File name BBK 965S service manual.pdfSERVICE MANUAL
bbk965S
VOL1 VOL2
CONTENTS
1. SAFETY PRECAUTIONS 1
2. PREVENTION OF ELECTRO STATIC DISCHARGE(ESD)TO ELECTROSTATICALLY
SENSITIVE(ES)DEVICES 1
3. CONTROL BUTTON LOCATIONS AND EXPLANATIONS 2
4. PREVERTION OF STATIC ELECTRICITY DISCHARGE 3
5. ASSEMBLING AND DISASSEMBLING THE MECHANISM UNIT 4
5.1 OPTICAL PICKUP UNIT EXPLOSED VIEW AND PART LIST 4
5.2 BRACKET EXPLOSED VIEW AND PART LIST 6
5.3 MISCELLANEOUS 7
6. ELECTRICAL CONFIRMATION 8
6.1 VIDEO OUTPUT (LUMINANCE SIGNAL) CONFIRMATION 8
6.2 VIDEO OUTPUT(CHROMINANCE SIGNAL) CONFIRMATION 9
7. MPEG BOARD CHECK WAVEFORM 10
8. AM29LV160D 11
8.1 HY57V641620HG 16
8.2 MT1389 19
9. SCHEMATIC & PCB WIRING DIAGRAM 22
10. SPARE PARTS LIST 34
1. SAFETY PREAUTIONS
1.1 GENERAL GUIDELINES
1. When servicing, observe the original lead dress. if a short circuit is found, replace all parts which have
been overheated or damaged by the short circuit.
2. After servicing, see to it that all the protective devices such as insulation barrier, insulation papers
shields are properly installed.
3. After servicing, make the following leakage current checks to prevent the customer from being exposed
to shock hazards.
2.PREVENTION OF ELECTRO STATIC DISCHARGE(ESD)TO
ELECTROSTATICALLY SENSITIVE(ES)DEVICES
Some semiconductor(solid state)devices can be damaged easily by static electricity. Such components
commonly are called Electrostatically Sensitive(ES)Devices. Examples of typical ES devices are integrated
circuits and some field-effect transistors and semiconductor chip components. The following techniques
should be used to help reduce the incidence of component damage caused by electro static discharge(ESD).
1. Immediately before handling any semiconductor component or semiconductor-equipped assembly, drain
off any ESD on your body by touching a known earth ground. Alternatively, obtain and wear a commercially
availabel discharging ESD wrist strap, which should be removed for potential shock reasons prior to
applying power to the unit under test.
2. After removing an electrical assembly equipped with ES devices,place the assembly on a conductive
surface such as alminum foil, to prevent electrostatic charge buildup or exposure of the assembly.
3. Use only a ground |