1: One side document continuously 2: One side document one by one 3: Both side document continuously 4: Both side document one by one ADU paper feed motor ADU load 1: CW clutch 2: CCW clutch 3: Conveyance clutch 4: Longitudinal conveyance solenoid PM counter clear Process counter clear 1: Drum counter Process initial setting (impossible to be used in the fild) Fild initial setting (data return in delivery from process) Adjustment mode list display mode* L-detecting reference value automatic adjustment (Developing counter reset) Process delivery completing setting (Used in product line) Lighting adjustment 1: Mode 1 2: Mode 2 Data inputting about transcription and separated humidity Unvolatile reference mode
Impossible to install/ change to write in the market ×
042
M
Main body
043 044 045 046 047 048 049 050 051 052 053 054 055 056 057 060
C(T) M7,M8 L2,L3 M7 M8 M
C
M3 PCL TSL M35 M10 M7 M8 M
×
Intrinsic function
C
064 RADF
M
069
M
080 ADU 084
M151 M
Adjustment process and others
090 091 092 093 094 095 096 097 098 099
M M M
×
× × ×
5 - 21
ADJUSTMENT
Classification Code 103 104 106 107 111 120 136 137 140 150 160 180 190 191 192 193 197 198 199
Symbol HV2 HV2 HV2 HV1 HV1
Multi mode
C
Name Transfer Separation (AC) Separation (DC) Grid Bias 600dpi Non-volatile RAM data setting Laser 1 PWM Laser 2 PWM Main motor speed Setting the rotation number of the developing driving motor in 600 dpi Setting pass word of the weekly timer Telephone number setting AGC setting AOC setting Setting a targeted value of white correction Setting a targeted value of black correction Checking the SIMM volume of the electronic RDH
C
600dpi mode
C
Impossible to install/ change to write in the market × × × × × × × ×
M1 M3
C
Special mode
C
× × × × × ×
C
Setting offset quantity for correcting sub-scanning slip
5 - 22
ADJUSTMENT
[15] Adjustment Mode List
Contents of adjustment 1. Charge current 2. Transfer current 3. Separation (AC) current 4. Separation (DC) current 5. Grid voltage 6. Developing bias 7. Transfer current (600dpi) 8. Separation (AC) current (600dpi) 9. Separation (DC) current (600dpi) 10. Grid voltage (600dpi) 11. Developing bias (600dpi) 12. Adjusting Dmax level 13. Laser 1 PWM (600dpi) 14. Laser 2 PWM (600dpi) 15. Laser 1 PWM (600dpi) 16. Laser 2 PWM (600dpi) 17. LD1 offset adjustment (400dpi) 18. LD2 offset adjustment (400dpi) 19. LD1 offset adjustment (600dpi) 20. LD2 offset adjustment (600dpi) 21. Separation claw ON 22. Separation claw OFF 23. Adjustment one-sided 24. SGU adjustment onesided (table) Contents of message 1st line CHARGE (1) ADJ TRANSFER (1) ADJ SEPARAT (AC) (1) ADJ SEPARAT (DC) (1) ADJ GRID (1) ADJ BIAS (1) ADJ TRANSFER (2) ADJ SEPARAT (AC) (2) ADJ SEPARAT (DC) (2) ADJ GRID (2) ADJ BIAS (2) ADJ Dmax ADJ LD1 POWER (1) LD2 POWER (1) LD1 POWER (2) LD2 POWER (2) LD1 OFFSET (1) LD2 OFFSET (1) LD1 OFFSET (2) LD2 OFFSET (2) SEPARATOR CLAW ON SEPARATOR CLAW OFF LD CENTERING (1) ADJ LD CENTERING (2) ADJ 2nd line 47-002+P 47-003+P 47-004+P 47-006+P 47-007+P 47-011+P 47-103+P 47-104+P 47-106+P 47-107+P 47-111+P 47-018+P 47-036+P 47-037+P 47-136+P 47-137+P 35-005+P+3 35-005+P+4 35-005+P+7 35-005+P+8 25-01+P 25-02+P 36-097+P 35-016+P
C
C
Impossible to Data from 47-92 mode Range of data be adjusted
C
Data (referential value)
145 -
0~255 0~255 0~255 0~255 0~255 0~255 0~255 0~255 0~255
C
× × × ×
C
C
C
C
C
C
C
C
C
× × × × × × × × × × ×
C
50 92 92 20 20 20 20 1 6 0 0
0~255 0~255 0~255 0~99 0~99 0~99 0~99 -64~+64 -64~+64 -64~+64 -64~+64 0~9 0~9 -32~+32 -32~+32
C
C
C
× × × ×
5 - 23
ADJUSTMENT
Contents of adjustment 25. A5R backside is onesided 26. Front edge timing (Copy: first copy) 27. Front edge timing (ERDH: second copy) 28. Front edge timing (printer) 29. Erased amount of the front edge of document 30. Horizontal magnification adjustment 31. SGU longitudinal magnification adjustment 32. Adjustment of loop amount of paper feeding (Tray) 33. Adjustment of loop amount of paper feeding (By-pass) 34. Adjustment of optical brake amount 35. Rotation number of developing motor 36. Rotation number of developing motor (600dpi) 37. Absolute position of laser 1 38. Absolute position of laser 2 39. Sub-scanning slip amount 40. Main-scanning slip amount 41. AOC1 data 42. AOC2 data 43. AGC1 data 44. AGC2 data 45. Copy quantity in tray-1 46. Copy quantity in tray-2 47. Copy quantity in tray-3 48. Copy quantity in tray-4
Contents of message 1st line CENTERING (A5R) ADJ RESISTRATION (2) RESISTRATION (1) RESISTRATION (3) IMAGE MISSING ADJ MAGNIFI (1) ADJ MAGNIFI (2) ADJ LOOP ADJUST (TRAY) LOOP ADJUST (BYPASS) BREAK ADJUST DEVELOPING MOTOR (1) DEVELOPING MOTOR (2) LD1 POSITION LD2 POSITION VERTICAL SHIFT HORIZONTAL SHIFT AOC CH1 Vol. AOC CH2 Vol. AGC CH1 Vol. AGC CH2 Vol. TRAY-1 TRAY-2 TRAY-3 TRAY-4 C C
C
2nd line 35-80(P+2) 36-091+P 36-098+P 36-099+P 36-092+P 36-093+P 35-016+P+2 36-094+P 36-094+P 36-096+P 47-050+P 47-150+P -
Impossible to Data from 47-92 mode Range of data be adjusted 0
C
Data (referential value)
+24 +29 +51 +28 -20 16
C
C
-94~+99 (-99~+99) -100~+99 (-99~+99) -100~+99 (-99~+99) -99~+99 0~99 -20~+20 -1~31 -20~+90 -20~+90 0~9 (-9~+9) 1~32 1~32
C
×
C
C
C
+10 +60 7
C
C
00998 01060 62 00524 68 84 44 45 0 0 0 0
× ×
C
C
C
C
× × × × × × × ×
C
35-80+P+5 35-80+P+5 -
C
C
C
C
C
C
C
0~999999 0~999999 0~999999 0~999999
5 - 24
ADJUSTMENT
Contents of adjustment 49. By-pass feed copy quantity 50. ADU copy quantity 51. Dmax error (1) 52. Dmax error (2) 53. Dmax error (3) 54. Gamma error (1) 55. Gamma error (2)
Contents of message 1st line COPY COUNT(BYPASS) COPY COUNT(ADU) D-MAX ERROR(1) D-MAX ERROR(2) D-MAX ERROR(3) GAMMA ERROR(1) GAMMA ERROR(2) 2nd line -
Impossible to Data from 47-92 mode Range of data be adjusted 0 0 0 0 0 0 0 0~999999 0~999999 0~255 0~255 0~255 0~255 0~255
Data (referential value)
5 - 25
ADJUSTMENT
25 MODE
This machine is provided with the 25 mode as an adjusting method to enable various adjustments.
[2] E. K. C. Select
Select an E.K.C. mode and set behavior in limit.
[1] Settng Method
Step 1 Operation While pressing the page quantity buttons 2 and 5, turn ON the main switch. Due to a reduction/magnification button (/), select an address No. Or, directly input by the following procedure. Remarks (status) Selecting Mode 25. Address number is lit. Step 1 Operation (display) Set to the 25 mode. Operation point Copy quantity setting button Main switch Magnification/ reduction button or the P button + the copy quantity setting button. Copy quantity setting button
2
Designate Address P05.
2
3 2-1 Press a P button. (*1) 2-2 By means of the copy quantity setting button, input the address No. (*1) 2-3 Press a P button. (*1) 3 4 Input modified data by means of Data modificathe copy quantity setting button. tion. Press a copy button. Data modification is completed. Turn the main switch from OFF to Return to the ON. normal mode.
4
Modify data. 0: E.K.C. is not selected. 1: Select the E.K.C. (No stop in limit.) 3: Select the E.K.C. (Stop after copy in limit.) 5: Select the E.K.C. (Immediate stop in limit.) Press a copy button.
Copy button
5
C
[3] FS-103 Sub-tray Select (Printer)
Set if FS-103 sub-tray is used and paper exit direction. Step Operation (display) 1 Set to the 25 mode. Operation point Copy quantity setting button Main switch Magnification/ reduction button or the P button + the copy quantity setting button. Copy quantity setting button
*1: Address No. is possible to be directly inputted by means of procedures 2-1 through 2-3.
2
Designate Address P07.
3
Modify data. 0: Sub-tray is not used. 2: Sub-tray is used. (Reverse paper exit) 3: Sub-tray is used. (Normal paper exit)
4
Turn ON the copy button.
Copy button
5 - 26
ADJUSTMENT
[4] ATS Select
Set objective trays for ATS. Step 1 Operation (display) Set to the 25 mode. Operation point Copy quantity setting button Main switch Magnification/ reduction button or the P button + the copy quantity setting button. Copy quantity setting button
1
[6] FS-103 Original Quantity Over Control
Set the operation used when the original quantity exceeds the specified limit.
Step Operation (display) 1 Set to the 25 mode.
2
Designate Address P08.
2
Designate Address P11.
3
4
Modify data. 0: ATS is not conducted. 1: ATS is possible for all steps. 2: ATS is not possible only for the upper step. Copy button Press a copy button.
3 4
*1 Data 0 1 2 3 4 5 6 7 8 9
Modify data. 0~9 (*1) Turn ON the copy button.
Operation point Copy quantity setting button Main switch Magnification/ reduction button or the P button + the copy quantity setting button. Copy quantity setting button Copy button
[5] F4 Size Select
Select F4 size paper. Step 1 Operation (display) Set to the 25 mode. Operation point Copy quantity setting button Main switch Magnification/ reduction button or the P button + the copy quantity setting button. Copy quantity setting button
Modification Stops immediately (at max.50 sheets) Stops immediately (at max.45 sheets) Stops immediately (at max.40 sheets) Stops immediately (at max.35 sheets) Stops immediately (at max.50 sheets) Stop when current set of copy completes. (every 50 sheets) Stop when current set of copy completes. (every 45 sheets) Stop when current set of copy completes. (every 40 sheets) Stop when current set of copy completes. (every 35 sheets) Stop when current set of copy completes. (every 50 sheets)
2
Designate Address P10.
3
4
Modify data. 0: 8.5×13 1: 8.25×13 2: 8.125×13.25 3: 8×13 Press a copy button.
Copy button
5 - 27
ADJUSTMENT
[7] Temperature Select in the Pre-heat Mode
Select fixing temperature in the pre-heat mode. Step 1 Operation (display) Set to the 25 mode. Operation point Copy quantity setting button Main switch Magnification/ reduction button or the P button + the copy quantity setting button. Copy quantity setting button
[9] Priority of the Paper Size
Set the most priority paper size selected when auto-function operates. (When APS released) Step 1 Operation (display) Set to the 25 mode. Operation point Copy quantity setting button Main switch Magnification/ reduction button or the P button + the copy quantity setting button. Copy quantity setting button
2
Designate Address P12.
2
Designate Address P16.
3
Modify data. 0: 160°C 1: 170°C 2: 180°C Press a copy button.
3
4
Copy button 4
Modify data. 0: A3 5: 1: A4 6: 2: A4R 7: 3: A5 8: 4: OTHERS Press a copy button.
F4 B5R B5 B4
Copy button
[8] Message Language Select
Select message language on operation unit. Step 1 Operation (display) Set to the 25 mode. Operation point Copy quantity setting button Main switch Magnification/ reduction button or the P button + the copy quantity setting button. Copy quantity setting button
[10] Jumping Selection of the Paper Size
Select the most preferred paper size in temporary. (Select by using P+cassette size button) Step 1 Operation (display) Set to the 25 mode. Operation point Copy quantity setting button Main switch Magnification/ reduction button or the P button + the copy quantity setting button. Copy quantity setting button
2
Designate Address P14.
2
Designate Address P17.
3
4
Modify data. 0: English 1: French 2: German 3: Italian Press a copy button.
3
Copy button 4
Modify data. 0: A3 5: 1: A4 6: 2: A4R 7: 3: A5 8: 4: OTHERS Press a copy button.
F4 B5R B5 B4
Copy button
5 - 28
ADJUSTMENT
[11] Shut-off Time Selection in the Pre-heat Mode
Select shut-off time in the pre-heat mode. Step Operation (display) 1 Set to the 25 mode. Operation point Copy quantity setting button Main switch Magnification/ reduction button or the P button + the copy quantity setting button. Copy quantity setting button
*1
Operation
Data
0~3 6~9
4
5
2
Designate Address P19.
Performing lower limit detection by PS3(Tray lower limit) Detecting PS7(Staple paper exit upper limit) abnormal ON by exiting paper(More than 1sec) Detecting PS2(tray upper limit) abnormal ON by exiting paper. Stop at predetermined number of copies.(*2)
*2 Non-staple mode Group mode Offset mode Paper size B6R,A5R,5.5×8.5R B5R,B5,A4R,A4 8.5×11R,8.5×11 B4R,F4R,A3R 8.5×14R,11×17R Staple mode
3
Modify data. 0~3: 1 hour 4~6: 2 hour 7~9: 3 hour Press a copy button.
4
Copy button
capacity (the number of sheets) 500 2,000 1,500
1
[12] FS-102/103 Overload Control Select
Set the operation for an overload when a finisher is used. Step Operation (display) 1 Set to the 25 mode. Operation point Copy quantity setting button Main switch Magnification/ reduction button or the P button + the copy quantity setting button. Copy quantity setting button
The number of sheets 2~9 10~20 21~30 31~40 41~50
2
Designate Address P20.
A3, 11x17 excluded 1 staple 2 staple place places 100 sets 100 sets 50 sets 50 sets 30 sets 30 sets 25 sets 25 sets 20 sets 20 sets
A3, 11x17 1 staple 2 staple place place 100 sets 50 sets 20 sets 15 sets 30 sets 30 sets 25 sets 25 sets 20 sets 20 sets
3
4
Modifies data 0:Not control overload 5:Stops when paper quantity exceeds the specification or more than 25 copies are stapled. 0-9 (refer to *1) Turn ON the copy button.
Copy button
5 - 29
ADJUSTMENT
[13] Setting Intermittent Time for Running Test
In order to conduct intermittent copy in running test mode in Mode 36, set waiting time. Step 1 Operation point Copy quantity setting button Main switch Designate address of waiting time. Magnification/ reduction button P22: 3rd digit (102) or the P button + P23: 2nd digit (101) the copy quanP24: 1st digit (100) tity setting button. Copy quantity Input waiting time . setting button (1 second to 255 seconds) Copy button Press a copy button. Operation (display) Set to the 25 mode.
[15] ADF Frame Erasing Selection
Set frame erasing of ADF. Step 1 Operation (display) Set to the 25 mode. Operation point Copy quantity setting button Main switch Magnification/ reduction button or the P button + the copy quantity setting button. Copy quantity setting button Copy button
2
Designate Address P26.
2
3
3 4 *
4
Modify data. 0: No 5: Yes Press a copy button.
*
Waiting time is possible to be set in a range from 1 second to 255 seconds. When more than 255 is inputted, 255 seconds is automatically set. Addresses P22, P23 and P24 respectively input data by means of procedure 2 to 4.
[16] PM Cycle Setting
Set a cycle for displaying PM's status. Step 1 Operation point Copy quantity setting button Main switch Designate address of waiting time. Magnification/ reduction button P27: 5th digit (104) or the P button + P28: 4th digit (103) the copy quanP29: 3rd digit (102) tity setting button. Copy quantity Input PM cycle . setting button Copy button Press a copy button. Operation (display) Set to the 25 mode.
[14] Data Control System Selection
Set the protect for copy control and service control operator mode. Step 1 Operation (display) Set to the 25 mode. Operation point Copy quantity setting button Main switch Magnification/ reduction button or the P button + the copy quantity setting button. Copy quantity setting button 2
2
Designate Address P25.
3 4 *
Addresses P27, P28 and P29 respectively input data by means of Procedure 2 to 4.
3
4
Modify data. 0: Protect 1: Cancel copy control protect 2: Cancel service control protect Copy button Press a copy button.
5 - 30
ADJUSTMENT
[17] Original Image Shift Setting
A margin for stapling can be set on front/back sides. Step 1 Operation (display) Set to the 25 mode. Operation point Copy quantity setting button Main switch Magnification/ reduction button or the P button + the copy quantity setting button. Copy quantity setting button Copy button
2
Designate Address P31.
3 4 * Data 0 1 2 3 4 5 6 7
Modify data. C *See the table below. Press a copy button.
1-2 mode Original has a margin Original has a margin Original has no margin Original has no margin Original has a margin Original has a margin Original has no margin Original has no margin
2-1 mode Original has a margin Original has no margin Original has a margin Original has no margin Original has a margin Original has no margin Original has a margin Original has no margin
Shift on a reverse side Deletes a right margin on copying paper Shifts copying paper to the left
Both 1-1 and 2-2 modes treat all originals as no margin. Margins on copying paper are set as follows based on the above specifications.
Data 0 1-1 mode Shifts paper to the right 1-2 mode Shifts a backside to the left 2-1 mode Shifts even pages to the right 2-2 mode Shifts a front side to the right Deletes a right margin on a backside - ditto - ditto -
1 2
- ditto - ditto -
3
- ditto -
4 5 6 7
- ditto - ditto - ditto - ditto -
Shifts a backside to the left Shifts a front side to the right Deletes a right margin on a backside Shifts a front side to the right Deletes a right margin on a backside Shifts a backside to the left
Shifts paper to the right Shifts even pages to the right
Shifts paper to the right
- ditto -
Shifts even pages to the right
Shifts paper to the right Shifts a backside to the left Shifts a front side to the right Shifts even pages to the right Shifts a backside to the left Shifts a front side to the right Shifts paper to the right Shifts a backside to the left
Shifts a front side to the right Shifts a backside to the left - ditto - ditto - ditto -
5 - 31
ADJUSTMENT
[18] Finisher Initial Mode Setting
Set a priority mode in selecting a sorter. Step 1 Operation (display) Set to the 25 mode. Operation point Copy quantity setting button Main switch Magnification/ reduction button or the P button + the copy quantity setting button. Copy quantity setting button
[20] Auto Reset Time
Set time until returning to an automatic status after manual operation. Step 1 Operation (display) Set to the 25 mode. Operation point Copy quantity setting button Main switch Magnification/ reduction button or the P button + the copy quantity setting button. Copy quantity setting button
2
Designate Address P46.
2
Designate Address P48.
3
Modify data. 0: Non-sorter priority C 1: Sort is preferred 2: Group is preferred Press a copy button.
3
Modify data. 0: No C 1: 1.5 minute 2: 1.5 minutes Press a copy button.
4
Copy button
4
Copy button
[19] Setting Cancellation of Fixing Abnormality
Cancel fixing abnormality [F34], [F35] and [F36]. Step 1 Operation (display) Set to the 25 mode. Operation point Copy quantity setting button Main switch Magnification/ reduction button or the P button + the copy quantity setting button. Copy quantity setting button Copy button
[21] Selection of fixing Control During Automatic Shut Off
When automatic shut off is conducted, set whether or not control related to fixing will be continued. Step 1 Operation (display) Set to the 25 mode. Operation point Copy quantity setting button Main switch Magnification/ reduction button or the P button + the copy quantity setting button. Copy quantity setting button Copy button
2
Designate Address P47.
2
Designate Address P49.
3 4
Input 0 to data. Press a copy button.
3
4
Modify data. 0: No 1: Yes Press a copy button.
5 - 32
ADJUSTMENT
[22] A3 Copy 2 Counts Setting
Set how to proceed copy count for A3 paper. Step 1 Operation (display) Set to the 25 mode. Operation point Copy quantity setting button Main switch Magnification/ reduction button or the P button + the copy quantity setting button. Copy quantity setting button Copy button
[24] Setting Auto Button Function and Auto Condition when Setting ADF Original
Set automatic functions when an automatic button is pressed and when an original is set in ADF. Step 1 Operation (display) Set to the 25 mode. Operation point Copy quantity setting button Main switch Magnification/ reduction button or the P button + the copy quantity setting button. Copy quantity setting button Copy button
2
Designate Address P50.
2
Designate Address P56.
3
4 *
Modify data. 0: 1 count 1: 2 counts Press a copy button.
3
Modify data. 0 to 3 (see *1) Press a copy button.
When 2 counts is set, conduct 2 counts the total counter, the key counter, the PM counter and the drum counter concurrently.
4
*1: Automatic button function and ADF original setting indication. Data 0 1 2 3
C
Automatic button function Full auto *Manual select Full auto C *Manual select
C
[23] Data Control Function Select
Set protection of the service control operator mode. Step 1 Operation (display) Set to the 25 mode. Operation point Copy quantity setting button Main switch Magnification/ reduction button or the P button + the copy quantity setting button. Copy quantity setting button Copy button
ADF original setting indication ADF select ADF select Full auto C *Manual select
*Selectable by 25 mode P58
2
Designate Address P52.
[25] Setting of operation When the Key Counter is Pulled out
Set behavior when the key counter is removed in copying. Step 1 Operation point Copy quantity setting button Main switch Magnification/ Designate Address P57. reduction button or the P button + the copy quantity setting button. Copy quantity Modify data. 0: Exit a paper in copying and setting button stop operation. 5: Stop operation immediately. Copy button Press a copy button. Operation (display) Set to the 25 mode.
3
4
Modify data. 0: No function 8: Cancel protection Press a copy button.
2
3
4
5 - 33
ADJUSTMENT
[26] Switching Auto/Manual Priority
Set combination of individual selection when the automatic button is pressed. Step 1 Operation (display) Set to the 25 mode. Operation point Copy quantity setting button Main switch Magnification/ reduction button or the P button + the copy quantity setting button. Copy quantity setting button Copy button
[27] Switching the contents of Normal/Fine
Set the combination of bit number when the image reading button is turned ON. Step 1 Operation (display) Set to the 25 mode. Operation point Copy quantity setting button Main switch Magnification/ reduction button or the P button + the copy quantity setting button. Copy quantity setting button
2
Designate Address P58.
2
Designate Address P60.
3 4
Modify data. 0 to 7 (see *1) Press a copy button.
3
*1: Combination of individual selection. Data 0 1 2 3 4 5 6 7
C
ADF select ADF Platen ADF Platen ADF Platen ADF Platen
APS select APS APS C *Manual C *Manual APS APS C *Manual C *Manual
EE select EE EE EE EE Manual Manual Manual Manual
4
C
Modify data. 0: 1ED+2ED 1: 1ED+4ED 2: 2ED+4ED Press a copy button.
Copy button
*ED: Error Diffusion Note: Default selection of reading mode(normal/fine/S-fine) 25mode,P59 0:Normal(default) 1:Fine 2:S-fine
*APS is selected only for USA machine.
[28] Selecting the Erasing Amount of the Leading Edge in ADF Mode
Set the erasing amount of the edge in ADF mode. Step 1 Operation (display) Set to the 25 mode. Operation point Copy quantity setting button Main switch Magnification/ reduction button or the P button + the copy quantity setting button. Copy quantity setting button
2
Designate Address P61.
3
4
Modify data. 0: 2mm 1: 3mm 2: 4mm 3: 5mm Press a copy button.
Copy button
5 - 34
ADJUSTMENT
[29] Setting of Auto Shut Off and Auto Pre-heating
Set auto shut off and auto pre-heating time. Step 1 Operation (display) Set to the 25 mode. Operation point Copy quantity setting button Main switch Magnification/ reduction button or the P button + the copy quantity setting button. Copy quantity setting button
[31] Selecting Outside Erasing the Original
Set whether or not space outside the original is erased. Step 1 Operation (display) Set to the 25 mode. Operation point Copy quantity setting button Main switch Magnification/ reduction button or the P button + the copy quantity setting button. Copy quantity setting button
2
Designate Address P62.
2
Designate Address P70.
3
4
Modify data. 0: No function Auto shut off 1: 2 minutes 2: 6 minutes 3: 10 minutes Auto pre-heating 4: 2 minutes 5: 6 minutes 6: 10 minutes Press a copy button.
3
4
Modify data. 0: Erase outside the original. 1: Entire image in the platen mode. C 2: Transfer paper prior any time Copy button Press a copy button.
C
*
When data "1" is selected, whole image determined by the selected paper size is copied only in case of platen copy.
Copy button
[30] Setting Paper Size for Trays 2, 3 and 4
Set paper size for Trays 2, 3 and 4. Step 1 Operation point Copy quantity setting button Main switch Designate address of waiting time. Magnification/ reduction button P67: Tray 2 or the P button + P68: Tray 3 the copy quanP69: Tray 4 tity setting button. Copy quantity Modify data. setting button 0 to 9 (see *1) Copy button Press a copy button. Operation (display) Set to the 25 mode.
[32] Toner Level Detecting Select
Set display timing of toner replenishing. Step 1 Operation (display) Set to the 25 mode. Operation point Copy quantity setting button Main switch Magnification/ reduction button or the P button + the copy quantity setting button. Copy quantity setting button
2
2
Designate Address P71.
3 4
3
*1: Size correspondence list. Data 0 1 2 3 4 Paper size A3 B4 A4R B5R A4 Data 5 6 7 8 9 Paper size B5 A5 F4 -
4
Modify data. 0: After copying 100 sheets. 1~3: After copying 1000 to 3000 sheets. Copy button Press a copy button.
5 - 35
ADJUSTMENT
[33] Master Key Code Setting
Set the master key code for entering into the E.K.C. operator mode and the data control system operator mode. Step 1 Operation point Copy quantity setting button Main switch Magnification/ Designate Address P72 to P79. reduction button or the P button + the copy quantity setting button. Copy quantity Modify data. Input the master key code into P72 setting button (the upper rank) to P79 (the lower rank). Copy button Press a copy button. Operation (display) Set to the 25 mode.
[35] Selecting Preliminary rotation of Polygon Motor
Set preliminary rotation of polygon motor in idling. Step 1 Operation (display) Set to the 25 mode. Operation point Copy quantity setting button Main switch Magnification/ reduction button or the P button + the copy quantity setting button. Copy quantity setting button
2
2
Designate Address P90.
3
3
4 *
With regard to addresses P72 to P79, input each data by means of procedures 2 to 4.
4
Modify data. 0: Not preliminary rotation 1: Preliminary rotation is 14000 rpm 2: Preliminary rotation is 11024 rpm 3: Preliminary rotation is 8000 rpm 4: Stop Copy button Press a copy button.
C
[34] Switching Longitudinal Line Paper/ Transversal Line Paper
Set separation conditions depending upon the kind of small size paper. Step 1 Operation (display) Set to the 25 mode. Operation point Copy quantity setting button Main switch Magnification/ reduction button or the P button + the copy quantity setting button. Copy quantity setting button
[36] Selecting the Timing of Polygon Motor Low Speed Rotation
Set time until the polygon motor is changed to low speed rotation after copying finishes. Step 1 Operation (display) Set to the 25 mode. Operation point Copy quantity setting button Main switch Magnification/ reduction button or the P button + the copy quantity setting button. Copy quantity setting button
2
Designate Address P88.
2
Designate Address P91.
3
4
Modify data. 0: All transversal line. 1: Transversal line only A4,B5 and by-pass. Copy button Press a copy button.
3
4
Modify data. 0: 15 seconds 1: 30 seconds 2: 60 seconds 3: 120 seconds Press a copy button.
Copy button
5 - 36
ADJUSTMENT
[37] Selecting Automatic Outside Erasing the Original
Set how to erase in using the erasing outside the original mode. Step 1 Operation (display) Set to the 25 mode. Operation point Copy quantity setting button Main switch Magnification/ reduction button or the P button + the copy quantity setting button. Copy quantity setting button
2
Designate Address P92.
3
4
Modify data. 0: Rectangular 1: Corresponding oblique original Copy button Press a copy button.
5 - 37
ADJUSTMENT
[38] 25 Mode Address Map
Address 00 01 02 03 04 05 06 07 Item Data for adjusting process: Re-write is prohibited Data for adjusting process: Re-write is prohibited Data for adjusting process: Re-write is prohibited Selecting data control system E.K.C. select Data for adjusting process: Re-write is prohibited FS-103 sub-tray is selected. (printer) Setting range Initialvalue 0~5 0~5 0,2,3 0 0
C
Change details
Remarks
Impossible to set other than 0 0: Not selected 1: Selected (no stop in limiting) 2: Selected (stop in limiting) 5: Selected (forced stop in limiting) 0: Not use 2: Sub-tray (reverse) 3: Sub-tray (normal) 0: Not conducting ATS 1: ATS can be conducted for all steps 2: ATS cannot be conducted for only the upper step 1:Stops (at max. 45 sheets) 2:Stops (at max. 40 sheets) 3:Stops (at max. 35 sheets) 4:Stops (at max. 50 sheets) 5:Stop after current copy (at max. 50 sheets) 6:Stop after current copy (at max. 45 sheets) 7:Stop after current copy (at max. 40 sheets) 8:Stop after current copy (at max. 35 sheets) 9:Stop after current copy (at max. 50 sheets) 0: 8.5×13 1: 8.25×13 2: 8.125×13.25 3: 8×13 0: 160°C 1: 170°C 2: 180°C 0: AB size 1: A size 2: 180°C 0: Japanese 1: English 2: American English 3: French C 1: English 0: American English C 2: French 3: Japanese 0: English 1: French 2: German 3: Italian C 0: AB size 1: A size 0: 11×17 3: 8.5×11R 0: A3 3: A5 6: B5R 0: Tray 1 3: Tray 4 0 ~ 3: 1 hour 4 ~ 6: 2 hours 7 ~ 9: 3 hours *D
C
0
08 09
ATS select FS-103 original quantity over is controlled.
0~2 0~9
0 -
C
10 11 12 13
F4 size select Data for adjusting process: Re-write is prohibited Temperature select in the pre-heating mode Data for adjusting process: Re-write is prohibited
0~3 0~2 -
0 0 -
14
Message language select
0~3
15
A size select (Europe)
C
C
0~1
16
Priority of the paper size Europe/USA (When APS released)
0~9
1: 8.5×14 4: 5.5×8.5
2: 8.5×11 5: SPECIAL
C
17
Jumping selection of the paper size Europe/USA(Select by using P+cassette size button)
C
0~9
18
Selecting the preferred cassette selection(Japan only) Shut off time select in the pre-heating mode. FS-102/FS-103 paper overload control
C
C
0~9
0
1: A4 4: OHTERS 7: B5 1: Tray 2 4: By-pass
2: A4R 5: F4 8: B4 2: Tray 3
Japan only
19 20
0~9 0~9
C
0 0
C
C
21 22 23 24 25 26
AMS select 102 101 Setting intermittent time for running test 100 Data control system select (Protection setting 1) ADF frame erasing select
C
0~1 0~9
0 0 0 1 0
C
0: selected 1 second to 255 seconds
1: not selected
0~2 0,5
5
0: protection 1: Canceling copy control protection 2: Canceling service control protection 0: No 5: Yes ( 5mm frame)
5 - 38
ADJUSTMENT
Address 27 28 29 30 105 104 102
C
Item PM cycle setting
Setting range Initialvalue
C
Change details *USA/Europe:120 *OTHERS :100
C C
Remarks
0~9
C
C
* 0* 0*
C
*C KBM:7 Others:0
31
Original image shift setting
0~7
32 33 34 35 36 37 38 39 40 41 42 43 44 45 46 47 48 49 50 51 52 53 54 55 56
105 104 103 102 101 100 105 104 103 102 101 100
C
C
0~9 Drum counter
C
C
C C
C
* * * * * * 0 0 0 0 0 0
*USA/Europe :119999 C *OTHERS :099999
0~9 PM counter
0~2 Sorter initial mode setting 0~9 Setting cancellation of fixing abnormality 0~2
C
0 0 0 0~2 0~1 0~8 0~3 0 0~5 0 0 0 0 1 0 3
Auto reset setting Selection of fixing control during automatic shut off A3 copy 2 counts setting Data for adjusting process: Re-write is prohibited Data control function select (Protect setting 2) Data for adjusting process: Re-write is prohibited Data for adjusting process: Re-write is prohibite