Text preview for : Sharp bulletin 51Cs03H-044.pdf part of Sharp Sharp_Bulletins_2 Sharp_Bulletins_2



Back to : Sharp_Bulletins_2.zip | Home

CTV2000 03 03
Month of Issue: Classification:

TELEVISION TECHNICAL BULLETIN
MODELS 51CS03H 59CSD8H 51CS05H 66CS03H 59CS03H 66CS05H

March 2000 White Page 1 of 1

59CS05H 66CSD8H

SYMPTOM A bright line appears at the top of the frame (approximately one-inch down) if it is adjusted correctly. Usually the customer complains that the frame has come down about half an inch at the top of the picture (no fold over). This cannot be removed by adjustment.

CAUSE

Failure of C512 or C517.

ACTION

Replace C512 and C517 (22uF, 25V).

Sharp Electronics (UK) Limited
Reference JC03032000-2 Revision 1

White ­ Carry out as required Yellow ­ Carry out as required and whenever the unit comes in for service Red ­ Carry out on all units