Found: 76
Philips
ANUBIS-S
Powers supply output voltages for the different sc
Powers supply output voltages for the different screensizes for ANUBIS-S AA/BB/CC/DD ------------------------ For adjusting the power supply output voltage (via R3512) following survey gives an overview of the values for the different screensizes of all c
14-09-04
Philips
ANUBIS-S
Protection of part of EEPROM
Protection of part of EEPROM ---------------------------- For all versions: For software number 1 (6k no TXT) and software number 2 (8k TXT) ADDRESS 255 should be filled with DATA 232 after replacing the EEPROM. This to make sure the right part of the EE
14-09-04
Philips
ANUBIS-S
Purity problem (patches on screen)
Change item 3501 from 18 Ohm PTC to 9 Ohm PTC Service code 9 Ohm PTC is 4822 116 40277
14-09-04
Philips
ANUBIS-S
Purity problems 20" versions
Replace PTC R3501 by a 9 ohm version. Code number 4822 116 40277.
14-09-04
Philips
ANUBIS-S
Service manual correction LATAM service manual
Service manual correction LATAM service manual ---------------------------------------------- In service manual 4822 727 19719 the following components are changed at production start only TRINORMA sets: C2272 becomes 10nF (4822 126 12642) C2273 becomes
14-09-04
Philips
ANUBIS-S
Set is switched in protection (switched in to standby)
Check if pin 16 of uP IC7600 is continiously "low". If so the set is in protection. Check D6618 in the control part and replace if necessary by BZX79-B9V1 (4822 130 30862) REMARKS : Introduced in production week 9408
14-09-04
Philips
ANUBIS-S
Snowy picture
Add a diode 1N4148 (4822 130 30621) in series with item 5002. Connect the anode at the L5002 side and the cathode at the junction of C2002 and pin 12 of the tuner REMARKS : Introduced in production week 9410 The diode ensures a correct supply v
14-09-04
Philips
ANUBIS-S
Sound distorted in theatre mode if volume is set from mid to highlevel
Modify following components on incredible sound panel. R3205 and R3405 into 1k5 - 4822 051 11502 C2302 and C2305 into 100nF - 5322 121 42386 R3305 and R3302 into 560E - 4822 050 15601 R3500 into 220E - 4822 052 10221 R3300 and R3303 into 1k2 - 4822 050 11
14-09-04
Philips
ANUBIS-S
Sound distortion at theatre mode
To solve the problem make next changes: On incredible sound panel Pos. number Change to 1K2 4822 116 52207 3205,3405,3300,3303 Change to 100 nF 5322 121 42386 2302,2305 Change to 560E 4822 116 52226
14-09-04
Philips
ANUBIS-S
Sound in picture
Replace L5014 by 0.68uH (4822 157 63065) REMARKS : Introduced in production week 9319
14-09-04
Philips
ANUBIS-S
Sound in picture (interference in picture)
In case of sound in picture interference it is recommended to: Place C2170 by 2n2 20% 50V 4822 126 12639 REMARKS : Introduced in production week 9407
14-09-04
Philips
ANUBIS-S
Sound plop at switching on/off spatial feature
It is recommended to solder a capacitor of 10uF 50V 20% 4822 124 40428 accross TS7140 (+ of capacitor at collector of TS7140 and - of capacitor at ground e.g. at jumper 9056)
14-09-04
Philips
ANUBIS-S
Spook on picture in all versions.
Replace IC7218 (voltage stabalizer of IC7225) by L7808CP (5322 209 86283). REMARKS : Introduced in production week 9333 (in Spanish service manual this is already updated in the spare parts list)
14-09-04
Philips
ANUBIS-S
Vertical foldback lines
Replace R3325 on the CRT panel by 3k3 (4822 116 52269) Replace R3407 in the frame part of 20/21" by 33k (4822 051 10333) REMARKS : Introduced in production week 9318
14-09-04
Philips
ANUBIS-S
Vertical shift alignment not enough
It is recommended to replace in the frame part of the 25" Anubis S BB: R3401 to 680R (4822 116 52228) nearby vertical shift potentiometer R3408. Realign the vertical shift after replacement. REMARKS : Introduced in production week 9405
14-09-04
Philips
ANUBIS-S
Video in sound at weak signed in PAL/SECAM sets
Modify in the BIMOS sound part: Replace C2102 by 4n7 (4822 126 12641) Replace C2112 by 560p (4822 126 13097) Replace C2119 by 270p (4822 126 13096) Replace C5112 by 15uH (4822 157 52224) REMARKS : Introduced in production week 9340
14-09-04