Text preview for : TEK TDS 500D_252C 600C_252C 700D_252C Reference.pdf part of Tektronix TEK TDS 500D 252C 600C 252C 700D 252C Reference Tektronix TEK TDS 500D_252C 600C_252C 700D_252C Reference.pdf
TDS 500D, TDS 600C & TDS 700D Digitizing Oscilloscopes 071-0504-00 To Display a Waveform:
1 Attach a probe to CH 1 2 Press 3 Press 4 Adjust VERTICAL and HORIZONTAL and hook the probe to your CH 1. AUTOSET. POSITION and SCALE. signal.
Device under test
Copyright E Tektronix, Inc., 1998. Printed in U.S.A. To Set Up Using a Menu:
1 Press any of the front panel menu buttons. Use SHIFT for the alternate (blue) menus.
2 Select an item from the main (bottom) menu.
The readout indicates the value that you can adjust 3 Select an item from the side menu, if displayed. with the general purpose knob or keypad.
Adjustable menu item value
4 Adjust menu item values using the general purpose knob or by entering numbers on the keypad. General purpose knob
Keypad
End your entry by pressing ENTER ( ). To Select a Trigger: Trigger Selections (On some models, Ax 1 & Ax 2 replace Ch 3 & Ch 4) 1 Press TRIGGER MENU. TYPE TYPE CLASS CLASS CLASS
Source
Data Source Define Inputs
Define Inputs Select any one of Define levels High, Define levels High, Select one of Ch 1 thru Ch 4, Low, or Don't Care Low, or Don't Care Ch 1 thru Ch 4 as Line, or DC Aux for Ch 1 thru Ch 4 for Ch 1 thru Ch 3 the data source 2 Select a trigger type or parameter from the Select edge for the Do not select the main menu. clock (always Ch 4) same channel used as the clock source This symbol
Select one of
Define Logic
Define Logic
Clock Source indicates a Positive AND AND
Slope pop-up menu Ch 1 thru Ch 4 as the clock source
Negative OR OR Select the clock edge
Do not select the NAND NAND same channel used as the data source
3 Set TRIGGER MAIN LEVEL. NOR NOR
Levels Set Thresholds
Set Thresholds Set a threshold Set a threshold Level
Level level for each of level for each of Clock Ch 1 thru Ch 4 the pattern channels, Ch 1 thru Ch 3, and the clock, Ch 4. Data
"T" shows the Arrow shows Title of the trigger position the trigger level side menu Set level or select Set levels or select preset level based preset levels based on TTL or ECL logic on TTL or ECL logic
Select and set the Coupling
Trigger When
Trigger When
Setup/Hold Times DC Goes TRUE Goes TRUE Setup Time
Select and set the AC Goes FALSE Goes FALSE Hold Time
HF TRUE for Reject less than1
LF TRUE for Reject more than1
Press to display the pop-up menus Removes the Noise Rej (DC Press again to make a selection menus from Low Sensitivity) the screen A pop-up selection changes the other main menu items 1Qualification by time TYPE TYPE TYPE