Text preview for : 03_MA-1535-2_PM.pdf part of Toshiba MA1535 Programming Manual



Back to : 03_MA-1535-2_PM.pdf | Home

TEC Electronic Cash Register

MA-1535-2 SERIES
Programming Manual
Document No. EO3-11102

Original Jan., 2003
(Revised )




PRINTED IN JAPAN
EO3-11102




TABLE OF CONTENTS

Page
1. INTRODUCTION ........................................................................................................ 1- 1
1.1 Main Features............................................................................................................... 1- 1

2. SPECIFICATIONS ...................................................................................................... 2- 1
3. RAM CLEAR, DATA CLEAR, STATUS CLEAR........................................................ 3- 1
3.1 RAM Clear .................................................................................................................... 3- 1
3.2 DATA Clear................................................................................................................... 3- 2
3.3 STATUS Clear .............................................................................................................. 3- 2

4. PROGRAMMING OPERATIONS ............................................................................... 4- 1
4.1 Basic Key Functions ..................................................................................................... 4- 2
4.2 Character Entry Method ................................................................................................ 4- 3
4.3 Condition Required for Programming Operations.......................................................... 4- 5
4.4 RAM Allocation Setting ................................................................................................. 4- 6
4.5 SFKC (Selective Function Key Code) Programming ..................................................... 4- 8
4.6 TAX System Programming........................................................................................... 4-11
4.7 EFT Programming........................................................................................................ 4-12
4.8 Store Message and Commercial Message Programming (Submode 1) ....................... 4-15
4.9 Cashier Code and Name Programming (Submode 2) .................................................. 4-17
4.10 Department Table Programming (Submode 3)............................................................. 4-20
4.11 PLU Table Programming (Submode 4) ........................................................................ 4-23
4.12 Time Setting or Adjustment (Submode 5)..................................................................... 4-27
4.13 Date Setting or Adjustment (Submode 6) ..................................................................... 4-28
4.14 Media Tender Key Setting (Submode 8) ...................................................................... 4-28
4.15 Financial Report Item Name Programming (Submode 9) ............................................. 4-30
4.16 Print Line Item Name Programming (Submode 10)...................................................... 4-33
4.17 Print Item on Reports Setting (Submode 11)................................................................ 4-36
4.18 Tax Table Programming (Submode 12) ....................................................................... 4-38
4.19 Department Group Name Programming (Submode 13) ............................................... 4-41
4.20 Display Upper-Row Message Programming (Submode 17) ......................................... 4-42
4.21 System Option Programming (Submode 18)................................................................ 4-49
4.22 Endorsement (or France Check Print) Message Programming (Submode 22) ............. 4-53
4.23 Link-PLU Table Programming (Submode 25)............................................................... 4-54
4.24 PLU Preset-Code Key Setting (Submode 27) .............................................................. 4-55
4.25 PLU Group Programming (Submode 29) ..................................................................... 4-55
4.26 Advertisement Message Programming (Submode 31) ................................................. 4-57
4.27 Report Header Name Programming (Submode 32) ..................................................... 4-59
4.28 Function Key (Combination Key) Setting (Submode 34) .............................................. 4-62
4.29 PLU Cashier Report Setting (Submode 35).................................................................. 4-63
4.30 %+ and %- Preset Rate Setting (Submode 36) ............................................................ 4-63
4.31 Foreign Currency Exchange Rate Setting (Submode 37)............................................. 4-65
4.32 + (Amount Charge) and - (Amount Discount) Preset Setting (Submode 38)................. 4-66
EO3-11102




Page
4.33 Manager Pass Code Programming (Submode 39) .......................................................4-68
4.34 Network Terminal No. Setting (Submode 40)................................................................4-68
4.35 COM Port Setting (Submode 41) ..................................................................................4-69
4.36 In-Store Marking Bar Code Programming (Submode 42)..............................................4-70
4.37 Register No. Setting (Submode 43) ..............................................................................4-71
4.38 Line Feed Value of Endorsement Message (Submode 46) ...........................................4-71
4.39 Rounding Process Setting (Submode 47) .....................................................................4-72
4.40 Date Format Setting (Submode 49) ..............................................................................4-72
4.41 Printer Cutting Setting (Submode 51) ...........................................................................4-73
4.42 Store Coupon, Vender Coupon, Bottle Return Taxable Status Programming
(Submode 53)...............................................................................................................4-73
4.43 Food Stamp Programming (Submode 54) ....................................................................4-74
4.44 Age Limit Setting (Submode 55) ...................................................................................4-75
4.45 Tare Table Setting (Submode 56).................................................................................4-76
4.46 General Unit Weight Setting (Submode 57) ..................................................................4-76
4.47 Media Tender Key Setting 2 (Submode 58) ..................................................................4-77
4.48 EFT Timer and Status Setting (Submode 59) ...............................................................4-78
4.49 PLU Stock Loading or Changing (Submode 90) ...........................................................4-79

5. PROGRAMMED DATA VERIFICATION.....................................................................5- 1
5.1 Programmed Data Verification in BLIND Mode ..............................................................5- 1
5.2 Programmed Data Verification in X or SET Mode ..........................................................5- 2




CAUTION!
1. This manual may not be copied in whole or in part without prior written permission of TOSHIBA
TEC.
2. The contents of this manual may be changed without notification.
3. Please refer to your local Authorised Service representative with regard to any queries you may
have in this manual.

Copyright © 2003
by TOSHIBA TEC CORPORATION
All Rights Reserved
570 Ohito, Izunokuni-shi, Shizuoka-ken, JAPAN
1. INTRODUCTION EO3-11102

1.1 Main Features




1. INTRODUCTION
This programming manual for TEC Electronic Cash Register MA-1535-2 Series is provided for
salespersons, field engineers and other support personnel.

1.1 Main Features
< Hardware >
· Display: 10-digit 7-segment and 10-digit alphanumeric display
The alphanumeric display indicates PLU name and machine status.
· 3 ports of RS-232C: PC, Scanner, EFT, etc. can be connected.
· Expansion RAM: Up to 16Mbit Expansion RAM for rich RAM allocation can be attached.
· Keyboard: Normal type keyboard

< Software >
· Scanning function: Source marking and In-store marking are available.
· Up to 24,000 PLUs: PLUs by using expansion RAM: 24,000 PLUs (standard: 5,000 PLUs)
· 4 Tax memory: 4 Add-on Tax




1- 1
2. SPECIFICATIONS EO3-11102
(Revision Date: Aug. 26, 2004)
2. SPECIFICATIONS




2. SPECIFICATIONS
< Hardware >
SIZE: 410 mm (width) x 430 mm (depth) x 335 mm (height)
(including rubber feet)

WEIGHT: 12.5 Kg

POWER REQUIREMENT: AC 117V±10%, 60Hz±10%, 0.46A
AC 220~230V±10%, 50/60Hz±10%, 0.24A
AC 240V±10%, 50/60Hz±10%, 0.20A
(It differs depending on destination.)

BATTERY:
Type ------------------------------------------------- Lithium battery
Back-up duration --------------------------------- 6 months (in case of full charge)
Charge method ----------------------------------- Inserting the power plug into an outlet
Full charge time----------------------------------- 48 hours or more

AMBIENT TEMPERATURE: 0°C to 34°C

RELATIVE HUMIDITY: 10% to 80% (No condensation)

PRINTER:
Model------------------------------------------------ MT-51 (EPSON)
Print method --------------------------------------- Line thermal dot printing
Number of stations ------------------------------- 2 stations (receipt and journal)
Print speed----------------------------------------- 52 mm/second
Printable digits ------------------------------------ 24 digits/line on both receipt and journal
Character size------------------------------------- 1.67 mm (width) x 4.17 mm (height)
Line space ----------------------------------------- 5.21 mm
Character components-------------------------- 12 (width) x 24 (height) dots
(including 2-dot spacing in column)
Paper roll (receipt and journal) ---------------- 57.5±0.5 mm (width) x max. 80 mm (diameter)
Paper feed method------------------------------- Friction method
Receipt cut method ------------------------------ Auto cut




2- 1
2. SPECIFICATIONS EO3-11102
(Revision Date: Aug. 26, 2004)
2. SPECIFICATIONS



< Software >
Number of department: Max. 99 departments (standard: 30 departments)

Number of PLU: Max. 24,000 PLUs (standard: 5,000 PLUs)

Number of cashier: Max. 40 cashiers (standard: 10 cashiers)

TAX memory: 4 Add-on TAX

Memory balance: See below.
GT (Grand Total) = Sum of Daily GS (Gross Sale)
NET GT = Sum of Daily All-media Sales
GS (Gross Sale) = (Sum of Positive Depts.) + (Sum of Taxes) + (%+) + (Item
Correct) + (Void) + (All Void) + (%- on Line Items) + (Amount
Discount on Line Items) + (Store Coupon) + (Returned
Merchandise) + (Negative Mode Total) + (Negative Tax)
Net Sale with Tax = (Sum of All Depts.) + (Sum of Taxes) + (%+)
= (GS) ­ (Item Correct) ­ (Void) ­ (All Void) ­ (Sum of Negative
Depts.) ­ (%- on Line Items) ­ (Amount Discount on Line Items) ­
(Store Coupon) ­ (Returned Merchandise) ­ (Negative Mode
Total) ­ (Negative Tax)
All-media Sales = (Net Sale with Tax) ­ (%- on Subtotal) ­ (Amount Discount on
Subtotal) + (Positive HASH Depts.) + (Negative HASH Depts.) ­
(Vendor Coupon) ­ (Bottle Return)
= (Cash Sales) + (Check Sales) + (Sum of All Other Media Sales)
Sum of Hourly Range Sales = Net Sale with Tax (US balance)
Sum of Hourly Range Sales = Net Sale without Tax (Canada balance)

NOTE: (Sum of All Depts.) = (Sum of Positive Depts.) + (Sum of Negative Depts.) but excluding
HASH Depts.




2- 2
3. RAM CLEAR, DATA CLEAR, STATUS CLEAR EO3-11102

3.1 RAM Clear




3. RAM CLEAR, DATA CLEAR, STATUS CLEAR
CAUTION!
1. When setting up the MA-1535 for the first time, charge the ECR for 48 hours or more by
plugging the power cord into an AC outlet.
2. When using the MA-1535 unelectrified for 1 month or more, charge the ECR for 48 hours or
more by plugging the power cord into an AC outlet.
3. If the MA-1535 just unpacked or unelectrified for 1 month or more doesn't perform normally
at the power on, perform a RAM Clear, charge the ECR for 48 hours or more and then retry.

Chng trình Reset máy v nh mi 100%. Ch thc hin khi thc s cn hoc
3.1 RAM Clear khi cài t lúc u tiên
CAUTION!
This clear operation deletes all programmed data and sales data stored in the memory of the
ECR. (i.e., the register goes back to initial status.)

If the ECR becomes completely inoperative due to battery discharge or malfunction of the program
memory, the RAM Clear operation must be carried out. When the RAM Clear is operated, all memory
stored in the RAM will be cleared. (i.e., the programmed data and the sales data) In the clearing
process, the designated zero-amount format is reset. Also "Initial Data" and "Initial Status" for
respective programming items are automatically reset.

1. Use the S key to turn the Control Lock to "BLIND".
Dùng chìa S vn v trí mù <285 5(&(,37
7+$1. <28
2. Depress the following Numeric keys according to the type of keyboard.
Numeric Key Type of Keyboard
[3] [9] Normal Type Keyboard
5$0&
Nhp phím s [3] & [9] ri n phím Tính Tin [AT/TL]
3. Depress the [AT/TL] key. 70

4. A RAM Clear receipt is issued.

NOTE: When the RAM clear operation is performed, the condition "after all sales data reset" is
obtained, just as "Status Clear" and "Data Clear". Therefore, no Reset Report should be taken
for starting any programming operation.




3- 1
3. RAM CLEAR, DATA CLEAR, STATUS CLEAR EO3-11102

3.2 DATA Clear



Chng trình xóa ht data báo cáo bán hàng nhng vn còn gi các chng
3.2 DATA Clear trình cài t nh: Tên sp, giá, tên ca bán,
CAUTION!
This clear operation deletes all sales data of any operation sequence stored in the memory of the
ECR.

Performing the DATA Clear operation will clear only the sales data accumulated in the memory of the
ECR (report memory), however, the programmed data will not be cleared. By this operation, all sales
data including non-resettable totals and counters, Reset Report Counts, and Receipt Consecutive No.
are cleared.

1. Use the S key to turn the Control Lock to "BLIND".
Dùng chìa S vn v trí mù <285 5(&(,37
7+$1. <28
2. Depress the [3] key (Numeric key) and then the [AT/TL] key.
n phím [3] --> [AT/TL]
3. A DATA Clear receipt is issued.

'$7$&
NOTE: When the DATA clear operation is performed, the condition
"after all sales data reset" is obtained, just as "Status Clear" and 70
"Data Clear". Therefore, no Reset Report should be taken for
starting any programming operation.


Khi thao tác máy có gì ó sai mà n phím[C] vn không ht b li thì
3.3 STATUS Clear thc hin bc này gi là xóa Trng thái li
Performing the STATUS Clear operation will clear an error and the key locked condition, however, the
sales data and the programmed data will not be cleared by this operation. When the STATUS Clear is
operated to clear a key locked condition during sale, the sale item data that has already been entered
for the current sale will be cleared.

The STATUS Clear operation obtains the condition "after all sales data reset" which is required for
some programming operations, but this operation will not affect any sales data. This condition is
obtained by taking reset reports. In case you do not want to reset the sales data such as in business
hours, this function is effective. Depending on the programming item, sales data should be reset
instead of STATUS Clear to keep consistency between programmed data and sales data.

The STATUS Clear can be performed in 2 methods shown below.
Cách 1: Dùng chìa S vn v trí mù, n phím [0] -->[AT/TL]
< Method 1 > Nh là phím s 0 thôi nha!!!
<285 5(&(,37
1. Use the S key to turn the Control Lock to "BLIND". 7+$1. <28
2. Depress the [0] key (Numeric key) and then the [AT/TL] key.
3. A STATUS Clear receipt is issued.


< Method 2 > 67$786&
1. Remove the power code of the ECR from the wall outlet.
70
2. Use the S key to turn the Control Lock to "BLIND".
3. Plug in the power code and turn the power ON.
4. A STATUS Clear receipt is issued.

Cách 2 : u tiên rút dây ngun ra ri dùng chìa S vn v trí mù, xong cm dây ngun li
thì máy s t ng thc hin status clear



3- 2
4. PROGRAMMING OPERATIONS EO3-11102

4. PROGRAMMING OPERATIONS




4. PROGRAMMING OPERATIONS
Table of Programming Operations
Control Lock
Operation Position
Submode Page
Basic Key Functions --- --- 4- 2
Character Entry Method --- --- 4- 3
Condition Required for Programming Operations --- --- 4- 5
RAM Allocation Setting BLIND --- 4- 6
SFKC (Selective Function Key Code) Programming BLIND --- 4- 8
TAX System Programming BLIND --- 4-11
EFT Programming BLIND --- 4-12
Store Message and Commercial Message Programming SET 01 4-15
Cashier Code and Name Programming SET 02 4-17
Department Table Programming SET 03 4-20
PLU Table Programming SET 04 4-23
Time Setting or Adjustment SET 05 4-27
Date Setting or Adjustment SET 06 4-28
Media Tender Key Setting SET 08 4-28
Financial Report Item Name Programming SET 09 4-30
Print Line Item Name Programming SET 10 4-33
Print Item on Reports Setting SET 11 4-36
Tax Table Programming SET 12 4-38
Department Group Name Programming SET 13 4-41
Display Upper-Row Message Programming SET 17 4-42
System Option Programming SET 18 4-49
Endorsement (or France Check Print) Message Programming SET 22 4-53
Link-PLU Table Programming SET 25 4-54
PLU Preset-Code Key Setting SET 27 4-55
PLU Group Programming SET 29 4-55
Advertisement Message Programming SET 31 4-57
Report Header Name Programming SET 32 4-59
Function Key (Combination Key) Setting SET 34 4-62
PLU Cashier Report Setting SET 35 4-63
%+ and %- Preset Rate Setting SET 36 4-63
Foreign Currency Exchange Rate Setting SET 37 4-65
+ (Amount Charge) and ­ (Amount Discount) Preset Setting SET 38 4-66
Manager Pass Code Programming SET 39 4-68
Network Terminal No. Setting SET 40 4-68
COM Port Setting SET 41 4-69
In-Store Marking Bar Code Programming SET 42 4-70
Register No. Setting SET 43 4-71
Line Feed Value of Endorsement Message SET 46 4-71
Rounding Process Setting SET 47 4-72
Date Format Setting SET 49 4-72
Printer Stamp Setting SET 52 4-73
Store Coupon, Vender Coupon, Bottle Return Taxable Status Programming SET 53 4-73
Food Stamp Programming SET 54 4-74
Age Limit Setting SET 55 4-75
Tare Table Setting SET 56 4-76
General Unit Weight Setting SET 57 4-76
Media Tender Key Setting 2 SET 58 4-77
EFT Timer and Status Setting SET 59 4-78
PLU Stock Loading or Changing X or Z 90 4-79

4- 1
4. PROGRAMMING OPERATIONS EO3-11102

4.1 Basic Key Functions



Programming Operations are performed in "BLIND" position or in "SET"
position of the Control Lock.
When you turn the Control Lock to "BLIND" or "SET" position, the letter "S"
in "BLIND" mode or the letter "P" in "SET" mode is displayed on the
leftmost column of the 10-digit Alphanumeric Display.



CÁCH VÔ CHNG TRÌNH CÀI T:
4.1 Basic Key Functions Công dng các phím:
Phím [#NS] dùng vào chng trình s ví d: Vào chng trình cài tên sp, giá
1) Main keys thì n [4] -->[#NS]
[#/NS]------------------ Used to enter the Program Submode No., Address data, Item data.
Used to end the entire Program Submode Sequence.
[ST], [AT/TL] -------- Used to enter the Address No., Item Code.
Used to end the Item data entries.
Phím [ST], [AT/TL] dùng vào item bên trong ca chng trình hoc
2) [C] key lu item va cài t
· When the program data has finished to be printed, the [C] key cannot clear it. If you correct the
program data, re-enter the data.
· Before the program data is printed, the [C] key can clear it. (except in the SFKC programming
operation) Nu nhp ln item nào ó bm [C] xóa nhp li
3) [ITEM CORR] key
When you enter incorrect settings, depressing the [ITEM CORR] key can return the display to the
previous item setting. Nu nhp sai item nào ó n [ITEM CORR] tr v màn hình trc

4) To clarify the operation flow, definitions of keys of the ECR keyboard are as shown below.
| | ------- Selective numeric value which is entered through the Numeric keys.
[ ]-------- Depression of the function key.
xxxx ---------- Fixed numeric value which is entered through the Numeric keys.
Fixed




4- 2
4. PROGRAMMING OPERATIONS EO3-11102

4.2 Character Entry Method




4.2 Character Entry Method Cách nhp ký t (ch cái) trên máy
Character Entry Method is to set characters by entering Character Code. This method is allowed on
the ECR keyboard.
a b c d e f




a

b

c

d

e

f


Trên ây là Bng mã ký t: Nhp ký t bng cách nhp mã hàng ca ký t ó trc ri
nhp mã ct ca ký t ó sau. Ví d: Mun nhp ch A thì n [4] -->[1] vì mã ca ch A
là 41 theo bng trên

4- 3
4. PROGRAMMING OPERATIONS EO3-11102

4.2 Character Entry Method



Character Setting Operation Hoc có th nhp ch trc tip theo s phím bên di
Key layout required at character setting is shown below. (Keys of bold characters are used at
programming operation.) Phn tô en dùng nhp mã ký t

f #/NS E J O T Y SPACE



e C (Clear) D I N S X :

d 7 8 9 C H M R W ,

c 4 5 6 B G L Q V .

b 1 2 3 A F K P U Z

a 0 00 . AT/TL



As character entry method, the Character Codes shown on the previous page are used basically. The
above shadowed keys are used for character code entry. To enter numeric rows and columns, the Ten
Keys on the keyboard are used. To enter alphabetic rows and columns A to F, the shadowed keys a to
f are used, respectively. When entering character codes, enter row code and then column code.
Therefore, one character should consist of two codes.


· To set a regular-sized character, enter Row code and then Column code.
Example) To set "A", enter [4] [1].
To set "n", enter [6] [e].
To set "ä", enter [e] [e].

· To set a blank instead of a character, enter [2] [0].

· To set a double-sized character, enter [f] [f] and then enter Row code and the Column code.
Example) To set "Drink", "D" in double-sized, and "rink" in regular-sized;
[f] [f] [4] [4] [7] [2] [6] [9] [6] [e] [6] [b]
D r i n k
Bm ch [f] 2 ln trc khi nhp mã ký t cho ch ó ln hn (double size)
To set "Drink", all in double-sized;
[f] [f] [4] [4] [f] [f] [7] [2] [f] [f] [6] [9] [f] [f] [6] [e] [f] [f] [6] [b]
D r i n k

The keys of SPACE and big-letter alphabets are used to enter spaces and alphabets in big letter
directly from the keyboard instead of character code entry.

Phím SPACE nhp khong trng gia các ký t




4- 4
4. PROGRAMMING OPERATIONS EO3-11102

4.3 Condition Required for Programming Operations




4.3 Condition Required for Programming Operations
"CONDITION" is given at the top of each programming operation. The ECR must satisfy this condition
to perform programming operations.

There are two types of conditions:

"Any time outside a sale"
It means that the programming operation is allowed when a sale is finalized before going into any other
sale entry.

"After------ reset"
It means that the designated reset report must be taken before entering the programming operation.
Attempting operations without taking the report will cause an error. However, the condition "After------
reset" doesn't mean "immediately after------ reset".

After the designated reset report is taken, performing the programming operations in the SET, X, or Z
mode is within the condition "After------ reset". And the operations are still allowed.

On the contrary, after the designated reset report is taken, entering sales data relating to the report
data in the REG, or - mode will cause the programming operation not to be allowed. And the same
reset report must be taken.

Thus the condition "After------ reset" indicates that all sales data relating to the report data must be zero
(except non-resettable memory data). Because of this "CONDITION" requirement, the report data will
be protected from any inconsistencies of sales data entered in the period from a resetting of the report
to another resetting of the same report next time.




4- 5
4. PROGRAMMING OPERATIONS EO3-11102

4.4 RAM Allocation Setting




4.4 RAM Allocation Setting
The type of ECR, the Numbers of Departments, PLUs, and Cashiers can be set in this submode.
CONDITION After a RAM clear

OPERATION Control Lock: BLIND

01 [#/NS] |Type of ECR| [AT/TL]
1 digit (0 or 1)
0: without PLU accumulation (Default)
1: with PLU accumulation


|Number of Departments| [AT/TL]
Max. 2 digits



|Number of PLUs| [AT/TL]
Max. 5 digits (See * for the value
of each item.)

|Number of Cashiers| [AT/TL]
Max. 2 digits




[AT/TL]


* Value to be set for the Number of Departments, the Number PLUs and the Number of Cashiers:
Case 1: Without PLU accumulation
Item Default Value Value range when Value range when 4Mbit Value range when 12Mbit
(Number of:) (auto-set a RAM Clear) Standard Memory is used Expansion Memory is used Expansion Memory is used
Departments 30 1 to 99 1 to 99 1 to 99
PLUs 5,000 0 to 6,168 0 to 12,336 0 to 24,000
Cashiers 10 0 to 40 0 to 40 0 to 40

Case 2: With PLU accumulation
Item Default Value Value range when Value range when 4Mbit Value range when 12Mbit
(Number of:) (auto-set a RAM Clear) Standard Memory is used Expansion Memory is used Expansion Memory is used

Departments 30 1 to 99 1 to 99 1 to 99
PLUs 5,000 (NOTE 3) 0 to 4,440 0 to 8,880 0 to 17,760
Cashiers 10 0 to 40 0 to 40 0 to 40


NOTES: 1. Even when a large area remains to be unallocated in the RAM, setting of any item
cannot exceed its value range specified in the table above.
2. When you enter incorrect values, depressing the [C] key will return the display to the
previous item.
3. With PLU accumulation, 5,000 is automatically set after a RAM clear, however, the
number of PLUs can be set up to 4,440 when the Standard Memory is used.




4- 6
4. PROGRAMMING OPERATIONS EO3-11102

4.4 RAM Allocation Setting



Example)
To allocate the RAM as follows;
Expansion Memory: None

Type of ECR: without PLU accumulation
Number of Departments: 30 Departments
Number of PLUs: 3,000 PLUs 6
Number of Cashiers: 10 cashiers 0(025< 2.
'(37751
'(3735* '(
Control Lock: BLIND &$6+,(535* $
'(376$/( $
01 [#/NS] &$6+,(56$/( '
0 [AT/TL] (Type of ECR) (1'%$6( %
30 [AT/TL] (Number of Departments) 3/867$57
3/8(1' )
3000 [AT/TL] (Number of PLUs)
10 [AT/TL] (Number of Cashiers)
[AT/TL] (To complete this program.)
3/87<3(
'(37
3/8
&$6+,(5

70




4- 7
4. PROGRAMMING OPERATIONS EO3-11102
(Revision Date: Apr. 28, 2004)
4.5 SFKC (Selective Function Key Code) Programming


Cách cài t phím công nng lên bàn phím máy tính tin
4.5 SFKC (Selective Function Key Code) Programming
SFKC Programming is to determine the keyboard layout with the required keys. This operation must
be performed first before any other programming operation. If the RAM Clear is performed prior to the
SFKC programming, program only the keys that require changes from the SFKC in the Standard
Keyboard which has been set by the RAM Clear operation automatically. (For Standard Keyboards,
see Page 4-10.) iu kin trc khi cài: Ly ht báo cáo Z, Data clear hoc Status clear
CONDITION After all Z & GTZ reports, or after RAM Clear, DATA Clear or STATUS Clear

OPERATION Control Lock: BLIND Chìa v trí mù
20 [#/NS] 10 |SFKC| [Key]
Fixed Refer to the SFKC table. A key that requires the
(See NOTE below.) SFKC function.
Repeat

20 |Department No.| [Key]
Department
Fixed Max. 2 digits (1 to 99)* A key that requires the
SFKC function. Key
Repeat


Cài phím mã sp 3 096 [Key]
PLU Preset-
bm gi nhanh Fixed Fixed A key that requires the
SFKC function. Code Key
Repeat


500 |Media Tender Key No.| [Key]
Fixed 1 digit (2 to 9)** A key that requires the Media
SFKC function. Tender Key
Repeat



[#/NS]

STEP 1. Enter 20 and depress the [#/NS] key. This operation declares on the SFKC Programming.
STEP 2. Enter [1] [0], SFKC (see SFKC Table on Page 4-9), and then depress a key which requires
the key name of the SFKC. Repeat these operations until all required keys are set with their
own SFKCs. Each key of the keyboard must correspond to one SFKC.
STEP 3. Enter [2] [0], Department No. (1 to 99)*, and then depress a key to be the Department key.
Repeat these operations until all required keys are set with their own Department keys.
STEP 4. Enter [3] and [0] [9] [6], and then depress a key to be the PLU Preset-Code key. Repeat
these operations until all required keys are set with their own PLU Preset-Code keys.
STEP 5. Enter [5] [0] [0], Media Tender Key No. (2 to 9)**, and then depress a key to be the Media
Tender key. Repeat these operations until all required keys are set with their own Media
Tender keys.
STEP 6. Depress the [#/NS] key to end the SFKC Programming operation.

* The Department keys should be set within the Number of Departments which were set in RAM
Allocation Setting.
** The Media Tender Key No.1 has already been set to the [AT/TL] key.
By allocating the Media Tender Key No. 8 to CREDIT and the Media Tender Key No. 9 to DEBIT,
the EFT function will be available.
NOTE: If "9999" is entered as SFKC, the key will be dead. (V2 and after)


4- 8
4. PROGRAMMING OPERATIONS EO3-11102
(Revision Date: Apr. 28, 2004)
4.5 SFKC (Selective Function Key Code) Programming



SFKC Table
SFKC Key Name SFKC Key Name
11 000 (Triple-zero) 61 V.CPN (Vendor Coupon)
12 Reserved 62 BTR (Bottle Return)
13 PLU (Price-Look-Up) 63 FS/M (Food Stamp Modifier)
14 %- (Percent Discount) 64 FS TL/TEND (Food Stamp Total/Tender)
15 %+ (Percent Charge) 65 HOLD/RECALL (Hold/Recall)
16 - 66 ID CHECK
17 + 67 SCALE
18 VOID (Void) 68 TARE
19 ITEM CORR (Item Correct) 69 TARE2
20 RTN MDSE (Returned Merchandise) 70 LC OPEN (V2 and after)
22 PRICE 1
23 PRICE 2
24 PRICE 3
25 RA/LOAN (Received-on Account/Loan)
26 PO/PICK-UP (Paid-Out/Pick-Up)
27 CURRENCY (Foreign Currency)
28 DEPT SHIFT (Department Shift)
29 READ (Read)
30 TAX 1/M (Tax 1 Modifier)
31 TAX 2/M (Tax 2 Modifier)
32 TAX 3/M (Tax 3 Modifier)
33 TAX 4/M (Tax 4 Modifier)
34 TAX EX (Non-Tax)
35 JOURNAL PRINT (Thailand specification)
36 TAX DISPLAY (Columbia specification)
37 VALI DATE
38 ALL VOID (All Void)
39 ADD PLU (PLU Add)
40 CHECK No. (Check Number)
41 FUNCTION 1
42 FUNCTION 2
43 FUNCTION 3
44 FUNCTION 4
45 FUNCTION 5
46 FUNCTION 6
47 FUNCTION 7
48 FUNCTION 8
49 FUNCTION 9
50 FUNCTION 10
51 GST/M (GST Modifier)
52 RECEIPT ISSUE (Receipt Post-issue)
53 PRICE
54 EAN
56 MANUAL CARD #
57 OFF LINE AUTH
58 POST AUTH
59 SPLIT PRICE
60 S.CPN (Store Coupon)




4- 9
4. PROGRAMMING OPERATIONS EO3-11102

4.5 SFKC (Selective Function Key Code) Programming







6
Map code ! )&
! )& NOTES: 1. FCxx: Function Key
! )& DPxx: Department Key
! )&
! )& PLU: PLU Preset-Code Key
! )& TDxx: Media Tender Key
! )& 2. For the Keys not described in the SFKC
! )& Table ([LOG RECEIPT], [#/NS], [RF],
! )&
! )& [JF], [C], [X/TIME], [ST], [AT/TL], [.], [0],
! )& [00], and [1] to [9]), they cannot be
! '3 programmed.
! '3
! '3
! '3
! '3
! '3
! '3
! '3
! '3
! '3
! '3
! '3
! '3
! '3
! 3/8
! 7'
! 7'
! 7'

70




Standard Keyboard (Auto-set by RAM Clear)
--- Normal Type Keyboard ---
LOG HOLD/
RECEIPT BTR RECALL #/NS RF JF DP 1 DP 6 DP 11 DP 16 DP 21 DP 26
0 1 2 3 4 5 6 7 8 9 10 11 12
RECEIPT ALL
ISSUE VOID PO C X/TIME DP 2 DP 7 DP 12 DP 17 DP 22 DP 27
13 14 15 16 17 18 19 20 21 22 23 24 25 26 27


CUR (-) R/A 7 8 9 DP 3 DP 8 DP 13 DP 18 DP 23 DP 28
28 29 30 31 32 33 34 35 36 37 38 39 40 41 42
RTN
MDSE %- TAX/EX 4 5 6 DP 4 DP 9 DP 14 DP 19 DP 24 DP 29
43 44 45 46 47 48 49 50 51 52 53 54 55 56 57


VOID READ TX1/M 1 2 3 DP 5 DP 10 DP 15 DP 20 DP 25 DP 30
58 59 60 61 62 63 64 65 66 67 68 69 70 71 72
ITEM
CORR PLU TX2/M 0 00 . ST AT/TL CHECK CHARGE CPN
73 74 75 76 77 78 79 80 81 82 83 84 85 86 87



NOTE: The numbers at the bottom of each key are shown as map code.




4-10
4. PROGRAMMING OPERATIONS EO3-11102

4.6 TAX System Programming




4.6 TAX System Programming
TAX System for the ECR can be set in this submode.
CONDITION After all Z & GTZ reports, or after RAM Clear, DATA Clear or STATUS Clear

OPERATION Control Lock: BLIND

30 [#/NS] 1 |TAX System| [AT/TL] [#/NS]
Fixed 1 digit (1 to 4)
1: US Break (Default)
2: Canadian (General)
3: Canadian (Tax on tax)
4: Canadian (Ontario)



NOTES: 1. After the RAM Clear, the TAX System is set to US Break as standard.
2. By performing this programming, Tax Table Programming (Submode 12) will be reset.


Example)
To set the TAX System as follows;
TAX System: US Break

Control Lock: BLIND
30 [#/NS]

11 [AT/TL]
[#/NS]
6
7$; %$/$1&

70




4-11
4. PROGRAMMING OPERATIONS EO3-11102

4.7 EFT Programming




4.7 EFT Programming
For EFT function, the following 4 settings should be programmed and the following 5 operations can be
performed here. Before performing 4.7.2 Dial In Load Command Sending, 4.7.6 Dial Out Load
Command Sending, 4.7.7 Network List Output, 4.7.8 Local Total Report Output, and 4.7.9 Clear
Current Batch, you should make sure that the EFT terminal is connected and that the EFT setting had
been done in 4.35 COM Port Setting (Submode 41).

4.7.1 PIN Pad Selection
The use of PIN Pad and the type can be selected here.
CONDITION Anytime outside a sale

OPERATION Control Lock: BLIND

40 [#/NS] |Type of PIN Pad| [AT/TL] [#/NS]
1 digit (0, 3, or 4)
0: Not used
3: DUKPT Debit
4: NOVA Debit (Default)
6
3,1 3$'

70




4.7.2 Dial In Load Command Sending
The Dial In Load Command will be sent to the EFT terminal by the operation below. Before performing
this operation, you should make sure that the EFT terminal is connected and that the EFT setting had
been done in 4.35 COM Port Setting (Submode 41).
CONDITION Anytime outside a sale

OPERATION Control Lock: BLIND

41 [#/NS] [AT/TL]


4.7.3 Telephone Number Setting
CONDITION Anytime outside a sale

OPERATION Control Lock: BLIND

42 [#/NS] |Telephone Number| [AT/TL] [#/NS]
Max. 25 digits
(See NOTE below.)


NOTE: The [0] to [9], [00], and [.] keys only can be used.
The value "0" is set as a default.
6
3+21(

70




4-12
4. PROGRAMMING OPERATIONS EO3-11102

4.7 EFT Programming



4.7.4 Host ID Number Setting
CONDITION Anytime outside a sale

OPERATION Control Lock: BLIND

43 [#/NS] |ID Number| [AT/TL] [#/NS]
8 digits fixed
(00000000 to 99999999) 6
NOTE: The value "00000000" is set as a default. +267 ,'

70




4.7.5 Dialing System Setting
CONDITION Anytime outside a sale

OPERATION Control Lock: BLIND

44 [#/NS] |Dialling System| [AT/TL] [#/NS]
1 digit (0 or 1)
1: Pulse dialing (Default)
2: Tone dialing
6
',$/,1*

70




4.7.6 Dial Out Load Command Sending
By this operation, the Telephone Number, Host ID Number and Dialing System programmed will be
sent to the EFT terminal. Before performing this operation, you should make sure that the EFT
terminal is connected and that the EFT setting had been done in 4.35 COM Port Setting (Submode
41).
CONDITION Anytime outside a sale

OPERATION Control Lock: BLIND

45 [#/NS] [AT/TL] [#/NS]




4-13
4. PROGRAMMING OPERATIONS EO3-11102

4.7 EFT Programming



4.7.7 Network List Output
By this operation, list of network information stored in the EFT terminal (Data Tran) will be printed out
from the printer provided for the ECR. In this list, functions programmed in the EFT terminal,
allowance for the functions (ON/OFF status), and EFT terminal version will be printed. Before
performing this operation, you should make sure that the EFT terminal is connected and that the EFT
setting had been done in 4.35 COM Port Setting (Submode 41).
CONDITION Anytime outside a sale

OPERATION Control Lock: BLIND


46 [#/NS] [AT/TL] [#/NS]
EFT terminal Version
6
Functions programmed &+. 96 1'2 9HU
in the EFT terminal 21 21 21 2))

Allowance for the functions 70
(ON/OFF status)



4.7.8 Local Total Report Output
By this operation, sales information stored in the EFT terminal will be printed out from the printer
provided for the ECR. Before performing this operation, you should make sure that the EFT terminal is
connected and that the EFT setting had been done in 4.35 COM Port Setting (Submode 41).
CONDITION Anytime outside a sale

OPERATION Control Lock: BLIND

47 [#/NS] [AT/TL]
6
Amount, Count

2: AMEX 7: Diner's Club or Carte Blanche
3: VISA 8: JCB
4: Master Card 9: Debit
5: Discover 99: Total for all card types
6: Private Label




70



4.7.9 Clear Current Batch
By this operation, reported information for EFT will be cleared. Before performing this operation, you
should make sure that the EFT terminal is connected and that the EFT setting had been done in 4.35
COM Port Setting (Submode 41).
CONDITION Anytime outside a sale

OPERATION Control Lock: BLIND
6
48 [#/NS] [AT/TL]
()7 5(3257 &/($5

70




4-14
4. PROGRAMMING OPERATIONS EO3-11102

4.8 Store Message and Commercial Message Programming (Submode 1)


Chng trình to tên Ca hàng: 1 --> [#NS]
4.8 Store Message and Commercial Message Programming (Submode 1)
Store Message and Commercial Message to be printed as receipt header can be programmed here.
CONDITION Anytime outside a sale

OPERATION Control Lock: SET


01 [#/NS] |Line No.| [#/NS] Repeat for other lines.
2 digits (01 to 07)

(For sequentially programming lines,
the Line Number specification can be
skipped.)



Character Entries [AT/TL] [#/NS]
Max. 24 characters/line Complete this Complete this
(See 4.2 Character Entry line. programming
Method.) operation.


NOTES: 1. For each line, up to 24 regular-sized characters or 12 double-sized characters can be
entered. Also a combination of both types can be entered.
2. If incorrect characters are programmed, depress the [C] key to clear all characters on a
line and then re-enter characters from the beginning, or end the line with the [AT/TL]
key and reprogram the entire line. The new data will be active.
3. When all the lines have been programmed, do a check by issuing a receipt. Only the
lines with errors requires to be re-programmed. Other lines will not be affected.
4. When blanks are entered for the whole one line, it causes one line space.

Example) Tên CH to c 7 dòng, mi dòng ti a 24 ký t
To program the following Store Message and Commercial Message
(under the Store Message Print feature)

T E C S T O R E
Line No. 1
1 3 4 3 P E A C H D R I V E
Line No. 2
P H O N E : 8 7 - 6 4 3 7
Line No. 3

Line No. 4

O p e n 8 : 0 0 a m t o 7 : 0 0 p m Line No. 5

C l o s e d : e v e r y W e d n e s d a y Line No. 6

Line No. 7




4-15
4. PROGRAMMING OPERATIONS EO3-11102

4.8 Store Message and Commercial Message Programming (Submode 1)



Key Operation: Control Lock: SET, Enter 01 and depress the [#/NS] key.

01 [#/NS] (Line No. 1) [2] [0] (Space)
[2] [0] (Space) [3] [7] (7)
[2] [0] (Space) [3] [a] (:)
[2] [0] (Space) [3] [0] (0)
[f] [f] [5] [4] (T) [3] [0] (0)
[f] [f] [4] [5] (E)