Text preview for : smcr12.pdf part of yorkville cr12 yorkville cr12 service manual
Back to : smcr12.rar | Home
SERVICE MANUAL
CR12 TYPE:YS1001
WEB ACCESS: http://www.yorkville.com
WORLD HEADQUARTERS
CANADA U.S.A.
Yorkville Sound Yorkville Sound Inc.
550 Granite Court 4625 Witmer Industrial Estate
CR12
POWER
Pickering, Ontario Niagara Falls, New York A
B
CLIP /PROTECT
CLIP /PROTECT PROFESSIONAL AUDIO AMPLIFIER
L1W-3Y8 CANADA 14305 USA POWER
Voice: (905) 837-8481 Voice: (716) 297-2920
Fax: (905) 837-8746 Fax: (716) 297-3689
Manual-Service-CR12-1v1.pdf
Quality and Innovation Since 1963
Printed in Canada
CR12.xls Parts List 10/4/2002
IMPORTANT SAFETY INSTRUCTIONS YS #
3570
Description
14 PIN SCKT CLOSED FRAME DIP ONLY
Qty. YS #
1
Description
3451 EYELET SMALL 0.089 OD PLATED
Qty.
51
YS #
5003
Description
1/4W 30K1 1% T&R RES
Qty.
2
6405 RED 3MM LED 1V7 5MA BRT 2 3868 FAN 92MM X 92MM 60CFM 24VDC ???MA 1 4840 1/4W 33K 5% T&R RES 2
6408 GRN 3MM LED 1V9 5MA FROSTED 1 3501 B52200F006 COMP WASH #4 SMALL 19 6122 1/4W 33K 5%MINI T&R RES 2
6419 BRIDGE 35A 400V WIRE LEAD GI3504 2 8500 6-32X3/4 STEEL PEM STUD 4 4908 1/4W 45K3 1% T&R RES 2
6425 BAV21 200V 0A25 DIODE T&R 12 3810 4" NYLON CABLE TIE 6 4834 1/4W 47K 5% T&R RES 4
6825 1N4148 75V 0A45 DIODE T&R 55 3827 SQUARE BUMPER BUTTON BLACK 5 6119 1/4W 47K 5%MINI T&R RES 6
6438 1N4004 400V 1A0 DIODE T&R 6 3915 ROUND BUMPER BUTTON BLACK 1 4761 1/4W 60K4 1% T&R RES 4
6934 MR854 400V 3A0 DIODE FASREC 12 8661 BUTTON KNOB FLAT GREY 1 6142 1/4W 64K9 1%MINI T&R RES 2
6459 1N4732A 4V7 1W0 ZENER 5% T&R 2 3426 8' 3/16 SJT AC LINE CORD REMOVB· CSA 1 4838 1/4W 100K 5% T&R RES 2
6454 1N5231BRL 5V1 0W5 ZENER 5% T&R 4 4000 10 CIR CABLE HOLDER .098 1 4942 1/4W 100K 5% .2"U T&R RES 2
6486 1N5244B 14V0 0W5 ZENER 5% T&R 4 5989 4 CIR CABLE HOLDER .098 2 6120 1/4W 100K 5%MINI T&R RES 15
6822 1N4745A 16V0 1W0 ZENER 5% T&R 4 8793 4-40 HEX NUT ZINC 10 5026 1/4W 143K 1% T&R RES 4
INSTRUCTIONS PERTAINING TO A RISK INSTRUCTIONS RELATIVES AU RISQUE 6432
6426
1N5248B 18V0 0W5 ZENER 5% T&R
1N5254B 27V0 0W5 ZENER 5% T&R
4
2
8760 6-32 KEPS NUT TIN PLATED
8800 6-32 KEPS NUT ZINC
32
14
4839
4886
1/4W 150K 5%
1/4W 200K 5%
T&R RES
T&R RES
5
1
OF FIRE, ELECTRIC SHOCK, DE FEU, CHOC ÉLECTRIQUE, OU 5101 BC550C TO92 NPN TRAN T&R TB 19 8797 5/16-18 KEPS NUT JS500 1 6137 1/4W 200K 5%MINI T&R RES 1
OR INJURY TO PERSONS. BLESSURES AUX PERSONNES. 5102 BC560C TO92 PNP TRAN T&R TB 12 3797 TO-247 THERMO CONDUCTIVE PAD 4 4841 1/4W 220K 5% T&R RES 2
5103 MPSA06 TO92 NPN TRAN T&R TA 4 3815 TO3 PREGREASED MICA 56-03-2AP 16 6126 1/4W 220K 5%MINI T&R RES 2
CAUTION: AVIS: 5104
5107
MPSA56
2N5551
TO92 PNP TRAN T&R TA
TO92 NPN TRAN T&R TA
2
4
3823 TO-220 THERMO PAD SMALL HOLE
3846 TO220 THERMO PAD LARGE HOLE 56359B
4
8
6145
6146
1/4W 249K 1%MINI
1/4W 392K 1%MINI
T&R RES
T&R RES
1
1
5108 2N5401 TO92 PNP TRAN T&R TA 7 4002 10 CIR WAFER W/LCK VT 0.1" 1 6143 1/4W 499K 1%MINI T&R RES 2
TO REDUCE THE RISK OF ELECTRIC SHOCK, DO AFIN DE REDUIRE LES RISQUE DE CHOC ELECTRIQUE, 5113 MPSA42 TO92 NPN TRAN T&R TA 6 4745 5.0W 0R1 5% BLK RES 8 4844 1/4W 1M 5% T&R RES 2
NOT REMOVE COVER (OR BACK). N'ENLEVEZ PAS LE COUVERT (OU LE PANNEAU 6814 MJF6668 T221D PNP TRAN DARL TJ 1 2007 1/4W 1R 5%FLAME PROOF T&R RES 10 4820 1/4W 1M5 5% T&R RES 2
NO USER SERVICEABLE PARTS INSIDE. ARRIERE). NE CONTIENT AUCUNE PIECE REPARABLE 6815 MJF6388 T221D NPN TRAN DARL TJ 2 4682 1/2W 1R 5%PHILIPS SMAL T&R RES 5 3623 17" 4C-26AWG RIBBON CABLE 0.1" 1
PAR L'UTILISATEUR. 6873 MJE340 TO126 NPN TRAN TG 6 4911 1/4W 2R2 5% T&R RES 8 4001 8.5"10C-26AWG RIB 1 W/LCK HDR 098 1
6874 MJE350 TO126 PNP TRAN TG 6 4748 2.0W 3R9 5% T&R 2 3622 14" 14C-28AWG DIP HDR CABLE .05" 1
REFER SERVICING TO QUALIFIED CONSULTEZ UN TECHNICIEN QUALIFIE 6752 MTP10N15L TO220 NCH MFET TN 2 4733 5.0W 5R6 5% BLK RES 2 3699 RELAY 1C 02AMP DC48 006MA PC-S 1
6933 MTP23P06 TO220 PCH MFET TN 2 2010 1/8W 10R0 2%FLAME PROOF T&R RES 5 3735 RELAY 1A 16AMP DC48 011MA PC-C 1
SERVICE PERSONNEL. POUR L'ENTRETIENT. 6909 MJ21196 TO3 NPN TRAN TH 8 4875 1/4W 10R 5% T&R RES 3 8742 4-40 X 3/8 PAN PH TAPTITE JS500 7
6989 MJL1302A TO3P PNP TRAN TK 2 4930 1/4W 10R 5% .2"U T&R RES 1 8861 4-40 X 3/8 PAN PH MS JS500 2
6990 MJL3281A TO3P NPN TRAN TK 2 2011 1/4W 11R3 1%FLAME PROOF T&R RES 2 8741 4-40 X 1/2 PAN PH MS JS500 10
6910 MJ21195 TO3 PNP TRAN TH 8 2013 1/8W 22R1 1%FLAME PROOF T&R RES 2 8827 4-40 X 1/2 FLAT PH TAPTITE JS500 4
6840 MC33078P IC DUAL OP AMP 4 2016 1/8W 39R 2%FLAME PROOF T&R RES 18 8799 #6 X 1/4 PAN PH TYPE B JS500 2
Read Instructions: Veuillez lire le manuel: 6882 TL072CP IC FET DUAL OP AMP 1 4817 1/4W 47R 5% T&R RES 2 8832 6-32 X 1/4 PAN PH TAPTITE JS500 4
The Owner's Manual should be read and understood Il contient des informations qui devraient êtres comprises avant 6889 TL074CN IC QUAD O/A T.I ONLY 1 4637 1/8W 68R 5% T&R RES 3 8807 6-32 X 5/16 PAN PH MS JS500 3
6745 LM13600N IC XCONDUCTANCE AMP 1 4811 1/4W 68R 5% T&R RES 6 8801 6-32 X 3/8 PAN PH TAPTITE JS500 12
before operation of your unit. Please, save these l'opération de votre appareil. Conservez S.V.P. ces instructions
6444 MAC224-4 TO220 40A TRIAC 200V 2 2018 1/8W 75R 2%FLAME PROOF T&R RES 6 8829 6-32 X 3/8 FLAT PH TAPTITE BO#4 HEA 23
instructions for future reference. pour consultations ultérieures 6467 10K 10% THERMISTOR NTC TO-92 2 4912 1/4W 75R 5% T&R RES 2 8761 6-32 X 1/2 PAN PHIL MS ZINC CLEAR 16
Packaging: Emballage: 6489
5200
5R0 20% NTC THERMISTOR-SURGTR
_10P 200V 5%CAP T&R RAD CER.2"NPO
1
4
2019 1/8W 100R0 1%FLAME PROOF T&R RES
4602 1/8W 100R 5% T&R RES
2
2
8806
8828
6-32 X 1/2 PAN PH TAPTITE JS500
6-32 X 3/4 PAN PH TAPTITE JS500
2
7
Keep the box and packaging materials, in case the unit Conservez la boite au cas ou l'appareil devait être 5817 _15P 100V 2%CAP T&R RAD CER.2"NPO 2 4859 1/4W 150R 5% T&R RES 4 8809 10-32 X 1/4 PAN PH TAPTITE JS500 4
needs to be returned for service. retourner pour réparation. 5277 220P 200V 5%CAP T&R RAD CER.2"NPO 4 2023 1/8W 220R0 1%FLAME PROOF T&R RES 3 8762 10-32 X1/2 TRUSS QUAD TAPTITE JS500 15
Warning: Warning: 5211
5206
330P 100V 5%CAP T&R RAD CER.2"NPO
__1N 400V 5%CAP T&R RAD .2"FLM
8
6
4977 1/4W 220R 5%MINI T&R RES
2024 1/8W 249R 2%FLAME PROOF T&R RES
1
9
8780
3663
5/16-18X3 3/4 CARRIAGE BOLT ZINC
SNAP IEC PWR SOC W/.250TAB FOR .060
1
1
When using electric products, basic precautions should Attention: Lors de l'utilisation de produits électrique, 5273 __1N5 200V 5%CAP T&R RAD CER.2"NPO 4 4770 1/4W 249R 1% T&R RES 15 3752 SNAP IN 1/4 SPACER RICHCO 4
always be followed, including the following: assurez-vous d'adhérer à des précautions de bases 5276 __3N3 200V 5%CAP T&R RAD CER.2"NPO 4 4621 1/2W 470R 5% T&R RES 2 8656 .171 X 1/4 NYLON SPACER #SP42 2
Power Sources: incluant celle qui suivent: 5209 __4N7 250V 5%CAP T&R RAD .2"FLM 4 4980 1/4W 470R 5%MINI T&R RES 12 3744 SNAP IN .375 SPACER RICHCO 4
6451 __4N7 250V 20%CAP BLK 'Y' 10MM AC 1 4758 1/4W 953R 1% T&R RES 4 3741 .5 SPACER ID-.171 OD-.25 #912-500 2
Your unit should be connected to a power source only of the Alimentation: 5204 _10N 100V 10%CAP T&R RAD .2"FLM 4 4823 1/4W 1K 5% T&R RES 1 8657 6-32 X 3/8" HEX SPACER ALUMINUM 1
voltage specified in the owners manual or as marked on the unit. L'appareil ne doit être branché qu'à une source d'alimentation 5210 _22N 100V 10%CAP T&R RAD .2"FLM 4 4934 1/4W 1K 5% .2"U T&R RES 1 8667 SHOULDER WASHER SWS-229 LENGTH 1/8 4
This unit has a polarized plug. Do not use with an extension cord or correspondant au voltage spécifié dans le manuel ou tel qu'indiqué 5840 _22N 400V 10%CAP BLK RAD POLY FLM 3 4981 1/4W 1K 5%MINI T&R RES 14 3524 NYLON SH/WASHER ID385 OD750 T060 2
receptacle unless the plug can be fully inserted. Precautions should sur l'appareil. Cet appareil est équipé d'une prise d'alimentation 6435 _22N 275V 20%CAP BLK 'X2' 15MM AC 1 5037 5.0W 1K2 5% STANDOFF BLK RES 4 3577 FIBER WASHER .625OD .380ID .03 2
be taken so that the grounding scheme on the unit is not defeated. polarisée. Ne pas utiliser cet appareil avec un cordon de 5228 100N 100V 5%CAP T&R RAD .2"FLM 6 4935 1/4W 1K5 5% .2"U T&R RES 1 3436 DPDT PUSH SW PCMT H BREAK B4 MAKE 1
Hazards: raccordement à moins qu'il soit possible d'insérer complètement les 5314
5231
100N 50V 10%CAP T&R BEAD
220N 63V 10%CAP T&R RAD .2"FLM
X7R 1
6
4988 1/4W 1K5 5%MINI
4791 1/4W 1K54 1%
T&R RES
T&T RES
5
2
3587
3705
DPDT ROKR SW QUIK 250"AC/PWR ON-OFF
4P3T SLID SW PCMT H
1
1
Do not place this product on an unstable cart, stand, tripod, bracket or trois lames. Des précautions doivent êtres prises afin d'eviter que le
5882 220N 250V 10%CAP BLK RAD POLY FLM 4 6144 1/4W 1K91 1%MINI T&R RES 2 1328 CR12 120VAC 60HZ T'RD 1
table. The product may fall, causing serious personal injury and serious système de mise à la terre de l'appareil ne soit désengagé.
5257 __2U2 63V 20%CAP T&R RAD .2"EL 4 6113 1/4W 2K 5%MINI T&R RES 4
damage to the product. Use only with cart, stand, tripod, bracket, or table Hazard: 5259 __4U7 63V 20%CAP T&R RAD .2"EL 6 5006 1.0W 2K7 5% T&R RES 4
recommended by the manufacturer or sold with the product. Follow the Ne pas placer cet appareil sur un chariot, un support, un trépied ou une 5281 _10U 16V 20%CAP T&R RAD .2"NP 3 6206 1/4W 3K01 1% T&R RES 2
manufacturer's instructions when installing the product and use mounting table instables. L'appareil pourrait tomber et blesser quelqu'un ou subir des 5629 _10U 160V 20%CAP BLK 10X13MM EL 4 6136 1/4W 3K3 5%MINI T&R RES 6
accessories recommended by the manufacturer. dommages importants. Utiliser seulement un chariot, un support, un trépied 5260 _22U 50V 20%CAP T&R RAD .2"EL 14 5028 1/4W 3K74 1% T&R RES 5
The apparatus should not be exposed to dripping or splashing ou une table recommandés par le fabricant ou vendus avec le produit. 5961 _33U 16V 20%CAP T&R RAD .2"NP 6 4827 1/4W 4K7 5% T&R RES 3
water; no objects filled with liquids should be placed on the 5880 100U 35V 20%CAP T&R .2"EL 1 4943 1/4W 4K7 5% .2"U T&R RES 1
Suivre les instructions du fabricant pour installer l'appareil et utiliser les
apparatus. 5897 _330U 16V 20%CAP BLK 08X11MM EL 6 4982 1/4W 4K7 5%MINI T&R RES 15
accessoires recommandés par le fabricant.
5895 6800U 63V 20%CAP BLK 25X50MM ELS 8 4639 1/4W 4K99 1% T&R RES 4
Terminals marked with the "lightning bolt" are hazardous live; Il convient de ne pas placer sur l'appareil de sources de flammes 4497 _10K B LIN 9MM HORIZONTAL P29 2 6141 1/4W 5K6 5%MINI T&R RES 4
the external wiring connected to these terminals require installation nues, telles que des bougies allumées. 4522 __4K7 TRIM POT 2 4887 1/4W 7K5 5% T&R RES 6
by an instructed person or the use of ready made leads or cords. L'appeil ne doit pas être exposé à des égouttements d'eau ou des 2432 8.0 AMP CIRCUIT BREAKER 1 5027 1/4W 9K09 1% T&R RES 2
No naked flame sources, such as lighted candles, should be éclaboussures et qu'aucun objet rempli de liquide tel que des vases 711 30 X 50 X 1.5MIL PLASTIC BAG 1 4629 1/2W 10K 5% T&R RES 4
placed on the apparatus. ne doit être placé sur l'appareil. 3820 ___4UH COIL 14AWG ZOBEL HORIZONTAL 2 4800 1/4W 10K0 1% T&R RES 2
Power Cord: Les dispositifs marqués d'une symbole "d'éclair" sont des parties 3489 CLIP 250X032 18-22AWG DISCO/INSL 17 4940 1/4W 10K 5% .2"U T&R RES 1
The AC supply cord should be routed so that it is unlikely that it will dangereuses au toucher et que les câblages extérieurs connectés à 3490 CLIP 250X032 14-16AWG DISCO/INSL 5 4983 1/4W 10K 5%MINI T&R RES 5
ces dispositifs de connection extérieure doivent être effectivés par un 3602 RING TERMINAL 18AWG WIRE & #8 SCREW 1 6116 1/4W 10K0 1%MINI MF T&R RES 13
be damaged. If the AC supply cord is damaged DO NOT
opérateur formé ou en utilisant des cordons déjà préparés. 3618 STAR RING TERMINAL14-16AWG #10SCREW 4 5008 1/4W 14K7 1% T&R RES 4
OPERATE THE UNIT. 3682 250 MALE PCB TAB REEL 24 4830 1/4W 15K 5% T&R RES 4
Service: Cordon d'alimentation: 3410 RED ON LEFT DUAL BINDING POST TPP5 1 4979 1/4W 15K 5%MINI T&R RES 3
The unit should be serviced only by qualified service personnel. Évitez d'endommager le cordon d'alimentation. N'UTILISEZ PAS 3415 RED ON RIGHT DUAL BINDING POST TPP5 1 4771 1/4W 17K8 1% T&R RES 6
L'APPAREIL si le cordon d'alimentation est endommagé. 3924 1/4" JCK PCB MT VERT 2XTIP HICURNT 2 6123 1/4W 20K0 1%MINI MF T&R RES 2
Service: 3417
3405
6-32 SCREW TERMINAL PC MOUNT 5 POS
TERMINAL STRIP 5P #6 SCREW
3
1
4777 1/4W 21K5 1%
5024 1/4W 22K6 1%
T&R RES
T&R RES
2
1
Consultez un technicien qualifié pour l'entretien de votre appareil. 3416 1/4"&XLR PCB MT VERT COMBO 2 6129 1/4W 27K 5%MINI T&R RES 2
SAFE_V4.doc Version 4.0 02/11/99 11:54 AM
P:\M1183SCH.PRN
P:\M1183SCH.PRN
+17V
(6=V-,11=V+)
LM13600 4
5 1/2 2
R6 U3 D
IG IABC 3 R12
4K99 1 249R R42 C25 R41 LIMITER LEDA
25V LEDB C22
S R1 R2 7K5 150K R46 R51
C4 R14 R13 4U7 6 25V
XLR-PHONE R16 LIMITER 150K 4U7 7K5
T 953R 3K74 330P 150K 249R 4148 OUT
1/4"HALF +XLR R7 2 5 3
C1 13 TPA 1 D1 15K IN D24 D23
CHANNEL_A R
21K5 Q5 4
4148 4148 OUT
JB2 330P 14 3 U1 2
R15 C5 C6 MPSA56 SW2 4148 4148 1K IN 15K D2
12 U1 TP 1/4 SG_A C31 D22