Text preview for : DVP320_SW_upgrade.pdf part of Philips DVP320 SW upgrade Philips Symptom Cure 2006 References DVP320_SW_upgrade.pdf



Back to : DVP320_SW_upgrade.pdf | Home

A. Preparation to upgrade firmware:
1. Unzip the zip-archive attached to this Symptom/Cure
2. Start the CD Burning software and create a new CD project (data disc) with the following setting:
File system: ISO9660
Format: MODE 1: CDROM
Recording mode: SINGLE SESSION (TRACK-AT-ONCE), FINALIZED CD
3. Place the content of the zip-archive (2 files) into the root directory of the new CD project.
4. Burn the data onto a blank CDR

Note: ISO9660 is mandatory, UDF discs are not supported !
The final CDROM must not contain any other data except the file from the zip-archive.


B. Procedure to apply the firmware upgrade:
1. Power up the set and open tray.
2. Insert the prepared Upgrade CDROM and close the tray.
3. The upgrading operation will start automatically
4. The Play_LED will blink.
5. The upgrade process takes less than 2 minutes
6. Remove the upgrade disc when the Play_LED stops blinking.
Note: Do not press any buttons or interrupt the mains supply during the upgrading process,
otherwise the set may become defective.


C. How to read out the firmware version to confirm upgrading
1. Power up the set and open tray.
2. Press on the Remote control.
3. The TV screen will shows:

GAP542PH-030812-320-171U
SERVO:001FC74 REG:1

where : GAP542PH-030812 = application software version
320-171U = set-up configuration of a type number eg. DVP320/17
SERVO:001FC74 = servo software version
REG:1 = region code