File name EL Series Service Manual (including EL302Tv).pdfEL Series
(including EL302Tv)
Power Supplies
Service Manual
Manual Part Number 48511-0380 Issue 2
Applicability
This Service Manual covers models EL301, EL302, EL183, EL561, EL302D, EL302T and EL302Tv from
their introduction to the present.
Models EL303 and EL155 are covered by a separate manual 48511-0920.
Table of Contents
Specification 2
Safety 4
EMC 5
Installation 6
General 7
Circuit Descriptions 9
Calibration 11
Parts List 13
Component Layouts & Circuit Diagrams 35
1
Specification
MAIN OUTPUTS
Voltage Range: 0V to 18V minimum (EL183)
0V to 30V minimum (EL301, EL302, EL302D, EL302T, EL302Tv)
0 to 56V minimum (EL561)
Current Range: 0A to 1A minimum (EL301)
0A to 1.1A minimum (EL561)
0A to 2A minimum (EL302, EL302D, EL302T, EL302Tv)
0A to 3.3A minimum (EL183)
Voltage Setting: By coarse and fine controls.
Current Setting: By single logarithmic control.
Operating Mode: Constant voltage or constant current with automatic cross-over.
Output Switch: Electronic. Preset voltage and current displayed when off.
Output Terminals: Universal 4mm safety binding posts on 19mm (0.75") pitch.
Output Impedance: Typically <5m in constant voltage mode.
Typically >50k in constant current mode.
Output Protection: Outputs will withstand forward voltages of up to 20V above the rated
output voltage. Reverse protection by diode clamp for currents up to 3A.
Load Regulation: <0.01% of maximum output for 90% load change.
Line Regulation: <0.01% of maximum output for 10% line change.
Ripple & Noise: Typically <1mVrms (CV mode).
(20MHz bandwidth)
Transient Load Response: <20 |