Text preview for : 24649A(PIO-32CEInfo).pdf part of Keithley 24649A(PIO-32CEInfo) Keithley Misc 24649A(PIO-32CEInfo).pdf



Back to : 24649A(PIO-32CEInfo).pdf | Home

CE Mark Information
for the PIO-32 Series

Note: Products that contain the CE Mark are certified to meet European
EMC directive 89/336 EEC. If this directive is not of importance to your
application, please disregard the information in this document.


Keithley MetraByte certifies that this product has been tested and found
to be in compliance with the EMC directive and relevant harmonized
standards.

This document describes the limitation of certification, the declaration of
conformity, and the cabling instructions required for the CE Mark
configuration.


Limitation of Certification

This certification applies only to the operation of the product (with
specified cables and accessories) in the stated configuration and under the
stated operational and environmental specifications. Any modification,
misuse, or improper or inadequate maintenance of the product by the user
voids this certification.

Any deviation from the specific configuration may cause emissions or
susceptibility not within the allowed limits required by the stated
directive. It is the user's responsibility to demonstrate and maintain
compliance with the directive and standards.

Please read the next section, "Declaration of Conformity," for the specific
testing configuration for this product. Consult the Keithley Instruments
GMBH office (European importer) or Technical Support in Taunton, MA,
USA, for further information regarding the exact configuration details and
testing.


Part Number: 24649; Revision A 1
Declaration of Conformity

Application of Council Directive(s) 89/336/EEC
Standard(s) to which Conformity is EN50081-1, EN50082-1
Declared
Manufacturer's Name Keithley MetraByte
Importer's Name Keithley Instruments GMBH
Importer's Address Landsberger Str.65 D-82110 Germering, Munich
Type of Equipment Data Acquisition Plug-in Boards
Model Numbers PIO-32IN, PIO-32OUT, PIO-32I/O with STP-37/FC,
C-3200, and JACKET shield
Year of Manufacture 1995


I, the undersigned, hereby declare that the equipment specified above conforms
to the above Directive(s) and Standard(s).
Place: Taunton, MA USA
___________________________________
(Signature)

Date: 01 January 1996 Mark Urban
(Name)

Quality Assurance Manager
(Position)




2 December 1995
Cabling Instructions for the CE Mark Configuration

Use the C-3200 cable to connect one or more STP-37/FC accessories to a
PIO-32 Series board, as shown in Figure 1. Refer to the board's user's
guide for more information.

STP-37/FC
Screw Terminal Panels




PIO-32 Series board




C-3200 cables




Figure 1. Attaching a PIO-32 Series Board to an STP-37/FC

For CE Mark compliance, you must shield the C-3200 cables. The
procedure for shielding the cables is as follows:
1. With cabling installed and clamped, wrap all cables together with a
piece of tape to mark a shield boundary at a point one-half inch or
more away from the inside surface of the mounting plate, as shown in
Figure 2.


Mounting Plate


PIO-32 Series

Tape Marker inch
from Mounting Plate


Figure 2. Cabling Taped to Show Shield Boundary

2. Remove the two clamp-adjusting screws and the clamp from the
board's mounting plate.


Part Number: 24649; Revision A 3
3. Unplug the cable connectors from board, and pull the taped cabling
back through the mounting plate until the tape marker is beyond the
clamping area.
4. Beginning at the tape marker, cover the cabling with a single piece of
jacket to the desired length, as shown in Figure 3.


Mounting Plate


PIO-32 Series




Figure 3. Cabling Wrapped with Jacket to Tape Boundary

5. Remove tape from cabling, and use scissors to cut -inch flaps in the
jacket on both sides of cable, as shown in Figure 4.


Fold Line


PIO-32 Series



inch


Figure 4. Jacket Trimmed with Scissors to Make -Inch Flaps

6. Fold the flaps back on both sides of cabling to expose the shield
surface, as shown in Figure 5.

Mounting Plate


PIO-32 Series
Shield
Surface



Figure 5. Jacket with Flaps Folded Back to Expose Shield Surface
7. Slide cabling back through mounting plate and plug the cable
connectors back into the board, placing shield surface directly in line
with mounting-plate clamp, as shown in Figure 6.


Mounting Plate


PIO-32 Series
Shield
Surface




Figure 6. Cabling Reconnected, Placing Shield Surface in Line with
Clamp

8. Re-install the clamp and clamp-adjusting screws so that the clamp
holds the cabling firmly in place while bearing firmly on the shield
surface of the jacket flap, as shown in Figure 7.




Trimmed and
Folded-back
Jacket Flap



Jacket
Cable over
Cable




Clamp




Figure 7. Detail of Clamped Cable Showing Installed Jacket


Part Number: 24649; Revision A 5