UNITEST
Bedienungsanleitung
Best.-Nr. 93470 / 93480
Instruction Manual
Cat. No. 93470 / 93480
Mode d´emploi
Réf. 93470 / 93480



CHB 7
CHB 37
Inhaltsverzeichnis Seite
1.0 Einleitung / Lieferumfang 3
2.0 Sicherheitsmaßnahmen 3
3.0 Bedienelemente und Anschlüsse 5
4.0 Durchführen von Messungen 6
4.1 Vorbereitung und Sicherheitsmaßnahmen 6
4.2 Durchführen von Strommessungen 7
4.2.1 Gleichstrommessung
(nur UNITEST Stromzange CHB 37) 7
4.2.2 Wechselstrommessung 7
4.3 Durchführen von Spannungsmessungen 8
4.3.1 Gleichspannungsmessung 9
4.3.2 Wechselspannungsmessung 9
4.4 Durchführen von Frequenzmessungen 9
4.5 Durchführen von Widerstandsmessungen 10
4.6 Durchführen von Durchgangsprüfungen /
Diodenprüfungen 11
4.6.1 Durchgangsprüfung 11
4.6.2 Diodenprüfung 11
4.7 Echteffektivwertmessung (True RMS) / Crestfaktor
(nur UNITEST Stromzange CHB 37) 11
4.8 MIN/MAX-Peak-Messung 12
5.0 Wartung 13
5.1 Batteriewechsel 13
6.0 Technische Daten 14




Auf dem Gerät und in der Bedienungsanleitung vermerkte
Hin-weise:

ACHTUNG ! Warnung vor einer Gefahrenstelle,
Bedienungsanleitung beachten.
VORSICHT ! Gefährliche Spannung.
Durchgängige doppelte oder verstärkte Isolierung ent-
sprechend Klasse II IEC 61140.
Kennzeichnung elektrischer und elektronischer Geräte (WEEE
Richtlinie 2002/96/EG).
Konformitätszeichen, bestätigt die Einhaltung der gültigen
Richtlinien. Die Anforderungen der EMV-Richtlinie
89/336/EWG und der Niederspannungsrichtlinie 73/23/EWG
mit den jeweils betreffenden Normen werden ebenfalls
eingehalten.



2
1.0 Einleitung / Lieferumfang
Die UNITEST Stromzangen CHB 7 und CHB 37 sind universell ein-
setzbare Vielfachinstrumente. Die Meßgeräte werden nach den
neuesten Normen IEC 61010, EN 61010 gebaut und gewährleisten
ein sicheres und zuverlässiges Arbeiten. Die Stromzangen sind im
handwerklichen und industriellen Bereich eine wertvolle Hilfe bei
allen Standardmeßaufgaben. Die UNITEST Stromzange CHB 37
ermöglicht zusätzlich die Messung des Echteffektivwertes (True
RMS). Dies ist vor allem bei nichtsinusförmigen Strömen und
Spannungen wichtig.

· Echteffektivwertmessung (True RMS)
(nur UNITEST Stromzange CHB 37)
· 33/4stellige, digitale LC-Anzeige mit Bargraph
· Automatische und manuelle Meßbereichswahl für Strom-,
Spannungs-, Widerstands- und Frequenzmessung
· Zangenöffnung 46 mm
· Auto-Power-Off-Funktion
· Integrierter Meßwertspeicher
· MIN/MAX-Wert-Funktion
· Nullabgleich/Relativ-Funktion
Die UNITEST Stromzangen CHB 7 und CHB 37 werden komplett
mit Meßleitungen geliefert. Überprüfen Sie nach dem Auspacken,
ob das Gerät und das Zubehör vollständig vorhanden ist.

Im Lieferumfang sind enthalten:

1 St. UNITEST Stromzange CHB 7oder UNITEST Stromzange CHB 37
2 St. Meßleitungen mit Prüfspitzen (rot, schwarz)
1 St. Batterie 9 V IEC 6LR61
1 St. Bereitschaftstasche
1 St. Bedienungsanleitung

Weiteres Zubehör wie Meßleitungen, Prüfspitzen, Klemmen usw.
finden Sie im UNITEST-Hauptkatalog.


2.0 Sicherheitsmaßnahmen
Die UNITEST Stromzangen CHB 7 und CHB 37 wurden gemäß den
Sicherheitsbestimmungen für elektronische Meßgeräte gebaut,
geprüft und haben das Werk in sicherheitstechnisch einwandfreiem
Zustand verlassen.
Um diesen Zustand zu erhalten, muß der Anwender die Sicher-
heitshinweise in dieser Anleitung beachten.

Die Bedienungsanleitung enthält Informationen und Hinweise,
die zu einer sicheren Bedienung und Nutzung des Gerätes
notwendig sind.
3
Vor der Verwendung des Gerätes ist die Bedienungsanleitung auf-
merksam zu lesen und in allen Punkten zu befolgen.

Wird die Anleitung nicht beachtet oder sollten Sie es versäumen,
die Warnungen und Hinweise zu beachten, können ernste oder
lebensgefährliche Verletzungen bzw. Beschädigungen des Ge-
rätes eintreten.



Um einen elektrischen Schlag zu vermeiden, sind Vorsichts-
maßnahmen zu beachten, wenn mit Spannungen größer 120 V
(60 V) DC oder 50 V (25 V) eff AC gearbeitet wird. Diese
Werte stellen nach DIN VDE die Grenze der noch berührbaren
Spannungen dar (Werte in Klammern gelten für z.B. medi-
zinische oder landwirtschaftliche Bereiche).

Vergewissern Sie sich vor jeder Messung, daß die Meß-
leitungen und die Prüfgeräte in einwandfreiem Zustand sind.

Die Meßleitungen und Prüfspitzen dürfen nur an den vorge-
sehenen Handgriffen angefaßt werden. Das Berühren der
Prüfspitzen ist unter allen Umständen zu vermeiden.

Bei sämtlichen Arbeiten müssen die Unfallverhütungsvorschriften
der gewerblichen Berufsgenossenschaften für elektrische Anlagen
und Betriebsmittel beachtet werden

Die Prüfgeräte dürfen nur in den spezifizierten Meßbereichen
eingesetzt werden.

Vor dem Öffnen müssen die Geräte ausgeschaltet und von allen
Meßkreisen getrennt werden.

Vermeiden Sie eine Erwärmung der Geräte durch direkte Sonnen-
einstrahlung. Nur so kann eine einwandfreie Funktion und eine
lange Lebensdauer gewährleistet werden.

Das Gerät darf nur unter den Bedingungen und für die Zwecke
eingesetzt werden, für die es konstruiert wurde. Hierzu sind be-
sonders die Sicherheitshinweise, die Technischen Daten mit den
Umgebungsbedingungen und die Verwendung in trockener
Umgebung zu beachten.

Die Betriebssicherheit ist bei Modifizierung oder Umbauten
nicht mehr gewährleistet.




4
3.0 Bedienelemente und Anschlüsse
1. Meßwertaufnehmer (Stromzange)
2. HOLD-Taste zum "Festhalten" von Meßwerten
3. Meßart-Wahlschalter
4. Nullabgleich/Relativ-Funktion
5. Manuelle Meßbereichswahl
6. Digitale Anzeige
7. Eingangsbuchsen für Spannungs-, Widerstands-, Frequenz-
messung und Durchgangs- und Diodenprüfung
8. MIN/MAX-Wertfunktion /
Peak-Erfassung (nur UNITEST Stromzange CHB 37)
9. Griffbereich mit Griffschutzkragen




5
Auto-Power-Off
Die UNITEST Stromzangen CHB 7 und CHB 37 sind mit einer
Auto-Power-Off-Funktion versehen. Wurde nach 30 min. keine
Funktion getätigt, schalten sich die Geräte automatisch ab. Mit der
Taste " " können die Geräte wieder aktiviert werden. Die Auto-
Power-Off-Funktion verhindert ein zu schnelles Entladen der
Batterie, wenn die Geräte versehentlich eingeschaltet wurden. Die
Funktion wird ausgeschaltet, wenn während dem Einschalten der
Stromzange eine Taste (4,5 oder 8) gedrückt wird.

Relativwertmessung
Die UNITEST Stromzangen CHB 7 und CHB 37 sind mit einer
Relativwert-Funktion versehen. Hiermit können Sie während einer
Messung den aktuellen Wert auf 0 setzen und den relativen Wert
zur jeweiligen Messung ermitteln.


4.0 Durchführung von Messungen
4.1 Vorbereitung und Sicherheitsmaßnahmen

Batterien einlegen:
Bevor das Gerät in Betrieb genommen wird, müssen die Batterien
eingelegt werden. Dazu wird folgendermaßen vorgegangen:

4Das Gerät vom Meßkreis trennen und alle Meßleitungen
entfernen.

4Öffnen Sie das Gehäuse, indem Sie die 3 Schrauben auf der
Rückseite des Gerätes entfernen.

4Neue Batterie vom Typ 9 V IEC 6LR61 richtig gepolt einsetzen
und das Gehäuse wieder schließen. Achten Sie darauf, daß
keine Leitungen zwischen den Gehäusehälften eingeklemmt
werden.

4Nun können Sie mit den Messungen beginnen.

· Meßart-Wahlschalter auf die gewünschte Funktion stellen,
bevor Sie die Prüfspitzen mit dem Meßobjekt verbinden.
· Vor dem Umschalten auf eine neue Funktion oder in einem
anderen Meßbereich sind die Meßleitungen stets von den
Prüfobjekten zu entfernen.
· Verwenden Sie die Geräte nur in trockener und sauberer
Umgebung. Schmutz und Feuchtigkeit setzen die Isolations-
wiederstände herab und können insbesondere bei großen
Spannungen zu elektrischen Schlägen führen.
· Betreiben Sie die Geräte nur in den angegebenen Meß-
bereichen.
6
· Prüfen Sie die Geräte vor jeder Benutzung auf einwandfreie
Funktion (z.B. an einer bekannten Strom- bzw. Spannungsquelle).

· Achten Sie darauf, daß die Meßleitungen in einwandfreiem
Zustand sind.

4.2 Durchführen von Strommessungen

Messen Sie niemals Strom in nicht isolierten Meßkreisen mit
einer Nennspannung von mehr als 250 V !

Die Meßleitungen und Prüfspitzen dürfen nur an den dafür
vorgesehenen Handgriffen angefaßt werden. Das Berühren
der Prüfspitzen ist unter allen Umständen zu vermeiden.

4.2.1 Gleichstrommessung (nur UNITEST Stromzange CHB 37)
4Stellen Sie den Meßart-Wahlschalter (3) auf Stellung " A".

4Drücken Sie die Taste " " (4). Achten Sie darauf, daß
"000.0" angezeigt wird.

4Der günstigste Meßbereich wird eingestellt. Wenn Sie den
Meßbereich manuell einstellen wollen, drücken Sie bitte die
Taste " ".

4Öffnen Sie die Stromzange, und umschließen Sie den Stromleiter.
Achten Sie darauf, daß die Zange den Stromleiter vollständig
umschließt und kein Luftspalt vorhanden ist.
Um eine positive Anzeige zu erhalten, muß der Strom in Rich-
tung des Pfeils auf der Zange fließen.
Wenn die Anzeige während der Messung nicht einsehbar ist,
kann der Meßwert mit dem Schalter (2) " HOLD" festge-
halten werden. Danach wird die Zange vom Meßobjekt entfernt
und der auf der Anzeige gespeicherte Wert abgelesen.

4.2.2 Wechselstrommessung

4Stellen Sie den Meßart-Wahlschalter (3) auf Stellung " A".

4Der günstigste Meßbereich wird eingestellt.
Wenn Sie den Meßbereich manuell einstellen wollen, drücken
Sie bitte die Taste " ".

4Öffnen Sie die Stromzange, und umschließen Sie den Strom-
leiter. Achten Sie darauf, daß die Zange den Stromleiter voll-
ständig umschließt und kein Luftspalt vorhanden ist.

Wenn die Anzeige während der Messung nicht einsehbar ist, kann
der Meßwert mit dem Schalter (2) " HOLD" festgehalten wer-
den. Danach wird die Zange vom Meßobjekt entfernt und der auf
der Anzeige gespeicherte Wert abgelesen.
7
Korrekte Strommessung




Keine korrekte Messung, die Anzeige ist gleich null.
Nach der ersten Kirchhoffschen Regel ist die Summe aller Ströme
gleich null. Jedoch läßt sich mit dieser Meßanordnung mit einer
empfindlichen Stromzange (z.B. UNITEST Leckstromzange CHB 3
Best.-Nr. 93481) der Ableitstrom des Verbrauchers messen.


4.3 Durchführen von Spannungsmessungen

Es dürfen nicht mehr als 600 V AC und 600 V DC an den
Eingangsbuchsen angelegt werden. Bei Überschreiten dieser
Grenzwerte droht eine Beschädigung des Gerätes und eine
Gefährdung des Bedieners.

Entfernen Sie die Prüfspitzen vom Meßobjekt, bevor Sie eine
andere Meßart auswählen.
8
Die Meßleitungen und Prüfspitzen dürfen nur an den dafür
vorgesehenen Handgriffen angefaßt werden. Das Berühren der
Prüfspitzen ist unter allen Umständen zu vermeiden.

4.3.1 Gleichspannungsmessung

4Stellen Sie den Meßart-Wahlschalter (3) auf " ".

4Verbinden Sie die schwarze Meßleitung mit dem "COM"-An-
schluß und die rote Meßleitung mit dem "+"-Anschluß.

4Verbinden Sie die Prüfspitzen mit dem Prüfobjekt. Lesen Sie
den Meßwert von der Anzeige ab.

4Der günstigste Meßbereich wird eingestellt.
Sollten Sie den Meßbereich manuell einstellen wollen, drücken
Sie bitte die Taste " ".

Falls die Anzeige während der Messung nicht einsehbar ist, kann
der Meßwert mit dem Taster (2) " " festgehalten werden.
Danach werden die Meßleitungen vom Meßobjekt entfernt und der
auf der Anzeige gespeicherte Wert abgelesen.

4.3.2 Wechselspannungsmessung

4Stellen Sie den Meßart-Wahlschalter (3) auf " ".

4Verbinden Sie die schwarze Meßleitung mit dem "COM"-An-
schluß und die rote Meßleitung mit dem "+"-Anschluß.

4Verbinden Sie die Prüfspitzen mit dem Prüfobjekt. Lesen Sie
den Meßwert von der Anzeige ab.

4Der günstigste Meßbereich wird eingestellt.
Sollten Sie den Meßbereich manuell einstellen wollen, drücken
Sie bitte die Taste " ".

Falls die Anzeige während der Messung nicht einsehbar ist, kann
der Meßwert mit dem Taster (2) " " festgehalten werden.
Danach werden die Meßleitungen vom Meßobjekt entfernt und der
auf der Anzeige gespeicherte Wert abgelesen.

4.4 Durchführen von Frequenzmessungen

Messen Sie niemals Strom in nichtisolierten Meßkreisen mit
einer Nennspannung von mehr als 250 V!

Es dürfen nicht mehr als 600 V AC und 600 V DC an den
Eingangsbuchsen angelegt werden. Bei Überschreiten dieser
Grenzwerte droht eine Beschädigung des Gerätes und eine
Gefährdung des Bedieners.
9
Entfernen Sie die Prüfspitzen vom Meßobjekt, bevor Sie eine
andere Meßart auswählen.
Die Meßleitungen und Prüfspitzen dürfen nur an den dafür
vorgesehenen Handgriffen angefaßt werden. Das Berühren der
Prüfspitzen ist unter allen Umständen zu vermeiden.

Mit den UNITEST Stromzangen haben Sie die Möglichkeit, in beiden
Meßarten (Wechselstrom- und Wechselspannungsmes-sung) die
Frequenz zu messen.

4Stellen Sie den Meßart-Wahlschalter (3) auf Frequenzmessung
"Hz".
4Strommessung: Öffnen Sie die Stromzange, und umschließen
Sie den Stromleiter. Achten Sie darauf, daß die Zange den
Stromleiter vollständig umschließt und kein Luftspalt vorhan-
den ist.
Spannungsmessung: Verbinden Sie die schwarze Meßleitung
mit dem "COM"-Anschluß und die rote Meßleitung mit dem
"+". Verbinden Sie die Prüfspitzen mit dem Prüfobjekt. Lesen
Sie den Meßwert von der Anzeige ab.

4Mit der Taste " " kann man die Eingangsempfindlichkeit
eingestellt werden.
Falls die Anzeige während der Messung nicht einsehbar ist, kann
der Meßwert mit dem Taster (2) " " festgehalten werden.
Danach werden die Meßleitungen vom Meßobjekt entfernt und der
auf der Anzeige gespeicherte Wert abgelesen.

4.5 Durchführen von Widerstandsmessungen

Der Prüfling muß spannungsfrei sein, messen Sie ggf. nach !

4Stellen Sie den Meßart-Wahlschalter (3) auf Widerstandsmes-
sung "V".
4Verbinden Sie die schwarze Meßleitung mit dem "COM"-An-
schluß und die rote Meßleitung mit dem "+"-Anschluß.

4Verbinden Sie die Prüfspitzen mit dem Prüfobjekt. Lesen Sie
den Meßwert von der Anzeige ab.

4Der günstigste Meßbereich wird eingestellt.
Sollten Sie den Meßbereich manuell wählen wollen, drücken Sie
bitte die Taste " ".

Falls die Anzeige während der Messung nicht einsehbar ist, kann
der Meßwert mit dem Taster (2) " " festgehalten werden.
Danach werden die Meßleitungen vom Meßobjekt entfernt und der
auf der Anzeige gespeicherte Wert abgelesen.
10
4.6 Durchführen von Durchgangsprüfungen/Diodenprüfungen
Der Prüfling muß spannungsfrei sein, messen Sie ggf. nach !

Nur UNITEST Stromzange CHB 37:
Mit der " "-Taste können Sie zwischen akustischer
Durch-gangsprüfung " " und Diodenprüfung " "
umschalten.

4.6.1 Durchgangsprüfung

4Stellen Sie den Meßart-Wahlschalter (3) auf Stellung
" + .
(Bei der UNITEST Stromzange CHB 7 auf Stellung " ")

4Drücken Sie die " "-Taste bis das " "-Symbol in der
LC-Anzeige erscheint.

4Verbinden Sie die schwarze Meßleitung mit dem "COM"-An-
schluß und die rote Meßleitung mit dem "+"-Anschluß.

4Verbinden Sie die Prüfspitzen mit dem Prüfobjekt.

Ist der Durchgangswiderstand kleiner als 40 V, ertönt ein Piepton.

4.6.2 Diodenprüfung
4Stellen Sie den Meßart-Wahlschalter (3) auf Stellung
" + ".
4Drücken Sie die " "-Taste, bis das " "-Symbol in der
LC-Anzeige erscheint.
4Verbinden Sie die schwarze Meßleitung mit dem "COM"-An-
schluß und die rote Meßleitung mit dem "+"-Anschluß.
4Verbinden Sie die rote Prüfspitze mit der Anode der Diode und
die schwarze Prüfspitze mit der Kathode der Diode. Ist die Diode
in Ordnung wird die Vorwärtsspannung der Diode angezeigt.

4.7 Echteffektivwertmessung (True RMS) / Crestfaktor
(nur UNITEST Stromzange CHB 37)

Echteffektivwertmessung (True RMS):
Handelsübliche Stromzangen zeigen den Mittelwert an und sind
deshalb nur für Gleichströme/-spannungen und reine sinusförmige
Wechselströme/-spannungen geeignet.
Ist der Wechselstrom oder die Wechselspannung nichtsinusförmig,
z.B. durch Verzerrungen infolge einer Phasenanschnittsteuerung,
muß eine Echteffektivwertmessung (True RMS) durchgeführt
werden. Die UNITEST Stromzange CHB 37 ist geeignet zur
Echt-effektivwertmessung.
11
Die untenstehende Tabelle beinhaltet den Vergleich der Meßergeb-
nisse zwischen der UNITEST Stromzange CHB 37 mit Echteffek-
tivwertmessung und denen von Stromzangen mit Mittelwert- und
Spitzenwerterfassung:




Crestfaktor:
Der Crestfaktor oder Scheitelfaktor gibt das Verhältnis von
Spitzenwert zu Effektivwert eines Signals an. Diese Kenngröße ist
besonders bei Echteffektivwertmeßgeräten (UNITEST Stromzange
CHB 37) zu beachten. Obwohl der Meßwert innerhalb des gewähl-
ten Meßbereiches liegt, kann die UNITEST Stromzange CHB 37
übersteuert sein und falsche Meßwerte liefern, wenn das zu
messende Signal zu hohe Spitzenwerte aufweist.




4.8 MIN/MAX-Peak-Messung

Mit der Taste MIN/MAX haben Sie die Möglichkeit, den größten
bzw. kleinsten Wert einer Meßreihe zu erfassen. Drücken Sie die
MIN/MAX-Taste einmal, so sind Sie im MIN-Modus, d.h. der
kleinste Wert wird erfaßt, drücken Sie noch einmal, so sind Sie im
MAX-Modus, d.h. der größte Wert wird erfaßt. Wenn Sie ein
weiteresmal drücken, sind Sie wieder im Normalmodus.

Bei der UNITEST Stromzange CHB 37 haben Sie die Möglichkeit
der Spitzenwerterfassung im Wechselstrombereich. Dazu schalten
Sie das Gerät in den MAX-Modus und beginnen mit Ihrer Messung.
Eine Anwendung ist z.B. die Erfassung des Anlaufstromes bei
einem Wechselstrommotor.
12
5.0 Wartung
Die Geräte benötigen bei einem Betrieb gemäß der Bedienungs-
anleitung keine besondere Wartung.
Sollten die Geräte durch den täglichen Gebrauch schmutzig ge-
worden sein, können sie mit einem feuchten Tuch und etwas
mildem Haushaltsreiniger gereinigt werden.
Verwenden Sie niemals scharfe Reiniger oder Lösungsmittel.
Um die angegebenen Genauigkeiten der Meßergebnisse zu erhalten,
sollten die Geräte regelmäßig durch unseren Werksservice kali-
briert werden. Wir empfehlen ein Kalibrierintervall von einem Jahr.

5.1 Batteriewechsel
Wenn in der linken Ecke der Anzeige das Symbol " " er-
scheint, muß die Batterie ausgetauscht werden.

Gehen Sie bitte wie folgt vor:
4Trennen Sie die UNITEST Stromzange CHB 7/UNITEST
Stromzange CHB 37 vom Meßkreis und entfernen Sie alle Meß-
leitungen.
4Schalten Sie das Gerät aus.
4Öffnen Sie das Gehäuse, indem Sie die drei Schrauben auf der
Rückseite lösen.

4Entfernen Sie die verbrauchte Batterie.

4Setzen Sie die neue Batterie vom Typ 9 V IEC 6LR61 richtig ge-
polt ein, und schließen Sie das Gehäuse wieder.
Achten Sie darauf, daß keine Leitungen zwischen den Gehäuse-
hälften eingeklemmt werden.

4Nun können Sie wie gewohnt mit den Messungen fortfahren.

Bitte denken Sie an dieser Stelle auch an unsere Umwelt.
Werfen Sie verbrauchte Batterien nicht in den normalen Haus-
müll, sondern geben Sie die Batterien bei Sondermülldeponien
oder Sondermüllsammlungen ab.

Es müssen die jeweils gültigen Bestimmungen bzgl. der
Rücknahme, Verwertung und Beseitigung von verbrauchten
Batterien beachtet werden.

Werden die Geräte über einen längeren Zeitraum nicht benutzt,
müssen die Batterien entnommen werden. Sollte es zu einer
Verunreinigung der Geräte durch ausgelaufene Batterien
gekommen sein, müssen sie zur Reinigung und Überprüfung
ins Werk eingesandt werden.
13
6.0 Technische Daten (Änderungen vorbehalten)
Anzeige: 33/4stellige, digitale LC-Anzeige mit
Anzeige der Funktionen und Symbole
Balkenanzeige: 40 Segmente
Bereichswahl: automatisch oder manuell
Polaritätsanzeige: automatisch, "-"-Anzeige für negative
Eingangssignale
Überlaufanzeige: »4« blinkt in der Anzeige,
zusätzlich Dauerton
Meßrate: 20 Messungen/s. (Balkenanzeige),
2 Messungen/s. (Digitalanzeige)
max. Leiterdurchmesser: ca. 46 mm
Überspannungskategorie: CAT III, 600 V
Verschmutzungsgrad: 2
Höhe über N.N. bis zu 2000 m
Batterieanzeige: Bei entleerter Batterie erscheint
" "
Batteriekapazität: ca. 100 h
(UNITEST Stromzange CHB 37),
ca. 300 h
(UNITEST Stromzange CHB 7)
Stromversorgung: Batterie 9 V IEC 6LR61 (Alkaline)
Auto-Power-Off-Zeit: 30 min.
Bedienungstemperatur: 0° C ... 50° C
Lagertemperatur: -10° C ... 60° C
Feuchtigkeit: weniger als 70 % relative Luftfeuchte
Maße: 239 x 66 x 34 mm
Gewicht: ca. 365 g

Gleichstrom DC:
Meßbereich Auflösung Genauigkeit Überlastschutz
400 A 0,1 A 5 (2,5% v.M. + 5 Digits) 1100 A
1000 A 1A

Wechselstrom AC
(UNITEST Stromzange CHB 37 Crestfaktor 1 ... 10):
Meßbereich Auflösung Genauigkeit Überlastschutz Frequenz
400 A 0,1 A 5 (2,5% v.M. 1100 A 40 ... 450 Hz
1000 A 1A + 10 Digits)

14
Zusätzlicher Crestfaktorfehler bei nichtsinusförmigen Signalen
(nur UNITEST Stromzange CHB 37):
Crestfaktor Zusätzlicher Fehler (in % v.M.)
>1- 3 0,5 %
3- 5 1%
5 - 10 6%

Gleichspannung DC:
Meßbereich Auflösung Genauigkeit Eingangsimpedanz Überlastschutz

400 mV 0,1 mV > 1000 MV
4V 0,001 V 5 (1 % ca. 11 MV DC 1100 V
40 V 0,01 V v. M. AC 800 V
400 V 0,1 V + 2 Digits) ca. 10 MV
600 V 1V

Wechselspannung AC:
Meßbereich Auflösung Genauigkeit Eingangsimpedanz Überlastschutz Frequenz

4V 0,001 V 5(1,5 % ca. 11 MV
40 V 0,01 V v. M. DC 1100 V 40 ...
400 V 0,1 V + 5 Digits) ca. 10 MV AC 800 V 450 Hz
600 V 1V 5(1,5% v.M.+5D)


Zusätzlicher Crestfaktorfehler bei nichtsinusförmigen Signalen
(nur UNITEST Stromzange CHB 37):
Crestfaktor Zusätzlicher Fehler (in % v.M.)
>1- 3 0,5 %
3- 5 1%
5 - 10 6%

Frequenz (Hz) (Spannungsbereich):
Meßbereich Auflösung Genauigkeit Empfindlichkeit Überlastschutz
99,99 Hz 0,01 Hz
999,9 Hz 0,1 Hz 5 (0,1 % 100 mV 600 V eff
9,999 kHz 0,001 kHz v. M.
99,99 kHz 0,01 kHz + 2 Digits)
800 kHz 0,1 kHz 1V

Frequenz (Hz) (Strombereich):
Meßbereich Auflösung Genauigkeit Empfindlichkeit Überlastschutz
100 Hz 0,01 Hz 5(0,5 % v.M. 5 A 1100 A
1 kHz 0,1 Hz + 5 Digits)

15
Widerstand:
Meßbereich Auflösung Genauigkeit Leelaufspannung Überlastschutz
400 V 0,1 V 5(1,5%v.M+5D)
4 kV 0,001 kV
40 kV 0,01 kV 5 (1,5% v.M. < 0,5 V DC 600 V eff.
400 kV 0,1 kV + 3 Digits)
4 MV 0,001 MV
40 MV 0,01 MV 5(2%v.M+3D)


Durchgangsprüfung:
Meßbereich Signalton Leerlaufspannung Überlastschutz
< 40 V < 0,5 V 600 V eff.

Diodenprüfung:
Meßbereich Auflösung Genauigkeit Überlastschutz
< 0,001 V 5 (1,5% v.M. + 2 Digits) 600 V eff.

Peak-Hold-Funktion (Wechselspannung):
(nur UNITEST Stromzange CHB 37, nur manuelle Bereichswahl)
Meßbereich Auflösung Genauigkeit (50...60 Hz) Eingangsimpedanz Überlastschutz

4V 0,001 V 5(3 % ca. 11 MV
40 V 0,01 V v. M. DC 1100 V
400 V 0,1 V + 10 Digits) ca. 10 MV AC 800 V
600 V 1V

Peak-Hold-Funktion (Wechselstrom):
(nur UNITEST Stromzange CHB 37, nur manuelle Bereichswahl)
Meßbereich Auflösung Genauigkeit (50...60 Hz) Überlastschutz
400 A 0,1 A
5 (3% v.M. +10 Digits) AC 1100 A
1000 A 1A
Ansprechzeit Spitzenwerterkennung: < 100 ms


24 Monate Garantie
UNITEST-Geräte unterliegen einer strengen Qualitätskontrolle.
Sollten während der täglichen Praxis dennoch Fehler in der Funktion
auftreten, gewähren wir eine Garantie von 24 Monaten (nur gültig
mit Rechnung).
Fabrikations- oder Materialfehler werden von uns kostenlos
be-seitigt, sofern das Gerät ohne Fremdeinwirkung und ungeöffnet
an uns zurückgesandt wird. Beschädigungen durch Sturz oder
falsche Handhabung sind vom Garantieanspruch ausgeschlossen.
Treten nach Ablauf der Garantiezeit Funktionsfehler auf, wird unser
Werksservice Ihr Gerät unverzüglich wieder instandsetzen.
Änderungen vorbehalten !
16
®
UNITEST
Instruction Manual CHB 7 Order No. 93470 E
CHB 37 Order No. 93480 E

Clamp Meter CHB 7
Clamp Meter CHB 37
Contents Page
1.0 Introduction / Scope of Supply 18
2.0 Safety 18
3.0 Controls and Connections 20
4.0 Operation 21
4.1 Preparation and safety measures 21
4.2 Current Measurements 22
4.2.1 DC current measurements
(only UNITEST Clamp Meter CHB 37) 22
4.2.2 AC current measurements 22
4.3 Voltage measurements 23
4.3.1 DC voltage measurements 24
4.3.2 AC voltage measurements 24
4.4 Frequency measurements 24
4.5 Resistance measurements 25
4.6 Continuity / Diode tests 26
4.6.1 Continuity testing 26
4.6.2 Testing diodes 26
4.7 True RMS measurements / crest factor
(only UNITEST Clamp Meter CHB 37) 26
4.8 MIN/MAX and peak value measurements 27
5.0 Maintenance 28
5.1 Changing the battery 28
6.0 Technical data 29
Important advice on safety matters, both on the instrument and
in the Instruction Manual:
WARNING ! Warns of a potential danger, observe the advice
given in the Instruction Manual.
DANGER ! Indicates a dangerously high voltage.
Double insulated, protection class II IEC 61140.
Symbol for the marking of electrical and electronic equipment
(WEEE Directive 2002/96/EC).
Conformity symbol, the instrument complies with the valid
directives. It complies with the EMC Directive (89/336/EEC)
and the Low Voltage Directive (73/23/EEC) with their valid
standards.

17
1.0 Introduction / Scope of Supply
The UNITEST CHB 7 and CHB 37 Clamp Meters are universal,
multi-purpose IEC 61010 and EN 61010 electrical measuring
instruments. They comply with the standards and provide a safe
and reliable operation. The clamp meters are a valuable tool for all
sorts of measurements in both trade and industry. The UNITEST
Clamp Meter CHB 37 can, in addition, be used to measure true
RMS values; this is particularly important for currents and voltages
which do not conform to a true sine-wave.
· True RMS measurements (only UNITEST Clamp Meter CHB 37)
· 33/4 digit liquid-crystal display
· Choice of automatic or manual range selection for current,
resistance and frequency measurements
· Clamp opening 46 mm
· Switches off automatically
· Integral memory for readings
· Evaluates MIN / MAX values
· Zero-Setting / relative value function
The UNITEST Clamp Meter CHB 7, and Clamp Meter CHB 37 are
supplied complete with leads. After unpacking, check that the
instrument is complete, and that all accessories are present.

Scope of supply:

1 pc. UNITEST Clamp Meter CHB 7 or
UNITEST Clamp Meter CHB 37
2 pc. test leads with probes (red/black)
1 pc. battery 9V IEC 6LR61
1 pc. holster
1 pc. instruction manual

Further accessories, such as test leads, probes, connectors, etc.,
are listed in the main catalogue.




2.0 Safety
The UNITEST Clamp Meter CHB 7, and Clamp Meter CHB 37
have been manufactured and tested to comply with the safety
regulations for electronic measuring equipment and left our works
in a safe condition.

To maintain this condition, the user must observe the safety
instructions contained in this Instruction Manual.
18
The Instruction Manual contains information and advice that
is essential for safe operation and use of the instrument.

Before use study the Instruction Manual carefully, and follow
it in all details, Failure to follow the instructions, or neglecting
warnings can lead to serious injury, and damage to the
instrument.

To avoid electric shock, safety measures must be observed
when working with voltages higher than 120 V (60 V) DC or
50 V (25 V) RMS AC. These are the values of threshold
contact voltages given by DIN VDE. The values in brackets
apply to medical and agricultural applications.

Before each measurement make sure that the test leads and
the instrument are undamaged.

Only handle test leads and probes on the grips provided.
Avoid touching probes under any circumstance.

The relevant safety regulations for electrical plant and
equipment must be observed during all operations.

The instrument must only be used in the specified ranges.

Before opening the instrument, it must be disconnected
from all circuits.

Protect the instrument from prolonged exposure to direct
sunlight.

The instrument may only be used under those conditions
and for those purposes for which it was built. For this
reason, in particular the safety references as well as the
technical data including environmental conditions and the
usage in dry environments must be followed at all times.

When modifying or changing the instrument, the operational
safety can no longer be guaranted.




19
3.0 Controls and Connections
1. Induction coil (clamp)
2. Data hold button, to store results
3. Selector switch, for type of measurement
4. Zero setting / relative value function
5. Manual range selector button
6. Digital display
7. Input socket, for measuring voltage and resistance, and for
continuity and diode testing
8. MIN / MAX value / peak value function (only UNITEST Clamp
Meter CHB 37)
9. Hand-hold area incl. Barrier




20
Battery saving
If the UNITEST CHB 7 or CHB 37 Clamp Meter remains unused
for 30 minutes, it automatically switches off. The " " button
re-activates the instrument. This function prevents the battery
discharging completely if the instrument is accidentally left
switched on. The function is turned off if a button (4,5 or 8) is
pushed during turning the clamp-on ammeter on.

Relative value measurement
The UNITEST CHB 7 and CHB 37 Clamp Meters have a relative
value function. If, during a measurement, the " " button is
pressed, the value of a subsequent measurement is shown relative
to the first value.


4.0 Operation
4.1 Preparation and safety measures

Fitting the battery
Before using the instrument, the battery must be fitted. This is
carried out as follows:

4Separate the instrument from any circuit, and remove the test
leads.

4Open the housing by removing the 3 screws on the rear face.

4Fit a battery (type 9 V IEC 6LR61), taking care that the polarity
is correct. Make sure that no wires are trapped between the 2
halves of the housing, and close it again.

4The instrument is now ready for use.



· The selector switch must be turned to the desired type of
measurement before the probes are connected to the unit under
test (UUT).

· Before switching to a new function, the probes must always be
removed from the UUT.

· Use the instrument only in clean and dry surroundings. Dirt and
moisture reduce the effectiveness of the insulation, with
consequent danger of electric shock, especially when dealing
with high voltages.

· Use the instrument only in the specified ranges.
21
· Before carrying out measurements, verify that the instrument is
functioning properly, for example by testing on a known voltage
or current.

· Make sure that the test leads are undamaged.


4.2 Current Measurements

Never measure currents in uninsulated conductors carrying
more than 250 V !

Only handle test leads and probes on the grips provided.
Avoid touching the probes under any circumstances.


4.2.1 DC current measurements (only UNITEST Clamp Meter
CHB 37)

4Turn selector switch (3) to " A".

4Press the button " ", and make sure that "0.000" is dis-
played.

4The preferred range is set automatically. To change the range
manually press the " " button one or more times, until the
desired range is displayed.

4Open the clamp, and close it round the conductor. Make sure
that the clamp properly encircles the conductor, and that there
is no air gap between the jaws.
For a positive reading, the current must be flowing in the
direction of the arrow on the clamp.
If the display is not visible during measurement, press the
" " button (2) to retain the display. The clamp can then be
removed from the conductor and the stored value read.

4.2.2 AC current measurements

4Turn selector switch (3) to " A".

4The preferred range is set automatically. To change the range
manually press the " " button one or more times, until the
desired range is displayed.

4Open the clamp, and close it round the conductor. Make sure
that the clamp properly encircles the conductor, and that there
is no air gap between the jaws.
If the display is not visible during measurement, press the
" " button (2) to retain the display. The clamp can then be
removed from the conductor and the stored value read.
22
Correct current measurement




The measurement is not correct, the reading will be zero,
because the sum of all currents is zero (Kirchhoff's 1st. Law).
However, with this circuit and a sensitive clamp meter (for example,
the UNITEST Leakage Current Clamp Meter CHB 3, Order No.
93481), the leakage current of a machine can be measured.



4.3 Voltage measurements

Do not connect more than 600 V AC or 600 V DC to the
input sockets. Exceeding these values can endanger the
operator, and may result in damage to the instrument.

Before switching to a new function, disconnect the probes
from the UUT.


23
Only handle test leads and probes on the grips provided. Avoid
touching the probes under any circumstances.


4.3.1 DC voltage measurements

4Turn selector switch (3) to " ".

4Plug the black test lead into the "COM" socket and the red lead
into the "+" socket.

4Connect the probes to the UUT and read the display.

4The optimum range is set automatically.
To change the range manually press the " " button one or
more times, until the desired range is displayed.

If the display is not visible during measurement, press the
" " button (2) to retain the display. The probes can then
be removed from the conductor and the stored value read.


4.3.2 AC voltage measurements

4Turn selector switch (3) to " ".

4Plug the black test lead into the "COM" socket and the red lead
into the "+" socket.

4Connect the probes to the UUT and read the display.

4The optimum range is set automatically.
To change the range manually press the " " button one or
more times, until the desired range is displayed.

If the display is not visible during measurement, press the
" " button (2) to retain the display. The probes can then
be removed from the conductor and the stored value read.


4.4 Frequency measurements

Never measure currents in uninsulated conductors carrying
more than 250 V !

Do not connect more than 600 V AC or 600 V DC to the input
sockets. Exceeding these values can endanger the operator,
and may result in damage to the instrument.
24
Before switching to a new function, disconnect probes from
the UUT.

Only handle test leads and probes on the grips provided. Avoid
touching the probes under any circumstances.

With the UNITEST Clamp Meter you can measure frequency in both
the current and voltage modes.

4Turn selector switch (3) to "Hz".

4Measurement in current mode: open the clamp, and close it
round the conductor. Make sure that the clamp properly encircles
the conductor, and that there is no air gap between the jaws.
Measurement in voltage mode: plug the black test lead into the
"COM" socket and the red lead into the "+" socket.
Connect the probes to the UUT and read the display.

4To select the input sensitivity press the " " button.

If the display is not visible during measurement, press the
" " button (2) to retain the display. The clamp can then be
removed from the conductor and the stored value read.



4.5 Resistance measurements

Disconnect the UUT from all sources of supply and check that
it is at zero voltage.

4Turn selector switch (3) to "V".

4Plug the black test lead into the "COM" socket and the red lead
into the "+" socket.

4Connect the probes to the UUT and read the display.

4The optimum range is set automatically.
To change the range manually press the " " button one or
more times, until the desired range is displayed.

If the display is not visible during measurement, press the
" " button (2) to retain the display. The probes can then be
removed from the conductor and the stored value read.




25
4.6 Continuity / Diode tests

Disconnect the UUT from all sources of supply and check that
it is at zero voltage

Only for UNITEST Clamp Meter CHB 37:
the " " button can be used to switch between acoustic continuity
testing " " and diode testing " ".


4.6.1 Continuity testing

4Turn selector switch (3) to " + ".
(for the UNITEST Clamp Meter CHB 7 to " ")

4Press the " " button one or more times, until the " "
symbol appears in the LC-display.

4Plug the black test lead into the "COM" socket and the red lead
into the "+" socket.
4Connect the probes to the UUT.

A "beep" sounds if the resistance is less than 40 V.


4.6.2 Testing diodes

4Turn selector switch (3) to " + ".
(for the UNITEST Clamp Meter CHB 7 to " ")

4Press the " ". button one or more times, until the " "
symbol appears in the LC-display

4Plug the black test lead into the "COM" socket and the red lead
into the "+" socket.

4Connect the red probe to the anode of the diode and the black
probe to the cathode. If the diode is OK the forward voltage is
displayed.


4.7 True RMS measurements / Crest factor
(only UNITEST Clamp Meter CHB 37)

True RMS measurements:
Commonly available clamp meters give an average value, and are
therefore only suitable for measuring DC, and pure sine-wave AC
currents and voltages. If the AC current or voltage is not a true
sine-wave, for example due to distortion from a phase controller,
then true RMS measurements must be made ­ with the UNITEST
Clamp Meter CHB 37, they can be.
26
Table 1, below, shows a comparison of measurements made with
the UNITEST Clamp Meter CHB 37 and those made with
conventional clamp meters that have average and peak value
functions:


Wave form


RMS value


Rectified value
Display UNITEST
Clamp Meter
CHB 7
Deviation
Display UNITEST
Clamp Meter
CHB 37
Deviation




Crest factor:
The crest factor is the ratio of the peak value to the RMS value of
a signal. This is important for RMS measurements (UNITEST
Clamp Meter CHB 37).Although the measured value may lie
within the chosen range, if the peak value of the signal is too high,
the UNITEST Clamp Meter CHB 37 may be overmodulated and
give false readings.


Wave form

Crest factor
Greek letter Xi

Deviation UNITEST
Clamp Meter CHB 37*


* more precise details of crest factor error are given in Section 6.0, Technical Data




4.8 MIN/MAX and peak value measurements

The MIN/MAX button can be used to find either the largest or the
smallest value of a series of measurements. Pressing the MIN/MAX
button activates first the MIN mode, so that the smallest value is
selected. Pressing it a second time changes to MAX mode, for the
largest value. Pressing the button a third time returns the instrument
to normal operation.

In the case of the UNITEST Clamp Meter CHB 37, you can find
peak values while making measurements of AC current or voltage
­ simply select MAX mode, and start measuring. For example, a
typical application is finding the starting current of an AC motor.
27
5.0 Maintenance
Provided it is used in accordance with the Instruction Manual, the
instrument needs no special maintenance. If it should become
soiled in the course of daily use, it may be cleaned with a damp
cloth and a little mild household detergent.

Never use aggressive cleaners, or solvents.

To maintain accuracy, the instrument must be regularly calibrated
by our Service Department. We recommend annual calibration.



5.1 Changing the battery

If the symbol " " appears in the upper left corner of the dis-
play, the battery must be changed.

This is carried out as follows:

4Separate the UNITEST Clamp Meter CHB 7 or UNITEST Clamp
Meter CHB 37 from any circuit, and remove the test leads.

4Switch the instrument off.

4Open the housing by removing the 3 screws on the rear face.

4Remove the old battery.

4Fit a new battery (type 9 V 6LR61), taking care that the polarity
is correct. Make sure that no wires are trapped between the 2
halves of the housing, and close it again.

4The instrument is now ready for further use.

Please think of our environment when you dispose of your used
batteries. They belong in a rubbish dump or a retuse collection
place for hazardous waste.

Please, comply with the appropriate regulations concerning
the return, recycling and disposal of used batteries and
accumulators.

If the instrument is likely to remain unused for a long period,
the battery must be removed. If a battery should leak inside
the housing, return the instrument to our works for cleaning
and checking.


28
6.0 Technical data
(BEHA reserves the right to make changes)

Display: 33/4digit LC-display. Shows also func-
tions and symbols
Bargraph display: 40 segments
Range selection: automatic or manual
Polarity display: automatic, "-"-sign for negative inputs
Display for range »4« blinks in the display, in addition a
exceeded: continuous warning tone sounds
Rate of measurement: 20 per second for bar display,
2 per second for digital display
Max. conductor dia.: approx. 46 mm
Overvoltage class: CAT III, 600 V
Pollution degree: 2
Height above MSL.: up to 2000 m
Battery indicator: " " displayed when battery
discharged
Battery life: approx. 100 h for
UNITEST Clamp Meter CHB 37,
approx. 300 h for
UNITEST Clamp Meter CHB 7
Power supply: battery 9 V IEC 6LR61 (alkaline)
Auto-Power-Off: switches off after 30 min.
Operating temperature: 0° C to 50° C
Storage temperature: -10° C to 60° C
Humidity: below 70 % r.h.
Dimensions: 239 x 66 x 34 mm
Weight: approx. 365 g


DC current:
Range Resolution Accuracy Overload protection
400 A 0,1 A 5 (2,5% rdg + 5 Digits) 1100 A
1000 A 1A


AC current
(only UNITEST Clamp Meter CHB 37 crest factor 1 ... 10):
Range Resolution Accuracy Overload protection Frequency
400 A 0,1 A 5 (2,5% rdg 1100 A 40 ... 450 Hz
1000 A 1A + 10 Digits)

29
DC voltage:
Range Resolution Accuracy Input Impedance Overload protection

400 mV 0,1 mV > 1000 MV
4V 0,001 V 5 (1 % approx. 11 MV DC 1100 V
40 V 0,01 V rdg AC 800 V
400 V 0,1 V + 2 Digits) approx. 10 MV
600 V 1V


AC voltage:
Range Resolution Accuracy Input Impedance Overload protection Frequency

4V 0,001 V 5(1 % app. 11 MV
40 V 0,01 V rdg DC 1100 V 40 ...
400 V 0,1 V + 2 Digits) app. 10 MV AC 800 V 450 Hz
600 V 1V 5(1,5%rdg+5D)




Additional crest factor error for signals that deviate from a true
sine-wave (only UNITEST Clamp Meter CHB 37):
Crest factor additional error (in % of average value)
>1- 3 0,5 %
3- 5 1%
5 - 10 6%


Frequency (Hz) (Voltage range):
Range Resolution Accuracy Sensitivity Overload protection

99,99 Hz 0,01 Hz
999,9 Hz 0,1 Hz 5 (0,1 % 100 mV DC 1100 V
9,999 kHz 0,001 kHz rdg AC 800 V
99,99 kHz 0,01 kHz + 2 Digits)
800 kHz 0,1 Hz 1V


Frequency (Hz) (Current range):
Range Resolution Accuracy Sensitivity Overload protection

100 Hz 0,01 Hz 5(0,5 % rdg 5A 1100 A
1 kHz 0,1 Hz + 5 Digits)




30
Resistance:
Range Resolution Accuracy Open circuit voltage Overload protection

400 V 0,1 V 5(1,5%rdg+5D)
4 kV 0,001 kV
40 kV 0,01 kV 5 (1,5% rdg < 0,5 V DC 600 V rms
400 kV 0,1 kV + 3 Digits)
4 MV 0,001 MV
40 MV 0,01 MV 5(2%rdg+3D)

Continuity test:
Range Resolution Accuracy Overload protection
< 40 V < 0,5 V 600 V rms

Diode test:
Range Resolution Accuracy Overload protection
0,001 V 5 (1,5% rdg + 2 Digits) 600 V rms

Peak hold function (AC-Voltage):
(only UNITEST Clamp Meter CHB 37, only manual range selection)
Range Resolution Accuracy (50...60 Hz) Input Impedance Overload protection

4V 0,001 V 5(3 % app. 11 MV
40 V 0,01 V rdg DC 1100 V
400 V 0,1 V + 10 Digits) app. 10 MV AC 800 V
600 V 1V

Peak hold function (AC-Current):
(only UNITEST Clamp Meter CHB 37, only manual range selection)
Range Resolution Accuracy (50...60 Hz) Overload protection
400 A 0,1 A 5 (3% rdg +10 Digits) AC 1100 A
1000 A 1A
Reaction time for peak value: < 100 ms


Warranty 24 months' warranty
UNITEST instrumtens are subject to stringent quality controls. If, in
the course of normal daily use, a fault should occur, we provide 24
months' guarantee (only valid with invoice). Faults in manufacture
and materials will be rectified by us free of charge, provided the
instrument has not been tampered with, and is returned to us
unopened. Damage due to dropping, abuse or misuse is not covered
by the guarantee. Our Service Department will repair any faults that
occur outside the guarantee period. This Instruction Manual has
been prepared with great care. No liability is accepted for the
correctness and completeness of the data, illustrations, and
drawings it contains.
BEHA reserves the right to make changes.
31
®
UNITEST
Mode d'emploi CHB 7 Order No. 93470 F
CHB 37 Order No. 93480 F
Pince ampèremétrique CHB 7
Pince ampèremétrique CHB 37
Sommaire Page
1.0 Introduction / étendue de la livraison 33
2.0 Mesures de sécurité 33
3.0 Eléments de commande et raccordements 35
4.0 Exécution des mesures 36
4.1 Préparation et mesures de sécurité 36
4.2 Exécution des mesures d'intensités 37
4.2.1 Mesures d'intensités de courants continus (CHB 37) 37
4.2.2 Mesures d'intensités de courants alternatifs 37
4.3 Exécution des mesures de tensions 38
4.3.1 Mesures de tensions de courants continus 39
4.3.2 Mesures de tensions de courants alternatifs 39
4.4 Exécution des mesures de fréquences 39
4.5 Exécution des mesures de résistances 40
4.6 Exécution des contrôles de continuité /
contrôles de diodes 41
4.6.1 Contrôles de continuité 41
4.6.2 Contrôles de diodes 41
4.7 Mesures de valeurs efficaces réelles (True RMS) /
facteurs de crête
(Pince ampèremétrique UNITEST CHB 37 uniquement) 41
4.8 Mesures de valeurs MIN/MAX / valeurs de crête 42
5.0 Entretien 43
5.1 Remplacement de la pile 43
6.0 Caractéristiques techniques 44

Informations mentionnées sur l'appareil et dans le mode d'emploi:
ATTENTION !
Mise en garde contre une zone dangereuse, respecter les
instructions du mode d'emploi.
DANGER ! Tension dangereuse.
Isolement entier double ou renforcé, classe II IEC 61140.
Symbole pour le marquage des équipements électriques et
électroniques (DEEE Directive 2002/96/CE).
Symbole de conformité, certifie le respect des directives en
vigueur. L'appareil correspond à la Directive 89/336/CEE. La
Directive de basse tension (73/23/CEE) est également
respectée.
32
1.0 Introduction / étendue de la livraison
Les pinces ampèremétriques UNITEST CHB 7 et UNITEST CHB
37 sont des appareils de mesure universels et multifonctionnels.
Leur construction conforme aux normes garantit des mesures
fiables en toute sécurité. Les pinces ampèremétriques constituent
des auxiliaires précieux pour effectuer toutes les mesures stan-
dard de courants dans le secteur industriel ou artisanal. La pince
ampèremétrique UNITEST CHB 37 permet de plus de mesurer
les valeurs efficaces réeles (True RMS), atout important avant tout
pour la mesure d'intendités et de tensions non sinusoïdales.

· Mesures de valeurs efficaces réelles (True RMS)
(Pince ampèremétrique CHB 37 uniquement)
· Affichage à cristaux liquides 3200 points avec bargraphe
· Sélection automatique ou manuelle des plages de mesure pour
mesures d'intensités, tensions, résistances et frequences
· Ouverture de la pince 46 mm
· Fonction de coupure automatique d'alimentation
· Mémorisation des valeurs mesurées
· Fonction valeur MIN/MAX
· Compensation à zéro pour / fonction relative
Les pinces ampèremétriques UNITEST CHB 7 et UNITEST CHB
37 sont livrées complètes avec les câbles de mesure. Au déballage,
vérifier que l'appareil et ses accessoires sont complets.
Etendue de la livraison:
1 Pince ampèremétrique UNITEST CHB 7 ou
Pince ampèremétrique UNITEST CHB 37
2 Câble de mesure avec pointes de touche (rouge, noir)
1 Pile 9 V IEC 6LR61
1 Etui
1 Mode d'emploi
Autres accessoires tels que câbles de mesure, pointes de touche,
bornes, etc., voir le catalogue général UNITEST.


2.0 Mesures de sécurité
Les pinces ampèremétriques UNITEST CHB 7, et UNITEST CHB
37 ont été construites et contrôlées conformément aux prescriptions
de sécurité des normes EN 61010, IEC 61010 et sont sorties de
notre usine en parfait état de sécurité.
L'utilisateur est tenu de respecter les consignes de sécurité conte-
nues dans cette notice pour maintenir les appareils dans cet état.

Ce mode d'emploi contient des conseils d'utilisation et des
consignes de sécurité destinés à assurer la manipulation des
appareils en toute sécurité.

33
Lire attentivement ce mode d'emploi et en observer toutes les
instructions avant toute utilisation de l'appareil. Le non-respect
de ces instructions pourrait provoquer des accidents corporels
graves, voire mortels, ou détériorer l'appareil.

Afin d'éviter tout choc électrique, respectez les mesures de
sécurité suivantes lorsque vous travaillez sur des tensions
supérieures à 120 V (60 V) DC ou 50 V (25 V) eff AC. Selon
les normes DIN VDE, ces tensions constituent des valeurs
limites de sécurité. (Les valeurs entre parenthèses concernent
les établissements hospi-taliers ou agricoles par ex.).

Avant toute utilisation, s'assurer du parfait état des câbles de
mesure et des appareils.

Ne manipuler les câbles de mesure avec pointes de touche
que par les poignées prévues à cet effet. Dans tous les cas,
éviter de toucher les pointes de touche.

Lors de toute opération, respecter les prescriptions nationales
concernant la prévention des acccidents dus aux installations
et matériels électriques.

N'utiliser les appareils que dans les plages de mesure
indiquées.

Avant d'ouvrir les appareils pour premplacer la pile, s'assurer
qu'ils soient déconnectés de tout circuit de mesure.

Afin d'assurer le bon fonctionnement et la longévité des
appareils, éviter de les exposer à la chaleur (au soleil
notamment).

L'appareil n'est à utiliser que sous des conditions et pour des fins
ayant été à l'origine de sa conception. Pour cette raison, les
références de sécurité, les donnés techniques comprenant les
conditions d'environnement et l'utilisation dans des environnements
secondes sont à respecter en particulier.

La sécurité d'opération n'est plus assurée lorsque l'appareil
a été changé ou modifié.




34
3.0 Eléments de commande et raccordements
1. Transducteur (pince)
2. Touche HOLD de mémorisation des valeurs mesurées
3. Sélecteur de type de mesure
4. Compensation à zéro / fonctin relative
5. Sélection manuelle de la plage de mesure
6. Affichage numérique
7. Bornes d'entrée pour mesures de tensions, résistances,
frequences et contrôles de
continuité et de diodes
8. Fonction valeurs
MIN / MAX /
valeurs de crête
(Pince ampère-
métrique
UNITEST
CHB 37
uniquement)
9. Secteur de
prise avec
des colliers
de protection
de prise




35
Coupture automatique de l'alimentation
Les pinces ampèremétriques UNITEST CHB 7 et UNITEST CHB
37 disposent d'une fonction de coupure automatique de l'alimen-
tation. Si aucune fonction n'a été activée pendant 30 mn,
l'alimentation des appareils est automatiquement coupée. La touche
" " permet de réactiver les appareils. La fonction de coupure
automatique d'alimentation permet d'eviter que la pile ne se
décharge trop rapidement lorsque l`on a laissé les appareils sous
tension par inadvertance. Fonction de compure automatique est
déactivé par presser une boutton (4,5 ou 8) durant le sélecteur de
type de mesure actionner la pince.

Mesures de valeurs relatives
Les pinces ampèremétriques UNITEST CHB 7 et UNITEST CHB
37 disposent d'une fonction valeur relative. Cette fonction permet
de prendre une valeur instantanée pour zéro et de déterminer la
valeur relative de chaque mesure par rapport à cette valeur.


4.0 Exécution des mesures
4.1 Préparation et mesures de sécurité

Mise en place de la pile:
Avant de mettre l'appareil en service, il est nécessaire de mettre la
pile en place. Pour cela, procéder de la façon suivante:

4Déconnecter l'appareil du circuit de mesure et retirer tous les
câbles de mesure.

4Ouvrir le boîtier en dévissant le 3 vis situées au dos de l'appareil.

4Mettre la pile, type 9 V IEC 6LR61, en place en respectant la
polarité et refermer le boîtier. Faire attention à ne pas coincer de
câbles entre les deux parties du boîtier.

4L'appareil est opérationnel, vous pouvez commencer les
mesures.


· Positionner le sélecteur de type de mesure sur la fonction
désirée avant de connnecter les pointes de touche aux points de
mesure.
· Avant de changer de fonction ou de plage de mesure, toujours
déconnecter les câbles de mesure des points de mesure
· N'utiliser les appareils que dans des milieux et secs.
La saleté et l'humidité diminuent les résistances d'isolement et
peuvent, en particulier lorsque les tensions sont élevées,
provoquer des chocs électriques.
· N'utiliser les appareils que dans les plages de mesure indiquées.
36
· Avant toute utilisation, vérifier le bon fonctionnement des appareils
(sur une source de courant connue par ex.).
· Veiller à ce que les câbles de mesure soient toujours en parfait état.

4.2 Mesure d'intensités
Ne jamais mesurer des courants dans des circuits de mesure
non isolés d'une tension nominale supérieure à 250 V !
Ne manipuler les câbles de mesure avec pointes de touche
que par les poignées prévues à cet effet. Dans tous les cas,
éviter de toucher les pointes de touche.

4.2.1 Mesures d'intensités de courants continus
(Pince ampèremetrique UNITEST CHB 37 uniquement)
4Positionner le sélecteur de type de mesure (3) sur le symbole
" A".
4Appuyer sur la touche " " (4). Vérifier que l'écran affiche
bien "000.0".
4La plage de mesure la mieux adaptée est sélectionnée. La
sélection manuelle de la plage de mesure s'effectue en appuyant,
éventuellement plusieurs fois, sur la touche " " jusqu'à ce
que la plage désirée soit sélectionnée.
4Ouvrir la pince et la refermer sur le conducteur de courant.
Veiller à ce que la pince enserre complètement le conducteur
de courant sans discontinuité.
Pour obtenir un affichage positif, il est nécessaire que le courant
circule dans le sens de la flèche figurant sur la pince.
Si aucune valeur ne s'affiche au cours de la mesure, la valeur
mesurée peut être mémorisée à l'aide de la touche (2) " ".
Débrancher ensuite la pince du point de mesure et relever la
valeur mémorisée sur l'écran.

4.2.2 Mesures d'intensités de courants alternatifs
4Positionnner le sélecteuer de type de mesure (3) sur le symbole
" A"
4La plage de mesure la mieux adaptée est sélectionée. La sélection
manuelle de la plage de mesure s'effectue en appuyant,
éventuellement plusieurs fois, sur la touche " " jusqu'à ce
que la plage désirée soit sélectionnée.
4Ouvrir la pince et la refermer sur le conducteur de courant.
Veiller à ce que la pince enserre complètement le conducteur
de courant sans discontinuité.
Si aucune valeur ne s'affiche au cours de la mesure, la valeur
mesurée peut être mémorisée l'aide de la touche (2) " ".
Débrancher ensuite la pince du point de mesure et relever la
valeur mémorisée sur l'écran.
37
Mesure d'intensité correcte.




Mesure d'intensité incorrecte, l'écran affiche zéro.
Car d'après la première règle de Kirchhoff la somme de toutes les
intensités est égale à zéro. Cependant, il est possible de mesure
d'après cette règle de mesure le courant de décharge de l'utilisateur
à l'aide d'une pince ampèremétrique suffisamment sensible (telle
que la pince ampèremétrique d'intensité de fuite UNITEST CHB 3
réf. art.: 93481, par ex).


4.3 Exécution des mesures de tension

Ne jamais appliquer de tensions supérieures à 600 V AC ou
600 V DC aux bornes d'entrée. Des tensions supérieures à
ces valeurs risqueraient de détériorer l'appareil et de mettre
l'opérateur en danger.

Déconnecter les pointes de touche des points de mesure
avant de sélectionner un autre type de mesure.


38
Ne manipuler les câbles de mesure avec pintes de touche
que par les poignées prévues à cet effet. Dans tous les cas,
éviter de toucher les pointes de touche.

4.3.1 Mesures de tensions de courants continus
4Positionner le sélecteur de type de mesure (3) sur le symbole
" ".
4Connecter le câble de mesure noir à la borne "COM" et le rouge
à la borne "+"..
4Connecter les pointes de touche aux points de mesure. Relever
la valeur affichée sur l'écran.
4La plage de mesure la mieux adaptée est sélectionnée.
La sélection manuelle de la plage de mesure s'effectue en
appuyant, éventuellement plusieurs fois, sur la touche " "
jusqu'à ce que la plage désirée soit sélectionnée.
Si aucune valeur ne s'affiche au cours de la mesure, la valeur
mesurée peut être mémorisée à l'aide de la touche (2) " ".
Débrancher ensuite la pince du point de mesure et relever la
valeur mémorisée sur l'écran.

4.3.2 Mesures de tensions de courants alternatifs
4Positionner le sélecteur de type de mesure (3) sur le symbole
" ".
4Connecter le câble de mesure noir à la borne "COM" et le rouge
à la borne "+".
4Connecter les pointes de touche aux points de mesure. Relever
la valeur affichée sur l'écran.
4La plage de mesure la mieux adaptée est sélectionée.
La sélection manuelle de la plage de mesure s'effectue en
appuyant, éventuellement plusieurs fois, sur la touche " "
jusqu'à ce que la plage désirée soit sélectionnée.
Si aucune valeur ne s'effiche ne s'affiche au cours de la mesure, la
valeur mesurée peut être mémorisée à l'aide de la touche (2)
" ". Débrancher ensuite la pince du point de mesure et
relever la valeur mémorisée sur l'écran.

4.4 Exécution des mesures de fréquences
Ne jamais mesurer de courants dans des circuits de mesure
non isolés d'une tension nominale supérieure à 250 V !
Ne jamais appliquer de tensions supérieures à 600 V AC ou
600 V DC aux bornes