File information: | |
File name: | sony dsr-pd150.part06.rar |
Size: | 2832 kB |
Extension: | rar |
Mfg: | Sony |
Model: | DSR PD-150 🔎 |
Original: | |
Descr: | service manual |
Group: | Electronics > Consumer electronics > Video cameras |
Uploaded: | 27-06-2008 |
User: | atlaspak |
Multipart: | 0 1 2 3 4 5 6 7 8 9 10 11 |
Information about the files in archive: | ||
Decompress result: | OK | |
Extracted files: | 2 | |
File name 992982411.pdf DSR-PD150/PD150P RMT-811 SERVICE MANUAL Ver 1.1 2000. 11 With SUPPLEMENT-1 (9-929-824-81) US Model Canadian Model DSR-PD150 AEP Model DSR-PD150P Photo : DSR-PD150 C MECHANISM NTSC model : DSR-PD150 PAL model : DSR-PD150P SPECIFICATIONS -- Continued on next page -- DIGITAL CAMCORDER · SUPPLIED ACCESSORIES Check that the following accessories are supplied with your camcorder. SAFETY-RELATED COMPONENT WARNING!! COMPONENTS IDENTIFIED BY MARK 0 OR DOTTED LINE WITH MARK 0 ON THE SCHEMATIC DIAGRAMS AND IN THE PARTS LIST ARE CRITICAL TO SAFE OPERATION. REPLACE THESE COMPONENTS WITH SONY PARTS WHOSE PART NUMBERS APPEAR AS SHOWN IN THIS MANUAL OR IN SUPPLEMENTS PUBLISHED BY SONY. ATTENTION AU COMPOSANT AYANT RAPPORT À LA SÉCURITÉ! LES COMPOSANTS IDENTIFÉS PAR UNE MARQUE 0 SUR LES DIAGRAMMES SCHÉMATIQUES ET LA LISTE DES PIÈCES SONT CRITIQUES POUR LA SÉCURITÉ DE FONCTIONNEMENT. NE REMPLACER CES COMPOSANTS QUE PAR DES PIÈSES SONY DONT LES NUMÉROS SONT DONNÉS DANS CE MANUEL OU DANS LES SUPPÉMENTS PUBLIÉS PAR SONY. SAFETY CHECK-OUT After correcting the original service problem, perform the following safety checks before releasing the set to the customer. 1. Check the area of your repair for unsoldered or poorly-soldered connections. Check the entire board surface for solder splashes and bridges. Check the interboard wiring to ensure that no wires are "pinched" or contact high-wattage resistors. Look for unauthorized replacement parts, particularly transistors, that were installed during a previous repair. Point them out to the customer and recommend their replacement. Look for parts which, through functioning, show obvious signs of deterioration. Point them out to the customer and recommend their replacement. 5. Check the B+ voltage to see it is at the values specified. 6. Flexible Circuit Board Repairing · Keep the temperature of the soldering iron around 270°C during repairing. · Do not touch the soldering iron on the same conductor of the circuit board (within 3 times). · Be careful not to apply force on the conductor when soldering or unsoldering. 4. 2. 3. --2-- TABLE OF CONTENTS SERVICE NOTE 1. 2. POWER SUPPLY DURING REPAIRS ····························· 7 TO TAKE OUT A CASSETTE WHEN NOT EJECT (FORCE EJECT) ································································ 7 Customizing Your Camcorder ················································· 1-26 Changing the menu settings ················································· 1-26 Resetting the date and time ·················································· 1-28 "Memory Stick" Operations ···················································· 1-28 Using a "Memory Stick" introduction ······························· 1-28 Recording still images on a "Memory Stick" Memory Photo recording ··················································· 1-29 Superimposing a still picture in a "Memory Stick" on a moving picture MEMORY MIX ································ 1-30 Recording an image from a tap | ||
File name 992982481.pdf DSR-PD150/PD150P RMT-811 DSR-PD150 US Model Canadian Model SERVICE MANUAL 2000. 11 AEP Model DSR-PD150P SUPPLEMENT-1 File this supplement-1 with the Service Manual. (PV00-019) Subject: · Change of Self-Diagnosis code table · Change of Adjusting item · Change of Adjustments · Added of Supplied parts SELF-DIAGNOSIS FUNCTION 4. Repaired by: SELF-DIAGNOSIS CODE TABLE (Refer to page 9) : Added portion. : Changed portion. Self-diagnosis Code Block Detailed Function Code Symptom/State Correction C C C C C C C C C C C C C C C C C C C 3 3 3 3 3 3 3 3 3 3 3 3 3 3 3 3 3 3 3 1 1 1 1 1 1 2 2 2 2 2 2 2 2 2 2 2 2 2 3 4 4 9 9 9 1 1 2 2 2 2 2 3 4 4 9 9 9 0 0 2 7 8 9 0 1 0 1 2 3 4 0 0 2 7 8 9 FG fault when starting capstan. FG fault when starting drum. FG fault during normal drum operations. Mechanical position fault. Mechanical position fault. Mechanical position fault. LOAD direction loading motor timeout. UNLOAD direction loading motor time-out. T reel side tape slacking when unloading. Winding S reel fault when counting the rest of tape. T reel fault. S reel fault. T reel fault. FG fault when starting capstan. FG fault when starting drum FG fault during normal drum operations Mechanical position fault. Mechanical position fault. Mechanical position fault. Difficult to adjust focus (Cannot initialize focus.) E 6 1 0 0 Load the tape again, and perform operations from the beginning. Load the tape again, and perform operations from the beginning. Load the tape again, and perform operations from the beginning. Load the tape again, and perform operations from the beginning. Load the tape again, and perform operations from the beginning. Load the tape again, and perform operations from the beginning. Remove the battery or power cable, connect, and perform operations from the beginning. Remove the battery or power cable, connect, and perform operations from the beginning. Remove the battery or power cable, connect, and perform operations from the beginning. Remove the battery or power cable, connect, and perform operations from the beginning. Remove the battery or power cable, connect, and perform operations from the beginning. Remove the battery or power cable, connect, and perform operations from the beginning. Remove the battery or power cable, connect, and perform operations from the beginning. Remove the battery or power cable, connect, and perform operations from the beginning. Remove the battery or power cable, connect, and perform operations from the beginning. Remove the battery or power cable, connect, and perform operations from the beginning. Remove the battery or power cable, connect, and perform operations from the beginning. Remove the battery or power cable, connect, and perform operations from the beginning. Remove the battery or power cable, connect, and perform operations from the beginning. Inspect the lens block focus reset sensor (Pin wg of LA-026 board) when focusing is performed when the control dial is rotated in the focus |
Date | User | Rating | Comment |