File name 42PX4RV (MF-056A).pdfwebsite:http://biz.LGservice.com
e-mail:http://www.LGEservice.com/techsup.html
PLASMA TV
SERVICE MANUAL
CHASSIS : MF-056A
MODEL : 42PX4RV/RVA
42PX4RV/RVA-ZA
CAUTION
BEFORE SERVICING THE CHASSIS,
READ THE SAFETY PRECAUTIONS IN THIS MANUAL.
TV/AV MENU OK VOL PR
CONTENTS
SAFETY PRECAUTIONS ...3
DESCRIPTION OF CONTROLS ...4
SPECIFICATIONS ...9
ADJUSTMENT INSTRUCTIONS ...11
TROUBLE SHOOTING GUIDE ...15
BLOCK DIAGRAM ...24
EXPLODED VIEW ...26
EXPLODED VIEW PARTS LIST ...27
REPLACEMENT PARTS LIST...28
SCHEMATIC DIAGRAM...
PRINTED CIRCUIT BOARD ...
- 2 -
SAFETY PRECAUTIONS
IMPORTANT SAFETY NOTICE
Many electrical and mechanical parts in this chassis have special safety-related characteristics. These parts are identified by in
the Schematic Diagram and Replacement Parts List.
It is essential that these special safety parts should be replaced with the same components as recommended in this manual to
prevent X-RADIATION, Shock, Fire, or other Hazards.
Do not modify the original design without permission of manufacturer.
General Guidance Leakage Current Hot Check (See below Figure)
Plug the AC cord directly into the AC outlet.
An isolation Transformer should always be used during Do not use a line Isolation Transformer during this check.
the servicing of a receiver whose chassis is not isolated from Connect 1.5K/10watt resistor in parallel with a 0.15uF capacitor
the AC power line. Use a transformer of adequate power rating between a known good earth ground (Water Pipe, Conduit, etc.)
as this protects the technician from accidents resulting in and the exposed metallic parts.
personal injury from electrical shocks. |