File name STR-DE525,V515.pdfSTR-DE525/V515
SERVICE MANUAL
Ver 1.1 2002. 01
US Model Canadian Model E Model Australian Model PX Model
STR-DE525
Chinese Model
STR-V515
Photo : STR-DE525
Dolby Laboratories Licensing Corporation. "DOLBY" the double-D symbol a "AC-3" and "PRO LOGIC" are trademarks of Dolby Laboratories Licensing Corporation.
SPECIFICATIONS
-- Continued on next page --
FM STEREO/FM-AM RECEIVER
9-922-797-12
2002A1600-1 © 2002.1
Sony Corporation
Home Audio Company Published by Sony Engineering Corporation
--2--
SAFETY CHECK-OUT
After correcting the original service problem, perform the following safety checks before releasing the set to the customer: Check the antenna terminals, metal trim, "metallized" knobs, screws, and all other exposed metal parts for AC leakage. Check leakage as described below.
TABLE OF CONTENTS 1. 2. 3.
3-1. 3-2. 3-3. 3-4. 3-5. 3-6. 3-7. 3-8. 3-9. 3-10. 3-11. 3-12. 3-13. 3-14.
GENERAL ······································································ 4 TEST MODE ···························································· 6 DIAGRAMS
Circuit Boards Location ····················································· 7 Block Diagram -- Main Section -- ··································· 9 Block Diagram -- Power Section -- ······························· 11 Printed Wiring Board -- AMP Section -- ······················· 13 Schematic Diagram -- AMP Section -- ·························· 15 Printed Wiring Board -- Video Section -- ······················ 17 Schematic Diagram -- Video Section -- ························· 19 Printed Wiring Board -- Input Section -- ······················· 21 Schematic Diagram -- Input Section -- ·························· 23 Printed Wiring Board -- Display Section -- ··················· 25 Schematic Diagram -- Display Section -- ······················ 27 Printed Wiring Board -- Power Section -- ····················· 29 Schematic Diagram -- Power Section -- ························ 31 IC Block Diagrams ··························································· 35
LEAKAGE
The AC leakage from any exposed metal part to earth ground and from all exposed metal parts to any exposed metal part having a return to chassis, must not exceed 0.5 mA (500 microampers). Leakage current can be measured by any one of three methods. 1. A commercial leakage tester, such as the Simpson 229 or RCA WT-540A. Follow the manufacturers' instructions to use these instruments. A battery-operated AC milliammeter. The Data Precision 245 digital multimeter is suitable for this job. Measuring the voltage drop across a resistor by means of a VOM or battery-operated AC voltmeter. The "limit" indication is 0.75 V, so analog meters must have an accurate low-voltage scale. The Simpson 250 and Sanwa SH-63Trd are examples of a passive VOM that is suitable. Nearly all battery operated digital multimeters that have a 2V AC range are suitable. (See Fig. A)
2.
3.
4.
EXPLODED VIEWS
4-1. Front Panel Section ······································· |