File name CPD-520GS.pdfCPD-520GS/520GST/520GST9
SERVICE MANUAL
REVISED
CPD-520GS
US Model Canadian Model
Chassis No. SCC-L04N-A CPD-520GST
AEP Model UK Model
Chassis No. SCC-L04N-A CPD-520GST9
AEP Model
Chassis No. SCC-L04N-A
N3 CHASSIS
SPECIFICATIONS
Picture tube 0.25 0.27 mm aperture grille pitch 21 inches measured diagonally 90-degree deflection Approx. 403.8 × 302.2 mm (w/h) (16 × 12 inches) 19.8" viewing image Horizontal: Max. 1600 dots Vertical: Max. 1200 lines Approx. 388 × 291 mm (w/h) (15 3/8 × 11 1/2 inches) or Approx. 364 × 291 mm (w/h) (14 3/8 × 11 1/2 inches) Horizontal: 30 to 96 kHz Vertical: 48 to 160 Hz 100 to 240 V, 50 60 Hz, 2.0 1.0 A Max. 160 W 498 × 505 × 474 mm (w/h/d) (19 5/8 × 20 × 18 3/4 inches) Approx. 31 kg (68 lb 5 oz) See page 6 Viewable image size
Resolution Standard image area
Deflection frequency AC input voltage/current Power consumption Dimensions Mass Supplied accessories
Design and specifications are subject to change without notice.
TRINITRON COLOR COMPUTER DISPLAY
®
MICROFILM
CPD-520GS/520GST/520GST9
SAFETY CHECK-OUT (US Model only)
After correcting the original service problem, perform the following safety checks before releasing the set to the customer: 1. Check the area of your repair for unsoldered or poorly-soldered connections. Check the entire board surface for solder splashes and bridges. 2. Check the interboard wiring to ensure that no wires are "pinched" or contact high-wattage resistors. 3. Check that all control knobs, shields, covers, ground straps, and mounting hardware have been replaced. Be absolutely certain that you have replaced all the insulators. 4. Look for unauthorized replacement parts, particularly transistors, that were installed during a previous repair. Point them out to the customer and recommend their replacement. 5. Look for parts which, though functioning, show obvious signs of deterioration. Point them out to the customer and recommend their replacement. 6. Check the line cords for cracks and abrasion. Recommend the replacement of any such line cord to the customer. 7. Check the B+ and HV to see if they are specified values. Make sure your instruments are accurate; be suspicious of your HV meter if sets always have low HV. 8. Check the antenna terminals, metal trim, "metallized" knobs, screws, and all other exposed metal parts for AC Leakage. Check leakage as described below.
To Exposed Metal Parts on Set
LEAKAGE TEST
The AC leakage from any exposed metal part to earth ground and from all exposed metal parts to any exposed metal part having a return to chassis, must not exceed 0.5 mA (500 microampers). Leakage current can be measured by any one of three methods. 1. A commercial leakage tester, such as the Simpson 229 or RCA WT-540A. Follow the manufacturers' instructions to use these instruments. 2. A battery-operated AC milliammeter. The Data Precision 245 digital multimeter is suitable for this job. 3. Measuring the voltage drop across a resistor by means of a VOM or battery-opera |