File name RZ-14LA60 Ch.ML-024H.pdfwebsite:http://biz.LGservice.com e-mail:http://www.LGEservice.com/techsup.html
LCD TV SERVICE MANUAL
CHASSIS : ML-024H
MODEL : RZ-14LA60
CAUTION
BEFORE SERVICING THE CHASSIS, READ THE SAFETY PRECAUTIONS IN THIS MANUAL.
CONTENTS
CONTENTS ... 2 PRODUCT SAFETY ...3 DESCRIPTION OF CONTROLS ... 4 SPECIFICATION ...7 ADJUSTMENT INSTRUCTION ...9 TROUBLE SHOOTING ...14 BLOCK DIAGRAM...15 EXPLODED VIEW ... 16 EXPLODED VIEW PARTS LIST ...17 REPLACEMENT PARTS LIST ... 18 SVC. SHEET ...
SAFETY PRECAUTIONS
IMPORTANT SAFETY NOTICE
Many electrical and mechanical parts in this chassis have special safety-related characteristics. These parts are identified by in the Schematic Diagram and Replacement Parts List. It is essential that these special safety parts should be replaced with the same components as recommended in this manual to prevent X-RADIATION, Shock, Fire, or other Hazards. Do not modify the original design without permission of manufacturer.
General Guidance
An isolation Transformer should always be used during the servicing of a receiver whose chassis is not isolated from the AC power line. Use a transformer of adequate power rating as this protects the technician from accidents resulting in personal injury from electrical shocks. It will also protect the receiver and it's components from being damaged by accidental shorts of the circuitry that may be inadvertently introduced during the service operation. If any fuse (or Fusible Resistor) in this TV receiver is blown, replace it with the specified. When replacing a high wattage resistor (Oxide Metal Film Resistor, over 1W), keep the resistor 10mm away from PCB. Keep wires away from high voltage or high temperature parts.
Before returning the receiver to the customer,
always perform an AC leakage current check on the exposed metallic parts of the cabinet, such as antennas, terminals, etc., to be sure the set is safe to operate without damage of electrical shock.
Leakage Current Cold Check(Antenna Cold Check)
With the instrument AC plug removed from AC source, connect an electrical jumper across the two AC plug prongs. Place the AC switch in the on position, connect one lead of ohm-meter to t |