ADJUSTMENT INSTRUCTION

1. Application Object 3-2. EDID (The Extended Display
These instructions are applied to all of the MODELS of LCD Identification Data) Adjustment
MONITOR, MF-02HA. (1) This is the function that is made for the realization of "Plug
and Play" which makes possible to use the user
environment right after reorganization by communicating
with monitor automatically.
2. Notes
(1) Because this is not a hot chassis, it is not necessary to use (2) EDID DATA for DVI of MF-02HA
an isolation transformer. However, the use of isolation
transformer will help protect test instrument. EDID table =
(2) Adjustment must be done in the correct order. But, it can 00 01 02 03 04 05 06 07 08 09
be changed in consideration of mass production. _________________________________
(3) The adjustment must be performed in the circumstance of 000 | 00 FF FF FF FF FF FF 00 1E 6D
25