Text preview for : disassembly-BM350.pdf part of DE`LONGHI disassembly-BM350 DE`LONGHI disassembly-BM350.pdf
Back to : disassembly-BM350.pdf | Home
Spares - BM350 Disassembly & re-assembly instructions Page 1 of 4
BM350
The following procedures are aimed to help with dismantling and service repairs.
Always disconnect the appliance from mains supply prior to removal of the covers and suitably protect the finish on the
casings.
Click on the pictures to open a larger version in a seperate window.
Raise the lid to remove.
To remove the control panel
assembly, undo the two securing
screws indicated by the yellow arrows,
then lever off at the points indicated
by the red arrows. The BM250 control
panel assembly is secured by three
screws, two on the side and one at the
back.
This shows the main PCB wiring. The
control panel PCB is fitted below.
http://www.kenwoodservice.co.uk/product-files-kar/guide-BM350.htm 29/04/2009
Spares - BM350 Disassembly & re-assembly instructions Page 2 of 4
View with the control panel removed.
The convector fan & thermistor
position.
http://www.kenwoodservice.co.uk/product-files-kar/guide-BM350.htm 29/04/2009
Spares - BM350 Disassembly & re-assembly instructions Page 3 of 4
To gain access to the internal parts,
first remove the top surround which is
secured by six screws.
With the appliance upside down,
remove all the base screws including
the feet, then ease off the outer body.
The chassis assembly is removed
through the top.
http://www.kenwoodservice.co.uk/product-files-kar/guide-BM350.htm 29/04/2009
Spares - BM350 Disassembly & re-assembly instructions Page 4 of 4
View with the outer casing removed.
Please note: it is necessary to
remove the outer casing when
replacing the thermistor on the
BM350, whereas on the BM250 the
thermistor is accessible with only the
control panel assembly removed.
Twin thermal fuses 172