Text preview for : Acc_Cables.pdf part of Keithley Acc Cables Keithley Cables Acc_Cables.pdf



Back to : Acc_Cables.pdf | Home

Cables
TErMINaTIoNs lENGTH
Model Description Type from To m ft usE WITH:
236-ILC-3 Safety Interlock Shielded twisted pair 3-pin round 3-pin round 3 10 4200-SCS, 8007, 8008
Series 2200, Series 2600B, 4200-PA, 6220,
237-ALG-2 Low Noise Input Triax 3-slot male triax Alligator clips (3) 2 6 .6
6221, 6482, 6487, 6514, 6517A, 6517B
Series 2200, Series 2600B, 4200-PA, 6220,
237-ALG-15 Low Noise Input Triax 3-slot male triax Alligator clips (3) 15 50
6221, 6482, 6487, 6514, 6517A, 6517B
248-MHV High Voltage Coax SHV female MHV male 3 10 248
248-SHV High Voltage Coax SHV female SHV female 3 10 248, CS-970
2000-MTC-2 Cable Assembly Shielded twisted pair DB44 female Unterminated 2 6 .6 2000-20
Shielded multiple
2000-MTCD-2 Cable Assembly DB44 female DB50 male 2 6 .6 2000-SCAN-20
conductors
2600-ALG-2 Low Noise Input Triax 3-slot male triax Alligator clips (3) 2 6 .6 2635B, 2636B, 4200-PA
2651A-KIT-1 Cable Assembly Coax 2-pin plug 2-pin plug 1 3 .3 2651A, 8011
2651A-KIT-2 Cable Assembly Coax 2-pin plug 2-pin plug 2 6 .6 2651A, 8011
2651A-KIT-3 Cable Assembly Coax 2-pin plug 2-pin plug 3 10 2651A, 8011
2107-4 Input Cable Shielded twisted pair LEMO Copper spade lugs (4) 1 .2 4 2182A
2107-30 Input Cable Shielded twisted pair LEMO Copper spade lugs (4) 9 .1 30 2182A, Series 2200
2107-50 Input Cable Shielded twisted pair LEMO Copper spade lugs (4) 15 50 2182A, Series 2200
3720-MTC-1.5 Mass Terminated Assembly Twisted pair D-sub female 78-pin D-sub male 1 .5 5 3720, 3723, 3724
Cables




Cables
3720-MTC-3 Mass Terminated Assembly Twisted pair D-sub female 78-pin D-sub male 3 10 3720, 3723, 3724
3721-MTC-1.5 Mass Terminated Assembly Twisted pair D-sub female 50-pin D-sub male 1 .5 5 3721, 3730, 3731, 3740, 3750
3721-MTC-3 Mass Terminated Assembly Twisted pair D-sub female 50-pin D-sub male 3 10 3721, 3730, 3731, 3740, 3750
3722-MTC-1.5 Mass Terminated Assembly Twisted pair D-sub male 104-pin D-sub female 1 .5 5 3722
3722-MTC-1.5/MM Mass Terminated Assembly Twisted pair D-sub male 104-pin D-sub male 1 .5 5 3722
3722-MTC-3 Mass Terminated Assembly Twisted pair D-sub male 104-pin D-sub female 3 10 3722
3722-MTC-3/MM Mass Terminated Assembly Twisted pair D-sub male 104-pin D-sub male 3 10 3722
3732-MTC-1.5 Mass Terminated Assembly Twisted pair D-sub female 78-pin D-sub male 1 .5 5 3732
3732-MTC-3 Mass Terminated Assembly Twisted pair D-sub female 78-pin D-sub male 3 10 3732
4200-MTRX-1 Ultra Low Noise SMU triax Miniature male 3-slot male 1 3 .2 4200-SCS
4200-MTRX-2 Ultra Low Noise SMU triax Miniature male 3-slot male 2 6 .5 4200-SCS
4200-MTRX-3 Ultra Low Noise SMU triax Miniature male 3-slot male 3 9 .8 4200-SCS
4200-PRB-C Cable Assembly Y adapter cable Female SMA 2 female SSMC 4200-PIV, 4210-CVU
4200-RPC-0.3 Cable Assembly Remote PreAmp DB15 DB15 0 .3 1 4200-PA
4200-RPC-2 Cable Assembly Remote PreAmp DB15 DB15 2 6 .5 4200-PA
4200-RPC-3 Cable Assembly Remote PreAmp DB15 DB15 3 9 .8 4200-PA
4200-RPC-6 Cable Assembly Remote PreAmp DB15 DB15 6 19 .6 4200-PA
4200-TRX-0.3 Ultra Low Noise PreAmp triax 3-slot male 3-slot male 0 .3 1ft 4200-PA
4200-TRX-1 Ultra Low Noise PreAmp triax 3-slot male 3-slot male 1 3 .2 4200-PA
4200-TRX-2 Ultra Low Noise PreAmp triax 3-slot male 3-slot male 2 6 .5 4200-PA
4200-TRX-3 Ultra Low Noise PreAmp triax 3-slot male 3-slot male 3 9 .8 4200-PA
4801 Low Noise Input Coax Male BNC Male BNC 1 .2 4 6482, 6485, 7158
4802-10 Low Noise Input Coax Male BNC Unterminated 3 10 6482, 6485, 7158
4803 Low Noise Cable Kit Coax Male BNC (10) Female BNC (5) 15 .2 50 6482, 6485, 7158
6011 Input Leads Triax 2-slot male triax Alligator clips (3) 1 .5 5 Instruments with 2-slot triax connectors
6011-10 Input Leads Triax 2-slot male triax Alligator clips (3) 3 10 Instruments with 2-slot triax connectors
6517-ILC-3 4-pin Interlock Cable Shielded 4-pin female DIN 4-pin female DIN 1 3 .3 6517A, 8009
6517B-ILC-3 Interlock Cable Shielded 4-pin Phoenix 4-pin DIN 1 3 .3 6517B, 8009
7009-5 Shielded RS-232 Shielded Male DB-9 Female DB-9 1 .5 5 All RS-232 capable instruments
7011-MTC-1 Mass Terminated Assembly Twisted pair (45) 96-pin female 96-pin female 1 3 .3 7011-C, 7012-C, 7013-C, 7015-C, 7018-C
7011-MTC-2 Mass Terminated Assembly Twisted pair (45) 96-pin female 96-pin female 2 6 .6 7011-C, 7012-C, 7013-C, 7015-C, 7018-C
Shielded banana plug
7019C-MTCI-2 Kelvin Instrument Cable Shielded twisted pair Card connector 2 6 .6 Series 2400
cables (6)
ACCESSORIES




7020-MTC-2 Mass Terminated Assembly Twisted pair (45) 96-pin female 96-pin female 2 6 .6 7020
7024-3 Low Noise Triax 2-slot male triax 2-slot male triax 0 .9 3 Instruments with 2-slot triax connectors
7024-10 Low Noise Triax 2-slot male triax 2-slot male triax 3 10 Instruments with 2-slot triax connectors
7025-10 Low Noise Input Triax 2-slot male triax Unterminated 3 10 Instruments with 2-slot triax connectors
7035-MTC-2 Mass Terminated Assembly Twisted pair (45) 96-pin female 96-pin female 2 6 .6 7035
7036-MTC-2 Mass Terminated Assembly Twisted pair (45) 96-pin female 96-pin female 2 6 .6 7036
7051-* BNC Interconnect Coax BNC BNC 2015, 2016, 3390




1.888.KEITHLEY (U.S. only)
www.keithley.com
A Greater Measure of Confidence
Cables
TErMINaTIoNs lENGTH
Model Description Type from To m ft usE WITH:
7078-DIN 707A Master/Slave Twisted pair (9) 8-pin DIN 8-pin DIN 1 .8 6 707A
7078-MTC-5 Mass Terminated Assembly Twisted pair (12) 38-pin connector 38-pin connector 1 .5 5 7071, 7071-4, 7074-D
7078-MTC-20 Mass Terminated Assembly Twisted pair (12) 38-pin connector 38-pin connector 6 .1 20 7071, 7071-4, 7074-D
7078-TRX-1 Low Noise Triax 3-slot male triax 3-slot male triax 0 .3 1 2635B, 2636B, 6482, 6487, 6514, 6517A, 6517B, 7072, 7174A
7078-TRX-3 Low Noise Triax 3-slot male triax 3-slot male triax 0 .9 3 2635B, 2636B, 6482, 6487, 6514, 6517A, 6517B, 7072, 7174A
7078-TRX-5 Low Noise Triax 3-slot male triax 3-slot male triax 1 .5 5 2635B, 2636B, 6482, 6487, 6514, 6517A, 6517B, 7072, 7174A
7078-TRX-10 Low Noise Triax 3-slot male triax 3-slot male triax 3 10 2635B, 2636B, 6482, 6487, 6514, 6517A, 6517B, 7072, 7174A
7078-TRX-12 Low Noise Triax 3-slot male triax 3-slot male triax 4 12 2635B, 2636B, 6482, 6487, 6514, 6517A, 6517B, 7072, 7174A
7078-TRX-20 Low Noise Triax 3-slot male triax 3-slot male triax 6 .1 20 2635B, 2636B, 6482, 6487, 6514, 6517A, 6517B, 7072, 7174A
7078-TRX-6IN Low Noise Triax 3-slot male triax 3-slot triax 0 .15 0 .5 6430
7152-MTC-2 Low Noise Matrix Expansion Triax (5) 6-pin M-series coax 6-pin M-series coax 0 .6 2 7152
7152-MTC-10 Low Noise Matrix Expansion Triax (5) 6-pin M-series coax 6-pin M-series coax 3 10 7152
7152-TRX-10 Low Noise M-Series to Triax Triax (5) M-series connector 3-slot triax (5) 3 10 7152, 8006
7153-TRX Low Noise M-Series to Triax Triax (5) M-series connector 3-slot triax (5) 2 6 7153
7173-50-CSEP 4-cable Set Coax SMB female BNC male 0 .6 2 7173-50
7705-MTC-2 Mass Terminated Assembly Twisted pair (25) D-sub male D-sub female 2 6 .6 7703, 7705, 7707, 7709
7711-BNC-SMA 5 SMA to BNC Cables Coax SMA Male BNC Female 0 .15 0 .5 7711
Cables




Cables
7712-SMA-1 SMA Cables Coax SMA Male SMA Male 1 3 .3 7711, 7712, System 46, System 46T
7754-3 BNC Coax BNC Male Alligator clips 0 .9 3 Instruments with 2-slot BNC connectors
8007-GND-3 Safety Ground Wire Single wire Crimp lug Crimp lug 3 10 8007
Multiple terminations:
8542-301 LIV Cable Multiple conductor DB9 female Triax (2500), 2 dual 1 .8 6 2500, Series 2400, System 25, 8544, 8544-TEC
bananas (24XX) GND wire
8607 1kV Test Cables Single wire (2) Safety banana Safety banana 1 3 .3 2410, 6487, 6517A, 6517B
CA-18-1 Shielded Coax Dual banana plug Dual banana plug 1 .2 4 Binding post inputs
CA-19-2 RG58 RG58 BNC male BNC male 1 .5 5 4200-SCS
CA-126-1A Digital I/O Shielded DB25 male DB25 female 1 .5 5 Series 2600B, Series 3700A
Series 2600B, 2701, 3390, Series 3700A,
CA-180-3A Crossover Cable Twisted pair RJ45 RJ45 3 10
6221, all TSP-enabled instruments
8-position Phoenix
CA-321-1 Temperature Control Cable Multiple conductor DB15 female 1 .8 6 2510, 8544
(CS-846 equivalent)
Dual Temperature Control Y cable to two 8-position
CA-322-1 Multiple conductor DB15 female 1 .8 6 2510, 8544, 8544-TEC
Cable Phoenix (CS-846)
CA-404B RG188 Coax SMA male SMA male 2 6 .5 4200-SCS
CA-405B RG188 Coax SMA male SMA male 0 .15 0 .5 4200-SCS
CA-406B RG188 Coax SMA male SMA male 0 .33 1 .08 4200-SCS
CA-446A Cable Assembly Coax SMA male SMA male 3 9 .8 4210-CVU
CA-447A Cable Assembly Coax SMA male SMA male 1 .5 5 4210-CVU
CA-451A RG188 Coax SMA male SMA male 0 .108 0 .35 4200-SCS
CA-452A RG188 Coax SMA male SMA male 0 .203 8 in. 4200-SCS
CA-557-1A Cable Assembly Multiple conductor 8-pin receptacle 8-pin receptacle 1 3 .3 2651A, 8011
CA-557-2A Cable Assembly Multiple conductor 8-pin receptacle 8-pin receptacle 2 6 .6 2651A, 8011
CA-557-3 Cable Assembly Multiple conductor 8-pin receptacle 8-pin receptacle 3 10 2651A, 8011
3 .3, 6 .6,
CA-558-x Interlock Cable Twisted pair (2) 25-pin D-sub 3-pin 1, 2, 3 Series 2600B, 2657A
10
CA-559-0A Black Banana Jumper Jumper Banana Banana 0 .102 4 in . 8010
CA-559-2A Red Banana Jumper Jumper Banana Banana 0 .102 4 in . 8010
CA-560-0A Banana Plug Jumper Cable Jumper Banana Banana 0 .203 8 in . 8010
CA-560-2A Banana Plug Jumper Cable Jumper Banana Banana 0 .203 8 in . 8010
CA-561-0A Black Banana Jumper Jumper Banana Banana 0 .203 8 in . 8010
CA-561-2A Red Banana Jumper Jumper Banana Banana 0 .203 8 in . 8010
ACCESSORIES


Black Safety Banana Plug
CA-562-0B Jumper Banana Banana 0 .254 10 in . 8010
Jumper Cable
Red Safety Banana Plug
CA-562-2B Jumper Banana Banana 0 .254 10 in . 8010
Jumper Cable
CA-563C BNC to Banana Jumper Jumper Bnc Banana 0 .241 9 .5 in . 8010
CA-567-0A Black Banana Jumper Jumper Banana Banana 0 .203 8 in . 8010
CA-567-2A Red Banana Jumper Jumper Banana Banana 0 .203 8 in . 8010
CA-568-XA Protective Earth Ground Safety Eye lug Eye lug 0 .3, 0 .45, 3 1, 1 .5, 10 8010




1.888.KEITHLEY (U.S. only)
www.keithley.com
A Greater Measure of Confidence
Cables


TErMINaTIoNs lENGTH
Model Description Type from To m ft usE WITH:
0 .5, 1, 1 .6, 3 .2,
HV-CA-554-x 3kV Rated High voltage Triax Triax 8010, 2657A
2, 3 6 .6, 10
HV-CA-571-3 High Voltage Triax Triax Unterminated 2657A
S46-SMA-0.5 SMA Cable Coax SMA Male SMA Male 0 .15 0 .5 7711, 7712, System 46, System 46T
S46-SMA-1 SMA Cable Coax SMA Male SMA Male 0 .30 1 .0 7711, 7712, System 46, System 46T
SC-9 Low Noise Coax Unterminated Unterminated Sold by the foot
SC-22 Low Noise Triax Unterminated Unterminated Sold by the foot CS-631
SC-93 Low Thermal Shielded Unterminated Unterminated Sold by the foot 2182-KIT
SC-182 Low Inductance Coax Unterminated Unterminated Sold by the foot 2302, 2303, 2303-PJ, 2304A, 2306, 2306-PJ
SC-200A General Purpose Shielded twisted pair Unterminated Unterminated Sold by the inch Series 2600B
SC-206 High Current Coax Cable Coax Unterminated Unterminated Sold by the inch 2651A
1, 2, 3 .2, 6 .6,
SHV-CA-553-x 3kV Rated High voltage Triax SHV 2657A
3 10
Cables




Cables
Model 248-MHV: 3m (10 ft) of RG-8A/U coax Model 2000-MTC-2 Cable Assembly: 2-meter
cable terminated with a SHV female connec- cable with a 44-pin connector on one end that is
Model 236-ILC-3 Safety Interlock Cable: designed to mate with the 2000-20 scanner card .
Designed to connect the lid interlock circuit of tor on one end and a MHV male connector on
the other . Maximum operating voltage (rms) The other end is unterminated for direct connec-
the Models 8007 and 8008 test fixtures to the tion to measurement fixtures or devices .
interlock circuit of the Model 237 SMU and 486 is 5,000V .
and 487 Picoammeters . for use with: 248 for use with: 2000-20
for use with: 4200-sCs, 8007, 8008




Model 248-SHV: 3m (10 ft) of RG-8A/U coax
cable terminated with a SHV female connector
Model 237-ALG-*: Low noise triax cable (SC-22) on both ends . Maximum operating voltage (rms)
terminated with a 3-slot male triax connector on is 5,000V . Model 2000-MTCD-2 Cable Assembly: 2-meter
one end and 3 alligator clips on the other .
ACCESSORIES




for use with: 248 and Cs-970 cable with a 44-pin connector on one end that
237-ALG-2 2m (6 .6 ft) length
is designed to mate with the 2000-SCAN-20
237-ALG-15 15m (50 ft) length
scanner card . The other end is equipped with a
for use with: series 2200, series 2600b, 50-pin D-sub male connector .
4200-Pa, 6220, 6221, 6487, 6514, 6482,
6517a, 6517b for use with: 2000-sCaN-20




1.888.KEITHLEY (U.S. only)
www.keithley.com
A Greater Measure of Confidence
Cables




Model 3722-MTC-*: 104-pin D-sub male to
104-pin D-sub female cable .
Model 2651A-KIT-*: High current, low impe-
dance, coaxial cable assembly . 3722-MTC-1.5: 1 .5m (5 ft) length
Model 2107-* Low-Thermal Input Cables with
Spade Lugs: An input cable terminated with a 2651A-KIT-1: 1m (3 .3 ft) . 3722-MTC-3: 3m (10 ft) length
LEMO connector on one end and four copper 2651A-KIT-2: 2m (6 .6 ft) . for use with: 3722
Cables




Cables
spade lugs on the other .
2651A-KIT-3: 3m (10 ft) .
2107-4 1 .2m (4 ft) length
2107-30 9 .1m (30 ft) length for use with: 2651a, 8011
2107-50 15m (50 ft) length
for use with: 2182a, series 2200




Model 3722-MTC-*/MM: 104-pin D-sub male to
104-pin D-sub male cable .
Model 3720-MTC-*: 78-pin D-sub female to 3722-MTC-1.5/MM: 1 .5m (5 ft) length
78-pin D-sub male cable . 3722-MTC-3/MM: 3m (10 ft) length
3720-MTC-1.5: 1 .5m (5 ft) length for use with: 3722
3720-MTC-3: 3m (10 ft) length
Model 2600-ALG-2: 2m (6 .6 ft) cable terminated for use with: 3720, 3723, 3724
with a 3-slot male triax connector on one end
and 3 alligator clips on the other .
for use with: 2635b, 2636b, 4200-Pa




Model 3732-MTC-*: 78-pin D-sub female to
78-pin D-sub male cable .
Model 3721-MTC-*: 50-pin D-sub female to 3732-MTC-1.5: 1 .5m (5 ft) length
50-pin D-sub male cable . 3732-MTC-3: 3m (10 ft) length
3721-MTC-1.5: 1 .5m (5 ft) length for use with: 3732
3721-MTC-3: 3m (10 ft) length
ACCESSORIES



for use with: 3721, 3730, 3731, 3740, 3750




1.888.KEITHLEY (U.S. only)
www.keithley.com
A Greater Measure of Confidence
Cables




Model 4200-RPC-*: Remote PreAmp cable
terminated at each end with a high density
DB15 connector . This cable connects a Model
Model 4200-MTRX-*: Ultra low noise SMU triax 4200-SMU or 4210-SMU source measurement
cable is terminated with a miniature male triax Model 4801 Input Cable: Low noise coax cable,
unit installed in a Model 4200-SCS to a remotely
connector on one end and a standard 3-slot 1 .2m (48 in) in length, with male BNC connec-
mounted Model 4200-PA PreAmp .
tors on each end .
Cables




Cables
male triax connector on the other end . This 4200-RPC-0.3: 0 .3m (1 ft) (for use inside prober
cable connects a Model 4200-SMU or 4210-SMU shield) for use with: 6482, 6485, 7158
source measurement unit installed in a Model
4200-SCS to a test fixture . (4200-MTRX-* cables 4200-RPC-2: 2m (6 .5 ft) (one included with each
are intended only for connection to an SMU that 4200-PA)
does not have a 4200-PA PreAmp installed .) 4200-RPC-3: 3m (9 .8 ft)
4200-MTRX-1: 1m (3 .2 ft) 4200-RPC-6: 6m (19 .6 ft)
4200-MTRX-2: 2m (6 .5 ft) (two included with for use with: 4200-Pa
each 4200-SCS SMU not configured with a
4200-PA Remote PreAmp)
4200-MTRX-3: 3m (9 .8 ft)
for use with: 4200-sCs

Model 4802-10: 3m (10 ft) of low noise coax
cable with male BNC connector at one end and
unterminated at the other .
for use with: 6482, 6485, 7158




Model 4200-TRX-*: Ultra low noise PreAmp
triax cable terminated with a standard 3-slot
male triax connector on each end . This cable
connects a Model 4200-PA PreAmp option
Model 4200-PRB-C: SMA to SSMC Y adapter installed in the Model 4200-SCS to the
cable with local ground that connects the test fixture .
4200-PIV package to DC probe manipulators .
The cable is terminated at one end with a single 4200-TRX-0.3: 0 .3m (1 ft) (recommended for
female SMA . The other end splits into two remote location of the 4200-PA)
gold SSMC plugs (female connectors) and a 4200-TRX-1: 1m (3 .2 ft)
black wire with integrated connector, which is 4200-TRX-2: 2m (6 .5 ft) (two included with each
used to connect to the shield of another Model Model 4200-PA)
4200-PRB-C cable .
ACCESSORIES




4200-TRX-3: 3m (9 .8 ft)
for use with: 4200-PIV, 4210-CVu
for use with: 4200-Pa
Model 4803 Low Noise Cable Kit: Includes
15m (50 ft) of low noise coax cable, 10 male BNC
connectors, and 5 female BNC chassis-mount
connectors .
for use with: 6482, 6485, 7158


1.888.KEITHLEY (U.S. only)
www.keithley.com
A Greater Measure of Confidence
Cables




2 slot Triax 2
0
7
Model 7019C-MTCI-2 6-wire Kelvin Extender
Model 6011 2-slot Triax Cable: 1 .5m (5 ft) of and Instrument Cable: Used with Model
triax cable (SC-22) terminated with a 2-slot triax 7019-C 6-Wire Ohms Matrix Card and a
Cables




Cables
plug on one end and three alligator clips on the Model 7009-5 Shielded RS-232 Cable: 1 .5m SourceMeter SMU instrument . The SourceMeter
other . Also available in 3m (10 ft) length (Model (5 ft) RS-232 cable with a male DB-9 connector cables are 0 .6m (2 ft) long and the DUT cables
6011-10). at one end and a female DB-9 connector on the are 2m (6 .6 ft) long . The cable set is used in a
for use with instruments with 2-slot triax other end . Wired as a straight through, not as a basic system to test a resistor network .
connectors null modem cable .
for use with: series 2400 sourceMeter sMu
for use with: all rs-232 capable instruments Instruments




Model 6517-ILC-3 Interlock Cable: Designed to
connect the Interlock of the 6517A with the 8009
test fixture . Configuring the 6517A with the 8009
test fixture results in all the electrode constants
already being programmed into the unit .
Model 7020-MTC-2: 2m (6 .6 ft) mass terminated
for use with: 6517a Electrometer, 8009
cable assembly for connection to 7020 . The
Model 7011-MTC-x: Mass terminated cable cable has 45 pairs with outer shield . The cable is
assembly for connection to 7011-C and other terminated at each end with 96-pin female DIN
switching cards . The cable has 45 pairs with connectors with strain relief .
outer shield . The cable is terminated at each for use with: 7020
end with 96-pin female DIN connectors with
strain relief .
7011-MTC-1 1m (3 .3 ft)
7011-MTC-2 2m (6 .6 ft)
for use with: 7011-C, 7012-C, 7013-C, 7015-C,
ACCESSORIES



7018-C, 7022
Model 6517B-ILC-3 Interlock Cable: Designed
to connect the interlock of the 6517B with the
8009 test fixture . Configuring the 6517B with the
8009 test fixture results in all the electrode con-
stants already being programmed into the unit .
for use with: 6517b Electrometer, 8009


1.888.KEITHLEY (U.S. only)
www.keithley.com
A Greater Measure of Confidence
Cables




2 slot Triax



Model 7024-* 2-slot Triax Cable: Low noise
triax cable (SC-22) with 2-slot male triax connec-
tors on each end .
7024-3 0 .9m (3 ft) Model 7036-MTC-2: 2m (6 .6 ft) mass terminated
7024-10 3m (10 ft) cable assembly for connection to 7036 . The
Cables




Cables
cable has 45 pairs with outer shield . The cable is Model 7078-MTC-5: 1 .5m (5 ft) mass terminated
for use with instruments with 2-slot triax
terminated at each end with 96-pin female DIN cable for connection to column inputs (7071 and
connectors
connectors with strain relief . 7071-4) . Also used for matrix expansion (7071,
7071-4, or 7074) . The cable has 12 sets of shielded
for use with: 7036
twisted pair wires for isolation of critical circuits
and noise rejection in the system . The cable is ter-
minated at each end in a 38-pin connector block
with strain relief . Model 7078-MTC-20 can be
used as is or cut in half to make two 10 ft cables .
for use with: 7071, 7071-4, 7074-D



2 slot Triax


Model 7025-10 2-slot Triax Cable: 3m (10 ft)
low noise triax input cable (SC-22) terminated Model 7051-*: General purpose BNC to BNC
on one end with 2-slot male triax connector . cable (G-58C) .
for use with instruments with 2-slot triax 7051-2 0 .6m (2 ft)
connectors 7051-5 1 .5m (5 ft)
7051-10 3m (10 ft)
for use with: 2015, 2016, 3390, 7711, some
3 slot Triax
instrument external trigger I/o lines
Model 7078-TRX-* 3-slot Triax Cables: Low
noise triax cables terminated at both ends in
3-slot male triax connectors .
7078-TRX-1 0 .3m (1 ft)
7078-TRX-3 0 .9m (3 ft)
7078-TRX-5 1 .5m (5 ft)
7078-TRX-10 3 .0m (10 ft)
7078-TRX-12 3 .5m (12 ft)
7078-TRX-20 6 .0m (20 ft)
for use with: 2635b, 2636b, 6220, 6221, 6482,
ACCESSORIES




6487, 6514, 6517a, 6517b, 7072, 7174a
Model 7035-MTC-2: 2m (6 .6 ft) mass terminated Model 7078-DIN: This 1 .8m (6 ft) cable acces-
cable assembly for connection to 7035 . The sory connects between Model 707A mainframes
cable has 45 pairs with outer shield . The cable is when operated as one unit in Master/Slave
terminated at each end with 96-pin female DIN mode . One cable is required for each mainframe .
connectors with strain relief . for use with: 707a
for use with: 7035



1.888.KEITHLEY (U.S. only)
www.keithley.com
A Greater Measure of Confidence
Cables




3 slot Triax
Model 7173-50-CSEP: The 7173-50-CSEP cable
Model 7078-TRX-6IN 3-slot Triax Cable: 0 .15m set provides the capability to expand a switching
(6 inch), 3-slot, low-noise, guarded triax cable that configuration to include more than one 7173-50 .
minimizes leakage current and input capacitance Each set contains four 0 .6m (25 in) cables . One
Cables




Cables
when used with the Model 6430 Remote PreAmp cable is required to expand each row or column
(lower noise than 1 foot or longer versions) . Model 7152-TRX-10: Set of five 3m (10 ft) low connection between adjacent cards . For exam-
noise triax cables terminated at one end in a ple, using two 7173-50 cards to create a 4