File name HarmanKardon-AVR500 rec.pdfharman/kardon
AVR500
A/V DOLBY DIGITAL RECEIVER
SERVICE MANUAL
CONTENTS
SPECIFICATIONS ...2 ESD WARNINGS... 4 LEAKAGE TEST... 5 CONTROLS AND FUNCTIONS...6 SERVICE PROCEDURE... .9 TEST EQUIPMENT REQUIRED... ...9 ALIGNMENT PROCEDURES...9 ALIGNMENT AND TEST POINTS... 11 CIRCUIT DESCRIPTION...13 BLOCK DIAGRAM ...16 BULLETIN HK2000-02...17 BULLETIN HK2000-04...19 BULLETIN HK2000-05...21 DISASSEMBLY PROCEDURES ... ...23 GENERAL UNIT PARTS LIST ...24 GENERAL UNIT EXPLODED VIEW... 26 PC . BOARDS ...27 ELECTRICAL PARTS LIST ...32 IC BLOCK DIAGRAMS ...55 CPU PIN CONFIGURATION...75 FLT PIN CONFIGURATION... 76 SCHEMATIC DIAGRAMS ...83 PIN CONNECTION DIAGRAM ...92 WIRING DIAGRAM ...93 PACKING MATERIAL AND PARTS LIST...94
harman/kardon, Inc. 250 Crossways Park Dr. Woodbury, New York 11797 Rev1 11/2003
500
RMS Output Power
All Channel Driven
65W
65W
Input Shorted, IHF-A WTD
65dB
60dB
8 ohms, Dolby Pro Logic
100Hz-20kHz 150Hz-20kHz
500
500
Some semiconductor (solid state) devices can be damaged easily by static electricity. Such components commonly are called Electrostatically Sensitive (ES) Devices. Examples of typical ES devices are integrated circuits and some field effect transistors and semiconductor "chip" components. The following techniques should be used to help reduce the incidence of component damage caused by static electricity. 1. Immediately before handling any semiconductor component or semiconductor-equipped assembly, drain off any electrostatic charge on your body by touching a known earth ground. Alternatively, obtain and wear a commercially available discharging wrist strap device, which should be removed for potential shock reasons prior to applying power to the unit under test. 2. After removing an electrical assembly equipped with ES devices, place the assembly on a conductive surface such as aluminum foil, to prevent electrostatic charge build-up or exposure of the assembly. 3. Use only a grounded-tip soldering iron to solder or unsolder ES devices. 4. Use only an anti-static solder removal device. Some solder removal devices not classified as "anti-static" can generate electrical charges sufficient to damage ES devices. 5. Do not use freon-propelled chemicals. These can generate electrical change sufficient to damage ES devices. 6. Do not remove a replacement ES device fro |