Text preview for : LG_42PC3DV_PA51D_[SM].pdf part of LG LG 42PC3DV PA51D [SM] LG Monitor LG_42PC3DV_PA51D_[SM].pdf



Back to : LG_42PC3DV_PA51D_[SM].pdf | Home

CANADA : http//biz.lgservice.com
USA : http//www.lgservice.com
: http//biz.lgservice.com




PLASMA TV
SERVICE MANUAL
CHASSIS : PA-51D

MODEL : 42PC3DV 42PC3DV-UD
MODEL : 42PC3D 42PC3D-UD
CAUTION
BEFORE SERVICING THE CHASSIS,
READ THE SAFETY PRECAUTIONS IN THIS MANUAL.
SAFETY PRECAUTIONS

IMPORTANT SAFETY NOTICE
Many electrical and mechanical parts in this chassis have special safety-related characteristics. These parts are identified by in
the Schematic Diagram and Replacement Parts List.
It is essential that these special safety parts should be replaced with the same components as recommended in this manual to
prevent X-RADIATION, Shock, Fire, or other Hazards.
Do not modify the original design without permission of manufacturer.



General Guidance Leakage Current Hot Check (See below Figure)
Plug the AC cord directly into the AC outlet.
An lsolation Transformer should always be used during Do not use a line Isolation Transformer during this check.
the servicing of a receiver whose chassis is not isolated from Connect 1.5K/10watt resistor in parallel with a 0.15uF capacitor
the AC power line. Use a transformer of adequate power rating between a known good earth ground (Water Pipe, Conduit, etc.)
as this protects the technician from accidents resulting in and the exposed metallic parts.
personal injury from electrical shocks. Measure the AC voltage across the resistor using AC
voltmeter with 1000 ohms/volt or more sensitivity.
It will also protect the receiver and it's components from being Reverse plug the AC cord into the AC outlet and repeat AC
damaged by accidental shorts of the circuitary that may be voltage measurements for each esposed metallic part. Any
inadvertently introduced during the service operation. voltage measured must not exceed 0.75 volt RMS which is
corresponds to 0.5mA.
If any fuse (or Fusible Resistor) in this monitor is blown, replace In case any measurement is out of the limits sepcified, there is
it with the same specified type. possibility of shock hazard and the set must be checked and
repaired before it is returned to the customer.
When replacing a high wattage resistor (Oxide Metal Film
Resistor, over 1W), keep the resistor 10mm away from PCB.

Keep wires away from high voltage or high temperature parts. Leakage Current Hot Check circuit
AC Volt-meter

Leakage Current Cold Check(Antenna Cold Check)
With the instrument AC plug removed from AC source,
connect an electrical jumper across the two AC plug prongs. Good Earth Ground
Place the AC switch in the on positioin, connect one lead of such as WATER PIPE,
ohm-meter to the AC plug prongs tied together and touch other To Instrument's CONDUIT etc.
ohm-meter lead in turn to each exposed metallic parts such as 0.15uF
exposed
antenna terminals, phone jacks, etc. METALLIC PARTS
If the exposed metallic part has a return path to the chassis, the
measured resistance should be between 1M and 5.2M.
When the exposed metal has no return path to the chassis the 1.5 Kohm/10W
reading must be infinite.
An other abnormality exists that must be corrected before the
receiver is returned to the customer.
CANADA: LG Electronics Canada, Inc. 550 Matheson
Boulevard East Mississauga, Ontario L4Z 4G3

USA : LG Customer Interactive Center
P.O.Box 240007, 201 James Record Road Huntsville,
AL 35824
Digital TV Hotline 1-800-243-0000




- 2 -
TABLE OF CONTENTS

DESCRIPTION OF CONTROLS ...........................................4


SPECIFICATIONS.................................................................8


ADJUSTMENT INSTRUCTIONS ..........................................9


BLOCK DIAGRAM...............................................................13


EXPLODED VIEW..........................................................16,18


EXPLODED VIEW PARTS LIST ....................................17,19


REPLACEMENT PARTS LIST ............................................20


SCHEMATIC DIAGRAM..........................................................


PRINTED CIRCUIT BOARDS .................................................




- 3 -
DESCRIPTION OF CONTROLS

Controls

- This is a simplified representation of front panel.
- Here shown may be somewhat different from your TV.




CH CHANNEL (D, E)
Buttons


VOLUME (F,G)
VOL
Buttons

ENTER
ENTER Button
MENU
MENU Button
INPUT
INPUT Button


(Power) Button
Remote Control Sensor

Power/Standby Indicator