3 Alignments and Adjustments



3 Alignments and Adjustments
3-1 General Alignment Instuction
1. Usually, a color LCD-TV needs only slight touch-up adjustment upon installation.
Check the basic characteristics such as height, horizontal and vertical sync.
2. Use the specified test equipment or its equivalent.
3. Correct impedance matching is essential.
4. Avoid overload. Excessive signal from a sweep generator might overload the front-end
of the TV. When inserting signal markers, do not allow the marker generator to distort test result.
5. Connect the TV only to an AC power source with voltage and frequency as specified on
the backcover nameplate.
6. Do not attempt to connect or disconnect any wire while the TV is turned on. Make sure
that the power cord is disconnected before replacing any parts.
7. To protect aganist shock hazard, use an isolation transform.




3-1
3 Alignments and Adjustments

3-2 Factory Mode Adjustments
3-2-1 Entering Factory Mode
To enter 'Service Mode' Press the remote -control keys in this sequence :
- If you do not have Factory remote - control

Power OFF INFO MENU MUTE Power On

3-2-2 Factory Mode Tree
- If you have Factory remote - control
[INFO] -> [FACTORY]
1. Calibration 1. Calibration : W/B Calibration
2. Option Byte
3. W/B AV Calibration
4. VCTi DTV Calibration
5. YC Delay PC Calibration
6. FLI5961
7. Adjust
8. Test Pattern 2. Option byte : Setting option
9. Password
10. Check Sum Panel option : 32"/40"/23"/26"/27"
11. Spread Spectrum Gamma : off/on
12. HDCP Analog Dimming : AUO/CMO/AMLCD/Panal2
13. Reset Auto Power : on/off
T-TRNPEU-0000 month day year time Video Mute :5
P-TRNPEU-0000 Language : English
Panel On Time(Hour) 0000 Hotel Mode : off/on
LNA Plus : off/on
V-chip : off
Auto FM : off/on
High Deviation : off/on
TTX List : Flop/List
TTX Top : off/on
TTX Group : Auto/West Europe/East Europe/
Russian/Greek Turkey/Arabic/
Farsian/Arab.Habrew
DVI : on/off
HDCP Key : ok


3. W/B : Adjustment White Balance

Sub Bright : 128
R off set : 128
G off set : 128
B off set : 128
Sub contrast : 128
R gain : 128
G gain : 128
B gain : 128


4. VCTi : VCTi IC Correct register

VCTi Page 1
VCTi Page 2



3-2
3 Alignments and Adjustments




1. Calibration 5. YC Delay
2. Option Byte
3. W/B RF PAL-B/G : 5
4. VCTi RF PAL-D/K : 6
5. YC Delay RF PAL-I : 5
6. FLI5961 RF PAL-L/L' : 5
7. Adjust RF SECAM-B/G : 2
8. Test Pattern RF SECAM-D/K : 0
9. Chip Debugger RF SECAM-I : 2
10. Check Sum RF SECAM-L/L' : 0
11. Spread Spectrum RF NTSC 3.58 : 5
12. HDCP RF NTSC 4.43 : 5
13. Reset AV PAL : 5
T-TRNPEU-0000 month day year time AV SECAM : 2
P-TRNPEU-0000 AV NTSC 3.58 : 5
Panel On Time(Hour) 0000 AV NTSC 4.43 : 5
AV PAL 60 : 5


6. FLI5961 : Scaler IC Correct register

Component Calibration: Result DTV Calibration
PC Calibration : Result PC Calibration
ACC/ACM
TNR
Picture Enhance


7. Adjust

User Control lnitial
LNA PLUS
Hotel Option


8. Test Pattern : VCTi IC'S own test patterns.
(Total 7 patterns)



9. Password : Use IC Register Correction.


10. Check Sum : 0000


11. Spread Spectrum

Spread Spectrum : on/off
Spread Spectrum Range : 2
Step : 63


12. HDCP : 0000


13. Reset




3-3
3 Alignments and Adjustments

3-3 White Balance - Calibration

3-3-1 White Balance -Calibration

1. Calibration DTV Calibration
PC Calibration
(Calibration Condition refer to next page)




3-3-2 White Balance - Adjustment

(low light) (hight light)
3. W/B Sub Bright Sub Contrast
R offset R gain
G offset G gain
B offset B gain
(W/B adjustment Condition refer next page)




3-3-3 Conditions for Measurement
1. On the basis of toshiba ABL pattern : High Light level (57 IRE)
- INPUT SIGNAL GENERATOR : MSPG-925LTH
* Mode NO 1 : 744X484@60 Hz
NO 6 : 1280X720@60 Hz (Component 720P)
NO 21 : 1024X768@60 Hz
* Pattern NO 15 : Color bar
NO 16 : Toshiba ABL Pattern
NO 17 : 16 gray
2. Optical measuring device : CA210 (FL)
Please use the MSPG-925 LTH generator for model LNR2355W,LNR2755W,LNR3255W.




3-4
3 Alignments and Adjustments

3-3-4 Method of Adjustment
1. Adjust the basic level of Component and PC input signals.
a) Set the input to the mode in which the adjustment will be made (Component PC ).
* Input signal - Component Mode : Model #6 (1280*720 Mode), Pattern #15 (picture 4-1)
- PC Mode : Model #21 (1024*768 Mode), Pattern #17 (Picture 4-2)
b) Enter factory Calibration (DTV, PC Mode Only).
* DTV Calibration Source change for PC PC Calibration


Picture 4-1 Color bar Picture 4-2 16gray




2. Adjust the white balance of AV, Component and DVI Modes.
a) Set the input to the mode in which the adjustment will be made (AV Component DVI).
* Input signal - VIDEO Mode : Model #1 (744*484 Mode), Pattern #16
- Component, DVI Mode : Model #6 (1280*720 Mode), Pattern #16
b) Enter factory W/B.

c) Adjust the low light.
- Adjust sub - Brightness to set the 'Y' value.
- Adjust red offset ('x') and blue offset ('y') to the color coordinates. ( x : 263, y : 267, Y : 1.3 ft)
* Do not adjust green offset data.

Picture 4-3 Toshiba ABL Pattern




Low light
Measurement point




3-5
3 Alignments and Adjustments

d) Adjust the high light. (Refer to table 1, 2 in adjustment position by mode)
- Adjust red gain ('x') and blue gain ('y') to the color coordinates. ( x : 263, y : 267 )
* Do not adjust the green gain and sub-contrast (Y) data.



Picture 4-4 Toshiba ABL Pattern




High light
Measurement point




3-6
3 Alignments and Adjustments

3-4 TORINO Micom Update
3-4-1 Installing G-Probe
1. Uncompress GProbe5.1.0.18.zip.
2. Run GProbe5.1.0.18.exe.
3. The files are created in the C: Program Files Genesis Microchip GProbe 5 folder.
4. Copy the ispoak_spi.hex file to the C: Program Files Genesis Microchip GProbe 5 folder.
5. Uncompress FLI5961-AC_GProbe_S0006-CSC-33B.zip.
6. Three files are extracted (FLI5961.Chip.GProbe, FLI5961.chm, outputlog.txt).
7. Copy all 3 files to the C: Program Files Genesis Microchip GProbe 5 ChipDB folder.
8. Run GProbe.exe in the C: Program Files Genesis Microchip GProbe 5 folder. The G-Probe program
is created.









3-7
3 Alignments and Adjustments

3-4-2 Connecting to the MAIN PCB


Switch off










Connect to the MAIN PCB. Connect to the PC




3-8
3 Alignments and Adjustments

3-4-3 Update Procedures
1. Open mgm.txt in the C: Program Files Genesis Microchip GProbe 5 folder.

2. The following result will appear.
//
// Batch file to program a sPI serial flash using ISP.
// Moving the stack to high memory area is now taken care of in IROM
// through the "Reset 0" command. Assumes the ISP driver is in the same
// directory as this file. Change ISP driver path in "fastFlashWrite"
// command, if different from current directory.
//
debugon

SetBuffer 0x2000 0x800
delay 200
Reset 0
delay 500

// SPI flash driver
RAMWrite ispoak_spi.hex

Run 0x500
delay 100

// Optional - Get Flash ID. The second parameter is a don't care
//FLASHCRC 0xff0000 0x20000


// Command delay for flash erase
SetDelay 1000 9000

FlashErase


// Command delay for flash write. This is for each flash write packet (upto 4 k Bytes)
SetDelay 1000 3000

// Change this line to point to a file in a different location, if needed
//fastFlashWrite C: Proj OAK APP-59xx debug obj 59xx_proj.hex
fastFlashWrite C: C: Program Files Genesis Microchip GProbe 5 T_TRNNUS.hex

// Optional - Get CRC of 128 kByte flash. For other sizes, change second parameter
// accordingly
//FLASHCRC 0x80000 0x20000
// to reset the monitor after programming the flash using DDC2BI ONLY:
// Un-comment the following three lines (PLEASE - FOR DDC2BI PORT SELECTED ONLY)
//0x8000=1
//0x8003=0
//0x8027=1



3-9
3 Alignments and Adjustments

The Micom program is to be copied to the folder marked in red and the name of the program is to be the
same as the file name marked in blue.
(If the Micom program is not in the folder marked in red, change the path to the folder which includes the
Micom program and then save the file.)

3. When completing all the procedures above, connect the Jig and the PCB, and run the G-Probe program.
After that
Enter 'test 10' as shown in the following figure and press Enter or click the Execute button.
If the result appears as shown in the following figure, it is properly connected.




3-10
3 Alignments and Adjustments

4. Enter 'batch mgm.txt' as show in the following figure and press Enter or click the Execute button to
update Micom.




If the MICOM update is successfully completed, the
above message appears.




3-11
3 Alignments and Adjustments

Memo