Text preview for : Samsung_LN-S3292D_LN-S4092D_LN-S4692D_Precaution_[SM].pdf part of Samsung Samsung LN-S3292D LN-S4092D LN-S4692D Precaution [SM] Samsung Monitor Samsung_LN-S3292D_LN-S4092D_LN-S4692D_Precaution_[SM].pdf



Back to : Samsung_LN-S3292D_LN-S409 | Home

1 Precautions



1 Precautions
Follow these safety, servicing and ESD precautions to prevent damage and to protect against potential hazards such as electrical shock.

1-1 Safety Precautions

1-1-1 Warnings
1. For continued safety, do not attempt to modify the circuit
board.
2. Disconnect the AC power and DC power jack before
servicing.
1-1-2 Servicing the LCD Monitor
1. When servicing the LCD Monitor, Disconnect the AC
line cord from the AC outlet.
2. It is essential that service technicians have an accurate
voltage meter available at all times. Check the
calibration of this meter periodically.

1-1-3 Fire and Shock Hazard
Before returning the monitor to the user, perform the Figure 1-1. Leakage Current Test Circuit
following safety checks:
1. Inspect each lead dress to make certain that the leads are 4. With the unit completely reassembled, plug the AC line
not pinched or that hardware is not lodged between the cord directly into a 120V AC outlet. With the unit's AC
chassis and other metal parts in the monitor. switch first in the ON position and then OFF, measure
2. Inspect all protective devices such as nonmetallic control the current between a known earth ground (metal water
knobs, insulating materials, cabinet backs, adjustment pipe, conduit, etc.) and all exposed metal parts,
and compartment covers or shields, isolation resistor- including: metal cabinets, screwheads and control shafts.
capacitor networks, mechanical insulators, etc. The current measured should not exceed 0.5 milliamp.
3. Leakage Current Hot Check (Figure 1-1): Reverse the power-plug prongs in the AC outlet and
repeat the test.
WARNING : Do not use an isolation
transformer during this test.
Use a leakage current tester or a metering system that 1-1-4 Product Safety Notices
complies with American National Standards Institute Some electrical and mechanical parts have special safety-
(ANSI C101.1, Leakage Current for Appliances), and related characteristics which are often not evident from visual
Underwriters Laboratories (UL Publication UL1410, inspection. The protection they give may not be obtained by
59.7). replacing them with components rated for higher voltage,
wattage, etc. Parts that have special safety characteristics are
identified by on schematics and parts lists. A substitute
replacement that does not have the same safety characteristics
as the recommended replacement part might create shock, fire
and/or other hazards. Product safety is under review
continuously and new instructions are issued whenever
appropriate.




1-1
1 Precautions

1-2 Servicing Precautions
WARNING: An electrolytic capacitor installed with the wrong polarity might explode.
Caution: Before servicing units covered by this service manual, read and follow the Safety Precautions section
of this manual.
Note: If unforeseen circumstances create conflict between the following servicing precautions and any of the safety
precautions, always follow the safety precautions.


1-2-1 General Servicing
Precautions 4. Check the insulation between the blades of the AC plug
1. Always unplug the unit's AC power cord from the AC and accessible conductive parts (examples: metal panels,
power source and disconnect the DC Power Jack before input terminals and earphone jacks).
attempting to: 5. Insulation Checking Procedure: Disconnect the power
(a) remove or reinstall any component or assembly, (b) cord from the AC source and turn the power switch ON.
disconnect PCB plugs or connectors, (c) connect a test Connect an insulation resistance meter (500 V) to the
component in parallel with an electrolytic capacitor. blades of the AC plug.
2. Some components are raised above the printed circuit The insulation resistance between each blade of the AC
board for safety. An insulation tube or tape is sometimes plug and accessible conductive parts (see above) should
used. The internal wiring is sometimes clamped to be greater than 1 megohm.
prevent contact with thermally hot components. Reinstall 6. Always connect a test instrument's ground lead to the
all such elements to their original position. instrument chassis ground before connecting the positive
3. After servicing, always check that the screws, lead; always remove the instrument's ground lead last.
components and wiring have been correctly reinstalled.
Make sure that the area around the serviced part has not
been damaged.


1-3 Electrostatically Sensitive Devices (ESD) Precautions
Some semiconductor (solid state) devices can be easily damaged by static electricity. Such components are commonly called
Electrostatically Sensitive Devices (ESD). Examples of typical ESD are integrated circuits and some field-effect transistors. The
following techniques will reduce the incidence of component damage caused by static electricity.


1. Immediately before handling any semiconductor 6. Do not remove a replacement ESD from its protective
components or assemblies, drain the electrostatic charge package until you are ready to install it. Most
from your body by touching a known earth ground. replacement ESDs are packaged with leads that are
Alternatively, wear a discharging wrist-strap device. To electrically shorted together by conductive foam,
avoid a shock hazard, be sure to remove the wrist strap aluminum foil or other conductive materials.
before applying power to the monitor. 7. Immediately before removing the protective material
2. After removing an ESD-equipped assembly, place it on a from the leads of a replacement ESD, touch the
conductive surface such as aluminum foil to prevent protective material to the chassis or circuit assembly into
accumulation of an electrostatic charge. which the device will be installed.
3. Do not use freon-propelled chemicals. These can Caution: Be sure no power is applied to the
generate electrical charges sufficient to damage ESDs. chassis or circuit and observe all
4. Use only a grounded-tip soldering iron to solder or other safety precautions.
desolder ESDs.
5. Use only an anti-static solder removal device. Some 8. Minimize body motions when handling unpackaged
solder removal devices not classified as "anti-static" can replacement ESDs. Motions such as brushing clothes
generate electrical charges sufficient to damage ESDs. together, or lifting your foot from a carpeted floor can
generate enough static electricity to damage an ESD.




1-2
1 Precautions

1-4 Installation Precautions
1. For safety reasons, more than two people are 6. Keep the antenna far away from any high-voltage
required for carrying the product. cables and install it firmly. Contact with the highvoltage
cable or the antenna falling over may
2. Keep the power cord away from any heat emitting cause fire or electric shock.
devices, as a melted covering may cause fire or
electric shock. 7. When installing the product, leave enough space
(10cm) between the product and the wall for
3. Do not place the product in areas with poor ventilation purposes.
ventilation such as a bookshelf or closet. The A rise in temperature within the product may cause fire.
increased internal temperature may cause fire.


4. Bend the external antenna cable when connecting
it to the product. This is a measure to protect it
from being exposed to moisture. Otherwise, it
may cause a fire or electric shock.


5. Make sure to turn the power off and unplug the
power cord from the outlet before repositioning
the product. Also check the antenna cable or the
external connectors if they are fully unplugged.
Damage to the cord may cause fire or electric
shock.




1-3
1 Precautions

Memo




1-4