Text preview for : EWT19S2.pdf part of EMERSON EWT19S2 EMERSON TV EWT19S2 EWT19S2.pdf
Back to : EWT19S2.pdf | Home
SERVICE MANUAL
19" COLOR TELEVISION
EWT19S2
IMPORTANT SAFETY NOTICE
Proper service and repair is important to the safe, reliable operation of all
Funai Equipment. The service procedures recommended by Funai and de-
scribed in this service manual are effective methods of performing service
operations. Some of these service special tools should be used when and
as recommended.
It is important to note that this service manual contains various CAUTIONS
and NOTICES which should be carefully read in order to minimize the risk of
personal injury to service personnel. The possibility exists that improper
service methods may damage the equipment. It also is important to under-
stand that these CAUTIONS and NOTICES ARE NOT EXHAUSTIVE. Funai
could not possibly know, evaluate and advice the service trade of all con-
ceivable ways in which service might be done or of the possible hazardous
consequences of each way. Consequently, Funai has not undertaken any
such broad evaluation. Accordingly, a servicer who uses a service proce-
dure or tool which is not recommended by Funai must first use all precau-
tions thoroughly so that neither his safety nor the safe operation of the
equipment will be jeopardized by the service method selected.
TABLE OF CONTENTS
Specifications ........................................................ 1-1 CBA Views and Test Points.................................. 7-11
Important Safety Precautions................................ 2-1 Wave Forms .......................................................... 8-1
Standard Notes for Servicing ................................ 3-1 Wiring Diagram...................................................... 9-1
Disassembly Instructions ...................................... 4-1 IC Pin Function .................................................... 10-1
Electrical Adjustment Instructions ......................... 5-1 Cabinet Exploded View ....................................... 11-1
Block Diagram....................................................... 6-1 Packing Exploded View ....................................... 11-3
Schematic Diagram / CBA's and Test Points ....... 7-1 Mechanical Parts List .......................................... 12-1
Schematic Diagram .............................................. 7-3 Electrical Parts List .............................................. 13-1
SPECIFICATIONS
ANT. Input ------------------ 75ohm Unbal., F type
Reference Level ----------- 20Vp-p (CRT Green Cathode)
Test Input Signal ---------- 400Hz 30% modulation
Description Condition Unit Nominal Limit
1. Intermediate Freq. Picture MHz 45.75 -
Sound MHz 41.25 -
2. Peak Picture Sens VHF dB