datasheet,schematic,electronic components, service manual,repairs,tv,monitor,service menu,pcb design
Schematics 4 Free
Service manuals, schematics, documentation, programs, electronics, hobby ....


registersend pass
Bulgarian - schematics repairs service manuals SearchBrowseUploadWanted

Now downloading free:JVC GM-P420

JVC GM-P420 free download

TV - Conventional CRT, LCD Projectors, TFT, Plasma, Big Screen, HDTV, Home theater - Service manuals, repair tips

File information:
File name:JVC GM-P420 5parts !.part4.rar
Size:2000 kB
Extension:pdf
Mfg:JVC
Model:GM-P420 🔎 GMP420
Original:
Descr:42'' PLASMA DISPLAY MONITOR
Group:Electronics > Consumer electronics > TV
Uploaded:25-12-2005
User:BZKuki
Multipart: 0  1  2  3  4

Information about the files in archive:
Decompress result:OK
Extracted files:8
File name 51953.pdf

GM-P420PCE GM-P421PCE GM-P420E SERVICE MANUAL 42'' PLASMA DISPLAY MONITOR GM-P420PCE GM-P421PCE GM-P420E BASIC CHASSIS S3 CONTENTS ! ! ! ! ! ! ! ! SPECIFICATIONS 2 OPERATING INSTRUCTIONS(Appendix) 1-1 SAFETY PRECAUTIONS 5 TECHNICAL INFOMATION 6 PRECAUTIONS FOR USE 8 SPECIFIC SERVICE INSTRUCTIONS 11 SERVICE ADJUSTMENTS 35 STANDARD CIRCUIT DIAGRAM(Appendix) 2-1 PARTS LIST 51 SPECIFICATION(Pin assigment / Dimensions) 79 1 CO PYRIGHT © 2002 VICTOR COMPANY OF JAPAN, LTD. No.51953 Apr. 2002 GM-P420PCE GM-P421PCE SPECIFICATIONS Item Model Dimension (W× H× D) × × Mass Type Power requirements Rated input curr ent Effective screen dim ensions Nmber of pixele Pixel pitch Cell pitch Display colours Aspect ratio Au dio po wer output Environment Content GM-P420PCE / GM-P421PCE 103.5c m×64.0cm×8.9cm 32.3kg Plas ma display 230VAC, 50Hz / 60Hz 1.4A (W ) 92.1cm×(H) 51.8cm, (Diagonal) 105.7cm Horizontal 853×Vertical 480 Horizontal 1.08mm×Vertic al 1.08mm Horizontal 0.36mm×Vertic al 1.08mm 16.77million colours (256 colours for eac h of RGB) 16:9 (Wide format) Speak er out : 6 16, 3W+3W(TYP at impedanc e 6 ) Temperature : 040 Relative humidity : 2080% (non-condensing) Pressure : 7001114hPa Temperature : -2060 Relative humidity : 1085%(non-c ondensing) Pressure : 3001114hPa RGB input : D-sub 3-row 15-pin terminal×1 Video s ignal : 0.7V(p-p) / 75 G on s ync : 1V(p-p) / 75 (negative syncy) [ Horizontal sync (HD) ] HD : 0.35V(p-p) / 470(pos itive / negative polarity) [ Composite s ync (Cs) ] Cs : 0.35V(p-p) / 470(pos itive / negative polarity) [ Vertic al sync (VD) ] VD : 15V(p-p) / 470(pos itive / negative polarity) Audio input : Stereo mini jack terminal×1, 500mV(rms) / high impedance RS-232C input : D-sub 9-pin terminal×1 MAKE : Mini DIN 4pin WIRED : Stereo mini jack terminal×2 Use exc lusively for JVC's optional parts Impedance 6 16(L/R) Pin jack terminal×2(L/R), Outout impedance 600 Remote control unit× 1(RM-C576), AA/R6-size dry cell battery×2(for operation check) Remote control cable ×1, Power cord (approx 2.5m) ×3 Storage INPUT/OUTPUT TERMINALS RGB A REMOTE (D-sub 9pin) OPTION SPEAKER OUT AUDIO OUT Accessories Design and specifications are subject to change without notice. MAIN DIFFERENCE OF MODEL Model Connector Inputs VIDEO A VIDEO B COMPONENT / RGB B GM-P420PCE/GM-P421PCE Not available Not available Not available GM-P420E Available Available Available 2 No. 51953 GM-P420E Item Model Dimension (W ×H× D) Mass Type Comp atible VIDEO A, B COMPONENT System Power requirements Rated input curr ent Effective screen dim ensions Nmber of pixele Pixel pitch Cell pitch Disp lay colours Aspect ratio Au dio po wer output Environment Content GM-P420E 103.5c m×64.0cm ×8.9cm 32.3kg Plas ma display NTSC, NTSC4.43, PAL, PAL60, SECAM 480i, 576i, 480p, 720p, 1035i, 1080i(1035i) 230VAC, 50Hz / 60Hz 1.4A (W ) 92.1cm×(H) 51.8cm, (Diagonal) 105.7cm Horizontal 853×Vertical 480 Horizontal 1.08mm ×Vertic al 1.08mm Horizontal 0.36mm×Vertic al 1.
File name 51953b.pdf

GM-P420PCE GM-P421PCE GM-P420E GM-P420PCEG SERVICE MANUAL PLASMA DISPLAY MONITOR GM-P420PCE/A GM-P421PCE/A GM-P420E/A GM-P420PCEG/A Supplementary BASIC CHASSIS S3 The following item for the GM-P420PCE/A, GM-P421PCE/A, GM-P420E/A, model were changed partly from GM-P420PCE, GM-P421PCE, GM-P420E model. Therefore, this service manual describes only the STANDARD CIRCUIT DIAGRAM & PARTS LIST. For details other than those described in this manual, please refer to the GM-P420PCE, GMP421PCE, GM-P420E model service manual (No.51953, April 2002). NOTE: The GM-P420PCEG/A is a model whose colour (gray) is difference from that of the GM-P420PCE. For details other than those described in this manual, please refer to the GM-P420PCE model service manual (No.51953, April 2002). OUTLINE Since the performance of this model has improved, we have issued the SERVICE MANUAL for GM-P420PCE/A, GM-P421PCE/A, GM-P420E/A, GM-P420PCEG/A . CONTENTS ! ! ! ! 1 HOW TO IDENTIFY MODELS 2 TECHNICAL INFORMATION 3 MAIN DIFFERENCE LIST 4 STANDARD CIRCUIT DIAGRAM (Appendix) 2-1 PRINTED WIRING BOARD PARTS LIST 7 COPYRIGHT © 2002 VICTOR COMPANY OF JAPAN, LTD. No.51953B Jul. 2002 GM-P420PCE GM-P421PCE GM-P420E GM-P420PCEG HOW TO IDENTIFY MODELS Model No.GM-P420PCEA, GM-P421PCEA, GM-P420EA or GM-P421PCEGA is indicated on the Rating Label. Original model No. GM-P420PCE GM-P421PCE GM-P420E GM-P420PCEG Indicated GM-P420PCEA GM-P421PCEA GM-P420EA GM-P420PCEGA 2 No. 51953B TECHNICAL INFORMATION This model has newly equipped with the REMOCN THROUGH function. GM-P420PCE GM-P421PCE GM-P420E GM-P420PCEG The REMOCON THROUGH function is a function that is capable of controlling such equipment as a karaoke system connected to the REMOCON THROUGH terminal by receiving the IR (infrared ray) signal at the sensor of the remote controller unit of this model. 1. REMOCON THROUGH output terminal The REMOCON THROUGH terminal and MAKE (mini DIN 4 pin) terminal at the back of the main body share the same terminal. Therefore, it is necessary to change the setup at the SERVICE MENU when the REMOCON THROUGH function is used. For the pin layout at the terminal, the 4 pin will become an output terminal and the 1-3 pins will be GNDs. REMOCON THROUGH OUTPUT TERMINAL Pin No 1 Signal name GND GND GND OUTPUT 2. How to change the setup of the function 1) Enter the SERVICE MENU. 2) Select the CPU BLOCK with the UP() / DOWN() key of the remote control unit. 3) Press the RIGHT ( 5) Press the RIGHT ( 7) 8) 9) 10) ) key of the remote control unit to display the CPU BLOCK. ) key of the remote control unit to display the setup screen for the "SYSTEM CONSTANT". 4) Select the "CE: SYSTEM CONSTANT" with the UP() / DOWN() key of the remote control unit. 6) Display the "CE 5" with the UP() / DOWN() key of the remote control unit. Change the setup value to 001 from 000 with the LEFT( ) / RIGHT ( ) key of the remote control unit. Press the MENU key of the remote control unit to exit from the SERVI
File name 51953bsch.pdf

GM-P420PCE,GM-P421PCE GM-P420E,GM-P420PCEG SP TERMINAL L PWB PATTERN GM-P420PCE,GM-P421PCE GM-P420E,GM-P420PCEG FRONT GM-P420PCE/A,GM-P421PCE/A GM-P420E/A,GM-P420PCEG/A STANDARD CIRCUIT DIAGRAM NOTE ON USING CIRCUIT DIAGRAMS 3 TOHO 01.12.26 CKM0483-B01-1 1.SAFETY The components identified by the symbol and shading are critical for safety. For continued safety replace safety critical components only with manufactures recommended parts. 2 J001 UL MARK 1 L003 L002 L001 2.SPECIFIED VOLTAGE AND WAVEFORM VALUES The voltage and waveform values have been measured under the following conditions. (1)Input signal (2)Setting positions of each knob/button and variable resistor (3)Internal resistance of tester : Colour bar signal Type No indication MM PP MPP MF TF BP TAN (3)Coils No unit L C001 :Ceramic capacitor :Metalized mylar capacitor :Polypropylene capacitor :Metalized polypropylene capacitor :Metalized film capacitor :Thin film capacitor :Bipolar electrolytic capacitor :Tantalum capacitor :[ µ H] :As specified 1 : Original setting position when shipped :DC 20k :H :V :Others /V 20µS/div 5mS/div Sweeping time is specified (4)Oscilloscope sweeping time Others (4)Test point :Test point (5)Connecting method :Only test point display SP TERMINAL R PWB PATTERN :Connector :Receptacle (6)Ground symbol :LIVE side ground :ISOLATED(NEUTRAL) side ground :EARTH ground :DIGITAL ground :Wrapping or soldering FRONT (5)Voltage values :All DC voltage values Since the voltage values of signal circuit vary to some extent according to adjustments, use them as reference values. CKM0484-B01-1 L001 L002 L003 2 J001 UL MARK TOHO 1 01.12.26 3.INDICATION OF PARTS SYMBOL [EXAMPLE] In the PW board :R1209 R209 TEMP. SENSOR PWB PATTERN 5 4 C101 IC101 8 1 3 R 1 C001 4.INDICATIONS ON THE CIRCUIT DIAGRAM (1)Resistors Resistance value No unit K M :[ ] :[K ] :[M ] 5.NOTE FOR REPAIRING SERVICE This model's power circuit is partly different in the GND. The difference of the GND is shown by the LIVE : ( ) side GND and the ISOLATED(NEUTRAL) : ( ) side GND.Therefore, care must be taken for the following points. (1)Do not touch the LIVE side GND or the LIVE side GND and the ISOLATED(NEUTRAL) side GND simultaneously. If the above caution is not respected, an electric shock may be caused. Therefore, make sure that the power cord is surely removed from the receptacle when, for example, the chassis is pulled out. (2)Do not short between the LIVE side GND and ISOLATED(NEUTRAL) side GND or never measure with a measuring apparatus measure with a measuring apparatus ( oscilloscope, etc.) the LIVE side GND and ISOLATED(NEUTRAL) side GND at the same time. If the above precaution is not respected , a fuse or any parts will be broken. Since the circuit diagram is a standard one, the circuit and circuit constants may be subject to change for improvement without any notice. NOTE Due improvement in performance, some part numbers show in the circuit diagram may not agree
File name 51953c.pdf

GM-P420E SERVICE MANUAL PLASMA DISPLAY MONITOR GM-P420E/A Supplementary BASIC CHASSIS S3 GM-P420E/A model changed a performance into Australia turning. Therefore, this service manual describes only the items which differ from those of the previous model service manual. For details other than those described in this manual, please refer to the GM-P420E/A model service manual (No.51953B, Jul. 2002). HOW TO IDENTIFY MODELS Indicated SERIAL No. ××× ×××A0001××× ×××A0135 on the Rating Label. ××× Indicated ×××A0001 to ××× ×××A0135 ××× 1 COPYRIGHT © 2002 VICTOR COMPANY OF JAPAN, LTD. No.51953C Oct. 2002 GM-P420E CHANGED ITEMS CHANGE OF INPUT SIGNAL PREVIOUS INPUT SIGNAL 1080/60i 1035/60i AFTER 1080/50i Not available NOTE: In accordance with the change this time, the HD SIGNAL MODE in the SET UP MENU will not be displayed. As a result, you can not switch the 1080/60i to the 1035/60i. DIFFERENT ITEM USING PW BOARD (Page 4) PWB NAME MAIN PWB PREVIOUS FX-1175A AFTER FX-1182A PRINTED WIRING BOARD PARTS LIST MAIN P.W. BOARD ASS'Y (Page 2735) ! Symbol No. FX-1175A R1540 R1599 C1543 IC1602 AT24C64-GMP420E Parts No. FX-1182A NRSA63J-823X QRE141J-273Y NDC31HJ-271X AT24C64-P420EAU Parts name MG R CR C CAP IC (MEMORY) Description 82k 1/16W J 27k 1/4W 270pF 50V SERVICE J J PACKING PARTS LIST (Refer to the page 76 in the GM-P420E SERVICE MANUAL (No.51953. Apr. 2002) ) ! ! Ref. No. GM-P420E 11 QMPP070-250-K Parts No. GM-P420E/A For AUSTRALIA Parts Name POWER CORD INST SHEET Description For AUSTRALIA ADDITION QMPH030-250-K LCT1323-001A VICTOR COMPANY OF JAPAN, LIMITED HOME AV NETWORK BUSINESS UNIT 12, 3-chome, Moriya-cho, Kanagawa-ku, Yokohama, Kanagawa-prefecture, 221-8528, Japan 4 Printed in Japan 0210 WPC DP205859
File name 51953d.pdf

GM-P420E SERVICE MANUAL PLASMA DISPLAY MONITOR GM-P420E/AU Supplementary BASIC CHASSIS S3 The following item for the GM-P420E/AU model was changed partly from GM-P420E/A model. Therefore, this service manual describes only the items, which differ from those of the GM-P420E/A service manual. For details other than those described in this manual, please refer to the GM-P420E/A model service manual (No.51953B, Jul. 2002). OUTLINE Since this model changed a performance into Australia turning, we have issued the SERVICE MANUAL for GM-P420E/AU. HOW TO IDENTIFY MODELS Indicated model name "GM-P420EAU" on the Rating Label. Indicated GM-P420EAU 1 COPYRIGHT © 2002 VICTOR COMPANY OF JAPAN, LTD. No.51953D Oct. 2002 GM-P420E ADDITION ITEMS ADJUSTMENT Item AD INPUT OFFSET (480i) adjustment Test equipment NTSC signal generator (component output) Oscilloscope Test points TP-PR (IC205 31pin) TP-PB (IC205 53pin) [MAIN PWB] Adjustment locations I(B19) : OUTPUT MODE W(E11) : AD PR OFFSET W(E13) : AD PB OFFSET Adjustment procedure 1. Input the 480i whole black component video signal to the COMPONENT terminal. 2. Connect the oscilloscope to the TP-PR (31 pin of IC 205 - the highest bit). 3. Enter SERVICE MENU, and select the DEVICE INITIAL VALUE. 4. Select the IB:CXA3506R in the DEVICE INITIAL VALUE, and select the I(B19). 5. Change the value of I(B19) in order of 000001000. By Horizontal duration Picture signal duration (A) W(E11) /W(E13) Too low Increase the value 0V 5V doing this adjustment, the internal system in the microcomputer is changed. So you must do this adjustment without fail. 6. Return to SERVICE MENU. 7. Select the WHITE BALANCE BLOCK. 8. Adjust the values W(E11) so that the brightness at the Low (0V) and High (5V) of the digital signal voltage corresponding to the picture signal duration become uniform (or the same ratio of appearance). Although there are several kinds of states in (B), adjust the value within 2-3 from the initial value. 9. In the same manner as for 8. above, connect oscilloscope to the TP-PB (53 pin of IC 205 - the highest bit) and adjust the value W(E13). 5V (B) Sate of an optimum adjustment Decreae the value 0V 5V (C) W(E11) /W(E13) Too high 0V Fig. 1 Fig. 2 2 No. 51953D GM-P420E CHANGED ITEMS CHANGE OF INPUT SIGNAL GM-P420E/A INPUT SIGNAL 1080/60i 1035/60i GM-P420E/AU 1080/50i Not available NOTE: In accordance with the change this time, the HD SIGNAL MODE in the SET UP MENU will not be displayed. As a result, you can not switch the 1080/60i to the 1035/60i. DIFFERENT ITEM USING PW BOARDS (Page 4) (Although the PWB numbers have been changed, there is no change in other PWBs except for the MAIN PWB) MODEL PWB ASS'Y GM-P420E/A FX-1175A FX-4086A FX-6120A FX-6117A FX-6124A FX-6128A FX-7053A FX-7049A FX-9093A GM-P420E/AU FX-1182A FX-4090A FX-6136A FX-6137A FX-6138A FX-6139A FX-7056A FX-7057A FX-9095A Description Compatible MAIN PWB CONTROL PWB RGB INPUT PWB VIDEO INPUT PWB SP TERMINAL L PWB
File name 51953ien.pdf

GM-P420PCE GM-P421PCE GM-P420E OPERATING INSTRUCTIONS PLASMA DISPLAY MONITOR BEDIENUNGSANLEITUNG : PLASMABILDSCHIRM MANUEL D'INSTRUCTIONS : MONITEUR DE VISUALISATION PLASMA MANUALE D'ISTRUZIONI : MONITOR CON SCHERMO AL PLASMA MANUAL DE INSTRUCCIONES : MONITOR DISPLAY DE PLASMA PLASMA DISPLAY MONITOR GM-P420E GM-P420PCE GM-P420PCE GM-P421PCE GM-P421PCE GM-P420E INSTRUCTIONS MENU INPUT POWER LCT1150-001B Apr. 2002 No. 51953 ESPAÑOL ITALIANO FRANÇAIS DEUTSCH ENGLISH Model GM-P420E GM-P420PCE GM-P421PCE Thank you for purchasing this JVC Monitor. Before using the monitor, read this manual carefully so that you know how to use the Monitor correctly. Refer to this manual whenever questions or problems about operation arise. Be sure to read and observe the safety precautions. Keep this manual where the user can see it easily. * Installation and removal require special expertise. Consult your product dealer for details. ENGLISH 1-2 GM-P420PCE GM-P421PCE GM-P420E Safety Precautions EUROPE EMC STANDARD NOTICE INSTRUCTIONS s GM-P420E/GM-P420PCE Warning: This is a class A product. In a domestic environment this product may cause radio interference in which case the user may be required to take adequate measure. IMPORTANT INFORMATION WARNING: TO REDUCE THE RISK OF FIRE AND ELECTRIC SHOCK, DO NOT EXPOSE THIS PRODUCT TO RAIN OR MOISTURE. This instruction manual refers to the GM-P420E, GM-P420PCE, and GM-P421PCE. The explanations and illustrations used in this instruction manual are of the GM-P420E unless otherwise stated. The differences between each model are as follows: IMPORTANT SAFEGUARDS Electrical energy can perform many useful functions. This unit has been engineered and manufactured to assure your personal safety. But IMPROPER USE CAN RESULT IN POTENTIAL ELECTRICAL SHOCK OR FIRE HAZARD. In order not to defeat the safeguards incorporated into this product, observe the following basic rules for its installation, use and service. Please read these "Important Safeguards" carefully before use. ­ All the safety and operating instructions should be read before the product is operated. ­ The safety and operating instructions should be retained for future reference. ­ All warnings on the product and in the operating instructions should be adhered to. ­ All operating instructions should be followed. ­ Unplug this product from the wall outlet before cleaning. Do not use liquid cleaners or aerosol cleaners. Use a damp cloth for cleaning. ­ Use a vacuum cleaner to get rid of the dust around the intakes (all the openings) on the rear. If a vacuum is not available, use a cloth and wipe it off. Failure to do so will cause internal heat buildup and, therefore, cause damage to the product. ­ Do not use attachments not recommended by the product manufacturer as they may be hazardous. ­ Do not use this product near water. Do not use immediately after moving from a low temperature to high temperature, as this causes condensation, which may result in
File name 51953par.pdf

GM-P420PCE GM-P421PCE GM-P420E PARTS LIST CAUTION ! The parts identified by the " symbol are important for the s afety. Whenever replacing these parts, be s ure to use s pec ified ones to secure the safety . ! The parts not indic ated in this Parts List and those which are filled with lines in the Parts No. c olumns will not be supplied. ! P. W. Board Ass'y will not be supplied, but thos e which are filled with the Parts No. in the Parts No. columns will be s upplied. ABBREVIATIONS OF RESISTORS, CAPACITORS AND TOLERANCES RESISTORS CR FR PR VR HV R MF R MG R MP R OM R CMF R UNF R CH V R CH MG R COMP. R LPTC R Carbon Resistor Fusible Resistor Plate Res istor Variable Res istor High Voltage Resistor Metal Film Resistor Metal Glazed Resistor Metal Plate Resistor Metal Oxide Film Resistor Coating Metal Film Resistor Non-Flammable Resistor Chip Variable Resistor Chip Metal Glazed Resistor Composition Resistor Linear Positive T emperature Coefficient Resistor C CAP. E CAP. M CAP. HV CAP. MF CAP. MM CAP. MP CAP. PP CAP. PS CAP. TF CAP. MPP CAP. TAN. CAP. CH C CAP. BP E CAP. CH AL E CAP. CH AL BP CAP. CH TAN. E CAP. CH AL BP E CAP. CAPACITORS Ceramic Capacitor Electrolytic Capacitor Mylar Capacitor High Voltage Capacitor Metalized Film Capac itor Metalized Mylar Capacitor Metalized Polystyrol Capacitor Polypropylene Capacitor Polystyrol Capacitor Thin F ilm Capacitor Metalized Polypropylene Capacitor Tantalum Capacitor Chip Ceramic Capac itor Bi-Polar Electrolytic Capacitor Chip Aluminum Electrolytic Capacitor Chip Aluminum Bi-Polar Capacitor Chip T antalum Elec trolytic Capacitor Chip T antalum Bi-Polar Electrolytic Capac itor TOLERANCES F ±1% G ±2% J ±5% K ±10% M ±20% N ±30% R +30% -10% H +50% -10% Z +80% -20% P +100% -0% No. 51953 51 GM-P420PCE GM-P421PCE GM-P420E CONTENTS ! USING PW BOARD & REMOTE CONTROL UNIT 53 ! REMOTE CONTROL UNIT PARTS LIST 53 ! EXPLODED VIEW PARTS LIST 54, 56 ! EXPLODED VIEW 54 56 ! PRINTED WIRING BOARD PARTS LIST GM-P420PCE " MAIN PW BOARD ASS'Y 57 " CO NTROL PW BOARD ASS' Y 61 " RG B INPUT PW BOARD ASS'Y 61 " SP TERMINAL L PW BOARD ASS'Y 61 " SP TERMINAL R PW BOARD ASS'Y 61 " LED PW BOARD ASS'Y 62 " TEMP. SENSOR PW BOARD ASS'Y 62 " LINE FILTER & AUDIO PW BOARD ASS'Y 62 GM-P421PCE " MAIN PW BOARD ASS'Y 63 " CO NTROL PW BOARD ASS' Y 67 " RG B INPUT PW BOARD ASS'Y 67 " SP TERMINAL L PW BOARD ASS'Y 67 " SP TERMINAL R PW BOARD ASS'Y 67 " LED PW BOARD ASS'Y 68 " TEMP. SENSOR PW BOARD ASS'Y 68 " LINE FILTER & AUDIO PW BOARD ASS'Y 68 GM-P420E " MAIN PW BOARD ASS'Y 69 " CO NTROL PW BOARD ASS' Y 73 " RG B INPUT PW BOARD ASS'Y 73 " VIDEO INPUT PW BOARD ASS'Y 73 " SP TERMINAL L PW BOARD ASS'Y 74 " SP TERMINAL R PW BOARD ASS'Y 74 " LED PW BOARD ASS'Y 74 " TEMP. SENSOR PW BOARD ASS'Y 74 " LINE FILTER & AUDIO PW BOARD ASS'Y 7
File name 51953sch.pdf

GM-P420PCE GM-P421PCE GM-P420E GM-P420PCE GM-P421PCE GM-P420E CONTENTS SEMICONDUCTOR SHAPES BLOCK DIAGRAM CIRCUIT DIAGRAMS MAIN PWB CIRCUIT DIAGRAM RGB INPUT PWB CIRCUIT DIAGRAM VIDEO INPUT PWB CIRCUIT DIAGRAM (GM-P420E ONLY) TEMP. SENSOR PWB CIRCUIT DIAGRAM LINE FILTER & AUDIO PWB CIRCUIT DIAGRAM CONTROL PWB CIRCUIT DIAGRAM LED PWB CIRCUIT DIAGRAM SP TERMINAL L PWB CIRCUIT DIAGRAM SP TERMINAL R PWB CIRCUIT DIAGRAM 2-2 2-3 GM-P420PCE,GM-P421PCE,GM-P420E STANDARD CIRCUIT DIAGRAM NOTE ON USING CIRCUIT DIAGRAMS 1.SAFETY The components identified by the symbol and shading are critical for safety. For continued safety replace safety critical components only with manufactures recommended parts. Type No indication MM PP MPP MF TF BP TAN (3)Coils No unit : Original setting position when shipped :DC 20k :H :V :Others (5)Voltage values /V 20µS/div 5mS/div Sweeping time is specified Others (4)Test point :Test point (5)Connecting method :Connector :Receptacle (6)Ground symbol :LIVE side ground :ISOLATED(NEUTRAL) side ground :EARTH ground :DIGITAL ground :Wrapping or soldering :Only test point display :[ µ H] :As specified :Ceramic capacitor :Metalized mylar capacitor :Polypropylene capacitor :Metalized polypropylene capacitor :Metalized film capacitor :Thin film capacitor :Bipolar electrolytic capacitor :Tantalum capacitor 2-5 2-17 2-19 2-20 2-21 2-23 2-24 2-23 2-24 2.SPECIFIED VOLTAGE AND WAVEFORM VALUES The voltage and waveform values have been measured under the following conditions. (1)Input signal (2)Setting positions of each knob/button and variable resistor (3)Internal resistance of tester (4)Oscilloscope sweeping time : Colour bar signal PATTERN DIAGRAMS MAIN PWB PATTERN LINE FILTER & AUDIO PWB PATTERN RGB IN PWB PATTERN VIDEO IN PWB PATTERN (GM-P420E ONLY) CONTROL PWB PATTERN LED PWB PATTERN SP TERMINAL L PWB PATTERN SP TERMINAL R PWB PATTERN TEMP. SENSOR PWB PATTERN 2-25 2-29 2-31 2-31 2-33 2-34 2-33 2-33 2-34 :All DC voltage values Since the voltage values of signal circuit vary to some extent according to adjustments, use them as reference values. 3.INDICATION OF PARTS SYMBOL [EXAMPLE] In the PW board :R1209 R209 SEMICONDUCTOR SHAPES TRANSISTOR BOTTOM VIEW FRONT VIEW TOP VIEW CHIP TR C 4.INDICATIONS ON THE CIRCUIT DIAGRAM (1)Resistors Resistance value No unit K M :[ ] :[K ] :[M ] 5.NOTE FOR REPAIRING SERVICE This model's power circuit is partly different in the GND. The difference of the GND is shown by the LIVE : ( ) side GND and the ISOLATED(NEUTRAL) : ( ) side GND.Therefore, care must be taken for the following points. (1)Do not touch the LIVE side GND or the LIVE side GND and the ISOLATED(NEUTRAL) side GND simultaneously. If the above caution is not respected, an electric shock may be caused. Therefore, make sure that the power cord is surely removed from the receptacle when, for example, the chassis is pulled out. (2)Do not short between the LIVE side GND and ISOLATED(NEUTRAL) side GND or never measure with a measuring apparatus



>> Download document << eServiceInfo Context Help
Attention! This manual is multipart. Download all, before decompressing



Was this file useful ? Share Your thoughts with the other users.

User ratings and reviews for this file:

DateUserRatingComment

Average rating for this file: 0.00 ( from 0 votes)


Similar Service Manuals :
JVC AVK14T3 - JVC AVK14T3 - JVC AV-61PRO - JVC AV-20ME - JVC AV-20NN11 - JVC AVK14T3 - JVC AV-61PRO -
 FB -  Links -  Info / Contacts -  Forum -   Last SM download : Philips LC1.15E AA

script execution: 0.13 s