Text preview for : Panasonic_2006_PDP_Training_Guide_[TM].pdf part of panasonic Panasonic 2006 PDP Training Guide [TM] panasonic Monitor Panasonic_2006_PDP_Training_Guide_[TM].pdf
Back to : Panasonic_2006_PDP_Traini | Home
Service Repair Handbook
( based on year 2006 models )
Matsushita Electric Industrial Co., Ltd.
Panasonic AVC Networks Company
CS Promotion Cente
Case ( 1 ) Plasma LED blinking information for diagnostic ( by model, by series )
37/42SD 5 series 6 series 7 series 8 series 9 series
42HD
1 --- --- D D D
2 SC/SS/ SC/ SC/ SC/ P/D
SU/SD SU/SD SU/SD SU/SD
3 D D D D D
4 D/P D/P D/P D/P P
5 P P P P P/D/DA
6 FAN FAN FAN FAN SC/D
(HD (HD only) (HD only) (HD only)
7 --- SC SC SC SC/SU/SD
8 --- --- --- --- SS
9 --- SS SS SS D
10 --- --- J/PF J/(P) P/J/HB
11 --- --- --- --- FAN(HD
13 --- --- --- --- (DA)
Case ( 1 ) Plasma LED blinking information for diagnostic ( by model, by series )
50HD 5 series 6 series 7 series 8 series 9 series
1 --- --- D D D
2 SC/SS/ SC/SS SC/SS SS P/D
SU/SD/C
3 D D D D D
4 D/P D/P D/PD/P P
5 P P P P P/D/DA
6 FAN FAN FANFAN SC/D
7 --- SC/SU/SD SC/SU/SD SC/SU/S SC/SU/SD
8 --- --- --- --- SS
9 --- SS SS SS D
10 --- --- J/PF J/(P) P/J/HB
11 --- --- --- --- FAN
13 --- --- --- --- (DA)
trouble shooting Defect phenomenon and parts trouble shooting Defect phenomenon and parts
case ( 2 ) ( summarize chart ) case ( 2 ) ( how to detect problem by test pattern )
model PX50 PX500 37/42 50 37/42 50 1. When phenomenon has no image ( no show on screen either ), " whole white
phenomenon Series Series PX60 PX60 PX600 PX600 pattern " indicate and diagnostic the problem also find to close problem PCB.
thin Plasma Panel
Vertical line thick D. C ( Plasma Panel ) [ Method ]
equal space D. DG a. Turn off the main power SW.
as noise D, SC, SD b. PX600/PX60 series : disconnect DG5 connector of DG PCB.
upper SU,D, SC ( Plasma Panel ) c. After that, turn on the main power SW, it will show white pattern.
Horizontal lower SU,D, SC ( Plasma Panel )
line middle/ lower SS
all D [ diagnostic point ]
Color one color D, DG 1. white pattern show on screen : Tuner circuit or DG PCB problem.
purity D, DG 2. white pattern does not show : Plasma panel or D PCB problem
V synchro D, DG ( it may happened on SC PCB )
H synchro D, DG
Synchro V synchro shift D, DG
V Amp small D, DG Panel
BA PCB DG PCB D PCB
see duplication D, DG SC, SS
upper SU, D ( Plasma Panel ) Digital input Sw sub field scan
Screen lower SD, D ( Plasma Panel ) control video signal
half Left ----- ----- C2 D C2 D OSD mix discharge
damage Right ----- ----- C1 D C1 D HDMI input
H PCB C PCB
discharge radiation problem SC, D ( Plasma Panel ) TEST
U/V in data
1. when receive service request for screen image, utilize above chart, pattern
ext in driver
trouble shooting guide or defect picture explanation following pages.
2. These chart or explanation of cause of problem is just possibility case. Tuner circuit block Panel circuit block
and major demand . However other cause of problem will be found
in rare case. also utilize service mode function which has test pattern program in order to
3. To refer " diagnostic point " for understand to which area or PCB detect problem easily.
has problem or not.
trouble shooting Defect phenomenon and parts trouble shooting Defect phenomenon and parts
case ( 2 ) case ( 2 )
phenomenon: vertical line phenomenon: vertical line
Estimated defect PCB Estimated defect PCB
D, DG, C PCB or Plasma Panel SC, SD, SU, D PCB or Plasma Panel
Cause by Plasma Panel Cause by Plasma Panel Cause by SC PCB
thinner
vertical line
Cause by D PCB ( C 1 ) Cause by D PCB ( C 2 ) Cause by SD PCB
Noise
thick line
Cause by D PCB Cause by DG PCB Cause by D PCB
equal span
[ diagnostic point ] [ diagnostic point ]
1. To be cautioned line size thin or thick. Depending one the size, it will cause when noise shown on whole screen, it may difficult to judge and specify the cause
by Panel or D PCB. of problem. However you can review it by SU PCB or SD PCB in order to find
2. Most cases will affect by D or DG PCB for equal span. It diagnostic which PCB will be affected. Also there is case of other factor.
by Test pattern indication.
trouble shooting Defect phenomenon and parts trouble shooting Defect phenomenon and parts
case ( 2 ) case ( 2 )
phenomenon: horizontal line phenomenon: picture color problem
Estimated defect PCB Estimated defect PCB
SU, SD, SS, D PCB or Plasma Panel D, DG PCB or Plasma Panel
Cause by SU PCB ( D PCB ) Cause by D PCB ( SU ) monochrome error Cause by D PCB
Horizontal line
on upper side
Yellowish or magenta
Cause by SD PCB ( D PCB ) Cause by SS PCB Cause by DG PCB
Horizontal line
on lower side reddish or bluish
of screen
Cause by D PCB Cause by D PCB purity error Cause by D PCB
noise of Skin color problem
Horizontal line
[ diagnostic point ] [ diagnostic point ]
It can separate by phenomenon ( upper or lower ), It shows by monochrome or purity error. But color signal process IC is located
however it will cause by Plasma Panel too. on D and DG PCB. Either one has damaged ( there is case of Plasma Panel )
in case of it shows whole screen, it affected by D PCB. therefore utilize it test pattern for diagnostic.
trouble shooting Defect phenomenon and parts trouble shooting Defect phenomenon and parts
case ( 2 ) case ( 2 )
phenomenon: Syncro problem phenomenon: Screen image in Half problem
Estimated defect PCB Estimated defect PCB
D or DG PCB SD, SU, D, C, DG, BA PCB or Plasma Panel
Cause by D PCB Cause by SD PCB Cause by SU PCB
V syncro flow Screen upper or lower
half problem
Cause by D PCB Cause by D PCB
H syncro flow
( left ) screen left or right
half problem
V syncro shift
( Right 9
Cause by D PCB cause by DG PCB ( analog only ) cause by BA PCB ( digital only )
V amplitude
small ( left ) other screen problem
duplicate image
( Right )
[ diagnostic point ] [ diagnostic point ]
These explanation of synchronize problem IC are relating with 1. Depending on location of damaged screen, it can identify which PCB problem.
D PCB or DG PCB. Therefore cause by either one. upper: SU PCB, lower: SD PCB, right/left : D or C PCB.
Test pattern indication is recommended in order to make sure however it will possible to cause by Plasma Panel.
and distinguish which PCB has a problem. 2. Sub screen problem is affected by that tuner or video signal process which is
handle PCB. Then you can check by Analog or digital broadcast reception
to find out more close relation PCB.
( refer summarize chart by model )
trouble shooting Defect phenomenon and parts trouble shooting Defect phenomenon and parts
case ( 2 ) case ( 2 )
phenomenon: discharge problem phenomenon: Others
Estimated defect PCB Estimated defect PCB
SC or D PCB DG PCB
cause by SC PCB ( D PCB ) Small screen problem Cause by DG PCB
TV channel program guide show
and current TV program screen
has problem. ( ex: PX 600 case )
Whole screen
has radiation
problem OSD position wrong cause by DG PCB
OSD indication position is wrong
[ diagnostic point ]
1. Current TV program screen show on TV channel program guide,
it is controlled by DG PCB.
[ diagnostic point ] 2. OSD indicate position is made by DG PCB which is analogue data.
When voltage charge does not match on scanning electrode and writing
electrode, electric storage does not normal on inside cell of Panel.
and it does not radiate as normal operation.
therefore,
1. SC PCB what request order to scan electrode.
2. D PCB what control discharge.
those factor will consider cause of problem.