Text preview for : MW-30LZ10 Service Manual.pdf part of LG MW-30LZ10 Service Manual LG LCD MW-30LZ10 Service Manual.pdf



Back to : MW-30LZ10 Service Manual. | Home

website:http://biz.LGservice.com
e-mail:http://www.LGEservice.com/techsup.html




LCD MONITOR
SERVICE MANUAL
CHASSIS : MF-02HA

MODEL : MW-30LZ10
CAUTION
BEFORE SERVICING THE CHASSIS,
READ THE SAFETY PRECAUTIONS IN THIS MANUAL.




Aug., 2002
P/NO : 3828VD0120B Printed in Korea
CONTENTS




Contents .................................................................................................. 2

Safety Precautions ..................................................................................3

Adjustment Instruction ............................................................................4

Troubleshooting .......................................................................................6

Printed Circuit Board ...............................................................................7

Block Diagram.........................................................................................11

Exploded View ...................................................................................... 16

Exploded View Parts List .......................................................................17

Replacement Parts List ........................................................................ 18

SVC. Sheet .................................................................................................




- 2 -
SAFETY PRECAUTIONS

IMPORTANT SAFETY NOTICE
Many electrical and mechanical parts in this chassis have special safety-related characteristics. These parts are identified by in
the Schematic Diagram and Replacement Parts List.
It is essential that these special safety parts should be replaced with the same components as recommended in this manual to
prevent X-RADIATION, Shock, Fire, or other Hazards.
Do not modify the original design without permission of manufacturer.



General Guidance Leakage Current Cold Check(Antenna Cold Check)
With the instrument AC plug removed from AC source,
An lsolation Transformer should always be used during connect an electrical jumper across the two AC plug prongs.
the servicing of a receiver whose chassis is not isolated from Place the AC switch in the on positioin, connect one lead of
the AC power line. Use a transformer of adequate power rating ohm-meter to the AC plug prongs tied together and touch other
as this protects the technician from accidents resulting in ohm-meter lead in turn to each exposed metallic parts such as
personal injury from electrical shocks. antenna terminals, phone jacks, etc.
If the exposed metallic part has a return path to the chassis, the
It will also protect the receiver and it's components from being measured resistance should be between 1M and 5.2M.
damaged by accidental shorts of the circuitary that may be When the exposed metal has no return path to the chassis the
inadvertently introduced during the service operation. reading must be infinite.
An other abnormality exists that must be corrected before the
If any fuse (or Fusible Resistor) in this TV receiver is blown, receiver is returned to the customer.
replace it with the specified.
Leakage Current Hot Check (See below Figure)
When replacing a high wattage resistor (Oxide Metal Film Plug the AC cord directly into the AC outlet.
Resistor, over 1W), keep the resistor 10mm away from PCB. Do not use a line Isolation Transformer during this check.
Connect 1.5K/10watt resistor in parallel with a 0.15uF capacitor
Keep wires away from high voltage or high temperature parts. between a known good earth ground (Water Pipe, Conduit, etc.)
and the exposed metallic parts.
Due to high vacuum and large surface area of picture tube, Measure the AC voltage across the resistor using AC
extreme care should be used in handling the Picture Tube. voltmeter with 1000 ohms/volt or more sensitivity.
Do not lift the Picture tube by it's Neck. Reverse plug the AC cord into the AC outlet and repeat AC
voltage measurements for each esposed metallic part. Any
Before returning the receiver to the customer, voltage measured must not exceed 0.75 volt RMS which is
corresponds to 0.5mA.
always perform an AC leakage current check on the exposed In case any measurement is out of the limits sepcified, there is
metallic parts of the cabinet, such as antennas, terminals, etc., possibility of shock hazard and the set must be checked and
to be sure the set is safe to operate without damage of repaired before it is returned to the customer.
electrical shock.
Leakage Current Hot Check circuit

AC Volt-meter




Good Earth Ground
such as WATER PIPE,
To Instrument's CONDUIT etc.
0.15uF
exposed
METALLIC PARTS


1.5 Kohm/10W




- 3 -
ADJUSTMENT INSTRUCTION

1. Application Object 3-2. EDID (The Extended Display
These instructions are applied to all of the MODELS of LCD Identification Data) Adjustment
MONITOR, MF-02HA. (1) This is the function that is made for the realization of "Plug
and Play" which makes possible to use the user
environment right after reorganization by communicating
with monitor automatically.
2. Notes
(1) Because this is not a hot chassis, it is not necessary to use (2) EDID DATA for DVI of MF-02HA
an isolation transformer. However, the use of isolation
transformer will help protect test instrument. EDID table =
(2) Adjustment must be done in the correct order. But, it can 00 01 02 03 04 05 06 07 08 09
be changed in consideration of mass production. _________________________________
(3) The adjustment must be performed in the circumstance of 000 | 00 FF FF FF FF FF FF 00 1E 6D
25