Text preview for : HP-Catalog-1958-05-Short.pdf part of HP HP-Catalog-1958-05-Short HP Publikacje HP-Catalog-1958-05-Short.pdf
Back to : HP-Catalog-1958-05-Short. | Home
HP Archive
This vintage Hewlett Packard document was preserved and distributed by
www. hparchive.com
Please visit us on the web !
On-line curartor: Glenn Robb
HEWLETT- PACKARD COMPANY PALO A L T O , C A L I F O R N I A
-hp- offers complete coverage in
-hp- 150A/AR High Frequency Oscilloscopes-DC to 1 0 MC
Models 150A and 150AR are deliberately designed as the Specifications
most broadly useful, most convenient high quality 10 MC Sweep Range: 0.02 psec/cm to 1 5 sec/cm.
oscilloscopes ever built. Unique features such as the universal Calibration: 24 sweeps: 1 - 2 - 5 - 1 0 sequence, 0.1 psec/cm to 5 sec/cm.
automatic optimum - trace trigger, direct - reading calibrated 3% accuracy.
sweeps, simplified color-coded controls and quick filter or T r i g g e r i n g : Internal, line voltage or external 0.5 v or more. Pos. or
cathode ray tube interchange-all combine to save hours of neg. slope, + 30 to -30 v trigger range.
Preset T r i g g e r : Optimum setting for automatic stable triggering.
engineering time.
H o r i z o n t a l A m p l i f i e r : Sweep magnification 5, 10, 50, 100 times. Ver-
nier position control selects any 10 cm part of sweep. External
Plug-in amplifiers increase versatility input pass band dc to over 500 KC. Sensitivity 200 mv/cm to
1 5 v/cm.
A variety of plug-in units (see below) provide the versatility V e r t i c a l A m p l i f i e r : Pass band dc to 10 MC. Optimum transient re-
of dual trace or differential input, or high amplification elimi- sponse and rise time less than 0.035 psec. Signal delay of 0.25
nating pre-amplifiers on input from most transducers. Other psec permits leading edge of triggering signal to be viewed.
important features include brilliant, high resolution trace with- A m p l i t u d e C a l i b r a t i o n : 18 calib. voltages, 1-2-5-10 sequence, 0.2 mv
out halo or bloom, etched circuits with unitized construction, to 100 v peak-to-peak. Accuracy 3%. Approx. 1 KC square wave,
rise and decay approx. 1.0 psec. i'
highest quality components and ultra-conservatively rated Prices: -hp- 150A High Frequency Oscilloscope, $1,100.00.
circuitry. -hp- 150AR Rack Mount Oscilloscope, $1,200. A
New amplifiers and accessories
-hp- 152B D u a l T r a c e D i f f e r e n t i a l A m p l i f i e r . -hp- 1 5 3 A V e r y H i g h G a i n A m p l i f i e r . New For either
-hp- 1 5 1 A H i g h G a i n A m p l i f i e r .
New plug-in amplifier providing differential plug-in permitting -hp- 150A to be used for 150A or 150AR, high gain unit with 5.0 mv/
input and dual traces electronically switched many direct measurements from transducer cm sensitivity, frequency response dc to IO
between A and B channels at either 100 KC without preamplification. Pass band dc to 500 MC. 1 2 calibrated ranges on 1 - 2 - 5 - 10
or on alternate sweeps. Sensitivity range 0.05 KC, sensitivity 1 mv/cm to 1 2 5 v/cm, bal- sequence. 1 megohm input impedance with
v/cm to 50 v/cm, input attenuator with 9 anced input on the 6 most sensitive ranges. 27 ppf shunt. Pass band rise time 0.035 psec.
calibrated ranges in 1- 2 - 5 - 10 sequence and 1 5 calibrated ranges in 1- 2 - 5 - 10 sequence, Has 2 BNC terminals. $200.00.
vernier. $2 50.00. 1 mv/cm to 50 v/cm; plus vernier. $125.00.
Data subject to change without notice. Prices f. 0. 6 . factory.
2
quality oscilloscopes DC to 1 0 MC !
-hp- 130B /BR - DC to 300 K C -hp- 120A/ AR-DC to 200 K C
Termed the finest low frequency oscilloscope ever offered, -hp- Ideal for industrial or production line work as well as daily
130B/BR combine big `scope performance and positive de- lab jobs, Models 120A/AR are outstanding in both value and
. "big `scope" performance features. This all-new instrument
pendability with 1 mv sensitivity and the convenience of direct
reading, "universal" automatic trigger, no preamplification covers DC to 200 KC, has the -hp- universal trigger circuit
which optimizes signals automatically; also offers automatic
from most transducers and simple controls.
synchronization on any internal or external voltage including
line power.
Similar X and Y amplifiers
Models 130B/BR have similar horizontal and vertical ampli- Sweeps 1 psec/cm to 0.5 sec/cm
fiers with sensitivity 1 mv/cm to 1 2 5 v/cm. Input circuits are Features include 1 5 calibrated sweeps in 1-2-5 sequence, sweep
balanced on the 6 most sensitive ranges; single ended input dc speeds range 1 psec/cm to 0.5 sec/cm, "times-5" sweep expan-
or ac coupled. 2 1 sweep times may be directly set, instrument sion on all ranges, high sensitivity calibrated vertical amplifiers.
All power supplies are regulated for steady, drift-free traces.
sweeps 1 pec/cm to 1 2 . 5 sec/cm, triggering is internally, by
Automatic trigger and base line can be cut out for bright, clear
line power, or externally by 0.5 v or greater. Includes x 5 mag- photography trace. Extra compact Model 120AR is only 7"
nifier for all internal sweeps increasing fastest sweep time to high. Utmost dependability, rugged construction. -hp- 120A
0.2 pec/cm. -hp- 130B (cabinet) or 130BR (rack) $650.00. (cabinet) or 120AR (rack) $435.00.
increase convenience of your 150A/AR
.. , -hp- A C - I ISA O s c i l l o s c o p e T e s t m o b i l e . Most convenient mobile os-
cillo>cope mounting. For 150A oscillosiopes but usable with other
instrumtents. Rolls easily on large 4" rubber-tired wheels. Extra-sturdy
Construction of " k " tube stock, gleaming chrome throughout, Top
shelf tilts 30' in four 71 i increments for better viewing. 580.00.
`
- h p - A C - 1 1 6 A T e s t m o b i l e S t o r a g e U n i t . Extra-convenient storage for
-hp- A C - 2 I C 50: V o l t a g e D i v i d e r Probe. -lip- 151A 1 5 2 A / B , 153A oscilloscope plug-ins. Holds up t o three
A 50:l divider with high 10 megohm extra plug-ins gaurd against dust. mechanical damage. Fits -hp- AC-
input impedance and low 2.5 wf input 115A Testrmobile (see photo): no installation needed 522.50.
capacitance. Convenient "pen" size for -hp- AC-117A T e s t m o b i l e A c c e s s o r y D r a w e r . Fits in -hp- AC-116A
maximum handling ease. Probe has dur- Storage U n i t convienent drawer storage for tools, componenrs,
able, attractive nylon barrel, alligator clip solder etc. Photo shows AC-117A installed in top rack of AC-116A
contactor. $25.00. Storage Unit 510.00.
3
-hp- Oscillators 0.008 to 10,000,000 cps
Hewlett-Packard now offers 12 high quality, Instrument P r i m a r y Uses Frequency Range output Price
fast and accurate oscillators, each an excep- -.
-hp- 200AB A u d i o tests 20 cps t o 40 KC I watt/24.5 v ;130.00
tional value and each engineered to do a spe-
cific job best. Each incorporates the famous -hp- 200CD
Subsonic through supersonic
5 cps t o 600 KC
I60 mw or IO v/500 ohms; 160.00
audio and ultrasonic tests 20 v open circuit
RC resistance capacity circuit pioneered by
Interpolation, frequency
-hp-. This circuit makes possible instruments -hp- 200J
measurements
6 cps t o 6 KC 160 mw/lO v 275.00
that are highly stable, wide range, compact 160 mw or IO vl6OO ohms;
-hp- 200T Telemetry, carrier current tests 250 cps t o IO0 KC 350.00
and portable; instruments that are extremely 20 v open circuit
simple to operate and require no tedious -hp- 201C H i g h quality audio t e s t s 20 cps t o 20 KC 3 w or 42:5 v/6OO ohms 225.00
re-setting or adjustment during operation.
-hp- 202A LOW frequency measurements 0.008 t o 1200 cps '8 m w or ohms p-p/4000
0 v
' 465.00A
-hp- 200 Series Audio Oscillators
For audio and ultrasonic
-hp- 202C Servo equipment tests'
measurements
I cps t o 100 KC
I 160 mw or IO v/600 ohms 300.00
-hp- 205AG
H i g h power audio tests, 2o cps to 2o KC 5 watts 475.00A
measurements, -hp- offers gain measurements
popular Models 200AB
and 2 0 0 C D . Both have
highest stability and accu-
-hD- 206A
H i g h quality, high accuracy
audio tests I 2o cps to 2o KC I + 15dbm 1.0
650A
rate tuning circuits. Low -hp- 207A 275.00
impedance operating lev- ___
els plus superior insula- -hp- 233A 475.00
tion guarantee long years
of trouble-free dependa- -hp- 650A 15 mw/3 v 490.00A
bility. Operation is sim-
ple; just three controls; no A Rack mounted instruments available at $15.00 less.
zero setting necessary. -hp-
200AB, 20 cps to 40 KC, $130.00. -hp- 200CD 5
cps to 600 KC, $160.00.
-hp- 2 0 7 A Sweep Oscillator
This new audio oscillator
provides continuous sin-
gle-sweep frequency cov-
erage from 20 cps to 20
-
KC.No band switching is -hp- 202A, $465.00A.
needed; dial accuracy is
470, and the instrument
also provides a flexible 10 -hp- 6 5 0 A Test Oscillator
v/600 ohm output usable Covering 10 cps to 10 MC, -hp- 650A is a highly
balanced or with one side stable, wide band instrument for audio, super-
grounded. Frequency re- sonic, video and rf measurements. Output is flat
sponse is k 1 . 0 db full within 1 db full range; voltage range is 0.00003
range, distortion and hum are less than 1%. to 3 v. In addition to 600 ohm impedance, volt-
-hp- 207A may be swept by hand, motor driven age divider provided a 6 ohm impedance. Dis-
tuned remotely or coupled t o a recorder -hp- 207A, tortion less than 1% to 100 KC; stability
$275.00. * 2% to 100 KC. $490.00A.
-hp- Distortion, Wave Form Analyzers-20 cps to 20 KC
-hp- 330B Distortion Analyzer
Instrument P r i m a r y Uses
Frequency
Range
Characteristics
I Price
-hp- 300A Wave form analyzer 30 cps t o 16 KC selectivity; measuring
Variable I m v t o 500 v
range $775.00
-hp- 3308 Measures total audio
distortion 20 cps t o 20 KC Includes input amplifier, VTVM 4l0.00A
-hp-
For FM broadcast 2o cps to KC Special VU meter t o meet M ~ , ~ ~ A
measurements F.C.C. requirements
0.1% are readable
accurately. Frequency calibration accurate within For AM, FM broadcast AM detector and VU meter t o
* 2% full range. Includes a 20 db amplifier, oscil-
-hp- 330D measurements 2o cps to 2o KC meet F.C.C. requirements 455,OOA
loscope terminals and precision 10 cps to 100 KC
vacuum tube voltmeter usable separately. $410.00A. A Rack mounted instruments available a t fl5.00 less.
4
NEW! -hp- 2 1 8 A Digital Delay Generator
Independently adjustable time
intervals or pulse delays
t 0 . 1 psec time interval accuracy
Crystal oscillator time base
Regulated power supplies
Model 218A Digital Delay Generator is a totally new instru-
ment applicable to many types of timing measurements in-
cluding calibrating the range determining circuits of radar
receivers, etc. The generator is built to rigid standards and is
suitable for military use. It provides two precision time inter-
vals or pulse delays, either of which are independently adjust-
able from 1 to 10,000 microseconds in 1 microsecond steps.
These time intervals are accurate to within 0.1 microsecond
t o . o o l % of the selected value, and may be initiated from an
internal multi-vibrator, 10 cps to 10 KC, or from an external
rate generator, 0 cps to 10 KC. Total jitter does not exceed
-hp- 219A Dual Trigger Unit 0.02 microseconds in either case. The instrument also provides
This plug-in drawer for -hp- 218A supplies trigger pulses of a 50 volt synchronizing output pulse at the beginning or end
positive polarity, 50 volts, 0.1 psec rise time from a 50 ohm of a time interval, and a 1 microsecond timing comb output
source. Pulse A occurs at To or T, as selected by a switch; at the front panel.
Pulse B is triggered at T,. -hp- 219A, $lOo.OO.
No count ambiguity
-hp- 2196 Dual Pulse Unit
A unique feature of the new -hp- 218A is its time base, a
This plug-in drawer for -hp- 218A produces two high-power pulsed crystal controlled oscillator. The oscillator starts at To
pulses which are continuously adjustable in width, 0.2 to 5 and stops at the last output pulse. This eliminates the "plus-
psec and in amplitude from 0 to 50 volts, positive or negative or-minus-1-count" ambiguity of many counter circuits in such
polarity. The leading edge of these pulses can be set to occur application.
at the beginning or end of the selected time interval. Both
pulses are brought out to separate front panel jacks but may be Model 218A is a completely self-contained instrument, re-
switched to a common jack with no change in level or output quiring only one or more -hp- 219 series plug-ins to perform
impedance. -hp- 219B, $450.00. a broad variety of time and delay generation measurements.
Simplicity and flexibility are increased by the large variety of
-hp- 219C Digital Pulse Duration Unit input and output connections brought to the front panel. The
instrument is particularly compact and well-designed; etched
This plug-in drawer for -hp- 218A produces a high power circuits and the use of plug-ins materially increase circuit ac-
output pulse whose delay and duration are digitally controlled. cessibility.
The pulse is available in both polarities simultaneously, and is
continually adjustable in amplitude up to 20 volts from a 90 The instrument's power supplies are fully regulated to avoid
ohm source. It may also be obtained from a directly coupled effects of line voltage variations. It is available as -hp- 218A,
500 ohm source with an amplitude of 100 volts. -hp- 219C, cabinet mount, or 218AR, rack mount. -hp- 218A/AR,
$350.00. $2,000.00.
-hp- Square Wave and Pulse Generators
-hp- 212A Pulse Generator - h p - 211A Square Wave Generator
Provides continuously variable, high Versatile, wide range instrument for testing
power "fast pulses" of superior wave oscilloscopes, networks, video and audio am-
form. Combines broad general useful- plifier performance, modulating signal gen-
ness with 0.02 psec rise and decay erators and measuring time constants. Offers
time to meet requirements of radar, simple control of electronic switches; is also
T V and nuclear work. Pulse length convenient for indicating phase shift, fre-
variable 0.07 to 10 ~ e c minimum
: quency reseowe, trar:isient effects. Two separate outputs ( a ) 7 volt
overshoot; 50 watt peak power ( 5 0 v to 50 ohms load). Low imped- 7 5 ohm circuit for T V work; ( b ) 5 5 volt 600 ohm output for high
ance means accurate pulses can be delivered at a distance from the level work. Both have full amplitude variation. Instrument operates
instrument. Repetition rate variable 50 to 5,000 pps; controlled inter- free-running or externally synchronized with positive going pulse or
nally or externally. Synchronizing pulse available in advance of, or sine wave of S volts minimum amplitude. $265.00.
following output pulse. $565.00 (cabinet), $S50.00 (rack mount).
5
-hp- Vacuum Tube Voltmeters 1 0 to 700,000,000 cps
NEW! -hp- 400L Logarithmic Voltmeter NEW! -hp- 4 2 5 A Microvolt-Ammeter
New -hp- 400L, 10 cps to 4 MC, features a 5" New, high sensitivity, high stability microvolt
true log voltage scale plus a 1 2 db linear decibel meter reading full scale voltages of 10 pv to
scale. The log voltage scale plus long scale length 1 v in 11 ranges. Also reads currents of 10 ppa
provides a voltmeter of maximum readability and to 3 ma in 18 step, 1 - 3 - 1 0 sequence. Accuracy
an accuracy which is a constant percentage of + 3% on all ranges. Drift less than 2 pv referred
to input terminals Input impedance 1 megohm
jhe reading. Accuracy is f 25% of reading or i- 3% on all ranges Instrument can also be
i 1% of full scale, whichever is more accurate, used as a 100 db amplifier providing up to 1 v
to 500 KC; *
55% full frequency range Voltage output from signals as small as 10 Pv. Amplifier
range 0.3 mv to 300 v in 1 2 steps. ac rejection is at least db at 0 . 2 ; ~ and 60 db at 60 cps. InAaddi-
~
tion to engineering uses ideal for physics, chemistry applications
Generous overlap is insured by a 1o db range switch plus a 12 db
including grid or photomultiplier tube currents, ionization levels,
scale length. High stability, l o megohm input impedance. Meter is thermocouple potentials and voltaic currents. Also measures v in
mirror backed for maximum accuracy. Also may be used as a stable living cells, nerves, seeds, plants. Includes probe. $500.00.
amplifier. $325.00.
-hp- 4 0 0 D Vacuum Tube Voltmeter
Best -hp- voltmeter ever built! Frequency Voltage Input
Instrument Price
Covers all frequencies 10 cps to Primary Uses Range Range Impedance
4 MC. Extremely sensitive, wide
- h p - 400AB General purpose ac c p s to KC 0.003 t o 300 v
range, accurate within 270 to 1 measurements ranges
MC, measures 0.1 mv to 300 v.
Direct reading in dbm. 10 meg-
o h m i n p u t impedance insures
negligible loading on circuits un-
-hp- 400D
I W i d e range ac
measurements
H i g h sensitivity
H i g h accuracy wide
I
0.001 t o 300 v IO megohms
der test. New amplifier circuit with mid-range feed- -hp- 400H range ac locps t o 4 MC 12 ranges 15 p p f shunt 325'00
measurements
back assures utmost stability, freedom from change
due to external conditions. $225.00. -hp- 400L
Log voltages, linear cps to MC mv t o 300 v IO megohms
d b measurements 12 ranges 15 p p f shunt 325.00
-hp- 410B Vacuum Tube
Voltmeter
-hp- 410B
I Audio, r f , VHF
measurements; dc
voltages: resistances
Read p v , @pa; 100 d b
dc; ac-20
cps to '