File name LTN1765.pdfTFT-LCD MONITOR
Chassis AS15U* AS17U* Model LTN1565 LTN1765
SERVICE
TFT-LCD MONITOR
Manual
CONTENTS
1. Precautions 2. Product Specifications 3. Disassembly & Reassembly 4. Alignment & Adjustments 5. Troubleshooting 6. Exploded View & Parts List 7. Electrical Parts List 8. Block Diagram 9. Wiring Diagram 10. PCB Layout 11. Schematic Diagrams 12. Panel Description
Samsung Electronics Co.,Ltd. 416, Maetan-3Dong, Paldal-Gu, Suwon City, Kyungki-Do, Korea, 442-742 Printed in Korea P/N : BN82-00098A-00 http : //www.samsungmonitor.com (SyncMaster Worldwide) http : //www.samsung-monitor.com (SyncMaster USA) URL : http://ecms. samsungelectronics. com/
1 Precautions
Follow these safety, servicing and ESD precautions to prevent damage and to protect against potential hazards such as electrical shock.
1-1 Safety Precautions
1-1-1 Warnings
1. 2. For continued safety, do not attempt to modify the circuit board. Disconnect the AC power and DC Power Jack before servicing.
DEVICE UNDER TEST TEST ALL EXPOSED METAL SURFACES (READING SHOULD NOT BE ABOVE 0.5mA)
1-1-2 Servicing the LCD Monitor
1. 2. When servicing the LCD Monitor disconnect the AC line cord from the AC outlet. It is essential that service technicians have an accurate voltage meter available at all times. Check the calibration of this meter periodically.
LEAKAGE CURRENT TESTER
2-WIRE CORD
1-1-3 Fire and Shock Hazard
Before returning the monitor to the user, perform the following safety checks: 1. Inspect each lead dress to make certain that the leads are not pinched or that hardware is not lodged between the chassis and other metal parts in the monitor. Inspect all protective devices such as nonmetallic control knobs, insulating materials, cabinet backs, adjustment and compartment covers or shields, isolation resistor-capacitor networks, mechanical insulators, etc. Leakage Current Hot Check (Figure 1-1): WARNING: Do not use an isolation transformer during this test. Use a leakage current tester or a metering system that complies with American National Standards Institute (ANSI C101.1, Leakage Current for Appliances), and Underwriters Laboratories (UL Publication UL1410, 59.7). 4.
ALSO TEST WITH PLUG REVERSED (USING AC ADAPTER PLUG AS REQUIRED)
EARTH GROUND
Figure 1-1. Leakage Current Test Circuit
With the unit completely reassembled, plug the AC line cord directly into a 120V AC outlet. With the unit's AC switch first in the ON position and then OFF, measure the current between a known earth ground (metal water pipe, conduit, etc.) and all exposed metal parts, including: metal cabinets, screwheads and control shafts. The current measured should not exceed 0.5 milliamp. Reverse the power-plug prongs in the AC outlet and repeat the test.
2.
3.
1-1-4 Product Safety Notices
Some electrical and mechanical parts have special safety-related characteristics which are often not evident from visual inspection. The protection they give may not be obtained by replacing them with components rated for |